research papers
Radial spin echo small-angle neutron scattering method: concept and performance
aDelft University of Technology, Faculty of Applied Sciences, The Netherlands
*Correspondence e-mail: w.g.bouwman@tudelft.nl
A novel spin echo small-angle neutron scattering (SESANS) concept based on a rotationally symmetric magnetic field geometry is introduced. The proposed method is similar to the conventional linear SESANS technique but uses longitudinal precession fields and field gradients in a radial direction, as typically found in neutron spin echo (NSE) spectrometers. Radial SESANS could thus be implemented as an add-on to NSE setups. The neutron trajectory through the instrument is encoded with the help of radial gradients generated by radial shifters, which are coils placed in the beam area similar to Fresnel coils. The present work introduces the setup of the instrument and explores its performance and the relationship between the encoded momentum transfer and the precession angle. The results indicate that radial SESANS is only sensitive to scattering along the radial direction and thus measures the projected correlation function along this direction as a function of the spin echo length, defined similarly to linear SESANS. For an evaluation of the performance of the setup, the case of scattering from solid spheres is considered and the results calculated for the radial and linear SESANS cases are compared. Also discussed is the implementation of the radial magnetic field geometry in spin echo modulated small-angle neutron scattering.
Keywords: small-angle neutron scattering; polarized neutrons; spin echo small-angle neutron scattering; Larmor labelling.
1. Introduction
In neutron scattering, the energy and momentum of the neutron beam are usually measured both before and after scattering in order to determine the energy or momentum transfer at the sample. Achieving a high accuracy of these measurement parameters requires high collimation and monochromatization which, in turn, leads to a dramatic loss in beam intensity and thus limits the practically achievable resolution. This limitation can be overcome by neutron spin echo techniques. These use the Larmor precession of polarized neutrons in a magnetic field to measure directly the transfer of energy ω or momentum Q [Q = (4π/λ)sin(θ/2), where θ is the scattering angle and λ is the wavelength of the incident radiation] at the sample without the need to determine these quantities independently for the incoming and scattered neutron beams. In this way, the accuracy with which ω or Q are determined becomes independent of beam characteristics, and very high resolutions can be reached without the prohibiting low-intensity penalty of other neutron scattering methods.
1.1. Basics of neutron spin echo spectroscopy
Neutron spin echo (NSE) spectroscopy was first introduced by Mezei (1972) to measure the in In an NSE spectrometer, a polarized neutron beam traverses two equal magnetic precession regions in which it experiences Larmor precession in opposite directions. A simplified NSE setup is shown in Fig. 1(a). The π/2 spin flipper at the beginning of the first precession region turns the polarization of the neutron beam P perpendicular to the magnetic field B. This induces Larmor precession with the characteristic Larmor frequency ωL = γB, where γ = 1.832 × 108 s−1 T−1 is the neutron gyromagnetic ratio. For a neutron beam propagating with a speed v over a path of length ℓ, where a constant magnetic field of strength B is applied, the accumulated precession phase φ is given by (Mezei, 1980c)
with λ the wavelength, m the neutron mass, h the Planck constant and c = 4.636 × 1014 T−1 m−2. The precession angle φ is thus proportional to both the neutron beam wavelength and the magnetic field integral (along the neutron trajectory), which in our simplified case (homogeneous magnetic field, highly collimated, i.e. non-divergent, neutron beam) reduces to the product of B and ℓ.
A π flipper at the symmetry point of the setup, which is close to the sample position, reverses the precession direction in the second field area. Consequently, if the two precession regions are identical, the precession angles before and after the sample cancel each other. This leads to the spin echo condition Δφ = φincoming − φscattered = 0 at the second π/2 flipper, which is positioned at the end of the second precession region in front of the analyser and the detector. This flipper stops the precession and turns P in the direction of the magnetic field and thus of the analyser, so that ideally the maximum intensity is recovered at the detector (Mezei, 1980c; Mezei et al., 2003).
Inelastic scattering from the sample breaks the symmetry of the setup as the ω modifies the speed, and thus the wavelength, of the scattered neutron beam. As a result, the precession phases accumulated before and after the sample are no longer equal to each other, leading to a non-zero total precession phase Δφ and a reduction in the detected intensity. In the limit, where the at the sample is much smaller than the energy of the incoming neutron beam, Δφ is directly proportional to ω,
where the proportionality factor τ is the Fourier time (Mezei, 1980c). The component of the beam polarization P transmitted by the analyser is proportional to . Thus, the net precession angle Δφ is reflected in the normalized spin echo signal determined by integrating over all possible energy transfers, which is equal to the intermediate scattering function (Mezei, 1980c):
where S(Q, ω) = d2Σ/dQdω, with Σ the total scattering of the sample, and = is the static In other words, NSE measures the real (cosine) part of the ω Fourier transform of S(Q, ω) and thus the τ dependence of the correlation function (Gähler et al., 1996; Mezei et al., 2003).
1.2. Linear SESANS
The same principles of Larmor precession and neutron spin echo can be applied in experiments with i.e. for ω = 0, in which case S(Q, ω) reduces to S(Q) = dΣ(Q)/dQ] to measure the scattering angle and thus the momentum transfer. This labelling of a neutron beam trajectory by the Larmor precession phase (Pynn, 1978, 1980) has been applied for small-angle neutron scattering (SANS), neutron reflectivity and neutron diffraction (Rekveldt et al., 2003), leading to an increase in resolution by several orders of magnitude compared with conventional neutron scattering methods.
[Encoding the neutron trajectory using the Larmor precession is possible by introducing specially shaped precession regions with inclined front and end faces, as shown in Fig. 1(b). This is achieved by adding linear field gradients that span the whole beam Analogously to NSE, the neutron polarization undergoes Larmor precession in opposite directions in two precession regions before and after the sample. Furthermore, the magnetic field configuration and arrangement of the gradients is such that the spin echo condition is satisfied in the absence of scattering.
The accumulated total precession phase averaged over the neutron beam now also depends on the linear gradient, which leads to different phases for different trajectories through the instrument. The vertically inclined field boundaries lead to a linear relation between φ and the vertical transmission angle θx of the neutron beam. If there is scattering at the sample, the transmission angle changes and, in the small-angle scattering approximation, the difference in transmission angles Δθ = θincoming − θscattered directly yields the momentum transfer for Therefore, the net precession angle encodes the momentum transfer along the linear gradient Qx (Rekveldt et al., 2003, 2005; Bouwman et al., 2000),
where θ0 is the inclination angle of the field boundaries. The quantity δx is the spin echo length, which is proportional to λ2 and the magnetic field integral.
In the following we focus on isotropic ) realization of this method. We designate the geometry of Fig. 1(b) as linear SESANS. As the measurements are performed in the direct beam it is convenient to consider the average spin echo polarization,
and on the spin echo small-angle neutron scattering (SESANS) (Rekveldt, 1996In the case of scattering from a sample with total scattering Σ and thickness t, PSES is related to the SESANS correlation function G(δx),
In the small-angle approximation, the total
is given bywith k0 = 2π/λ and Ω the probed solid angle. This description includes the fraction of the neutron beam that does not scatter, as well as all scattering including multiple scattering (Rekveldt et al., 2003).
The normalized SESANS correlation function G(δx) is given by
Equations (6) and (8) show that, similarly to NSE, SESANS measures a function which involves the Fourier transform of the scattering dΣ(Q)/dΩ. However, the integration in this case is with respect to the momentum transfer, which is a two-dimensional vector in the detector plane. Consequently, for isotropic density distributions ρ(r) the measured G(δx) and dΣ(Q)/dΩ are connected by a Hankel transform (Krouglov, de Schepper et al., 2003; Andersson et al., 2008; Kohlbrecher & Studer, 2017), as illustrated in Fig. 2. G(δx) is the projection of the normalized density autocorrelation function γ(r) along the neutron path (Andersson et al., 2008; Krouglov, de Schepper et al., 2003; Kohlbrecher & Studer, 2017),
with z the coordinate parallel to the beam propagation, x the coordinate along the magnetic gradients [as shown in Fig. 1(b)] and r = (x2 + z2)1/2.
The described SESANS setup is not sensitive in the y direction and only measures correlations along x, the direction of the magnetic field integral gradient. In the second step in equation (9), a coordinate transformation from x, z to x, r is performed, and the resulting formula shows that G(δx) is an Abel transform of γ(r) (Krouglov, de Schepper et al., 2003).
The first dedicated SESANS instrument was built at TU Delft (Rekveldt, 1996) and uses transverse precession fields, i.e. perpendicular to the optical axis z, which are generated by permanent magnets. SESANS finds a broad range of applications such as in science (Krouglov, Bouwman et al., 2003, 2005; Li et al., 2011; Washington et al., 2014; van Gruijthuijsen et al., 2014, 2018) or food science (Bouwman, 2021). Most SESANS instruments access spin echo lengths spanning three orders of magnitude from 10 nm up to 20 µm. The maximum length that can be probed is two orders of magnitude larger than that in conventional SANS. Besides the increased resolution, a significant advantage is the simple consideration of multiple scattering (Rekveldt et al., 2003). An interesting feature, especially for the communication of the data to non-scattering experts, is the real-space character of the direct measurements (Bouwman et al., 2008).
A more recent variation in the technique is spin echo modulation small-angle neutron scattering (SEMSANS) (Bouwman et al., 2009, 2011; Sales et al., 2015; Strobl et al., 2015). A SEMSANS setup consists of only two precession devices with different gradients that create a spatial modulation of intensity at a detector. All spin manipulations can be performed before the sample, which gives more freedom to work with magnetic samples (Li et al., 2021) or sample environments. SEMSANS can also be combined with normal SANS to probe a much longer range of length scales (Schmitt et al., 2020).
1.3. Introducing radial SESANS
When it was first proposed to use the neutron spin echo principle for structural investigations, it was considered that the method would deliver the Fourier transform of dΣ(Q)/dΩ (Pynn, 1978, 1980; Gähler et al., 1996) closely following the mathematical concepts of NSE. This would imply that linear SESANS would measure the three-dimensional autocorrelation function directly (Gähler et al., 1998). However, it turns out that only one direction, the one along the magnetic field gradient, is probed. This leads to a two-dimensional projection of the autocorrelation function and to the Hankel transform between G(δx) and dΣ(Q)/dΩ discussed above.
A method for direct measurement of the density autocorrelation function would also be of interest because it would facilitate the comparison between SANS and SESANS data sets. As a key feature, such a SESANS method should be able to measure Q, the modulus of the total momentum transfer, not just the one component along a certain direction. For this purpose one might consider introducing radially symmetric magnetic field precession regions, which would allow for measuring correlations independent of a specific direction. This concept is discussed in the following and is referred to as radial SESANS. In order to respect the radial symmetry of the setup, we consider longitudinal precession fields with radially symmetric gradients as shown schematically in Fig. 1(c). This radial symmetry is also reflected in the precession angle which, as discussed in the following section, depends on the radial distance of the neutron path from the optical axis.
Such a setup was first discussed by Zhao (2001) with the aim of developing a SESANS method where the density distribution function would be the simple Fourier transform of dΣ(Q)/dΩ, similar to NSE spectroscopy. The radial SESANS setup discussed by Zhao uses longitudinal magnetic fields created by solenoids similar to those of NSE spectrometers with in-beam gradient coils. Therefore, it can be considered as a possible add-on for existing NSE spectrometers. In NSE, Fresnel coils (Mezei, 1980a; Monkenbusch, 1990), shown schematically in Fig. 3(a), are used to correct the magnetic field integral inhomogeneities inherent to divergent beams with large cross sections. Similarly, SESANS could use shifter coils, linear or radial [see Figs. 3(b) and 3(c), respectively], not to correct for magnetic field inhomogeneities but to encode the neutron trajectory by adding a shift to the precession angle depending on a specific neutron trajectory. Schematic drawings of the resulting configurations are shown in Figs. 1(b) and 1(c) for linear and radial SESANS, respectively.
In this paper we investigate the realization conditions and the performance of a radial SESANS setup for small-angle neutron scattering. Our calculations are based on parameters which are compatible with state-of-the-art NSE spectrometers, such as the IN15 instrument at the Institute Laue–Langevin (Schleger et al., 1999). The focus is on the measured momentum transfer and the obtained correlation function.
Our findings show that in radial SESANS the labelling of the trajectories, and thus of the momentum transfer, is along the radial directions. However, it is not possible to obtain the total momentum transfer from the measured signal as radial SESANS is also sensitive to only one component of the momentum transfer vector. Thus, in this case we also obtain a projected correlation function along the radius, which is similar to linear SESANS. This implies that, regardless of the symmetry, radial or linear, SESANS probes correlation along only one direction, which is the direction of the field gradient. We discuss the implications of this result for other scattering geometries.
2. Radial SESANS
As discussed above, when considering the implementation of SESANS on NSE spectrometers, where the magnetic fields are generated by solenoids and their direction is along the optical axis of the instrument (i.e. longitudinal), there are two possibilities to trace the neutron trajectory through the device, either with linear shifters or with radial shifters, as shown in Figs. 3(b) and 3(c).
SESANS with linear shifters, shown schematically in Fig. 1(b), satisfies the spin echo condition for the unscattered neutron beam, and the labelling of the scattering angle or momentum transfer is along the direction of the magnetic field integral gradient. Consequently, the combination of linear shifters and longitudinal precession fields reproduces the conventional linear SESANS technique and may be considered as an add-on option for NSE spectrometers.
The SESANS method discussed here uses radial shifters, and the resulting magnetic field integral is therefore rotationally symmetric about the optical axis. In the following we evaluate the performance and capabilities of radial SESANS assuming that the magnetic field configuration of the host NSE spectrometer is ideal, i.e. the magnetic field integral is the same for all possible neutron trajectories before and after the sample. This is technically achievable using correction elements, in particular Fresnel coils (Monkenbusch, 1990). Thus, the host NSE spectrometer ideally satisfies the spin echo condition φ = 0 for both the non-scattered and the elastically scattered (ω = 0) neutron beams considered here. For this reason, in the following we will make an abstraction of the host instrument magnetic field configuration and will consider solely the effect of additional coils, such as linear or radial shifters, on φ for both the non-scattered and the elastically scattered neutron beams.
Ideally, Fresnel coils can be considered as consisting of concentric current loops, as shown schematically in Fig. 3(a), generating a magnetic field integral that counterbalances the intrinsic r2 dependence of the magnetic field integral produced by solenoids (Mezei, 1980a; Monkenbusch, 1990). In this way, NSE spectrometers can reach long Fourier times while keeping large beam cross sections and thus without sacrificing their data acquisition rate.
Shifters are similar to Fresnel coils but they generate a magnetic field integral proportional to a characteristic distance, e.g. along x as in Fig. 3(b) or along the radius as in Fig. 3(c). Linear shifters as in Fig. 3(b) were introduced in the early days of NSE spectroscopy to produce linear gradients in the magnetic field integral that can map the Q-dependent energy (dispersion) of collective excitations (Mezei, 1980b).
The focus here is on radial shifters, the magnetic field integral of which varies linearly with the radius. In this case the resulting precession phase for neutrons crossing a radial shifter at a radius r is given by
with μ0 the magnetic permeability, nW the winding density, i.e. the number of wires per unit length, R the outer radius of the radial shifter (r < R) and I the current in the coil. From now on we will ignore the term KR since it will in all configurations be compensated by the same term in another radial shifter with opposite sign. All tuning parameters are summarized in the constant K. For example, for a monochromatic neutron beam with λ = 10 Å and a shifter with nW = 2 mm−1 and I = 10 A, K = 11651 m−1.
In the following we assume that the neutron beam is perfectly monochromated. However, in the absence of scattering the spin echo condition is wavelength independent, and for this reason a wavelength distribution does not affect the performance of the setup but leads only to a distribution of spin echo lengths (Rekveldt et al., 2005). In SEMSANS this distribution would decrease the amplitude for the higher-order modulations.
In our calculations the beam divergence is defined by the diaphragms. For an improved data acquisition rate one could envisage focusing the beam at the sample position. This would be possible by adequate design of the neutron delivery system, e.g. using a focusing mirror, as foreseen on IN15 (Schleger et al., 1999).
The performance of SESANS as given by equation (10) is independent of the main magnetic field from the host NSE instrument, which in principle could stay constant during the SESANS measurements. In this way it would be easy to disentangle the SESANS signal from any The latter would reduce the amplitude of the modulation and could be determined by NSE measurements with zero current in the shifter coils.
Fig. 4 provides a schematic illustration of the linear and radial SESANS setups discussed here, which are conceptually equivalent to those of Figs. 1(b) and 1(c). The precession field areas are positioned on each spectrometer arm symmetrically around the π flipper, which is in the centre of the setup and next to the pinhole at the sample position. The precession fields are created by coils and thus point towards the optical axis z. The labelling of the neutron beam trajectories is performed by two pairs of shifters, one at each arm of the setup, and the shifters of each pair are at a distance ℓ1 apart from each other. Furthermore, the inner shifters, which are positioned next to the pinhole at the sample position, are at a distance ℓ2 from it. Thus, the total distance between the outer shifters and the pinhole is L = ℓ1 + ℓ2. The arrows indicate the direction of the electric currents in the shifters. Ideally, both the π flipper and the pinhole should be positioned at the geometric centre of the setup. However, as the pinhole has finite dimensions its exact positioning will not be critical for the final performance of the setup.
2.1. Definition of neutron beam trajectories
In the following we focus on the performance of radial SESANS and we start by defining the neutron beam trajectory coordinates, expressing them in terms of the beam's crossing points with the four shifters (Sh) and the pinhole (S), as illustrated in Fig. 5. For this purpose we will use cylindrical coordinates, which are concordant with the symmetry of the setup. The coordinate system is defined such that the z axis coincides with the optical axis of the instrument and the pinhole is located at the origin. Without any loss of generality, the crossing points are given by
Here ri is the radius of the crossing point at shifter Shi or at the pinhole, and αi are the corresponding angles in the xy plane, as shown in Fig. 6.
In the absence of scattering, two points are sufficient to define the trajectory through the whole setup. Thus, r1, r2 and r3 can be expressed as a function of the coordinates at the sample S and the fourth shifter Sh4:
with αS4 = αS − α4 and L = ℓ1 + ℓ2. In the case where , i.e. when the radius of the beam at the sample position is small compared with that at the shifters, we can simplify the above expressions using the Taylor expansion:
2.2. Neutron beam trajectory and Larmor precession
In general, the total precession angle Δφ is equal to the difference between the precession angle before and after the π flipper. In this SESANS setup, Δφ depends only on the contributions of the four shifters (φi, i = 1,…, 4) that encode the neutron trajectory, leading to
Here the relative orientation of the electric currents in the shifters, which we will designate in the following by their signs (+ and −), affects the sign of the corresponding φi. In the absence of scattering, the linear SESANS (+−, +−) configuration shown in Fig. 4(a) satisfies the spin echo condition for all beam sizes and divergences.
The case of radial SESANS, however, is more restrictive as the beam dimensions at the sample position have a significant impact on the performance of the setup. This is most prominent for the (++, ++) configuration [equivalent to Figs. 1(b) and 1(c) in the report by Zhao (2001)], the net precession angle of which can be calculated using the approximations of equations (19)–(21):
This result can be understood from the geometry of the precession regions. Considering the case of αS4 = π/2 or 3π/2 in Fig. 6 will result in a symmetric situation for the radii of the trajectory in the first arm as in the second arm. In that case we expect an echo, which is illustrated mathematically by the fact that in those cases = 0. On the other hand, when αS4 = 0 or π, then the asymmetry will be maximal. Only for rS = 0 will there be an echo, as sketched in Fig. 7(a). This implies that this configuration satisfies the spin echo condition only for infinitesimally small pinholes, i.e. when the neutron trajectory passes exactly though rS = 0, and is very sensitive to deviations from it. Any realistic pinhole would therefore lead to significant deviations from the spin echo condition and a loss of the spin echo modulation. This is a severe drawback and for this reason, in the following, we will discard this configuration and focus on the performance of the (+−, −+) setup. In that case, and in the presence of a pinhole with radius p at the sample position, so that 0 ≤ rS ≤ p, following equations (10) and (22) the net precession angle can be written assuming the approximations of equations (19)–(21):
This result can also be understood from the geometry of the setup as sketched in Fig. 7(b) by considering only the most asymmetric case when αS4 = 0 or π. For trajectories where the signs of the x components of the radii of the first two shifters are both opposite to those of the last two shifters this will always result in an echo situation. The path length through either of the two precession regions is only dependent on the angle of the trajectory and not on its position. This implies that, in the absence of scattering, the spin echo condition is satisfied in this configuration for any small pinhole of finite size.
The resulting NSE polarization in the most general case, beyond the small sample pinhole approximation, can be calculated by taking all possible neutron trajectories into account and is given by
where p and a are the maximum pinhole and shifter radii, respectively, α = αS4, and the net precession angle Δφ is given by equations (24) and (16)–(18).
Fig. 8(a) depicts the effect of the pinhole radius on PNSE, as obtained by numerical integration for a = 20 mm, λ = 10 Å and different spin echo lengths δ. A radius of 20 mm is a reasonable assumption; smaller values would of course be possible but would also lead to a dramatic decrease in the data acquisition rate.
Only an infinitesimally small pinhole (p = 0) leads to PNSE = 1, thus only this case satisfies the spin echo condition perfectly. By increasing the pinhole size, an increasing number of neutron trajectories do not satisfy the spin echo condition, leading to a reduction in PNSE. This reduction is substantial, but not obstructive, as a pinhole with a radius of 5 mm (thus a/4) leads to PNSE ≃ 0.6, which, depending on the spin echo length of the measurement, would be sufficient for performing SESANS measurements.
For a more quantitative evaluation we calculated the figure of merit (FOM) of the setup, derived from the relative error of PNSE:
where the error ΔPNSE is determined from the derivative of PNSE and In is the total intensity of the detected neutron beam, proportional to the area of the pinhole, In ∝ p2. As shown in Fig. 8(b), if the FOM is plotted against the pinhole size, it goes through maxima which mark the optimal operating conditions with the best compromise between resolution and neutron beam intensity.
2.3. Effect of scattering: relation between precession and momentum transfer
In the case of scattering, the trajectories before and after the sample are no longer correlated with each other. Here we start by assuming an infinitesimally small pinhole at the sample position such that rS = 0. In this case there is a clear relation between the radii of the points where the neutron beam impinges on the shifters:
where in the absence of scattering r1 = r4 and r2 = r3. Using equation (27), the net precession angle defined in equation (24) becomes
Fig. 5 shows the trajectory of a possible scattering process and defines the crossing points at the shifters. The direct neutron beam travels from A′ at the first shifter to point A at the fourth shifter, with because of the pinhole. Scattered neutrons are deflected to point B.
The momentum transfer is defined as Q = ki − kf, where ki and kf are the wavevectors of the incident and scattered neutrons, respectively. Only is considered here and therefore |ki| = |kf| = k0 = 2π/λ. The vector ki points along the trajectory of the incident or direct beam, along the vector SA from the crossing point with the sample S to the point A (equal to the vector between A′ at the first shifter and S), while the direction of kf is given by the vector SB from S to B:
Using the coordinate notation from above for the crossing points A and B, and the condition for a pinhole (p = 0), the wavevectors can be written as
Consequently, the total momentum transfer vector becomes
where the square roots are approximated assuming rA, rB << L, such that (r2 + L2)1/2 ≃ L, and the modulus of the momentum transfer is given by
Both the equation for Q and Fig. 5 show that the momentum transfer takes place in the xy plane. This is the detector plane, and looking at the scattering process in this plane involves the projected wavevectors derived from equations (30) and (31):
The moduli of these vectors depend on the radial coordinates rA and rB:
The total momentum transfer Q is now decomposed into a radial Qr and a complementary QC component, as shown in Fig. 9. Qr points in a radial direction parallel to and its modulus is determined by the lengths of the wavevector projections given in equation (36). The difference between and labels the momentum transfer in the radial direction:
In contrast, the complementary component cannot be expressed clearly in terms of the wavevectors without knowing the polar coordinates αA and αB.
By combining the derived expressions for the precession angle Δφ [equation (28)] and Qr [equation (37)] while considering that rA = r1 and rB = r4, we find that the net precession angle is proportional only to the radial momentum transfer. This is an important result, indicating that only one component of the momentum transfer vector is included in the measured signal. Since there is no unique relationship between Qr and QC, it is not possible to calculate the magnitude or direction of Q from the vector equation Qr + QC = Q without knowledge of QC. In other words, radial SESANS probes only the momentum transfer along the radial direction without the possibility of obtaining the total momentum transfer,
This equation has been derived in the limit of an infinitely small sample pinhole. A satisfactorily high PNSE can be obtained for a sample pinhole with a diameter p = a/4. Therefore, equation (38) will be less strict for scattering events, especially those where the incoming and outgoing vectors are close to the optical axis. However, these events occur less frequently than those where they are closer to the edge of the diaphragms, since there is more area. This small deviation from equation (38) gives rise to a spread in precession for a certain Qr, leading to a resolution effect for the SESANS measurement as a function of spin echo length.
As in linear SESANS, the proportionality factor δ in equation (38) is the spin echo length,
which can be varied by changing the current I in the shifter coils while keeping all other parameters, including the precession magnetic field, unchanged.
The NSE polarization and FOM in Fig. 8 were calculated for different δ values that can be achieved with the described setup. For I varying between 2 and 10 A in shifter coils with a winding density of nW = 2 mm−1, ℓ1 = 1 m and a neutron wavelength of λ = 10 Å, δ ranges from 0.37 to 1.85 µm.
In general, the defined momentum transfer components Qr and QC are not perpendicular to each other. For scattering with a small total momentum transfer, however, this can be assumed since Qr is small and a linear approximation, as shown in Fig. 10, is justified. If so, holds for the measured component Qr and the complementary component QC. This situation resembles the momentum encoding in linear SESANS, where the total momentum transfer is always decomposed into perpendicular components. In other words, radial SESANS is similar to the conventional linear method, as it does not allow for accessing more than just a component of the momentum transfer vector.
A consequence of the fact that Δφ depends only on Qr is that radial SESANS probes only correlations along the radial direction. Similar to linear SESANS, this leads to a projected correlation function, defined as the Hankel transform of the sample's scattering function. For radially symmetric functions the Hankel transform can be derived from a two-dimensional Fourier transform (Bouwman et al., 2000; Andersson et al., 2008; Uca et al., 2003),
The integral is over all Q values reaching the detector. In the given case, the integral translates to an integral over the radii of the first and last shifter and over the difference in polar angles α (cf. Fig. 9). The normalized correlation function becomes
where a is the shifter radius determining the maximum detectable Q value and thus the minimum size measurable.
2.4. Scattering from spherical particles
In the following we evaluate the performance of the radial SESANS setup and compare it with linear SESANS. For this purpose we consider the simple case of isolated spherical particles of radius R, whose scattering function is given by (Guinier & Fournet, 1955)
The results for different particle radii are drawn in Fig. 11 for both radial and linear SESANS. For the latter, G(δ) has been calculated analytically (Krouglov, de Schepper et al., 2003) and thus corresponds to an ideal setup where instrument parameters, such as angular acceptance, are not taken into account.
Comparison of the two data sets shows that G(δ) of radial SESANS also goes to zero at the δ values corresponding to the maximal distance of the scattering particle, which in the case of spheres corresponds to their diameter. On the other hand, for small R, and therefore large values of Q, the radial SESANS results deviate from those of the analytical calculation. This is due to the angular acceptance of the setup and thus the shifter size, which determines the maximal detectable Q value in radial SESANS. The calculation of equation (41) was performed with a shifter radius of a = 20 mm, which gives a minimum measurable particle radius of less than R = 50 nm for the given setup (ℓ1 = ℓ2 = 1 m, λ = 10 Å). Below this radius the SESANS correlation function deviates from the analytical result, and this holds not only for radial but also for linear SESANS (Rekveldt, 1996).
3. Radial SEMSANS
The rotationally symmetric magnetic field geometry, consisting of radial shifters and longitudinal precession fields, can also be implemented for SEMSANS. In this technique, all spin manipulations take place in two precession regions before the sample (see Fig. 12).
Existing SEMSANS instruments are built with transverse precession fields that have inclined front and end faces, as for linear SESANS. In this case, the total Larmor precession angle accumulated by the neutrons depends linearly on the height of their trajectory at the detector but is independent of their divergence angle. When the focus condition B1ℓ1 = B2ℓ2 is satisfied (Bouwman et al., 2009, 2011), where B1 and B2 are the precession magnetic fields and ℓ1 and ℓ2 are the distances of the respective precession areas from the detector, this leads to a spatial modulation of the neutron beam intensity at the detector. Any scattering by a sample decreases the amplitude of that modulation, also called visibility (Bouwman et al., 2011; Li et al., 2016).
The SEMSANS normalized visibility is analogous to the normalized NSE polarization in SESANS, and therefore both methods probe the same projected correlation function (Bouwman et al., 2011; Strobl et al., 2015). The labelled direction in the precession angle φ, and thus the orientation of the modulation, are determined by the direction of the magnetic fields. While transverse fields create a modulation along the detector height (transverse direction), the modulation in radial SEMSANS would be along the radial coordinate, starting at the beam centre.
3.1. Precession angle and momentum transfer
Fig. 12 shows the setup of a radial SEMSANS instrument. Two shifters encode the radial coordinate of the neutron trajectory in φ. The magnetic fields and positions are set to B2 = 2B1 and ℓ1 = 2ℓ2 to satisfy the focus condition. As before, a neutron trajectory can be defined by its crossing points at the shifters Shi, the sample S and the detector D using cylindrical coordinates:
Using equation (10), the total precession angle Δφ, defined as the difference between the precession accumulated before and after the π flipper, becomes
in which K is defined as in equation (10) for the first shifter. In SEMSANS it is crucial to have a direct proportionality between Δφ and the radial position of a neutron at the detector rD. In the absence of scattering, the radial coordinate of the crossing point at the second shifter r2 can be first expressed as a function of r1 and rD. With ℓ1 = 2ℓ2 and α1D = α1 − αD this gives
As a second step we introduce a small pinhole in front of the first shifter, so that, and we can use the Taylor expansion,
This simplifies the expression for the total precession angle, which in the absence of scattering becomes
This indeed provides a linear relation between Δφ and rD, which shows that this setup creates a radial modulation. However, this result is not valid close to the detector centre (rD → 0) where our approximation using the Taylor expansion breaks down.
In the presence of scattering, we can express Δφ as a function of the radial momentum transfer Qr and a spin echo length in a way very similar to radial SESANS. For this derivation, we introduce an infinitesimally small pinhole in front of the first shifter so that r1 → 0. The radius r2 can then be derived from the geometry of the setup:
The precession angle from equation (47) becomes
Considering the wavevectors for the incident and scattered neutron beams, we derive the moduli of their projections onto the xy plane as
where αSD = αS − αD, and rS and rD are small compared with ℓ1 or ℓS.
The radial component of the momentum transfer vector thus becomes
Using equations (52) and equation (54) we obtain
where the factor in front of Qr denotes a spin echo length δ, with
The spin echo length depends on the distance between the shifters, which is as expected and is also the case for radial SESANS.
The variation in the visibility of the modulation in the beam intensity at the detector can be calculated in the most general case, beyond the small pinhole approximation. For a pinhole of radius R in front of the first shifter, so that 0 ≤ r1 ≤ R, we obtain
In the following, Δφ was determined using equations (47) and (48) in equation (57). The integration was performed numerically for different spin echo lengths between 0.1 and 1.8 µm. The results obtained in the absence of scattering, for a pinhole with R = 0.5 mm and as a function of rD, are illustrated in Fig. 13. This shows that it is also possible to perform SEMSANS measurements with radial shifters, even though the visibility is lower than for linear SEMSANS.
As in the previous section for SESANS, we consider here shifters with a winding density of nW = 2 mm−1. The generated magnetic field gradient is therefore not continuous, as assumed in the mathematical model, but a stepped function of the windings. This approach thus breaks down when the radius of the pinhole becomes comparable to or smaller than the radius of the innermost shifter coil loop. In this case the effect of the first shifter drops out, leading to another expression for the total precession angle: Δφ = −2Kr2. The effect on the modulation can be seen in the recalculated visibility shown in Fig. 13(a). This effect will further reduce the visibility for radial SEMSANS.
4. Concluding remarks
Since the early days of NSE it has been acknowledged that shifter coils combined with longitudinal precession fields, as found in NSE spectrometers, may be used to encode the neutron beam trajectories for SESANS-like applications (Pynn, 1978, 1980). In this article we have discussed how linear shifter coils can lead to a configuration that is conceptually equivalent to the SESANS setup, which has been developed in Delft (Rekveldt, 1996; Rekveldt et al., 2003; Andersson et al., 2008) and uses transverse (vertical) magnetic fields with inclined boundaries. This configuration is only sensitive to the projection of the momentum transfer vector along the (vertical) direction, which is defined by the inclination of the magnetic field boundaries.
Here we have considered radial, instead of linear, magnetic field integral gradients and have evaluated the performance of a SESANS setup resulting from the combination of radial shifter coils with longitudinal precession fields, in concordance with the cylindrical symmetry of the setup. Our results show that this configuration is also sensitive to the projection of the momentum transfer vector along one direction, in this case the radial one. Thus, in this case SESANS also yields a projected correlation function. We argue that this should be the case for all SESANS realizations, independent of their specific magnetic field geometry. In fact, as the magnetic field integral varies in a continuous fashion across the area of the neutron beam it is always possible to identify continuous `equipotential' lines along which the magnetic field (integral) gradient vanishes [e.g. along x in Fig. 4(a) or along all circles centred at y = 0 and z = 0 in Fig. 4(b)]. Consequently, the SESANS signal would be insensitive to the correlation function along these lines and would yield the projected correlation function along those direction(s) along which the magnetic field (integral) gradient is maximum: y in Fig. 4(a) or the radial direction in Fig. 4(b). This is an important difference between SESANS and NSE spectroscopy and explains why the former yields a projected correlation function, whereas the latter, which probes a scalar quantity (the at the sample), delivers the intermediate scattering function directly.
The performance of linear SESANS does not depend on neutron beam characteristics such as beam dimensions and divergence. In contrast, our results show that radial SESANS performs best for p << a, i.e. when the radius of the neutron beam at the sample is small in comparison with that at the outer shifter coils. This requirement ensures that the spin echo condition is satisfied for a majority of trajectories but also leads to substantial intensity losses. Nonetheless, the results of Fig. 8 show that for a realistic configuration, in the absence of scattering, it is possible to increase the beam size at the sample, e.g. p/a ≃ 1/4, while keeping a reasonable spin echo polarization. In addition, scattering from a model sample consisting of simple spherical particles provides results consistent with what would be expected for linear SESANS. The simple setup considered here should reach spin echo lengths ranging from about 100 nm to a few micrometres. Higher resolutions could be obtained by using stacked shifter coils, as is commonly the case with Fresnel coils in NSE spectrometers.
Longitudinal magnetic fields combined with radial shifter coils could also be used for radial SEMSANS, although with a substantially reduced performance with respect to its linear SEMSANS counterpart. Radial SEMSANS requires the smallest possible beam aperture at the point (first shifter) where the Larmor labelling begins. This of course dramatically reduces the intensity of the neutron beam and at the same time makes the first shifter redundant when the dimensions of the aperture become comparable to the distance between the wires of this shifter coil.
To conclude, linear and radial SE(M)SANS are conceptually similar to each other but the linear realization clearly outperforms the radial one. In addition, both setups can be realized by combining shifter coils (radial or linear) with longitudinal magnetic fields, as found at NSE spectrometers, and could be implemented as add-ons to existing instruments. The spin echo length that can be reached would be similar to those obtainable on present SESANS instruments (some 10–20 µm). The advantage of such a realization would lie in the combination of the long wavelengths accessible to existing NSE instruments and their high neutron
In this way it would be possible to study weakly scattering systems and perform kinetic measurements on the timescale of minutes instead of hours, which is presently the limit.Compared with existing SESANS instruments, such a realization would allow for using custom-made in-beam coils, with current densities adapted to specific requirements that could enable new types of experiments with unexplored capabilities.
Acknowledgements
The authors thank Dr Niels van Dijk for valuable discussions about the manuscript.
References
Andersson, R., van Heijkamp, L. F., de Schepper, I. M. & Bouwman, W. G. (2008). J. Appl. Cryst. 41, 868–885. Web of Science CrossRef CAS IUCr Journals Google Scholar
Bouwman, W. G. (2021). Food. Struct. 30, 100235. Web of Science CrossRef Google Scholar
Bouwman, W. G., Duif, C. P. & Gähler, R. (2009). Physica B, 404, 2585–2589. Web of Science CrossRef CAS Google Scholar
Bouwman, W. G., Duif, C. P., Plomp, J., Wiedenmann, A. & Gähler, R. (2011). Physica B, 406, 2357–2360. Web of Science CrossRef CAS Google Scholar
Bouwman, W. G., van Oossanen, M., Uca, O., Kraan, W. H. & Rekveldt, M. T. (2000). J. Appl. Cryst. 33, 767–770. Web of Science CrossRef CAS IUCr Journals Google Scholar
Bouwman, W. G., Plomp, J., de Haan, V. O., Kraan, W. H., van Well, A. A., Habicht, K., Keller, T. & Rekveldt, M. T. (2008). Nucl. Instrum. Methods Phys. Res. A, 586, 9–14. Web of Science CrossRef CAS Google Scholar
Gähler, R., Felber, J., Mezei, F. & Golub, R. (1998). Phys. Rev. A, 58, 280–295. Web of Science CrossRef CAS Google Scholar
Gähler, R., Golub, R., Habicht, K., Keller, T. & Felber, J. (1996). Physica B, 229, 1–17. CrossRef Web of Science Google Scholar
Gruijthuijsen, K. van, Bouwman, W. G., Schurtenberger, P. & Stradner, A. (2014). Europhys. Lett. 106, 28002. Google Scholar
Gruijthuijsen, K. van, Obiols-Rabasa, M., Schurtenberger, P., Bouwman, W. & Stradner, A. (2018). Soft Matter, 14, 3704–3715. Web of Science PubMed Google Scholar
Guinier, A. & Fournet, G. (1955). Small-Angle Scattering of X-rays. New York: Wiley. Google Scholar
Kohlbrecher, J. & Studer, A. (2017). J. Appl. Cryst. 50, 1395–1403. Web of Science CrossRef CAS IUCr Journals Google Scholar
Krouglov, T., Bouwman, W. G., Plomp, J., Rekveldt, M. T., Vroege, G. J., Petukhov, A. V. & Thies-Weesie, D. M. E. (2003). J. Appl. Cryst. 36, 1417–1423. Web of Science CrossRef CAS IUCr Journals Google Scholar
Kruglov, T. V., Bouwman, W. G., de Schepper, I. M. & Rekveldt, T. M. (2005). Physica B, 356, 218–222. Web of Science CrossRef CAS Google Scholar
Krouglov, T., de Schepper, I. M., Bouwman, W. G. & Rekveldt, M. T. (2003). J. Appl. Cryst. 36, 117–124. Web of Science CrossRef CAS IUCr Journals Google Scholar
Li, F., Parnell, S. R., Bai, H., Yang, W., Hamilton, W. A., Maranville, B. B., Ashkar, R., Baxter, D. V., Cremer, J. T. & Pynn, R. (2016). J. Appl. Cryst. 49, 55–63. Web of Science CrossRef CAS IUCr Journals Google Scholar
Li, F., Steinke, N.-J., Dalgliesh, R. M., Washington, A. L., Shen, J., Pynn, R. & Parnell, S. R. (2021). Nucl. Instrum. Methods Phys. Res. A, 1014, 165705. Web of Science CrossRef Google Scholar
Li, X., Shew, C.-Y., Liu, Y., Pynn, R., Liu, E., Herwig, K. W., Smith, G. S., Robertson, J. L. & Chen, W.-R. (2011). J. Chem. Phys. 134, 094504. Web of Science CrossRef PubMed Google Scholar
Mezei, F. (1972). Z. Phys. 255, 146–160. CrossRef CAS Web of Science Google Scholar
Mezei, F. (1980a). Neutron Spin Echo, Lecture Notes in Physics, Vol. 128, pp. 178–192. Berlin: Springer Verlag. Google Scholar
Mezei, F. (1980b). Neutron Spin Echo, Lecture Notes in Physics, Vol. 128, pp. 113–121. Berlin: Springer Verlag. Google Scholar
Mezei, F. (1980c). Neutron Spin Echo, Lecture Notes in Physics, Vol. 128, pp. 4–26. Berlin: Springer Verlag. Google Scholar
Mezei, F., Pappas, C. & Guthberlet, T. (2003). Editors. Neutron Spin Echo Spectroscopy, Lecture Notes in Physics, Vol. 601. Berlin: Springer Verlag. Google Scholar
Monkenbusch, M. (1990). Nucl. Instrum. Methods Phys. Res. A, 287, 465–475. CrossRef Web of Science Google Scholar
Pynn, R. (1978). J. Phys. E Sci. Instrum. 11, 1133–1140. CrossRef CAS Web of Science Google Scholar
Pynn, R. (1980). Neutron Spin Echo, Lecture Notes in Physics, Vol. 128, pp. 159–177. Berlin: Springer Verlag. Google Scholar
Rekveldt, M. T. (1996). Nucl. Instrum. Methods Phys. Res. B, 114, 366–370. CrossRef CAS Web of Science Google Scholar
Rekveldt, M. T., Bouwman, W., Kraan, W., Uca, O., Grigoriev, S., Habicht, K. & Keller, T. (2003). Neutron Spin Echo Spectroscopy, Lecture Notes in Physics, Vol. 601, pp. 87–99. Berlin: Springer Verlag. Google Scholar
Rekveldt, M. T., Plomp, J., Bouwman, W. G., Kraan, W. H., Grigoriev, S. & Blaauw, M. (2005). Rev. Sci. Instrum. 76, 033901. Web of Science CrossRef Google Scholar
Sales, M., Plomp, J., Habicht, K. & Strobl, M. (2015). J. Appl. Cryst. 48, 92–96. Web of Science CrossRef CAS IUCr Journals Google Scholar
Schleger, P., Ehlers, G., Kollmar, A., Alefeld, B., Barthelemy, J., Casalta, H., Farago, B., Giraud, P., Hayes, C., Lartigue, C., Mezei, F. & Richter, D. (1999). Physica B, 266, 49–55. Web of Science CrossRef CAS Google Scholar
Schmitt, J., Zeeuw, J. J., Plomp, J., Bouwman, W. G., Washington, A. L., Dalgliesh, R. M., Duif, C. P., Thijs, M. A., Li, F., Pynn, R., Parnell, S. R. & Edler, K. J. (2020). Appl. Mater. Interfaces, 12, 28461–28473. Web of Science CrossRef CAS Google Scholar
Strobl, M., Sales, M., Plomp, J., Bouwman, W. G., Tremsin, A. S., Kaestner, A., Pappas, C. & Habicht, K. (2015). Sci. Rep. 5, 16576. Web of Science CrossRef PubMed Google Scholar
Uca, O., Bouwman, W. G. & Rekveldt, M. T. (2003). J. Appl. Cryst. 36, 109–116. Web of Science CrossRef CAS IUCr Journals Google Scholar
Washington, A., Li, X., Schofield, A. B., Hong, K., Fitzsimmons, M., Dalgliesh, R. & Pynn, R. (2014). Soft Matter, 10, 3016–3026. Web of Science CrossRef CAS PubMed Google Scholar
Zhao, J. (2001). J. Appl. Cryst. 34, 639–645. Web of Science CrossRef CAS IUCr Journals Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.