research papers
On-line optical and X-ray spectroscopies with crystallography: an integrated approach for determining metalloprotein structures in functionally well defined states
aMolecular Biophysics Group, STFC Daresbury Laboratory, Warrington WA4 4AD, UK, and bSchool of Biological Sciences, University of Liverpool, Liverpool L69 7ZB, UK
*Correspondence e-mail: s.s.hasnain@liv.ac.uk
X-ray-induced redox changes can lead to incorrect assignments of the functional states of metals in metalloprotein crystals. The need for on-line monitoring of the status of metal ions (and other chromophores) during protein crystallography experiments is of growing importance with the use of intense synchrotron X-ray beams. Significant efforts are therefore being made worldwide to combine different spectroscopies in parallel with X-ray crystallographic data collection. Here the implementation and utilization of optical and X-ray absorption spectroscopies on the modern macromolecular crystallography (MX) beamline 10, at the SRS, Daresbury Laboratory, is described. This beamline is equipped with a dedicated monolithic energy-dispersive in situ on the same crystal used to record the diffraction data. In addition, an optical microspectrophotometer has been incorporated on the beamline, thus facilitating combined MX, and optical spectroscopic measurements. By uniting these techniques it is also possible to monitor the status of optically active and optically silent metal centres present in a crystal at the same time. This unique capability has been applied to observe the results of crystallographic data collection on crystals of nitrite reductase from Alcaligenes xylosoxidans, which contains both type-1 and type-2 Cu centres. It is found that the type-1 Cu centre photoreduces quickly, resulting in the loss of the 595 nm peak in the optical spectrum, while the type-2 Cu centre remains in the oxidized state over a much longer time period, for which independent confirmation is provided by data as this centre has an optical spectrum which is barely detectable using microspectrophotometry. This example clearly demonstrates the importance of using two on-line methods, spectroscopy and for identifying well defined redox states of metalloproteins during crystallographic data collection.
detector, allowing measurements to be madeKeywords: combined X-ray methods; XAS; optical spectroscopy; crystallography; microspectrophotometer; radiation damage; metalloproteins.
1. Introduction
The foremost part of our knowledge of protein structure and function is based on X-ray crystallography using synchrotron radiation. Metalloproteins comprise more than 30% of the proteins in a genome, and many of these use the redox properties of metals to catalyse enzymatic reactions. A particular issue in the study of metalloproteins by X-ray crystallography is whether the
is a true representation of the protein in a functionally relevant metal redox state.In this context, X-ray-induced via the photoelectric effect (Burmeister, 2000; Murray et al., 2005). The photoexcited electrons produced in this way can readily reduce redox centres in metalloproteins and measures have to be taken that either minimize or monitor these X-ray-induced effects.
of metal centres in proteins is a phenomenon which is of increasing concern to experimentalists using the highly intense X-ray beams produced by third-generation synchrotron radiation sources. The majority of the incident X-ray energy absorbed by a protein crystal isAs an example, consider the case of photosystem II, where et al., 2005). Similarly, rapid of three different haem proteins with varying has been shown using single-crystal (Beitlich et al., 2007). Importantly, in many cases it is non-trivial to identify changes in metal oxidation states using structural changes visible by X-ray crystallography alone, even at high resolution. We note that such photon-induced changes in (and hence in X-ray position) may also cause problems during phasing experiments.
data showed that the expected Mn(IV) cluster had become 80% photoreduced to biologically inactive Mn(II) by X-rays at less than the absorbed dose used for determining the (YanoWhere the protein contains a chromophore, spectroscopic measurements can be made on individual crystals (Hadfield & Hajdu, 1993; Mozzarelli & Rossi, 1996) and, as a response to these issues, increasing attention has been given to combining X-ray diffraction with single-crystal spectroscopies (Royant et al., 2007; Carpentier et al., 2007). For optically active metalloproteins, single-crystal microspectrophotometry may be used to monitor the metal centres and a key advance has been the incorporation of microspectrophotometers onto X-ray beamlines (on-line single-crystal spectroscopy) (Chen et al., 1994; Hadfield & Hajdu, 1993; Sakai et al., 2002). Through this approach, diffraction and optical spectroscopic data may be collected on the same crystal without the need to remove the sample from the beamline. To this end, macromolecular crystallography (MX) beamlines at a number of synchrotron sources, including the Swiss Light Source and ESRF, have been equipped with microspectrophotometers. These instruments have been used to monitor the redox state of intermediates generated during X-ray exposure of a methylamine dehydrogenase–amicyanin complex, thus allowing tailored data-collection protocols to be developed such that the structures of each intermediate could be determined (Pearson et al., 2007). In some cases, X-ray-driven reduction of metal centres may allow intermediate states in an enzymatic mechanism to be accessed (Schlichting et al., 2000).
Although optical microspectrophotometry is a powerful technique, it suffers from a major limitation in that many metal centres are optically silent in biologically relevant oxidation states (Table 1a). These include the important Cu(I) and Zn(II) states which are optically [and EPR (electron paramagnetic resonance)] silent owing to their d10 nature. Other metal sites, such as type-2 Cu centres, may contain an optically but the resulting spectrum may be too weak and difficult to measure in a crystal, as is the case for copper nitrite reductase, an enzyme under study in this paper. Also, in proteins that contain several different optically centres, it may not be possible to monitor the site with the weaker absorbance. An example would be sulfite oxidase where the optical spectrum of the molybdenum cofactor is entirely masked by that of the haem centre (Kisker, 2001).
b). The complementarity of protein crystallography (PX) with solution studies was noted (Hasnain & Hodgson, 1999; Hasnain & Strange, 2003) and capabilities to combine these methods on the same crystal were implemented on the MX beamline 10 at the SRS (Cianci et al., 2005; Arcovito et al., 2007) and at SSRL (Latimer et al., 2005; Yano et al., 2006). SRS beamline 10 is fully tunable over a wavelength range of 0.873 Å to 2.3 Å (5.45–14.21 keV) with a normal operating range of 0.92 Å to 2.07 Å (5.99–13.47 keV) delivering a of ∼1011 photons s−1. This energy range covers X-ray absorption edges for many of the biologically important 3d transition metals (Table 1b). Recently, we have exploited this beamline to combine X-ray diffraction and polarized XANES measurements on crystals of cyano-myoglobin (Arcovito et al., 2007).
in contrast, is generally applicable to metal centres in any (Table 1The end-station of the beamline is composed of a MAR desktop beamline (DTB) with cryogenic sample changer, with a MARMosaic 225 CCD detector for recording diffraction data and an Ortec C-TRAIN-04 detector for measuring et al., 1999). Here we describe an extension to these capabilities through the incorporation of a single-crystal microspectrophotometer into the goniometry, thus allowing optical spectra to be collected in situ and in parallel with X-ray diffraction and high-quality data. The combination of two spectroscopies allows the status of both optically active and optically silent metal centres to be monitored during a crystallographic experiment (see Hough et al., 2008).
data (Derbyshire2. Description of the experimental apparatus
A microspectrophotometer based on the 4DX Uppsala system (Hadfield & Hajdu, 1993; Wilmot et al., 2002) has been installed on SRS MAD beamline 10. Two light sources, halogen or halogen/deuterium, may be used to provide good spectral intensities in the UV–visible region (350–800 nm). A 50 µm fibre-optic cable transmits the light to a collimating lens/reflecting objective. The focal point of the light emitted by the objective is centred on the crystal some 24 mm away with a typical spot size of ∼25 µm. A second collimating lens/reflecting objective at the same distance from the sample passes the transmitted light via a 400 µm fibre-optic cable and through a 50 µm slit to an Oriel MS125 spectrograph equipped with a 400 lines mm−1 diffraction grating. The dispersed spectrum is then measured using an Andor DV401A-UV CCD detector (1024 × 127 pixels) operating at 213 K.
To incorporate the microspectrophotometer into the DTB, an easily attachable/removable mounting arc was designed that extends over the χ axis. In this configuration, one objective is behind and above the crystal and the second is below and in front of the crystal (Fig. 1). The arc is designed to be easily removable from the DTB to allow for a rapid transition between operation of the beamline with and without the instrument. Two guide pins and two screws locate and fix the arc into the DTB. A modified alignment tool has been designed specifically for the beamline, and the microspectrophotometer can be fitted and aligned ready for use in approximately 30 min. The positioning of the instrument is such that it does not interfere with the operation of the nitrogen cryostream and so data using all three techniques (optical spectroscopy, MX) may be collected at either room temperature or temperatures down to 100 K. This configuration allows the optical light path to be centred using the crystal microscope such that it intersects the same volume of the crystal as the X-ray beam, and allows both diffraction and data to be measured without removing the crystal from the system. This in turn allows both the optical spectroscopic and monitoring of the oxidation states of metal centres during crystallographic data collection.
Alignment of the objectives to the centred-sample position is conducted using an in-house alignment tool mounted on a Hampton pin adapter. This allows manual fine alignment of the light spot from the source to the cross hairs of the crystal-alignment camera. The Andor CCD detector may be calibrated to wavelength using a Holmium filter built into the light source. A series of test data were measured to ensure that the addition of the new instrument into the beamline goniometry did not significantly interfere with the normal measurement of crystallographic or
data. The correct operation of the fluorescence detector with the microspectrophotometer was confirmed by collection of data from metal foils, while test X-ray diffraction data were collected to a resolution limit of ∼1.5 Å.3. Experimental methods and results
3.1. Copper nitrite reductase from Alcaligenes xylosoxidans
In order to test the capabilities of this currently unique experimental facility, we have undertaken a combined optical–XAS-crystallographic study of crystals of copper nitrite reductase from Alcaligenes xylosoxidans (AxNiR). AxNiR contains both an optically active type-1 Cu (T1Cu) centre and a type-2 Cu (T2Cu) centre that has weak absorbance (Abraham et al., 1993)1 and is thus essentially optically silent with the current detection capabilities of the microspectrophotometer. The two copper centres are linked via a Cys–His bridge where T1Cu ligates to Cys and T2Cu ligates to His. Both Cu centres are in the Cu(II) in the resting enzyme. Under physiological conditions the T1Cu receives an electron from a partner protein, azurin. It has been shown that from T1Cu to T2Cu is gated and is triggered by the conformational changes resulting from the binding of nitrite to T2Cu, replacing the water molecule ligated to T2Cu in the resting state (Strange et al., 1999; Hough et al., 2005).
X-ray irradiation can be used to introduce electrons into the protein crystal that may be selectively taken up by metal centres, resulting in their reduction. By combining the three techniques described above, both metal centres may be monitored and the effect of X-ray exposure on redox state can be characterized. Recombinant native AxNiR was produced as described previously (Prudencio et al., 1999). Crystals in R3 were grown by the hanging-drop vapour-diffusion method. A drop containing 2 µl of 10 mg ml−1 protein solution was mixed with an equal volume of reservoir solution containing 20% PEG550 MME, 10 mM ZnSO4 and 100 mM MES pH 6.0. Crystals grew in one week and were intense blue in colour.
3.2. Optical, and MX data collection from AxNiR crystals
Crystals were transferred into a cryoprotectant solution consisting of mother liquor with a PEG550 MME concentration of 35% before mounting in a nitrogen cryostream at 100 K. Optical spectra were either an accumulation of 20 exposures each of 0.05 s duration or were single 0.5 s exposures measured at regular time intervals. Data were analysed using the Andor iDus software package. Background and reference spectra were measured with the crystal translated out of the light path. A crystal orientation was chosen such that the crystal spectrum matched the solution spectrum of AxNiR.
A crystal of AxNiR was exposed to a continuous of X-rays of wavelength 1.37 Å. The effect of this X-ray radiation exposure on the optical spectrum is shown in Fig. 2(a).2 The size (in absorbance units) of the 595 nm peak as a function of absorbed X-ray dose is given in Fig. 2(b). X-ray doses were calculated using the program RADDOSE (Murray et al., 2005) and included the absorption contributions from sulfur and metal atoms. In brief, photon fluxes were calculated from photodiode measurements carried out at the sample position. These photodiode measurements were referenced against the readings inside the collimator system of the MAR DTB allowing calculation of the incident on the sample position. Crystal sizes were measured using a graticule on one of the objectives on the microscope. These optical spectroscopic data indicate that the T1Cu centre was rapidly photoreduced from the Cu(II) to Cu(I) by X-ray exposure. We note that the X-ray dose sufficient to predominantly reduce the T1Cu centres is modest in comparison with doses commonly used in the determination of high-resolution crystal structures.
Cu K-edge X-ray absorption data were collected in fluorescence mode using an energy-resolving four-element monolithic germanium C-TRAIN-4 detector (Ortec) (Derbyshire et al., 1999). A silicon (111) double-crystal monochromator with an energy resolution of ∼1 × 10−4 eV was used (Cianci et al., 2005). spectra consisted of 168 data points over the energy range 8.96–9.11 keV with a dwell time of 1 s per point. Data were processed using the Daresbury Laboratory programs EXCALIB and EXBACK. X-ray diffraction data were measured using a MAR 225 CCD and processed using HKL2000 (Otwinowski & Minor, 1997), the structures solved by in PHASER (McCoy et al., 2007) and refined in REFMAC5 (Murshudov et al., 1997).
Each of the three crystallographic data sets (MX1, MX2 and MX3) consisted of 100 X-ray exposures each of 10 s. Following the collection of the second X-ray data set, a Cu K-edge spectrum was measured. An optical spectrum3 was collected from the crystal following each X-ray and the data set. We note that all optical and measurements were taken at the same crystal position and orientation in order to eliminate any changes in the spectrum that might arise from a change in orientation. In all cases, data using these three techniques were collected on the same crystal on-line at 100 K. Data collection parameters are given in Table 2.
|
The type-2 Cu centre is essentially optically silent, and so to monitor its status we have combined the information obtained from the Cu K-edge data with the crystal structures. The spectra following the determination of the second and third crystal structures are given in Fig. 3. Note that the 8984 eV edge feature, characteristic of the Cu(I) redox state in the T2Cu centre (Fig. 3 inset), is not observed, consistent with the T2Cu site remaining in the Cu(II) oxidized state although the optical data (not shown) indicate that the T1Cu centre is essentially completely reduced to Cu(I) at this point. The Cu–OH2 distance in the three crystal structures is similar to that expected for an oxidized T2Cu centre (Fig. 4, Table 3), suggesting that the of the T2Cu centre is much less rapid than that of the T1Cu centre and that structure MX3 is of the T1Cu(I)–T2Cu(II) form, i.e. where the two Cu centres are in different redox states.
|
4. Conclusions
A single-crystal microspectrophotometer has been successfully integrated into the fully tunable MAD beamline 10 at the SRS, resulting in the unique capability of measuring the on-line optical spectrum together with high-quality in situ. This development allows the monitoring of the status of metal centres in metalloproteins during a crystallographic experiment. The capability for such monitoring is becoming increasingly important with the higher X-ray doses which can be delivered by beamlines on third-generation synchrotron radiation sources. We have used crystals of the copper nitrite reductase from A. xylosoxidans as a test case. revealed that the T1Cu centre was rapidly reduced by exposure to X-rays. To determine the of the optically silent T2Cu centre, measurements were performed on the same crystal, showing that the edge features indicative of reduced T2Cu centres were not present. Combined with the diffraction data, these observations showed that the crystal structures collected were in the mixed T1[red]–T2[ox] form, consistent with previous biochemical, kinetic and structural observations on AxNiR in the solution state, that from T1Cu to T2Cu is gated (Strange et al., 1999; Hough et al., 2005). The combination of these three techniques applied to a single crystal allows monitoring of both optically active and optically silent metal centres during a crystallographic experiment. This approach provides a model for the design of MX/PX beamlines on current and future generations of synchrotron radiation sources.
and X-ray diffraction data from a crystalAcknowledgements
We thank Mr Neil Bliss, Mr Steve Postlethwaite and Mr David Robinson (Engineering and Instrumentation Department, STFC Daresbury Laboratory) for designing the microspectrophotometer mounting arc for the station. We thank STFC for provision of beam time and funds. Beamline 10 is supported by BBSRC grant number BBE001971 and the work on nitrite reductase by BBSRC grant number BBD0162901 to SSH.
References
Abraham, Z. H. L., Lowe, D. J. & Smith, B. E. (1993). Biochem. J. 295, 587–595. CAS PubMed Web of Science
Arcovito, A., Benfatto, M., Cianci, M., Hasnain, S. S., Nienhaus, K., Nienhaus, G. U., Savino, C., Strange, R. W., Vallone, B. & Della Longa, S. (2007). Proc. Natl. Acad. Sci. USA, 104, 6211–6216. Web of Science CrossRef PubMed CAS
Banci, L. & Assfalg, M. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 33–43. Chichester: John Wiley and Sons.
Bannerjee, R. V. & Matthews, R. G. (1990). FASEB J. 4, 1450–1459. PubMed Web of Science
Beitlich, T., Kühnel, K., Schulze-Briese, C., Shoeman, R. L. & Schlichting, I. (2007). J. Synchrotron Rad. 14, 11–23. Web of Science CrossRef CAS IUCr Journals
Bewley, M. C. & Flanagan, J. M. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 952–962. Chichester: John Wiley and Sons.
Bryngelson, P. A. & Maroney, M. J. (2007). Met. Ions Life. Sci. 2, 417–444. CAS
Burmeister, W. P. (2000). Acta Cryst. D56, 328–341. Web of Science CrossRef CAS IUCr Journals
Carpentier, P., Royant, A., Ohana, J. & Bourgeois, D. (2007). J. Appl. Cryst. 40, 1113–1122. Web of Science CrossRef CAS IUCr Journals
Chen, L., Durley, R. C. E., Mathews, F. S. & Davidson, V. L. (1994). Science, 264, 88–90.
Cianci, M. et al. (2005). J. Synchrotron Rad. 12, 455–466. Web of Science CrossRef CAS IUCr Journals
Colczak, U., Dennison, C., Messerschmidt, A. & Canters, G. W. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 1170–1194. Chichester: John Wiley and Sons.
Derbyshire, G., Cheung, K.-C., Sangsingkeow, P. & Hasnain, S. S. (1999). J. Synchrotron Rad. 6, 62–63. CrossRef CAS IUCr Journals
Di Iorio, E. I. (1981). Methods Enzymol. 76, 57–71. CrossRef CAS PubMed
Eicken, C., Gerdemann, C. & Krebs, B. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 1319–1329. Chichester: John Wiley and Sons.
Frank, P., Hodgson, K. O., Kustin, K. & Robinson, W. O. (1998). J. Biol. Chem. 273, 24498–24503. Web of Science CrossRef CAS PubMed
Hadfield, A. & Hajdu, J. (1993). J. Appl. Cryst. 26, 839–842. CrossRef CAS Web of Science IUCr Journals
Hasnain, S. S. & Hodgson, K. O. (1999). J. Synchrotron Rad. 6, 852–864. Web of Science CrossRef CAS IUCr Journals
Hasnain, S. S. & Strange, R. W. (2003). J. Synchrotron Rad. 10, 9–15. Web of Science CrossRef CAS IUCr Journals
Hough, M. A., Antonyuk, S. V., Strange, R. W., Eady, R. R. & Hasnain, S. S. (2008). J. Mol. Biol. 378, 353–361. Web of Science CrossRef PubMed CAS
Hough, M. A., Ellis, M. J., Antonyuk, S., Strange, R. W., Sawers, G., Eady, R. R. & Hasnain, S. S. (2005). J. Mol. Biol. 350, 300–309. Web of Science CrossRef PubMed CAS
Kisker, C. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 1121–1135. Chichester: John Wiley and Sons.
Latimer, M. J., Ito, K., McPhillips, S. E. & Hedman, B. (2005). J. Synchrotron Rad. 12, 23–27. Web of Science CrossRef CAS IUCr Journals
McCord, J. M. & Fridovich, I. (1969). J. Biol. Chem. 244, 6049–6055. CAS PubMed Web of Science
McCoy, A. J., Grosse-Kunstleve, R. W., Adams, P. D., Winn, M. D., Storoni, L. C. & Read, R. J. (2007). J. Appl. Cryst. 40, 658–674. Web of Science CrossRef CAS IUCr Journals
McPherson, M. J., Parsons, M. R., Spooner, R. K. & Wilmot, C. W. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 1272–1283. Chichester: John Wiley and Sons.
Meyer, J. & Moulis, J. M. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 505–517. Chichester: John Wiley and Sons.
Mozzarelli, A. & Rossi, G. L. (1996). Annu. Rev. Biophys. Biomol. Struct. 25, 343–365. CrossRef CAS PubMed Web of Science
Murray, J. W., Rudiño-Piñera, E., Owen, R. L., Grininger, M., Ravelli, R. B. G. & Garman, E. F. (2005). J. Synchrotron Rad. 12, 268–275. Web of Science CrossRef CAS IUCr Journals
Murshudov, G. N., Vagin, A. A. & Dodson, E. J. (1997). Acta Cryst. D53, 240–255. CrossRef CAS Web of Science IUCr Journals
Otwinowski, Z. & Minor, W. (1997). Methods Enzymol. 276, 307–326. CrossRef CAS Web of Science
Pearson, A. R., Pahl, R., Kovaleva, E. G., Davidson, V. L. & Wilmot, C. M. (2007). J. Synchrotron Rad. 14, 92–98. Web of Science CrossRef CAS IUCr Journals
Prudencio, M., Eady, R. R. & Sawers, G. (1999). J. Bacteriol. 181, 2323–2329. Web of Science PubMed CAS
Royant, A., Carpentier, P., Ohana, J., McGeehan, J., Paetzold, B., Noirclerc-Savoye, M., Vernède, X., Adam, V. & Bourgeois, D. (2007). J. Appl. Cryst. 40, 1105–1112. Web of Science CrossRef CAS IUCr Journals
Sakai, K., Matsui, Y., Kouyama, T., Shiro, Y. & Adachi, S. (2002). J. Appl. Cryst. 35, 270–273. Web of Science CrossRef CAS IUCr Journals
Schlichting, I., Berendzen, J., Chu, K., Stock, A. M., Maves, S. A., Benson, D. E., Sweet, R. M., Ringe, D., Petsko, G. A. & Sligar, S. G. (2000). Science, 287, 1615–1622. Web of Science CrossRef PubMed CAS
Strange, R. W., Murphy, L. M., Dodd, F. E., Abraham, Z. H. L., Eady, R. R., Smith, B. E. & Hasnain, S. S. (1999). J. Mol. Biol. 287, 1001–1009. Web of Science CrossRef PubMed CAS
Stroupe, M. E., DiDonato, M. & Tainer, J. A. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 941–951. Chichester: John Wiley and Sons.
Thompson, A. et al. (2001). X-ray Data Handbook, edited by D. Vaughan. Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
Wever, R. & Hemrika, W. (2001). Handbook of Metalloproteins, edited by A. Messerschmidt, R. Huber, T. Poulos and K. Wieghardt, pp. 1417–1428. Chichester: John Wiley and Sons.
Wilmot, C. M., Sjogren, T., Carlsson, G. H., Berglund, G. I. & Hajdu, J. (2002). Methods Enzymol. 353, 301–318. CrossRef PubMed CAS
Yano, J., Kern, J., Irrgang, K. D., Latimer, M. J. Bergmann, U., Glatzel, P., Pushkar, Y., Biesiadka, J., Loll, B., Sauer, K., Messinger, J., Zouni, A. & Yachandra, V. K. (2005). Proc. Natl. Acad. Sci. USA, 102, 12047–12052. Web of Science CrossRef PubMed CAS
Yano, J., Kern, J., Sauer, K., Latimer, M. J., Pushkar, Y., Biesiadka, J., Loll, B., Saenger, W., Messinger, J., Zouni, A. & Yachandra, V. K. (2006). Science, 314, 821–825. Web of Science CrossRef PubMed CAS
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.