short communications\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Performance of the YB66 soft X-ray monochromator crystal at the wiggler beamline of the UVSOR facility

aInstitute for Molecular Science, Okazaki 444-8585, Japan, bDepartment of Physics, Naruto University of Education, Naruto 772-8502, Japan, cDepartment of Molecular Engineering, Kyoto University, Kyoto 606-8501, Japan, dThe Institute of Scientific and Industrial Research, Osaka University, Ibaraki, Osaka 567-0047, Japan, eDepartment of Applied Chemistry, School of Engineering, Nagoya University, Nagoya 464-8603, Japan, fDivision of Energy Science, Center for Integrated Research in Science and Engineering, Nagoya University, Nagoya 464-8602, Japan, gDepartment of Structural Molecular Science, Graduate University for Advanced Studies, Okazaki 444-8585, Japan, and hInstitute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), Oho 1-1, Tsukuba 305-0801, Japan
*Correspondence e-mail: toyohiko@ims.ac.jp

(Received 4 August 1997; accepted 18 November 1997)

Soft X-ray spectra have been measured using a pair of YB66(400) monochromator crystals at the double-crystal monochromator beamline BL7A of the UVSOR facility, where the wiggler radiation has a magnetic field of 4 T. Deformation of the YB66 crystal due to heat load from the synchrotron radiation is almost negligible. The photon flux is about 108 photons s−1 (100 mA)−1 in the energy region 1.2–2 keV and the energy resolution is 0.7 ± 0.1 eV around hν = 1.5 keV. These results show that the YB66 crystal is suitable for use as a monochromator crystal. Its application to soft X-ray spectroscopy is discussed.

1. Introduction

YB66 [2d = 11.76 Å for (400) reflection] is known to be one of the best monochromator crystals covering the soft X-ray region from 1.1 to 2 keV, with high performance (Wong et al., 1990[Wong, J., Shimkaveg, G., Goldstein, W., Eckart, M., Tanaka, T., Rek, Z. U. & Tompkins, H. (1990). Nucl. Instrum. Methods A, 291, 243-249.]) such as high-energy resolution, no absorption structures originating from the elements of the crystal in the photon energy range, resistance to radiation damage etc. So far, only the SSRL (Stanford Synchrotron Radiation Laboratory) group has used a YB66 crystal (Rowen et al., 1993[Rowen, M., Rek, Z. U., Wong, J., Tanaka, T., George, G. N., Pickering, I. J., Via, G. H. & Brown, G. E. Jr (1993). Synchrotron Radiat. News, 6, 25-27.]), since there are several difficulties associated with the use of YB66 crystals in synchrotron radiation facilities. One of the difficulties is that a single crystal of sufficient size has not, until very recently, been available. The other difficulty is that such a crystal has a very low thermal conductivity and is easily deformed by the high heat load from synchrotron radiation from a high-energy machine. Even in the SSRL facility, there seems to be some difficulty in using the crystal for spectroscopy experiments because of the heat load.

The storage ring of the UVSOR facility is operated at a rather low energy (750 MeV) and is expected to produce a lower heat load than a high-energy machine. For example, at the double-crystal monochromator beamline BL11B of the Photon Factory (2.5 GeV), the power density was estimated as 3.3 W mm−2 on the first crystal (Funabashi et al., 1989[Funabashi, M., Nomura, M., Kitajima, Y., Yokoyama, T., Ohta, T. & Kuroda, H. (1989). Rev. Sci. Instrum. 60, 1983-1986.]). However, the density in the present case is less than 0.03 W mm−2. A wavelength-shifter-type wiggler with a 4 T magnetic field (Nakamura et al., 1996[Nakamura, E., Hama, H., Yamazaki, J., Kinoshita, T., Matsudo, O., Yonehara, H., Kasuga, T., Isoyama, G. & Watanabe, M. (1996). J. Electron Spectrosc. Relat. Phenom. 80, 421-424.]) is installed at the UVSOR beamline BL7A (Murata et al., 1992[Murata, T., Matsukawa, T., Naoé, S., Horigome, T., Matsudo, O. & Watanabe, M. (1992). Rev. Sci. Instrum. 63, 1309-1312.]) to provide a high photon flux in the soft X-ray region. This prompted us to examine the performance of a YB66 monochromator crystal at the UVSOR facility. The crystal (10 × 20 × 1 mm size) is a commercial product, synthesized by Crystal Systems Inc., Yamanashi, Japan.

2. Overview of the wiggler beamline at UVSOR

Fig. 1[link] shows a schematic view of the double-crystal monochromator (DXM) beamline BL7A. The superconducting magnet wiggler is installed in the straight section upstream of the bending-magnet section B7. When the higher-energy light from the wiggler is used with crystals such as InSb(111) and Ge(111), the beamline is fixed just downstream of the straight section (0° line). In the case of synchrotron radiation from the bending section, the DXM accepts synchrotron radiation emitted at a point on the electron orbit that is 2° downstream of the edge of the bending section. In order to avoid radiation damage to the insulator crystals of, e.g. beryl and quartz (energy being covered 0.8–2 keV), we use bending-magnet radiation. Between the use of wiggler radiation and bending-magnet radiation, the beamline set-up is changed from the 0° line to the 2° line. YB66 is a semiconductor and may be better at withstanding radiation damage than insulator crystals. If we succeed in using a YB66 crystal in the lower photon energy region, it will not be necessary to change the beamline between the wiggler and bending lines. This will enable us to provide high-performance beamtime to users.

[Figure 1]
Figure 1
A schematic view of the soft X-ray beamline BL7A at UVSOR.

3. Performance of the YB66 monochromator crystal

Fig. 2[link] shows the throughput of the monochromator with the use of YB66(400). The absolute value of the photon flux was obtained by measuring the photocurrent from a Si photodiode (International Radiation Detectors Inc., USA) whose quantum efficiency has been calibrated absolutely. When radiation from the wiggler is used, the photon flux is approximately 108 photons s−1 (100 mA)−1. The decrease in the flux at lower photon energy is due to the cut-off of the Be foil. A flux of 104–107 photons s−1 (100 mA)−1 is obtained with bending-magnet radiation.

[Figure 2]
Figure 2
The throughput of the double-crystal monochromator with YB66(400). Radiation from the wiggler and the bending-magnet section is used.

The X-ray absorption fine-structure (XAFS) spectra for Mg and Al oxides in Fig. 3[link] were measured by the total photoelectron yield method as described previously (Murata et al., 1992[Murata, T., Matsukawa, T., Naoé, S., Horigome, T., Matsudo, O. & Watanabe, M. (1992). Rev. Sci. Instrum. 63, 1309-1312.]). The step width of the monochromator scanning was 0.01°, which corresponds to about 0.15 eV at hν = 1310 eV. The reproducibility of energies was within the step width. The spectra obtained using the YB66 crystal show almost the same features as those obtained using beryl and quartz crystals. During the spectroscopy measurements, we also checked the effects of the heat load. We monitored the beam intensity at the sample position and tuned the angle of the second monochromator crystal to maximize the intensity. The angle deviation originating from the change of the lattice spacing in the first crystal was estimated by measuring the deviation of the tuning angle of the second crystal. The angle correction due to the heat-load effects was estimated to be less than 0.01°, which corresponds to energy shifts of less than 0.15 eV around hν = 1.3 keV. The value of the energy shift is much less than that in the SSRL, where an approximately 3 eV shift is reported (Wong, private communication). It is concluded from the above result that the effect of heat load at BL7A is almost negligible for spectroscopy measurements.

[Figure 3]
Figure 3
(a) Comparative X-ray absorption spectra of MgO around the Mg K-edge taken by YB66 and beryl crystals. (b) Comparative X-ray absorption spectra of Al2O3 around the Al K-edge taken by YB66 and quartz crystals.

We have tried to measure the rocking curves of the YB66 crystal by rotating the second crystal in order to estimate energy resolution (not shown here). The rocking curves showed some multi-structures and were wider than those reported before (Rowen et al., 1993[Rowen, M., Rek, Z. U., Wong, J., Tanaka, T., George, G. N., Pickering, I. J., Via, G. H. & Brown, G. E. Jr (1993). Synchrotron Radiat. News, 6, 25-27.]). This may result from the multi-domain structures of the crystal, as will be discussed below. If we assume the multi-structures are a convolution of single peaks, the width of each single peak is estimated to be about 0.7 ± 0.1 eV around hν = 1.5 keV. This value is equal to the deconvoluted value of the photoemission resolution discussed in §[link]4 and almost comparable with that in the SSRL beamline under standard conditions. We have also observed the image of output light with the fluorescence screen. The image was not homogeneous. These results mean that the crystal is not an ideal single crystal, but instead consists of multi-domains. The effect of the multi-domains is not a serious problem. For example, we have obtained reasonable spectra [except for the problem of the (600) reflection as described below] with higher-energy resolution than that of a beryl crystal, as shown in Fig. 3[link]. If we could obtain a crystal with a single domain, the intensity and resolution may be improved.

These results show that the YB66 crystal is suitable for use as a monochromator crystal. However, there remains another problem which needs to be solved in order to use the YB66 crystal for spectroscopy. The problem is that two positive glitches at 1385.6 and 1438 eV are observed in Figs. 2[link] and 3[link](a). These glitches are known to be due to the sharp reflectivity increase associated with anomalous scattering of the (600) reflection at the Y L2,3-edges (Tanaka et al., 1997[Tanaka, T., Aizawa, T., Rowen, M., Rek, Z. U., Kitajima, Y., Higashi, I., Wong, J. & Ishizawa, Y. (1997). J. Appl. Cryst. 30, 87-91.]). The original [(400) reflection light] peaks are also observed in Fig. 2[link] at 2080 and 2156 eV, respectively. In order to record more precise extended XAFS spectra, the high-energy component of the light must be reduced for the next step of the beamline improvement. We plan to install a pair of pre-focusing mirrors coated by Si between the Be window and the front end. The Si-coated mirror system is expected to be useful not only as a focusing system but also as a high-cut filter.

4. Application to spectroscopy

We have applied the light monochromated with the YB66 crystal not only to measurements of absorption spectroscopy but also to photoemission measurements. We present here, as an example, the resonant photoemission study of heavy rare-earth compounds (Kinoshita et al., 1998[Kinoshita, T., Ufkutepe, Y., Kimura, S., Nath, K. G., Kumigashira, H., Takahashi, T., Matumura, T., Suzuki, T., Ogasawara, H. & Kotani, A. (1998). J. Electron Spectrosc. Relat. Phenom. In the press.]). Although the photon intensity is not great enough, the photoemission study becomes possible by using a high-performance electron analyser (Fisons, ESCALAB220i-XL).

Fig. 4[link] shows the 3d–4f resonant photoemission result for TmSe, which is typically known to be a material of mixed valency. Despite the advantages of studying 3d–4f resonant photoemission for heavy rare-earth compounds, in addition to 4d–4f resonance, only a few investigations have so far been performed. The reason why such experiments are difficult is that grating monochromators cannot cover such high-energy light with high-energy resolution and high intensity. As shown in Fig. 4[link], the spectra have been obtained with a resolution of 0.9 ± 0.1 eV and a reasonable S/N ratio in the photon energy region 1.45–1.52 keV. The resolution of the data seems to be better than that obtained for a TmAl2 sample with a beryl monochromator crystal (Laubschat et al., 1990[Laubschat, C., Weschke, E., Kalkowski, G. & Kaindl, G. (1990). Phys. Scr. 41, 124-129.]), especially in off-resonant conditions. It is clearly observed that the divalent peaks (located at a binding energy less than 5.6 eV) and the trivalent peaks (located at a binding energy greater than 5.6 eV) show resonance at different excitation energies.

[Figure 4]
Figure 4
The photoemission spectra of TmSe at an excitation photon energy of the 3d–4f resonance region. The photoemission spectra were measured at the photon energies of the points indicated by arrows in the absorption (total photoelectron yield; TY) spectrum (bottom).

5. Conclusions

We have succeeded in measuring soft X-ray spectra using the YB66 monochromator crystal at the DXM beamline BL7A of the UVSOR facility. The combination of the YB66 crystal and the wiggler at such a low-energy storage ring performs well in soft X-ray measurements. The YB66 crystal may be very valuable for use in future studies of soft X-ray spectroscopy at UVSOR. The YB66 crystal has already been used by some users. Photoabsorption and photoelectron spectroscopy experiments in such a photon energy region are now possible.

Footnotes

Present address: Department of Chemistry and Material Technology, Faculty of Engineering and Design, Kyoto Institute of Technology, Kyoto 606-8585, Japan.

§Visiting scientist on leave from Physics Department, University of Cukurova, 01330 Adana, Turkey.

Acknowledgements

The authors would like to thank the staff of the UVSOR facility for their support. TK and YT thank Dr T. Tanaka and Dr J. Wong for invaluable discussions.

References

First citationFunabashi, M., Nomura, M., Kitajima, Y., Yokoyama, T., Ohta, T. & Kuroda, H. (1989). Rev. Sci. Instrum. 60, 1983–1986.  CrossRef CAS Web of Science
First citationKinoshita, T., Ufkutepe, Y., Kimura, S., Nath, K. G., Kumigashira, H., Takahashi, T., Matumura, T., Suzuki, T., Ogasawara, H. & Kotani, A. (1998). J. Electron Spectrosc. Relat. Phenom. In the press.
First citationLaubschat, C., Weschke, E., Kalkowski, G. & Kaindl, G. (1990). Phys. Scr. 41, 124–129.  CrossRef CAS Web of Science
First citationMurata, T., Matsukawa, T., Naoé, S., Horigome, T., Matsudo, O. & Watanabe, M. (1992). Rev. Sci. Instrum. 63, 1309–1312.  CrossRef CAS Web of Science
First citationNakamura, E., Hama, H., Yamazaki, J., Kinoshita, T., Matsudo, O., Yonehara, H., Kasuga, T., Isoyama, G. & Watanabe, M. (1996). J. Electron Spectrosc. Relat. Phenom. 80, 421–424.  CrossRef CAS Web of Science
First citationRowen, M., Rek, Z. U., Wong, J., Tanaka, T., George, G. N., Pickering, I. J., Via, G. H. & Brown, G. E. Jr (1993). Synchrotron Radiat. News, 6, 25–27.
First citationTanaka, T., Aizawa, T., Rowen, M., Rek, Z. U., Kitajima, Y., Higashi, I., Wong, J. & Ishizawa, Y. (1997). J. Appl. Cryst. 30, 87–91. CrossRef CAS Web of Science IUCr Journals
First citationWong, J., Shimkaveg, G., Goldstein, W., Eckart, M., Tanaka, T., Rek, Z. U. & Tompkins, H. (1990). Nucl. Instrum. Methods A, 291, 243–249.  CrossRef Web of Science

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds