MSP method in TOPAS GUI Mode: (a) assign the sum of I from hkl_Is fitting to the parameter S_Kao; calculate the M_Kao S_Kao / mol_f2_Kao / Get(cell_volume) value from the molecule weight M_Kao and the pre-calculated molecular scattering power mol_f2_Kao; (b) input the above-calculated value of M_Kao S_Kao / mol_f2_Kao / Get(cell_volume) into the `Cell Mass' box for this hkl_Is phase. Run the refinement again to obtain QPA results for all phases in this mixture.