Scipion-ED: a graphical user interface for batch processing and analysis of 3D ED/MicroED data
aDepartment of Materials and Environmental Chemistry, Stockholm University, Stockholm, SE-106 91, Sweden, and bDepartment of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Stockholm, SE-106 91, Sweden
*Correspondence e-mail: delarosatrevin@scilifelab.se, xzou@mmk.su.se, hongyi.xu@mmk.su.se
Three-dimensional electron diffraction (3D ED)/microcrystal electron diffraction (MicroED) techniques are gaining in popularity. However, the data processing often does not fit existing graphical user interface software, instead requiring the use of the terminal or scripting. Scipion-ED, described in this article, provides a graphical user interface and extendable framework for processing of 3D ED/MicroED data. An illustrative project is described, in which multiple 3D ED/MicroED data sets collected on tetragonal lysozyme were processed with DIALS through the Scipion-ED interface. The ability to resolve unmodelled features in the electrostatic potential map was compared between three strategies for merging data sets.
Keywords: electron diffraction; 3D ED; MicroED; data processing; computer programs.
1. Introduction
Over the past few years, three-dimensional electron diffraction (3D ED)/microcrystal electron diffraction (MicroED) techniques for et al., 2019). Structures determined using these techniques include small organic molecules, inorganic materials and proteins (Kolb et al., 2010; Jiang et al., 2011; Gorelik et al., 2012; Martínez-Franco et al., 2013; Smeets et al., 2013, 2014; Zhang et al., 2013; Shi et al., 2013; Su et al., 2014; Yonekura et al., 2015; Clabbers et al., 2017, 2021; Gruene et al., 2018; Jones et al., 2018; Lanza et al., 2019; Xu et al., 2019). Among the more recent improvements in 3D ED/MicroED are the use of continuous rotation of the crystal during data collection, commonly referred to as MicroED (Nannenga & Gonen, 2016) or continuous rotation electron diffraction (cRED) (Wang et al., 2018), and the use of fast and sensitive hybrid pixel detectors (van Genderen et al., 2016; Llopart et al., 2007). These improvements have enabled rapid acquisition of 3D ED/MicroED data and the possibility of processing those data using software developed for X-ray crystallography, such as XDS (Kabsch, 2010) and DIALS (Winter et al., 2018).
determination have gained traction as complementary to X-ray crystallography and cryo-electron microscopy (cryo-EM) (GemmiThe increasing acquisition speed and the increasing adoption of 3D ED/MicroED naturally lead to larger quantities of data that need to be processed and analysed as well as an increasing number of scientists at the novice level for the specific data processing methods. An increased quantity of data is also the result of data collection automation (Wang et al., 2019). Consequently, tools are needed to process the data more easily and more quickly in a straightforward way. An initial solution has been suggested through the program edtools, which adds a layer for running XDS on multiple data sets at once and then merging those with sufficient similarity (Wang et al., 2019).
The challenge of large quantities of data has been handled in X-ray crystallography through integrated pipelines with graphical user interfaces (GUIs). Examples include CCP4i2 (Potterton et al., 2018), XDSGUI (Kabsch, 2016) and KAMO (Yamashita et al., 2018). However, these interfaces are typically designed for synchrotron beamlines where the experimental geometry is well defined, image formats are standardized and the recorded diffraction patterns are from a highly curved These criteria are often not met in the case of electron diffraction. Data processing parameters need to be tailored for different microscope and detector setups. In addition, the collection of 3D ED/MicroED data using cRED sometimes involves defocusing the beam to create an image instead of the diffraction pattern, which requires their exclusion during processing (Smeets et al., 2017; Cichocka et al., 2018; Wang et al., 2019). Existing GUIs such as those listed do not provide access to all the necessary parameters from electron diffraction data.
Large quantities of data and a need for integrated workflows are also found in cryo-EM. One solution designed for those needs is Scipion (de la Rosa-Trevín et al., 2016). It provides a workflow-focused GUI where each step is represented by a protocol. The protocols offer a unified interface for different programs used for processing cryo-EM micrographs. Scipion also stores metadata such as the location of raw images and the input parameters needed for repeating a certain protocol or a workflow consisting of multiple linked protocols. It is thus possible to reuse the same parameters for a different project and to deposit the processing parameters along with the raw data in online databases. It is also possible to add new protocols when additional programs become available, using the same interface and storage formats for input parameters and output. Furthermore, the framework is suitable for developing additional interfaces on top of the underlying infrastructure. For example, some cryo-EM processing workflows were exposed as web tools (Mingo et al., 2018) for easy access and learning. A lot of effort has also been dedicated to on-the-fly data processing (Gómez-Blanco et al., 2018), allowing overlapping data collection with data pre-processing and quick quality assessment.
This article describes Scipion-ED, which extends the Scipion framework to include 3D ED/MicroED processing. This GUI will be useful for existing and new 3D ED/MicroED users, especially the facilities and users that employ both 3D ED/MicroED and cryo-EM on the same equipment, since requirements for training and software maintenance are reduced. There are a number of advantages for using Scipion-ED to process 3D ED/MicroED data. Firstly, graphical user interfaces are often preferable to the command line when first using a program, making it more user friendly for beginners. Secondly, copying and pasting a workflow is more straightforward than writing a script when reusing processing parameters for a new data set. It allows large quantities of data to be processed rapidly. Furthermore, Scipion-ED offers convenience in data analysis and developing data merging strategies. Finally, it is designed in a way that prevents accidental overwriting of the output from one run by the next. Such accidents are most likely when performing initial exploratory analysis or when reprocessing an old data set.
In this paper, we describe the implementation of Scipion-ED and demonstrate how it can be used for batch data processing, data analyses, improving data processing and finding merging strategies.
2. Scipion-ED
Scipion is a framework built from multiple Python modules that define the basic workflow engine and provide the protocols that can be executed. The common components for defining the GUI, keeping track of metadata in a database and handling of job execution are implemented in the scipion-pyworkflow module [Fig. 1(a)]. Specific protocols and input/output data entities for a given scientific domain are defined on top of the core module. Currently, the most developed domain is cryo-EM for which scipion-em serves as the base plugin [Fig. 1(b)]. Several plugins have been implemented for integrating cryo-EM software packages into Scipion, such as relion (Sharov et al., 2021), localrec (Abrishami et al., 2021) and xmipp (Sorzano et al., 2004) [see Fig. 1(c)]. The base plugin of Scipion-ED thus provides the interface between diffraction-oriented protocols and scipion-pyworkflow as well as basic protocols for processing workflows, such as importing diffraction patterns. Specific protocols for interfacing with the actual data processing software are built on top of the base plugin.
3. Graphical user interface and scipion-ed-dials
Each protocol in scipion-ed-dials represents a processing step in DIALS. The choice of DIALS was made because both Scipion and DIALS are Python based and open source. This offers future potential of calling internal DIALS functions directly from scipion-ed-dials, rather than through a shell.
The full data processing, from importing of diffraction patterns to exporting of a scaled reflection file, is illustrated in Fig. 2. Each step of the process is described below, with a general description and specific examples of the processing of data sets collected on tetragonal lysozyme crystals. The supplementary information contains details of the data collection.
Information moves between protocols as shown by the lines connecting the green boxes, using a database and Python objects named Sets. The Sets are Python classes defined in the base plugin of Scipion-ED and contain metadata about multiple items of the same type. As an illustration, the import protocol generates a DiffractionImage object for each imported diffraction pattern, containing information about file location and information extracted from the file header. SetOfDiffractionImages represents all the DiffractionImages related to a run of the import protocol and also includes information on which images to skip (if any; see Importing data below).
Additional protocols can be added to the process from the menu on the left side of the interface or by copying the selected protocol. The bottom of the screen shows a summary of the input given to and actions performed by the protocol. The red button labelled `Analyze Results' gives access to additional information and analysis tools implemented in DIALS.
4. Importing data
Specifying the location of the diffraction images is a necessary step common to all data reduction programs. The input interface shown in Fig. 3 is therefore designed in the base Scipion-ED plugin. Locating the diffraction images is split into the `Files directory' input, where a browser GUI can be used to identify the unique part of a directory path, and the `Pattern' box, where the general structure of subdirectories and filename can be specified.
The `{TI}' placeholder replaces digits in the filenames that uniquely identify a specific diffraction pattern within the folder. The `Skip images' option can then be used to mark every nth frame (with n used as input) as inappropriate for use, such as when using defocused images in Instamatic (Cichocka et al., 2018; Smeets et al., 2021). The empty boxes in Fig. 3, as well as in other protocols, indicate that by default no value is used. Other boxes have pre-filled values. Some of these are based on DIALS defaults, such as the number of processes to use (see Fig. 6 in Section 6). Others, such as the insertion string for import templates (Fig. 3), are based on our experience. These defaults are intended as a starting point, and fine-tuning for a particular experiment might be required.
The plugins define how the input is used. For scipion-ed-dials, the plugin creates a text string with the full command line call to run dials.import, the corresponding step in DIALS. The typical behaviour in Scipion-ED is that each diffraction pattern is added to the call, but it is also possible to use a template function instead. The metadata contained in the first image of the series will then be extrapolated to the entire series. A use case for the template is where the goniometer rotation (PHI in Fig. S1) is set to the same value for all diffraction images instead of the true angle.
The lysozyme data set (Xu & Bengtsson, 2022) used in this work as an example was imported as SMV files (described in the supplementary information), but other formats can also be used in DIALS [as described by Parkhurst et al. (2014)]. However, the converted patterns are rotated relative to the detector format expected in DIALS. The goniometer rotation axis therefore had to be corrected using the dedicated boxes. Initial access to the rotation axis box requires the `Expert Level' to be set as `Advanced'. Details on how to identify the correct rotation axis can be found in the DIALS tutorial MyD88TIR small wedges (Waterman, 2021). It is also possible to use the program dials.find_rotation_axis, added to DIALS in version 3.7.0. The rotation axis should be constant for each experimental setup.
5. Spot finding
Spot finding is the step in DIALS where groups of pixels that have detected a signal are identified and assigned as a spot that can be indexed in later steps. The resolution range 2.0–30.0 Å was used in the processing of the lysozyme data sets to avoid noise close to the direct beam and at higher resolutions. It is also possible to select a range of images to include for processing. The most common reason to do this is to remove frames where the crystal is known to be outside the beam. There are also options available for adjusting the settings of the spot-finding algorithm. These include a choice of which specific algorithm to use and how much a strong spot should deviate from the background. The effects of changing a parameter can be tested through the DIALS image viewer, as illustrated in Fig. 4. The figure contains both the spot-finding results viewer, with buttons for opening additional viewers, and the image viewer.
Out of 47 lysozyme data sets, 33 could be fully processed with no changes to the default parameters beyond the resolution ranges. Two additional data sets could be used after further optimization of the spot-finding settings.
The results of multiple different combinations of input parameter values had to be compared for the data sets that could not be processed using default ED settings for all protocols. Scipion-ED greatly simplified this process by allowing simple copying of workflows, making it easy to change parameter values and ensuring that the original processing flow is kept for comparison. Identifying where changes were introduced and which step fails is also easy, as exemplified by the split tree and failed protocols in Fig. 5. Using scripts or pure command line input to accomplish the same comparison would require more steps and risk overwriting the original processing, and it would be less obvious as to where changes were introduced.
6. Indexing and refinement
The indexing protocol incorporates three functions: indexing, refining the Bravais settings and reindexing based on the refined settings. The first two of these also include some degree of dials.refine through the protocol. The input interfaces for both the indexing protocol (Fig. 6) and the protocol (Fig. 7) contain options to fix parameters of the diffraction geometry and the crystal models as part of the It is important to fix either the detector distance or the unit-cell dimensions in electron diffraction, since these will influence each other owing to the flatness of the The default option in scipion-ed-dials is to keep the detector distance fixed.
of the experiment model, although is primarily performed byThe current implementation of scipion-ed-dials always returns the highest symmetry suggested from refining the Bravais setting, since this is often a reasonable assumption. Trying other symmetries can be done by rerunning the indexing step with a given as shown in Fig. 6. The corresponding model file will be automatically used for output from the protocol, but reindexing the reflection file requires additional confirmation through checkboxes.
One of the primary considerations during cell et al., 2018). For the lysozyme data set, static was performed first with the unit-cell parameters restrained to values found in the literature [comparable to the process used by Waterman (2021)] to provide a good starting point, followed by scan-varying to improve the model. One round of static followed by scan-varying has become standard in dials.refine after the design of the protocol used during processing. The corresponding changes have been added to version 3!1.0.1 of scipion-ed-dials.
is whether to use static or scan-varying The difference is that scan-varying allows some parameters to vary throughout the data set, such as orientation and (WinterThe restraints given during the static supplementary information) in the project directory and given as direct command line input. A field for such input is provided in each protocol by selecting the advanced expert level. Anything written there, such as additional flags, will be added to the end of the command line call to DIALS. Therefore, parameters that have not been added to the scipion-ed-dials interface can still be used in the DIALS processing.
were provided through a phil-format file (included in theAvoiding rarely used parameters cluttering the interface is the primary reason for parameter exclusion. Moreover, recently added parameters in DIALS may not yet be included in scipion-ed-dials. Thus, the requirement to write a phil file with the restraints has been removed in version 3!1.0.1 of scipion-ed-dials. The values can now instead be added directly in dedicated boxes, as seen in Fig. 7.
7. Integration, scaling and export
Integration of all intensity belonging to the same indexed spot from multiple diffraction images in the refined data sets is typically straightforward, with or without trimming the resolution range being the main question. Trimming the resolution reduces computational time, but excessive trimming removes useful information. Trimming is also possible during scaling (or earlier during spot finding), but the default is to keep everything. A resolution range of 2.0–30.0 Å was kept for all protocols during the processing of the lysozyme data sets.
Scaling offers more options, as seen in Fig. 8. The most obvious difference compared with other protocols is that scaling accepts the output from multiple data sets as input. They can be selected from a list in the GUI, while the equivalent operation using the command line would require the entering of each file path individually or through regular expressions. That is one reason for why Scipion-ED is well suited to the comparison of strategies for merging data sets – the same scaling protocol could be copied multiple times and different selections of data sets could be compared.
Another significant difference between scaling and other protocols is that scaling creates an HTML summary automatically, rather than requiring dials.report to run. In protocols other than scaling, there is therefore a tab marked `HTML report', and all interfaces allow the option to open the file as soon as the protocol has finished. It is also always possible to open the report through the results viewer (red button in Fig. 4), and the report will be opened in a web browser or other default program for opening HTML files. In particular, the scaling report provides a useful visual presentation of the results, such as which frames contribute to poor signal-to-noise ratios or which resolution is appropriate. Such frames can then be excluded by giving their indices in the interface.
Excluding images, as enabled by the `Selections' section at the bottom of Fig. 8, is also very useful for removing frames that are known to contain unreliable intensities. Typical examples are frames collected along major zone axes of the crystal, causing strong dynamical effects, and frames collected when the crystal moved out of the electron beam.
There are useful ways of removing poor diffraction patterns, groups of diffraction patterns or even data sets before analysing the report. Checking the indexing consistency runs dials.cosym as part of the scaling, using an algorithm for Patterson group symmetry determination for cases with indexing ambiguity (Gildea & Winter, 2018). Similarly, the filtering that can be accessed through the GUI allows the automatic removal of data sets or frames that would significantly reduce the CC1/2 of the overall data set. A protocol for running dials.symmetry to identify the Laue group symmetry before scaling has also been added to scipion-ed-dials in version 3!1.0.1. Future work includes adding full support for these steps through the xia2.multiplex tool.
Important indicators for judging the data quality can be found in the result viewer as well as in the HTML file, with the latter providing more attractive formatting. The primary quality indicators are CC1/2, I/σ(I), Rmeas, Rpim (Karplus & Diederichs, 2015) and completeness. Statistics for each resolution shell as well as the overall statistics are presented both in the results viewer and in the HTML output.
Finally, exporting to other file formats for further processing outside the Scipion-ED pipeline is possible, with available parameters determined by the desired file format.
8. Illustrative example of Scipion-ED data processing
The processing of the tetragonal lysozyme data sets used as examples in the description above was carried out to compare merging strategies regarding the structure solution and P43212, No. 96). Two of the 47 data sets were used for initial determination of suitable parameters, such as the rotation axis and detector distance used in the import step and resolution ranges used in spot finding. The resulting workflow, from importing to scaling of individual data sets, was then copied and reused for the remaining 45 data sets.
of tetragonal lysozyme (space groupThirty-five data sets could be processed in this way, either directly (33 data sets) or after modifications of the spot-finding parameters as described above. Five of the remaining 12 data sets could not be imported at all, while seven were found to have inherent problems even after optimization and were eventually discarded. The failure to import images is presumed to be the result of file corruption during conversion, while those that could not be used even after optimization were probably subject to beam damage.
Two strategies were devised for the merging of data sets. In strategy 1, data sets with the most favourable overall merging statistics with regard to the three criteria CC1/2 > 0.8, I/σ(I) > 2 and Rmeas < 0.60 were merged. Overall values were selected because they indicate the average data quality, with the specific numbers chosen according to experience from similar data sets. The data sets were selected manually on the basis of inspection of the output. In strategy 2, all data sets were merged using a 2.0 Å resolution cut-off, emulating a strategy where no particular consideration is given to the choice of data sets for merging. A scaled and merged mtz file for each strategy was exported for further structure solution and Final overall statistics are presented in Table 1. The lack of completeness despite 25-fold and 43-fold multiplicity could be the result of preferred orientation.
|
et al., 1996) was performed through Phaser (McCoy et al., 2007) to obtain an initial model for each strategy. was performed in phenix.refine (Afonine et al., 2012) with five cycles, grouped B factors and a resolution cut-off at 2.6 Å. The final model was validated using MolProbity through the Phenix suite (Chen et al., 2010; Williams et al., 2018). Strategy 1 had the lowest completeness (73.4%) but the highest overall CC1/2 (0.921) and a 2.610 Å resolution based on CC1/2 > 0.330, while strategy 2 had 2.987 Å resolution. At the same time, strategy 2 resulted in a higher overall completeness of 86.9%. We found that, despite the differences in completeness, strategy 1 resulted in a slightly lower Rwork/Rfree. However, a higher number of ordered solvent molecules could be modelled in the map obtained from strategy 2 compared with strategy 1 (13 compared with two water molecules respectively; Table 2). Moreover, the electrostatic potential map for strategy 2 has residue side chains that are better defined and improved continuity along the peptide backbone compared with strategy 1 (Fig. 9). These results indicate that merging all data sets is advantageous for resolving more details in the electrostatic potential map, despite the reduced data quality of the high-resolution reflections. This is in agreement with previously reported studies, where increased redundancy resulted in a more detailed model (Xu et al., 2018).
based on the lysozyme structure PDB (Vaney
|
9. Conclusions
Scipion is a versatile tool for data processing, with clear visualization and simple sharing of workflows. These strengths have been brought to 3D ED through the Scipion-ED base and scipion-ed-dials plugins. Novice users can benefit from the presentation of common parameters, while experienced users still have access to all parameters found through the command line. All users can benefit from simple reuse of successful workflows and comparing the results of different processing. Such a comparison was made between two different strategies for merging data, where more details could be resolved in the electrostatic potential map by using all available data instead of only the highest quality data.
10. Availability
The scipion-ed-dials module depends on having DIALS available in the path. The most recent version can be found from the DIALS web site at https://dials.github.io/installation.html. Installing the Scipion-ED base plugin and scipion-ed-dials also requires a Python 3 environment with pip, such as one set up with Anaconda or Miniconda. Python 3.8 is recommended. In that environment, installation is done with the one line pip install scipion-ed scipion-ed-dials. All dependencies except DIALS itself will then automatically be installed as well. The program is open source under a GPL-3.0 licence, and the source code for Scipion-ED and plugins can be found at https://github.com/scipion-ed. Contributions from the community such as bug reports, fixes, suggestions and improvements are welcome.
The raw data used for the examples are available at https://doi.org/10.5281/zenodo.6037632.
Supporting information
Link https://doi.org/10.5281/zenodo.6037632
Raw data used in processing
Supporting information file. DOI: https://doi.org/10.1107/S1600576722002758/yr5085sup1.pdf
Acknowledgements
The authors thank David Waterman for his kind support with DIALS.
Funding information
The project is supported by the Swedish Research Council (2017-05333, HX; 2019-00815, XZ), the Knut and Alice Wallenberg Foundation (2018.0237, XZ), and the Science for Life Laboratory through the technique development grant (MicroED@SciLifeLab).
References
Abrishami, V., Ilca, S. L., Gomez-Blanco, J., Rissanen, I., de la Rosa-Trevín, J. M., Reddy, V. S., Carazo, J.-M. & Huiskonen, J. T. (2021). Prog. Biophys. Mol. Biol. 160, 43–52. Web of Science CrossRef CAS PubMed Google Scholar
Afonine, P. V., Grosse-Kunstleve, R. W., Echols, N., Headd, J. J., Moriarty, N. W., Mustyakimov, M., Terwilliger, T. C., Urzhumtsev, A., Zwart, P. H. & Adams, P. D. (2012). Acta Cryst. D68, 352–367. Web of Science CrossRef CAS IUCr Journals Google Scholar
Chen, V. B., Arendall, W. B., Headd, J. J., Keedy, D. A., Immormino, R. M., Kapral, G. J., Murray, L. W., Richardson, J. S. & Richardson, D. C. (2010). Acta Cryst. D66, 12–21. Web of Science CrossRef CAS IUCr Journals Google Scholar
Cichocka, M. O., Ångström, J., Wang, B., Zou, X. & Smeets, S. (2018). J. Appl. Cryst. 51, 1652–1661. Web of Science CrossRef ICSD CAS IUCr Journals Google Scholar
Clabbers, M. T. B., van Genderen, E., Wan, W., Wiegers, E. L., Gruene, T. & Abrahams, J. P. (2017). Acta Cryst. D73, 738–748. Web of Science CrossRef IUCr Journals Google Scholar
Clabbers, M. T. B., Holmes, S., Muusse, T. W., Vajjhala, P. R., Thygesen, S. J., Malde, A. K., Hunter, D. J. B., Croll, T. I., Flueckiger, L., Nanson, J. D., Rahaman, M. H., Aquila, A., Hunter, M. S., Liang, M., Yoon, C. H., Zhao, J., Zatsepin, N. A., Abbey, B., Sierecki, E., Gambin, Y., Stacey, K. J., Darmanin, C., Kobe, B., Xu, H. & Ve, T. (2021). Nat. Commun. 12, 2578. Web of Science CrossRef PubMed Google Scholar
Conesa Mingo, P., Gutierrez, J., Quintana, A., de la Rosa Trevín, J. M., Zaldívar-Peraza, A., Cuenca Alba, J., Kazemi, M., Vargas, J., del Cano, L., Segura, J., Sorzano, C. O. S. & Carazo, J. M. (2018). Protein Sci. 27, 269–275. Web of Science CrossRef CAS PubMed Google Scholar
Gemmi, M., Mugnaioli, E., Gorelik, T. E., Kolb, U., Palatinus, L., Boullay, P., Hovmöller, S. & Abrahams, J. P. (2019). ACS Cent. Sci. 5, 1315–1329. Web of Science CrossRef CAS PubMed Google Scholar
Genderen, E. van, Clabbers, M. T. B., Das, P. P., Stewart, A., Nederlof, I., Barentsen, K. C., Portillo, Q., Pannu, N. S., Nicolopoulos, S., Gruene, T. & Abrahams, J. P. (2016). Acta Cryst. A72, 236–242. Web of Science CSD CrossRef IUCr Journals Google Scholar
Gildea, R. J. & Winter, G. (2018). Acta Cryst. D74, 405–410. Web of Science CrossRef IUCr Journals Google Scholar
Gómez-Blanco, J., de la Rosa-Trevín, J. M., Marabini, R., del Cano, L., Jiménez, A., Martínez, M., Melero, R., Majtner, T., Maluenda, D., Mota, J., Rancel, Y., Ramírez-Aportela, E., Vilas, J. L., Carroni, M., Fleischmann, S., Lindahl, E., Ashton, A. W., Basham, M., Clare, D. K., Savage, K., Siebert, C. A., Sharov, G. G., Sorzano, C. O. S., Conesa, P. & Carazo, J. M. (2018). J. Struct. Biol. 204, 457–463. Web of Science PubMed Google Scholar
Gorelik, T. E., van de Streek, J., Kilbinger, A. F. M., Brunklaus, G. & Kolb, U. (2012). Acta Cryst. B68, 171–181. Web of Science CSD CrossRef CAS IUCr Journals Google Scholar
Gruene, T., Wennmacher, J. T. C., Zaubitzer, C., Holstein, J. J., Heidler, J., Fecteau-Lefebvre, A., De Carlo, S., Müller, E., Goldie, K. N., Regeni, I., Li, T., Santiso-Quinones, G., Steinfeld, G., Handschin, S., van Genderen, E., van Bokhoven, J. A., Clever, G. H. & Pantelic, R. (2018). Angew. Chem. Int. Ed. 57, 16313–16317. Web of Science CSD CrossRef ICSD CAS Google Scholar
Jiang, J., Jorda, J. L., Yu, J., Baumes, L. A., Mugnaioli, E., Diaz-Cabanas, M. J., Kolb, U. & Corma, A. (2011). Science, 333, 1131–1134. Web of Science CrossRef ICSD CAS PubMed Google Scholar
Jones, C. G., Martynowycz, M. W., Hattne, J., Fulton, T. J., Stoltz, B. M., Rodriguez, J. A., Nelson, H. M. & Gonen, T. (2018). ACS Cent. Sci. 4, 1587–1592. Web of Science CSD CrossRef CAS PubMed Google Scholar
Kabsch, W. (2010). Acta Cryst. D66, 125–132. Web of Science CrossRef CAS IUCr Journals Google Scholar
Kabsch, W. (2016). XDS Program Package, https://xds.mpimf-heidelberg.mpg.de/. Google Scholar
Karplus, P. A. & Diederichs, K. (2015). Curr. Opin. Struct. Biol. 34, 60–68. Web of Science CrossRef CAS PubMed Google Scholar
Kolb, U., Gorelik, T. E., Mugnaioli, E. & Stewart, A. (2010). Polym. Rev. 50, 385–409. Web of Science CrossRef CAS Google Scholar
Lanza, A., Margheritis, E., Mugnaioli, E., Cappello, V., Garau, G. & Gemmi, M. (2019). IUCrJ, 6, 178–188. Web of Science CrossRef CAS PubMed IUCr Journals Google Scholar
Llopart, X., Ballabriga, R., Campbell, M., Tlustos, L. & Wong, W. (2007). Nucl. Instrum. Methods Phys. Res. A, 581, 485–494. Web of Science CrossRef CAS Google Scholar
Martínez-Franco, R., Moliner, M., Yun, Y., Sun, J., Wan, W., Zou, X. & Corma, A. (2013). Proc. Natl Acad. Sci. USA, 110, 3749–3754. Web of Science PubMed Google Scholar
McCoy, A. J., Grosse-Kunstleve, R. W., Adams, P. D., Winn, M. D., Storoni, L. C. & Read, R. J. (2007). J. Appl. Cryst. 40, 658–674. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nannenga, B. L. & Gonen, T. (2016). Curr. Opin. Struct. Biol. 40, 128–135. Web of Science CrossRef CAS PubMed Google Scholar
Parkhurst, J. M., Brewster, A. S., Fuentes-Montero, L., Waterman, D. G., Hattne, J., Ashton, A. W., Echols, N., Evans, G., Sauter, N. K. & Winter, G. (2014). J. Appl. Cryst. 47, 1459–1465. Web of Science CrossRef CAS IUCr Journals Google Scholar
Potterton, L., Agirre, J., Ballard, C., Cowtan, K., Dodson, E., Evans, P. R., Jenkins, H. T., Keegan, R., Krissinel, E., Stevenson, K., Lebedev, A., McNicholas, S. J., Nicholls, R. A., Noble, M., Pannu, N. S., Roth, C., Sheldrick, G., Skubak, P., Turkenburg, J., Uski, V., von Delft, F., Waterman, D., Wilson, K., Winn, M. & Wojdyr, M. (2018). Acta Cryst. D74, 68–84. Web of Science CrossRef IUCr Journals Google Scholar
Rosa-Trevín, J. M. de la, Quintana, A., del Cano, L., Zaldívar, A., Foche, I., Gutiérrez, J., Gómez-Blanco, J., Burguet-Castell, J., Cuenca-Alba, J., Abrishami, V., Vargas, J., Otón, J., Sharov, G., Vilas, J. L., Navas, J., Conesa, P., Kazemi, M., Marabini, R., Sorzano, C. O. S. & Carazo, J. M. (2016). J. Struct. Biol. 195, 93–99. Web of Science PubMed Google Scholar
Sharov, G., Morado, D. R., Carroni, M. & de la Rosa-Trevín, J. M. (2021). Acta Cryst. D77, 403–410. Web of Science CrossRef IUCr Journals Google Scholar
Shi, D., Nannenga, B. L., Iadanza, M. G. & Gonen, T. (2013). eLife, 2, e01345. Web of Science CrossRef PubMed Google Scholar
Smeets, S., McCusker, L. B., Baerlocher, C., Mugnaioli, E. & Kolb, U. (2013). J. Appl. Cryst. 46, 1017–1023. Web of Science CrossRef CAS IUCr Journals Google Scholar
Smeets, S., Wang, B., Cichocka, M. O., Ångström, J. & Wan, W. (2017). Instamatic, https://doi.org/10.5281/zenodo.1090389. Google Scholar
Smeets, S., Wang, B. & Hogenbirk, E. (2021). instamatic-dev/instamatic: 1.7.0, https://doi.org/10.5281/zenodo.5175957. Google Scholar
Smeets, S., Xie, D., McCusker, L. B., Baerlocher, C., Zones, S. I., Thompson, J. A., Lacheen, H. S. & Huang, H.-M. (2014). Chem. Mater. 26, 3909–3913. Web of Science CSD CrossRef CAS Google Scholar
Sorzano, C. O. S., Marabini, R., Velázquez-Muriel, J., Bilbao-Castro, J. R., Scheres, S. H. W., Carazo, J. M. & Pascual-Montano, A. (2004). J. Struct. Biol. 148, 194–204. Web of Science CrossRef PubMed CAS Google Scholar
Su, J., Kapaca, E., Liu, L., Georgieva, V., Wan, W., Sun, J., Valtchev, V., Hovmöller, S. & Zou, X. (2014). Microporous Mesoporous Mater. 189, 115–125. Web of Science CrossRef ICSD CAS Google Scholar
Vaney, M. C., Maignan, S., Riès-Kautt, M. & Ducruix, A. (1996). Acta Cryst. D52, 505–517. CrossRef CAS Web of Science IUCr Journals Google Scholar
Wang, B., Zou, X. & Smeets, S. (2019). IUCrJ, 6, 854–867. Web of Science CSD CrossRef ICSD CAS PubMed IUCr Journals Google Scholar
Wang, Y., Yang, T., Xu, H., Zou, X. & Wan, W. (2018). J. Appl. Cryst. 51, 1094–1101. Web of Science CrossRef ICSD CAS IUCr Journals Google Scholar
Waterman, D. G. (2021). MyD88TIR Small Wedges, https://dials.github.io/documentation/tutorials/3DED/MyD88.html. Google Scholar
Williams, C. J., Headd, J. J., Moriarty, N. W., Prisant, M. G., Videau, L. L., Deis, L. N., Verma, V., Keedy, D. A., Hintze, B. J., Chen, V. B., Jain, S., Lewis, S. M., Arendall, W. B., Snoeyink, J., Adams, P. D., Lovell, S. C., Richardson, J. S. & Richardson, D. C. (2018). Protein Sci. 27, 293–315. Web of Science CrossRef CAS PubMed Google Scholar
Winter, G., Waterman, D. G., Parkhurst, J. M., Brewster, A. S., Gildea, R. J., Gerstel, M., Fuentes-Montero, L., Vollmar, M., Michels-Clark, T., Young, I. D., Sauter, N. K. & Evans, G. (2018). Acta Cryst. D74, 85–97. Web of Science CrossRef IUCr Journals Google Scholar
Xu, H. & Bengtsson, V. E. G. (2022). MicroED Data Collected From Tetragonal Lysozyme, https://doi.org/10.5281/zenodo.6037632. Google Scholar
Xu, H., Lebrette, H., Clabbers, M. T. B., Zhao, J., Griese, J. J., Zou, X. & Högbom, M. (2019). Sci. Adv. 5, eaax4621. Web of Science CrossRef PubMed Google Scholar
Xu, H., Lebrette, H., Yang, T., Srinivas, V., Hovmöller, S., Högbom, M. & Zou, X. (2018). Structure, 26, 667–675.e3. Web of Science CrossRef CAS PubMed Google Scholar
Yamashita, K., Hirata, K. & Yamamoto, M. (2018). Acta Cryst. D74, 441–449. Web of Science CrossRef IUCr Journals Google Scholar
Yonekura, K., Kato, K., Ogasawara, M., Tomita, M. & Toyoshima, C. (2015). Proc. Natl Acad. Sci. USA, 112, 3368–3373. Web of Science CrossRef CAS PubMed Google Scholar
Zhang, Y.-B., Su, J., Furukawa, H., Yun, Y., Gándara, F., Duong, A., Zou, X. & Yaghi, O. M. (2013). J. Am. Chem. Soc. 135, 16336–16339. Web of Science CSD CrossRef CAS PubMed Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.