- 1. Introduction
- 2. The factor of two
- 3. What is a MGy?
- 4. There are two kinds of radiation damage: global and specific
- 5. Crystals are killed by photons µm−2, not time
- 6. Beware of high atomic numbers
- 7. The `spreading' of radiation damage is ∼3 µm
- 8. Scavengers and radioprotectants
- 9. Helium
- 10. The minimum crystal size to solve a structure
- 11. Summary and general strategy recommendations
- References
- 1. Introduction
- 2. The factor of two
- 3. What is a MGy?
- 4. There are two kinds of radiation damage: global and specific
- 5. Crystals are killed by photons µm−2, not time
- 6. Beware of high atomic numbers
- 7. The `spreading' of radiation damage is ∼3 µm
- 8. Scavengers and radioprotectants
- 9. Helium
- 10. The minimum crystal size to solve a structure
- 11. Summary and general strategy recommendations
- References
radiation damage
A beginner's guide to radiation damage
aDepartment of Biochemistry and Biophysics, University of California, San Francisco, CA 94158-2330, USA, and bAdvanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
*Correspondence e-mail: jmholton@lbl.gov
Many advances in the understanding of radiation damage to protein crystals, particularly at cryogenic temperatures, have been made in recent years, but with this comes an expanding literature, and, to the new breed of protein crystallographer who is not really interested in X-ray physics or
but just wants to solve a biologically relevant structure, the technical nature and breadth of this literature can be daunting. The purpose of this paper is to serve as a rough guide to radiation damage issues, and to provide references to the more exacting and detailed work. No attempt has been made to report precise numbers (a factor of two is considered satisfactory), and, since there are aspects of radiation damage that are demonstrably unpredictable, the `worst case scenario' as well as the `average crystal' are discussed in terms of the practicalities of data collection.Keywords: radiation damage; minimum crystal size; protein macromolecular crystallography; dose doubling; radioprotectant; data collection strategy.
1. Introduction
It is not uncommon for radiation damage to prevent the solution of a structure. Diffraction spots can fade away before the data set is complete and heavy atoms sites can become disordered before sufficient anomalous signal is measured. The former is easy to detect by eye during data collection, but the latter is more insidious (Holton, 2007; Oliéric et al., 2007). In either case, however, significant damage by the middle of the data set generally means that the data set is already ruined. What is more, the specific chemical changes induced by radiation damage can change the structure from the biologically relevant form, and this sometimes leads to wrong conclusions about function.
Radiation damage can be avoided by keeping the accumulated X-ray exposure short, but how short is short enough? How short is too short to solve the structure? Does it matter how bright the beam is? Is there anything that can be done during sample preparation or data collection that can mitigate or at least predict radiation damage?
There are several good reviews and broad reports on the field of radiation damage (Garman & McSweeney, 2007; Ravelli & Garman, 2006; Carugo & Carugo, 2005; Nave & Garman, 2005; Garman, 2003; Garman & Nave, 2002; Ravelli & McSweeney, 2000; Burmeister, 2000; Helliwell et al., 1993), and the reader is referred to these works for comprehensive coverage of the field. What follows is a rough guide focusing on damage avoidance.
2. The factor of two
The cut-off of a factor of two for a radiation damage effect to be considered significant here was chosen because a factor of two in scattering power corresponds to a relatively small change in crystal size. Specifically, increasing all three linear dimensions of a crystal by 26% will double the volume of scattering matter (1.263 = 2). Such a change in size appears to be a typical `error bar' when examining crystals under a microscope, as most crystallographers will not distinguish between an 88 µm crystal and a 110 µm crystal, but the latter has twice the volume of the former and the number of photons a crystal will diffract before it is `dead' is proportional to volume (see Appendix A). Perhaps more attention should be paid to crystal size, but a factor of two can also be the uncertainty in X-ray beam intensity, especially if parameters such as the variability in storage ring current over a refill cycle are not taken into account. Increasing the exposure time by a factor of two will double the damage but increase the signal/noise ratio of the data by only ∼42% (1 versus 21/2), an improvement which can be difficult to detect by inspecting a diffraction image, and in practice a factor of four in exposure time is generally needed to see new spots. A factor of two is also roughly the difference between collecting one wavelength or two (all other things being equal, such as the per-image exposure time), collecting the inverse beam wedge or not, and also the difference between collecting from one crystal or merging data from two crystals. So, a factor of two roughly corresponds to the decision thresholds that must be faced in data collection strategy.
3. What is a MGy?
The −2 s−1) of current synchrotron X-ray beams varies by a factor of ten thousand (Holton, 2008; Kuller et al., 2002; https://biosync.rcsb.org/), so describing radiation damage in terms of `frames' is not useful when trying to apply strategies learned using one beamline at another. A more transferrable unit is needed.
(photons µmThe Gy (J kg−1) is the SI unit of dose, which is the amount of energy absorbed by something per unit of mass, and protein crystals are typically given millions of Gy, so the MGy is a convenient unit. Obviously, the extent of radiation damage will depend on the number of photons absorbed, but it is not so much the photons themselves as the energy they carry that drives the chemical reactions of damage (Newton, 1963; Myers, 1973; Box, 1977), so it is most relevant and useful to describe damage in terms of dose. Note that fluence (incident photons µm−2) is sometimes incorrectly referred to as a dose, but the SI definition of dose is absorbed energy, not incident energy, and the correct meaning of the word `dose' will be used here.
The relationship between fluence and dose depends on the X-ray wavelength and the atomic composition of the sample (see §6), but typically only a tiny fraction of the X-ray beam is absorbed by a protein crystal (usually ∼2%) so dose is generally independent of crystal size and directly proportional to fluence (incident photons µm−2). Typically, this `dose ratio' (kdose) is ∼2000 photons µm−2 Gy−1. That is, a dose of 1 MGy will be deposited in a metal-free crystal after 20 s in a 100 µm × 100 µm beam of 1 Å X-rays with a of 1012 photons s−1. Note that if the crystal is bigger than the beam, then the dose to the part exposed to the beam will be proportional to incident photons µm−2 (see §7).
Neglecting the crystal thickness does introduce a small error. The actual dose will always be a little less than that given by kdose, but the error introduced is less than a factor of two as long as the crystal is thinner than the attenuation depth of the X-rays, which is 3600 µm in the above case. The error is less than 5% if the crystal is smaller than 370 µm thick.
The X-ray wavelength has a strong effect on kdose and the exact dependence can be complicated (Hubbell, 2006; Seltzer, 1993). However, the empirical formula
where kdose is the dose ratio (photons µm−2 Gy−1) and λ is the X-ray wavelength (Å), is accurate to within 15% for 0.5 Å < λ < 3 Å. In fact, the simple assumption kdose = 2000 photons µm−2 Gy−1 is accurate to within a factor of two for wavelengths between 1.1 and 0.9 Å. However, equation (1) assumes that no heavy (heavier than sulfur) atoms are in the crystal or solvent channels, and it may be off by much more than a factor of two if the heavy-atom concentration in the crystal is greater than ∼100 mM (see §6 and Table 1). For accurate determination of kdose for an arbitrary wavelength and crystal formulation, use RADDOSE (Murray et al., 2004, 2005; Paithankar et al., 2009), but, even if kdose is uncertain, the lifetime (in seconds) of crystals with given elemental composition at a given wavelength will always be inversely proportional to (photons µm−2 s−1) when moving from one beamline to another, or as a given beamline is attenuated. Thus it is important to know the beamline (photons s−1) as well as the size of the beam at the crystal (µm2) (see §11).
It is also very important to remember that, like dose, diffracted intensities are proportional to fluence (photons µm−2) and have a rough λ2 wavelength dependence, but unlike dose they are relatively insensitive to heavy atom content. That is, for a given exposure time at a given X-ray wavelength, the amount of information obtained will depend on how many photons were thrown at the crystal, but the amount of damage inflicted will depend on how many were absorbed. Therefore, at some fixed wavelength, the value of kdose is a good indicator of how much data a crystal will yield in its useful life relative to another crystal of the same size and type but different heavy atom content (see §6). A lower kdose is better.
4. There are two kinds of radiation damage: global and specific
Irradiated protein crystals suffer an overall loss of resolution as high-angle spots fade away which is referred to as global damage. There are also specific chemical changes that can be seen in the electron density maps, such as side chains popping off. Specific damage can be up to ∼60 times faster than global damage (see below), but the good news is that at cryogenic temperatures the global damage `rate' appears to be essentially the same for every protein crystal, once `lifetime' has been normalized to dose (Garman & McSweeney, 2007; Owen et al., 2006; Leiros et al., 2006; Sliz et al., 2003). In fact, the term `damage rate' is something of a misnomer since the words `rate' and `lifetime' imply progression with time but the fundamental coordinate of cryogenic damage is dose. For this reason we introduce the term `lifedose' to refer to the amount of dose a crystal can endure, and the word `lifetime' will be used to indicate time.
Owen et al. (2006) recommended a general (lifedose) of 30 MGy but noted there was also some resolution dependence to this as high-angle spots faded first. In fact, there is a remarkably linear relationship between scaling B factor and dose (Kmetko et al., 2006; Borek et al., 2007), but Howells et al. (2005) proposed a resolution-dependent dose limit criterion of 10 MGy per Å of resolution. For example, if a resolution of 3 Å is desired, the Howells criterion suggests a lifedose of 30 MGy. Since most of the dose limits used to derive this criterion used spot fading to half intensity as the indication of a dose limit, the fading of a spot at a given resolution can be supposed to follow an exponential decay,
where I is the radiation-damaged spot intensity, I0 is the spot intensity at zero dose, ln(2) is the natural log of two (∼0.7), D is the dose in MGy, d is the d-spacing in Å and H is Howells et al. (2005) criterion (10 MGy Å−1). Note that, in equation (2), I = 0.5I0 when D in MGy is ten times the d-spacing in Å. This is not exactly the definition of d given by Howells et al. (2005), but equation (2) agrees remarkably well with recent damage studies. For example, applying equation (2) to the square structure factors of apoferritin [Protein Data Bank (PDB) ID: 2clu] results in a fairly linear fall-off of total intensity with dose that reaches half intensity at 42 MGy (not shown) which is consistent with 43 ± 3 MGy observed at half total intensity by Owen et al. (2006). In addition, scaling these same exponentially modified apoferritin data to unmodified intensities with SCALEIT (Howell & Smith, 1992) results in a best-fit relative B factor that increases linearly with dose having a slope of 1.3 B-factor units per MGy (B MGy−1), which is identical to the slope reported by Kmetko et al. (2006) for their apoferritin observations. Application of this same resolution-dependent spot-fading rate to lysozyme data (PDB ID: 2blx) reproduces the 1.03 B MGy−1 that Kmetko et al. (2006) reported for lysozyme, and thus explains the apparent protein-to-protein variability they observed. It is worthwhile noting that the sum of all diffracted intensities reduces by half if one applies a B factor of 15 to the apoferritin data, but this corresponds to a dose of 11 MGy using the slope 1.3 B MGy−1, a result that would be inconsistent with those of Owen et al. (2006) if damage manifested as a simple B factor. This is because the B factor has a resolution dependence of exp(−1/d2), not the exp(−1/d) found by Howells et al. (2005). The Howells criterion of 10 MGy Å−1 therefore appears remarkably consistent with the observations of recent damage studies and is recommended as a good rule of thumb for predicting the lifedose of spots at a given d-spacing.
The bad news is that the rates of specific damage reactions are variable and depend on many factors including the folded structure of the protein (Holton, 2007), so there will probably never be a way to predict them before the structure is solved. This problem is exacerbated by the fact that `interesting' parts of the molecule such as active sites, bound ligands and heavy-atom sites are particularly prone to specific damage. One might presume that this trend has anthropogenic origins because these are the parts of the protein where people spend the most time looking, but many systematic studies have now been carried out, and the trend does appear to be real (Burmeister, 2000; Ravelli & McSweeney, 2000; Weik et al., 2000, 2001; Leiros et al., 2001; O'Neill et al., 2002; Nukaga et al., 2003; Fuhrmann et al., 2004; Carugo & Carugo, 2005; Dubnovitsky et al., 2005; Roberts et al., 2005; Yano et al., 2005; Leiros et al., 2006; Fioravanti et al., 2007; Schiltz & Bricogne, 2007). The mechanism of site-specific radiosensitivity is still unclear. Several mechanisms for the high sensitivity of particular sites have been proposed, such as solvent accessibility (Burmeister, 2000; Weik et al., 2002; Garman & Nave, 2002), the high X-ray cross sections of heavy atoms (refuted by Southworth-Davies et al., 2007), chemical bond strain (Weik et al., 2000; Fuhrmann et al., 2004; Dubnovitsky et al., 2005; Fioravanti et al., 2007) and electrostatic field lines (Holton, 2007). For each of these models, there is both evidence and counter-examples, and the reader is referred to the above references for details. It will suffice here to say that there are probably at least two different radiochemical mechanisms at work, and the lifedose of any given site depends on its location in the structure.
Despite this inherent unpredictability, there are `world records' for lowest lifedose of specific damage reactions: 2 MGy for selenomethionine (Holton, 2007), 0.5 MGy for bromouracil (Oliéric et al., 2007) and as little as ∼0.3 MGy for the metalloprotein putidaredoxin (Corbett et al., 2007), and these `worst case scenarios' can be used when planning data collection (see §11).
5. Crystals are killed by photons µm−2, not time
One of the most remarkable findings about cryogenically cooled protein crystals is that global damage is proportional to dose, but not how fast that dose was delivered: the `dose rate' (Garman & McSweeney, 2007; Sliz et al., 2003; Leiros et al., 2006; Owen et al., 2006). This is certainly not the case at room temperature, where the extent of damage inflicted by a given dose does depend on the dose rate (Blake & Phillips, 1962; Southworth-Davies et al., 2007), varies from protein to protein and even continues damaging the crystal after the X-rays have been turned off (Blundell & Johnson, 1976). However, unless stated otherwise, the discussion in this paper is about damage at cryogenic temperatures.
The exact timescale (and indeed the nature) of the cryogenic global damage reaction is not clear, but it must be very fast to have no dose-rate dependence and a lack of any demonstrable `dark progression'. Whatever reactive species are generated by the beam, they must be consumed as fast as they are made, or their concentration would build up at high dose rates, saturating the downstream reactions. This means that as long as a partially `burnt' crystal is stored properly (such as described by Owen et al., 2004) it will stay at liquid-nitrogen temperatures and diffract to the same resolution at a later time, even when restored to the beamline months later (not shown).
Specific damage is more complicated because a dose-rate dependence has been demonstrated (Leiros et al., 2006) and damaged species have also been observed spectroscopically to disappear with a time scale of minutes after the beam has been turned off (Weik et al., 2002; Southworth-Davies & Garman, 2007; McGeehan et al., 2009). Nevertheless, no reported dose-rate dependence has been more than a factor of two. That is, the accumulated dose required to inflict a given quantity of damage (measured as site occupancy, scaling B factor or total diffracted intensity) has not been shown to change by more than a factor of two as a result of changing the dose rate. Consequently, dose-rate dependence will be considered insignificant here, and the reader is referred to the above references to learn more about it.
A very important consequence of the dose-rate independence of radiation damage is that the quality of data that can be obtained from a crystal before it is `dead' will not change no matter how rapidly the photons are applied (flux or photons s−1). This is because the data are derived from scattered photons and scattering is exactly proportional to fluence (photons µm−2), which has no dimensions of time. This fact can be found in any of the many good books describing the physics of X-ray diffraction, such as Blundell & Johnson (1976) or Drenth (1999), with rigorous proofs given by Woolfson (1970) or James (1962). There are other parameters of beam quality such as collimation, spectral purity, crossfire and flicker noise which can impact data quality in various ways that will not be covered here, but (photons s−1) by itself does not affect data quality until it is converted into fluence (photons µm−2). Therefore, since there appears to be no significant dose-rate dependence to damage, the extent of damage is also proportional to fluence (photons µm−2), and the data-to-damage ratio is independent of the time taken to collect the data.
In the future, it may eventually become possible to collect data on timescales faster than the chemical reaction rates involved in damage, which will introduce a beneficial dose-rate effect. Exactly what this timescale must be is not presently clear as the rate constants (and indeed the mechanisms) of these reactions are not known.
6. Beware of high atomic numbers
The lifetime of a crystal in a given X-ray beam depends on the elemental composition of the crystal and the solvent inside it. Unlike visible light, X-rays are absorbed by all of the electrons in an atom, and the Z2.7 where Z is the This means that absorption goes up very steeply moving across and down the periodic table. For example, 600 mM NaI instead of 600 mM NaCl in solvent channels (assuming solvent is 50% of the total volume) will cut the lifetime of a crystal roughly in half (see Kmetko et al., 2006), but, since absorption is proportional to concentration, lower concentrations of NaI are less of a problem. Note that we are discussing lifetime and not lifedose, as the latter is remarkably unaltered by heavy atom content.
increases roughly asPrecise X-ray absorption cross sections have been tabulated (McMaster et al., 1969; Hubbell, 1982, 2006), and Seltzer (1993) generated effective cross sections accounting for energy-loss mechanisms such as (which is ∼40% in the case of Se atoms) and assumed no self-absorption of fluorescent X-rays. The Seltzer (1993) tabulations were used to produce Table 1 because the error introduced by neglecting self-absorption is usually quite small (much less than a factor of two), and this correction was discussed in detail by Paithankar et al. (2009).
Table 1 was also made with the assumption that protein crystals and pure water have the same absorption. Although the average X-ray of protein atoms is lower than that of water, the higher density of protein (∼1.34 g cm−3) tends to make up the difference. As long as the sample is free of heavy atoms, the dose (energy absorbed per unit mass) deposited by a given beam of X-rays in a thin layer of protein crystal is within 5% of that deposited in a thin layer of pure water for all photon energies between 5 and 50 keV.
Using these assumptions, the concentration of a given element that will cut a protein crystal lifetime in half (by doubling kdose) may be calculated. This concentration is moles of the element per litre of sample, not the molarity of the solution in the solvent channels. For example, if we fill the solvent channels of a protein crystal with a solution containing 680 mM of selenium, then the total concentration will be roughly 340 mM (assuming 50% solvent content and that the selenium compound does not bind to the protein).
Consider the photon energy to be 12680 eV. The mass energy absorption ) provided for water at this energy is 2.3 cm2 g−1, so exposing a thin layer of water to a fluence of 106 photon cm−2 will deposit 2.9 × 1010 eV cm−3 (106 photon cm−2 × 2.3 cm2 g−1 × 12680 eV photon−1 × 1.0 g cm−3) of energy. The mass energy absorption of selenium at this energy is 87 cm2 g−1, so a gas of selenium atoms at 27 mg cm−3 will absorb the same amount of energy per unit volume as water (106 photons cm−2 × 87 cm2 g−1 × 12680 eV photon−1 × 0.027 g cm−3 = 3.0 × 1010 eV cm−3). Therefore, an aqueous solution containing 27 mg cm−3 (340 mM) selenium will absorb roughly twice as much energy as pure water or a native protein crystal.
that Seltzer (1993If we consider lighter atoms, then the volume occupied by the solute can become significant and must be taken into account. For example, 14 mol L−1 of sodium will absorb as much energy as an equal volume of water, but a 14 M aqueous solution of sodium will contain significantly less water per unit volume than pure water, and therefore absorb less than twice as many X-rays as pure water. If we assume that each sodium atom displaces one water molecule, then 19 M sodium is required to double the dose. Very light elements absorb fewer X-rays per atom than the water they displace, and adding lithium will actually reduce the total X-ray absorption. However, cutting the X-ray absorption in half requires displacing more than half of the water, or roughly 28 M Li, a practical impossibility.
Table 1 was calculated as above using X-rays at the Se edge (0.9793 Å) and these dose-doubling concentrations will be different at other wavelengths. As an extreme example, the dose-doubling concentration of Br is ∼1.2 M at 0.9793 Å (below the Br K-edge) but this will drop to 320 mM at 0.9193 Å (above the Br K-edge). To calculate exactly how a particular crystal composition will behave at a particular wavelength, use RADDOSE (Murray et al., 2004, 2005; Paithankar et al., 2009). However, to within a factor of two anything at less than ∼100 mM is `safe'. Note, however, that this does not mean 99 mM is the same as 0 mM; the effect is proportional to concentration.
7. The `spreading' of radiation damage is ∼3 µm
Cryo-cooled protein crystals are solids, and this is evident if they are mounted with the wrong size cryo-tongs: the droplet containing the crystal can be crushed or shattered like any other glass. Since the viscosity of a glass is incredibly high, there can be no diffusion of radicals in the traditional sense (Douzou, 1977). That is, there is no mass transport except on geological timescales (thousands to millions of years). There is also not enough energy in available X-ray beams to heat a crystal by more than a few degrees (Snell et al., 2007). This is not to say that massless reactive species cannot move as much as a few dozen angstroms or more in a glass, they can (Box, 1977; Petrik & Kimmel, 2003, 2004), but this is solid-state chemistry, which is very different from in aqueous solution at room temperature (Zagórsky, 1999).
It is possible to shoot one part of the crystal so much that it expands physically and the strain induced by this expansion distorts the lattice of neighbouring regions of the crystal (not shown), but the bulk of data collected at the Advanced Light Source beamline 8.3.1 (MacDowell et al., 2004) by `walking' down needle crystals shows no signs of damage `spreading' any more than a few micrometres, and a systematic study by Schulze-Briese et al. (2005) found that damage is indeed limited to the irradiated area. Since the range of a ∼10 keV photoelectron in organic matter is ∼3 µm (Cole, 1969), there is no physical reason to think that damage `travels' any further than that. Conversely, half of the absorbed energy should escape a crystal which is smaller than ∼40% of the photoelectron range (Nave & Hill, 2005), but a practical demonstration of this effect has yet to appear in the literature.
8. Scavengers and radioprotectants
There are now seven molecules that have been reported to have a protective impact on specific radiation damage including ascorbate (Murray & Garman, 2002; O'Neill et al., 2002; Betts, 2004; Southworth-Davies & Garman, 2007; Holton, 2007), nicotinic acid and DTNB (5,5′-dithiobis-2-nitrobenzoic acid) (Kauffmann et al., 2006), nitrate ion (Borek et al., 2007; Holton, 2007) and 1,4-benzoquinone, TEMP (2,2,6,6-tetramethyl-4-piperidone) and DTT (dithiothreitol) (Southworth-Davies & Garman, 2007). These workers also found a much longer list of substances that have no effect.
As for global damage, Kauffmann et al. (2006) and Murray & Garman (2002) both reported a protective effect from the additives listed above. Murray & Garman (2002) did not claim more than a factor of two change in any of the metrics used, but Kauffmann et al. (2006) reported better than a factor of two impact on both global and specific damage. Unfortunately, the results reported by Kauffmann et al. (2006) were not normalized for dose nor for scattering power (see §10), so it is difficult to assess the impact of these additives on a transferrable scale. Nevertheless, if a crystal is found to tolerate the presence of any of these additives, it is advisable to try them.
9. Helium
At any temperature, using helium gas instead of nitrogen will reduce background scattering (Polentarutti et al., 2004), and this effect is particularly prominent inside the `water ring' (d-spacings between 3.8 Å and the beam stop) where helium scatters 1/49th as much as air. At the water ring and higher angles, the scattering from the sample is roughly equivalent to that of 1000 times its thickness of air, which tends to overwhelm air scatter unless the air path is more than 1000 times longer than the sample is thick. For example, a 3 cm air path is significant if the sample (crystal + cryosolvent) is 20 µm thick, but not if the sample is 200 µm thick. Some of the historical confusion about the benefits of helium arose from the need to de-convolute this effect, but the more recent studies have taken it into account. Nevertheless, from a data collection standpoint, the background reduction alone can be a good enough reason to use helium, even at 100 K.
As with radioprotectants, there have been plenty of negative results attempting to use temperatures lower than 100 K to reduce radiation damage and a few have even been published (Meitzner et al., 2005), but there are now several reports of significant reduction of specific damage at temperatures from 7 to 40 K (Yano et al., 2005; Grabolle et al., 2006; Corbett et al., 2007). All of these reports were reductions in active site damage of metalloproteins ranging from factors of two to a factor of 30 in Corbett et al., but this does not mean that helium temperatures will not slow down other specific damage reactions.
As for global damage, there certainly are reports of a positive impact from helium cryostats (Teng & Moffat, 2002; Hanson et al., 2002; Chinte et al., 2007; Borek et al., 2007; Meents et al., 2007), but no reports thus far have claimed better than a factor of two in sample lifedose. Greater than a factor of two reductions in global damage has been reported in cryo-electron microscopy, but the benefits of helium are still controversial in this field (Massover, 2007; Glaeser, 2008).
10. The minimum crystal size to solve a structure
It was shown in §4 that diffraction spots from any protein crystal at a given d-spacing will fade with essentially the same lifedose, so the amount and quality of data that can be collected before a crystal `dies' will depend on the initial scattering power of the crystal. For example, given a particular data-quality goal, crystals with larger unit cells will have to be bigger than those with smaller unit cells because spot intensity is proportional to the number of unit cells in the beam. The relationship between all the factors affecting scattering power and radiation damage is detailed in Appendix A, where the number of crystals of a given type and size needed to solve a structure is derived,
where nxtals is the number of crystals required to solve the structure, n0 is the number of crystals required in a unitary reference case (see below and Table 2), ℓxyz is the crystal size in each direction (µm), MW is the molecular weight (kDa), VM is the Matthews number (Å3 Da−1), d is the d-spacing of interest (Å) and B is the Wilson B factor (Å2). The crystal size, molecular weight, approximate VM and resolution of interest are all readily available quantities to the crystallographer screening crystals, but it can be difficult to know the Wilson B factor a priori. A survey (not shown) of the PDB (Berman et al., 2000) revealed a simple relationship between the resolution limit (dmin) and the average atomic B factor of entries claiming that resolution limit,
which holds in the range 1.5 Å < dmin < 4 Å. Whatever the reason behind this trend, Bavg is empirically a rough estimate of the Wilson B factor of a crystal that appears to diffract to dmin on initial screening diffraction images and this can be substituted into equation (3).
‡Taken from 400 µm3 illuminated volume quoted by Moukhametzianov et al. (2008) and 5 µm beam. |
The value of the empirical `difficulty parameter' n0 will depend on the type of experiment to be attempted, and it can be interpreted as the number of crystals required when the fraction in equation (3) is equal to 1.0, such as 5 × 5 × 5 µm lysozyme crystals with Wilson B = 21 and d = 2 Å. Experiments with higher data quality requirements (see below) will have larger values of n0, but improvements in methodology and equipment are expected to lower n0 for a given experiment.
The usefulness of equation (3) is demonstrated in Table 2. It can be seen that n0 for the goal of obtaining a complete native data set has been decreasing over time but has never been less than 3. Therefore, using n0 = 3 in equation (3) is a good way to gauge whether trying to obtain a complete data set is hopeless. That is, if plugging in the parameters of a crystal of interest and n0 = 3 results in nxtals > 1, then obtaining a complete data set from a single crystal would be a record-setting feat. It is not recommended to try to set new records with projects that might require more than just a complete data set. That is, 90% complete data may be sufficient for and to succeed, but the integrity of important chemical bonds can be questionable at n0 = 3.
A case in point is MAD/SAD structure solution, as it was noted in §4 that metal sites can break down up to 60 times faster than the observed decay of spot intensities. This implies that, for `safe' by MAD or SAD, n0 should be increased ∼60-fold to n0 = 180. Covalent bonds in active sites and ligands can break rapidly as well, but these decay rates are currently not well characterized, so, if breaking a particular bond would change the conclusions derived from the structure, a recommended strategy is to use n0 ≃ 180. For example, the high value of n0 for the 3.5 Å structure of the ribosome (Schuwirth et al., 2005 in Table 2) is due to the fact that care was taken to avoid any signs of radiation damage in those data (∼2 MGy per crystal) and that the dose ratio (kdose) of is about twice that of protein (owing to phosphorous content). In general, addition of any of the dose-doubling concentrations listed in Table 1 requires doubling the value of n0. This is because n0 is linear with dose.
Note that a value of nxtals greater than 1 does not mean that the crystal should be discarded. Walking a small beam down a needle crystal to nxtals different locations and merging the data will satisfy equation (3). Remember that the beam size will `cut off' the effective crystal dimensions (see §7) and that should be reflected in the values of ℓx, ℓy and ℓz because the product of these three numbers is the volume of scattering matter. For example, a 10 × 10 µm beam on a crystal 100 µm in all dimensions is equivalent to a crystal and beam which are 22 µm in all dimensions, because 10 × 10 × 100 = 104 and 22 × 22 × 22 ≃ 104. However, rotating a large crystal in a small beam will change the effective exposed volume as well (see below).
11. Summary and general strategy recommendations
Radiation damage begins with the first X-ray photon absorbed in the crystal, so data collection strategy must always be a balance between the data quality required and the amount of damage than can be tolerated. It is often the case that this balance cannot be struck with just one crystal and perhaps not even with many if the crystals are very small and very weakly diffracting. So, given a new and very precious protein crystal, how shall one proceed with data collection?
The first thing that must be known about a beamline or other X-ray source is the φ) in photons s−1, and this can be obtained using a calibrated photodiode (Owen et al., 2009). The next parameters to obtain are the dimensions of the beam at the crystal (ℓHbeam and ℓVbeam), as these are needed to compute the (photons µm−2 s−1). If these are not readily available, they can be obtained by exposing a small piece of silica glass (such as a cover slip) which will turn brown in the X-ray beam. If necessary, this darkened glass can be transferred to a microscope with a calibrated reticule for measurement of the beam size.
(Once the −2 s−1) is known, all that remains is the dose ratio (kdose) which is usually 2000 photons µm−2 Gy−1, but can also be calculated more precisely for a given wavelength and chemical composition of the crystal using RADDOSE (Murray et al., 2004, 2005; Paithankar et al., 2009). Given all these, the maximum recommended shutter-open time a crystal will endure can be calculated,
(photons µmwhere txtal is the maximum shutter-open time for a data set (s), D is the expected lifedose of the crystal (Gy), kdose is the dose ratio (∼2000 photons µm−2 Gy−1), φ is the beam (photons s−1), ℓHbeam is the dimension of the X-ray beam spot along the spindle direction (µm) and ℓVbeam is the dimension of the X-ray beam spot perpendicular to the spindle (µm). Some data collection strategy programs such as BEST (Bourenkov & Popov, 2006) can take txtal as input, but it is instructive to examine its meaning here. For example, if it is desired to collect a complete data set to 2 Å resolution, then we obtain D = 20 × 106 Gy using the Howells criterion (see §4). Assuming the X-ray wavelength is ∼1 Å (see §3) and no heavy-atom concentration is above 100 mM (see §6), the kdose given above will roughly apply, and, using a beam 100 µm high and 200 µm wide with 1 × 1012 photons s−1, we obtain txtal = 800 s. This means that a data set of 100 images should use a per-image exposure time of 8 s or less. A 3 Å data set, however, could use 12 s exposures.
Note that txtal is proportional to d via the Howells criterion, but this does not imply that shorter txtal will yield better resolution; rather, measuring high-angle spots must be done quickly because they will endure less dose than low-angle spots. Increasing (photons s−1) will also reduce txtal, which means that the data can be collected faster, but the number of photons scattered into the detector before the spots fade away will not change. This is a consequence of the lack of a significant dose-rate dependence to radiation damage (see §5).
On general terms it is recommended to try to match the size of the beam to the size of the crystal as this optimizes the ratio between diffracted intensities and background scattering. However, this is not always possible and care must be taken when considering a mismatch in size between the beam and the crystal. Equation (5) is based on the assumption that the crystal is `bathed' in the X-ray beam, and a crystal larger than the beam and rotating will complicate the dose calculation as `fresh' and `partially burnt' crystal matter moves in and out of the illuminated region. This process can be roughly accounted for by assuming that the average dose (total energy absorbed divided by the total mass that absorbed it) applies. The correction to equation (5) is then the cross-sectional area of the exposed region of the crystal (viewed down the spindle axis) divided by the average path length traversed by the beam through the crystal as it rotates. This correction is indeed geometrically involved, but a reasonable approximation to it (within 25%) is achieved by replacing ℓVbeam in equation (5) with the geometric mean of the two crystal dimensions perpendicular to the spindle [(ℓxℓy)1/2].
For example, consider a crystal that is a cylindrical rod 50 µm in diameter and 1 mm long with the long dimension oriented along the rotation axis. If this crystal is centred in a 10 × 10 µm beam and the data collection rotates it by 180°, then the exposed volume is a 50 µm-diameter disc, 10 µm thick (volume ≃ 20 × 103 µm3), but the total energy absorbed is identical to that of a 10 × 10 × 50 µm exposed volume (5 × 103 µm3) that did not rotate. The average dose (J kg−1) is therefore four times less than that assumed by equation (5) as written, and txtal will actually be four times longer. Replacing ℓVbeam in equation (5) with (ℓxℓy)1/2 = 50 µm is more accurate, but actually represents a 25% over-correction in this case. This over-correction is less if the exposed region of the crystal has a rectangular (viewed down the spindle axis). In fact, it can be shown that the result obtained by numerically integrating the average dose to such a rectangular illuminated volume is quite similar to that obtained from equation (5) after replacing ℓVbeam with (ℓxℓy)1/2. The difference ranges between a 12% over-correction to a 25% under-correction when the ratio of the crystal edges (ℓx:ℓy) ranges from 1:1 to 10:1 (respectively).
If the beam profile is a `top hat' with even illumination at every point (constant −1 µm−2) then crystals smaller than the beam will still obey equation (5). However, if a small crystal is in a `hot' central region of a larger beam, it will burn up faster than predicted by equation (5), since it is actually experiencing the (photons s−1 µm−2) passing through its own cross-sectional area (looking down the beam). For example, a Gaussian beam profile will have a peak that is 88% of the `average' assumed by entering the whole-beam (photons s−1) as φ and the two full width at half-maximum (FWHM) dimensions of the beam profile as ℓHbeam and ℓVbeam in equation (5). Similarly, a `round' crystal that exactly matches the FWHM dimensions of a Gaussian beam will experience 50% of the whole-beam φ (photons s−1). Crystals in such beams can therefore be expected to last roughly 13% longer or twice as long as predicted by equation (5), respectively. This is not a radiation-protective effect of Gaussian beams, but merely an artefact of computing density.
or photons sIt is noteworthy that equation (5) is still accurate to within a factor of two despite all these caveats (providing it is corrected for the large crystal rotating in a small beam case), but significantly more accurate sample lifetimes given different beam shapes and sample sizes can be obtained using RADDOSE (Murray et al., 2004, 2005; Paithankar et al., 2009).
The above example uses the Howells criterion for the lifedose of global damage, but if specific damage is a concern then the lifedose of the relevant reaction should be used. For example, selenomethionine sites have never been observed to be more than half-decayed after a dose of 2 MGy (Holton, 2007), and using this value for D in the example above we obtain a maximum per-image exposure time of 0.8 s. This is an example of why it is generally necessary to grow larger and higher-quality crystals for MAD/SAD structure solution than for a complete data set, as the former will diffract more photons into the detector for a given exposure time.
It will often be the case that a diffraction image taken with the exposure time recommended by equation (5) will have an unsatisfactory appearance, such as the absence of high-angle spots that were clearly evident on a longer exposure. This generally means that the crystal at hand will not yield enough data to meet the specified goals. The next step is therefore either to change the crystal or change the goals. For example, if it is decided that only 10 s exposures are satisfactory, but selenomethionine decay is a concern, then txtal = 80 s implies that only eight images can be collected before there is a danger that some of the sites have become disordered. However, some selenomethionine side chains are particularly hardy, so it is prudent to continue collecting data until the spots fade away with the caveat that only the first eight images may contain anomalous signal. There are two ways to address this caveat.
(i) If more than one crystal is available, then an advisable strategy is to combine the first ∼2 MGy worth of data from several crystals into a composite data set. In this case care must be taken to collect the early data from each crystal in different regions of et al. (1960) and employed more recently by Facciotti et al. (2003).
This technique was developed by Kendrew(ii) If only one crystal is available, or non-isomorphism between crystals is problematic, then resolution must be sacrificed in order to obtain complete data. In this case, it is recommended to collect a complete data set with short exposures first (i.e. the 0.8 s exposures in the above example) and then keep collecting additional complete data sets, multiplying the exposure time by a factor of three each time. This protocol not only extends the effective of the detector, but roughly doubles the overall signal/noise ratio with each new data set if everything is merged together in the end. Merging is recommended if there are no signs of damage. Signs of global damage are an increasing scaling B factor (Kmetko et al., 2006; Borek et al., 2007), and a reduced anomalous signal (Ranom or CCanom; Evans, 2006) is an excellent indicator of specific damage to metal sites. If rapid specific damage is evident, then merge the early and late data separately and treat them as RIP data (Ravelli et al., 2003, 2005; Nanao et al., 2005; Banumathi et al., 2004; Zwart et al., 2004). In this way, the same collection strategy can be used for two different structure-solving pathways: RIP will be appropriate if the damage was fast, and MAD/SAD if it was slow.
APPENDIX A
Derivation of equation (3)
The ratio of scattered to incident photons has been referred to as the scattering power of a crystal (Sliz et al., 2003; Teng & Moffat, 2000), which is embodied in the classic formulae due to Darwin (1914), one of which is simplified here,
where Ispot is the integrated spot intensity, Vxtal is the volume of the crystal, Vcell is the volume of the crystal t is the exposure time, L is the Lorentz factor, P is the polarization factor and F is the (equivalent electrons per unit cell). Although Darwin (1914) showed that diffraction strength is inversely proportional to the square of the unit-cell volume, the unit-cell volume is, in turn,
where MW is the molecular mass of the nsymops is the number of symmetry operators in the and VM is the Matthews number (∼2.4 Å3 Da−1; Matthews, 1968). In addition, Wilson (1949) showed that the average squared is proportional to the number of atoms in the unit cell,
(Da),where fa is the average atomic of a protein atom (electrons), B is the average atomic B factor (Å2) and d is the d-spacing (resolution) of the spot of interest (Å). We will also assume that the full lifedose of the crystal is utilized, which means that the effective total accumulated exposure time (t) will be proportional to the d-spacing (d) of the spot because low-angle spots last longer (Howells et al., 2005). In addition, higher symmetry crystals require less rotation range, so for any strategy that yields complete data the total number of photons delivered to a given unique hkl index will be proportional to the number of symmetry operators (nsymops),
This effective exposure time is not the only parameter that varies with resolution. The atomic fa), the Lorentz (Darwin, 1914; Blundell & Johnson, 1976; Lipson & Langford, 2006) and polarization (Azaroff, 1955; Kahn et al., 1982; Drenth, 1999) factors all depend on the d-spacing of the spot. The average product of all these terms can be described by the empirical expression
(Excluding a scale factor, this expression is accurate to within 10% error for d-spacing between 1.5 and 4.5 Å. Combining all the above expressions we arrive at an expression for the average attainable spot intensity at a given resolution,
We now decompose the total volume of scattering matter (Vxtal) into a number of crystals (nxtals) with explicit dimensions (ℓx, ℓy and ℓz), and solve for the required number of crystals,
Assuming that some critical average spot intensity is required, we can replace the intensity term with an arbitrary proportionality constant (n0) to represent this requirement,
The n0 parameter may now be obtained empirically by plugging in the parameters from a previous experiment where the data were found to be sufficient to reach a given goal, such as a complete data set or solving a MAD structure. An accounting of the former is given in Table 2.
Acknowledgements
I would like to thank Elspeth Garman, Frank Von Delft, Ana Gonzalez and Julie Lougheed for extremely helpful discussions of this manuscript. This work was supported by grants from the National Institutes of Health (GM074929 and GM082250) and the US Department of Energy under contract No. DE-AC03-76SF00098 at Lawrence Berkeley National Laboratory.
References
Azároff, L. V. (1955). Acta Cryst. 8, 701–704. CrossRef IUCr Journals Web of Science Google Scholar
Banumathi, S., Zwart, P. H., Ramagopal, U. A., Dauter, M. & Dauter, Z. (2004). Acta Cryst. D60, 1085–1093. Web of Science CrossRef CAS IUCr Journals Google Scholar
Berman, H. M., Westbrook, J., Feng, Z., Gilliland, G., Bhat, T. N., Weissig, H., Shindyalov, I. N. & Bourne, P. E. (2000). Nucleic Acids Res. 28, 235–242. Web of Science CrossRef PubMed CAS Google Scholar
Betts, S. (2004). Part II project. Oxford University, UK. Google Scholar
Blake, C. & Phillips, D. C. (1962). Proceedings of the Symposium on the Biological Effects of Ionizing Radiation at the Molecular Level, Vienna, Austria, pp. 183–191. Google Scholar
Blundell, T. & Johnson, L. N. (1976). Protein Crystallography. London: Academic Press. Google Scholar
Borek, D., Ginell, S. L., Cymborowski, M., Minor, W. & Otwinowski, Z. (2007). J. Synchrotron Rad. 14, 24–33. Web of Science CrossRef CAS IUCr Journals Google Scholar
Bourenkov, G. P. & Popov, A. N. (2006). Acta Cryst. D62, 58–64. Web of Science CrossRef CAS IUCr Journals Google Scholar
Box, H. R. (1977). Radiation Effects: ESR and ENDOR Analysis. London: Academic Press. Google Scholar
Burmeister, W. P. (2000). Acta Cryst. D56, 328–341. Web of Science CrossRef CAS IUCr Journals Google Scholar
Carugo, O. & Carugo, K. D. (2005). Trends Biochem. Sci. 30, 213–219. Web of Science CrossRef PubMed CAS Google Scholar
Chinte, U., Shah, B., Chen, Y.-S., Pinkerton, A. A., Schall, C. A. & Hanson, B. L. (2007). Acta Cryst. D63, 486–492. Web of Science CrossRef CAS IUCr Journals Google Scholar
Cole, A. (1969). Radiat. Res. 38, 7–33. CrossRef CAS PubMed Web of Science Google Scholar
Corbett, M. C., Latimer, M. J., Poulos, T. L., Sevrioukova, I. F., Hodgson, K. O. & Hedman, B. (2007). Acta Cryst. D63, 951–960. Web of Science CrossRef CAS IUCr Journals Google Scholar
Coulibaly, F., Chiu, E., Ikeda, K., Gutmann, S., Haebel, P. W., Schulze-Briese, C., Mori, H. & Metcalf, P. (2007). Nature (London), 446, 97–101. Web of Science CrossRef PubMed CAS Google Scholar
Darwin, C. G. (1914). Philos. Mag. 27, 315. CrossRef Google Scholar
Douzou, P. (1977). Cryobiochemistry: An Introduction. New York: Academic Press. Google Scholar
Drenth, J. (1999). Principles of Protein Crystallography, p 109. New York: Springer-Verlag. Google Scholar
Dubnovitsky, A. P., Ravelli, R. B. G., Popov, A. N. & Papageorgiou, A. C. (2005). Protein Sci. 14, 1498–1507. Web of Science CrossRef PubMed CAS Google Scholar
Evans, P. (2006). Acta Cryst. D62, 72–82. Web of Science CrossRef CAS IUCr Journals Google Scholar
Facciotti, M. T., Cheung, V. S., Nguyen, D., Rouhani, S. & Glaeser, R. M. (2003). Biophys. J. 85, 451–458. Web of Science CrossRef PubMed CAS Google Scholar
Fioravanti, E., Vellieux, F. M. D., Amara, P., Madern, D. & Weik, M. (2007). J. Synchrotron Rad. 14, 84–91. Web of Science CrossRef CAS IUCr Journals Google Scholar
Fuhrmann, C. N., Kelch, B. A., Ota, N. & Agard, D. A. (2004). J. Mol. Biol. 338, 999–1013. Web of Science CrossRef PubMed CAS Google Scholar
Garman, E. (2003). Curr. Opin. Struct. Biol. 13, 545–551. Web of Science CrossRef PubMed CAS Google Scholar
Garman, E. F. & McSweeney, S. M. (2007). J. Synchrotron Rad. 14, 1–3. Web of Science CrossRef IUCr Journals Google Scholar
Garman, E. & Nave, C. (2002). J. Synchrotron Rad. 9, 327–328. Web of Science CrossRef IUCr Journals Google Scholar
Glaeser, R., Facciotti, M., Walian, P., Rouhani, S., Holton, J., MacDowell, A., Celestre, R., Cambie, D. & Padmore, H. (2000). Biophys. J. 78, 3178–3185. Web of Science CrossRef PubMed CAS Google Scholar
Glaeser, R. M. (2008). J. Struct. Biol. 163, 271–276. Web of Science CrossRef PubMed CAS Google Scholar
Gonzalez, A. & Nave, C. (1994). Acta Cryst. D50, 874–877. CrossRef CAS Web of Science IUCr Journals Google Scholar
Grabolle, M., Haumann, M., Müller, C., Liebisch, P. & Dau, H. (2006). J. Biol. Chem. 281, 4580–4588. Web of Science CrossRef PubMed CAS Google Scholar
Hanson, B. L., Harp, J. M., Kirschbaum, K., Schall, C. A., DeWitt, K., Howard, A., Pinkerton, A. A. & Bunick, G. J. (2002). J. Synchrotron Rad. 9, 375–381. Web of Science CrossRef CAS IUCr Journals Google Scholar
Helliwell, J. R., Ealick, S., Doing, P., Irving, T. & Szebenyi, M. (1993). Acta Cryst. D49, 120–128. CrossRef CAS Web of Science IUCr Journals Google Scholar
Holton, J. M. (2007). J. Synchrotron Rad. 14, 51–72. Web of Science CrossRef CAS IUCr Journals Google Scholar
Holton, J. M. (2008). Expected crystal lifetimes at synchrotron beamlines, https://bl831.als.lbl.gov/damage_rates.pdf. Google Scholar
Howell, P. L. & Smith, G. D. (1992). J. Appl. Cryst. 25, 81–86. CrossRef Web of Science IUCr Journals Google Scholar
Howells, M. R., Beetz, T., Chapman, H. N., Chi, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., Sayre, D., Shapiro, D. A. & Spence, J. C. H. (2005). J. Electron. Spectrosc. Relat. Phenom. In the press. (Preprint at https://arxiv.org/abs/physics/0502059.) Google Scholar
Hubbell, J. H. (1982). Int. J. Appl. Radiat. Isotopes, 33, 1269–1290. CrossRef CAS Web of Science Google Scholar
Hubbell, J. H. (2006). Phys. Med. Biol. 51, R245–R262. Web of Science CrossRef PubMed CAS Google Scholar
James, R. W. (1962). The Optical Principles of the Diffraction of X-rays: The Crystalline State, Vol. II. London: Bell & Hyman. Google Scholar
Kahn, R., Fourme, R., Gadet, A., Janin, J., Dumas, C. & André, D. (1982). J. Appl. Cryst. 15, 330–337. CrossRef CAS Web of Science IUCr Journals Google Scholar
Kauffmann, B., Weiss, M. S., Lamzin, V. S. & Schmidt, A. (2006). Structure, 14, 1099–1105. Web of Science CrossRef PubMed CAS Google Scholar
Kendrew, J. C., Dickerson, R. E., Strandberg, B. E., Hart, R. G., Davies, D. R., Phillips, D. C. & Shore, V. C. (1960). Nature (London), 185, 422. CrossRef PubMed Web of Science Google Scholar
Kmetko, J., Husseini, N. S., Naides, M., Kalinin, Y. & Thorne, R. E. (2006). Acta Cryst. D62, 1030–1038. Web of Science CrossRef CAS IUCr Journals Google Scholar
Kuller, A., Fleri, W., Bluhm, W. F., Smith, J. L., Westbrook, J. & Bourne, P. E. (2002). Trends Biochem. Sci. 27, 213–215. Web of Science CrossRef PubMed CAS Google Scholar
Leiros, H.-K. S., McSweeney, S. M. & Smalås, A. O. (2001). Acta Cryst. D57, 488–497. Web of Science CrossRef CAS IUCr Journals Google Scholar
Leiros, H.-K. S., Timmins, J., Ravelli, R. B. G. & McSweeney, S. M. (2006). Acta Cryst. D62, 125–132. Web of Science CrossRef CAS IUCr Journals Google Scholar
Li, J., Edwards, P. C., Burghammer, M., Villa, C. & Schertler, G. F. (2004). J. Mol. Biol. 343, 1409–1438. Web of Science CrossRef PubMed CAS Google Scholar
Lipson, H. & Langford, J. I., (2006). International Tables for Crystallography, Vol. C, 1st online ed., §6.2.4, p. 596. International Union of Crystallography. Google Scholar
MacDowell, A. A. et al. (2004). J. Synchrotron Rad. 11, 447–455. Web of Science CrossRef CAS IUCr Journals Google Scholar
Massover, W. H. (2007). J. Synchrotron Rad. 14, 116–127. Web of Science CrossRef CAS IUCr Journals Google Scholar
Matthews, B. W. (1968). J. Mol. Biol. 33, 491. CrossRef PubMed Web of Science Google Scholar
McGeehan, J., Ravelli, R. B. G., Murray, J. W., Owen, R. L., Cipriani, F., McSweeney, S., Weik, M. & Garman, E. F. (2009). J. Synchrotron Rad. 16, 163–172. Web of Science CrossRef CAS IUCr Journals Google Scholar
McMaster, W. H., Del Grande, N. K., Mallett, J. H. & Hubbell, J. H. (1969). Compilation of X-ray Cross Sections. Report UCRL-50174, Lawrence Livermore National Laboratory, CA, USA. Google Scholar
Meents, A., Wagner, A., Schneider, R., Pradervand, C., Pohl, E. & Schulze-Briese, C. (2007). Acta Cryst. D63, 302–309. Web of Science CrossRef CAS IUCr Journals Google Scholar
Meitzner, G., Gardea-Torresdey, J., Parsons, J., Scott, S. L. & Deguns, E. W. (2005). Microchem. J. 81, 61–68. Web of Science CrossRef CAS Google Scholar
Moukhametzianov, R., Burghammer, M., Edwards, P. C., Petitdemange, S., Popov, D., Fransen, M., McMullan, G., Schertler, G. F. X. & Riekel, C. (2008). Acta Cryst. D64, 158–166. Web of Science CrossRef CAS IUCr Journals Google Scholar
Murray, J. & Garman, E. (2002). J. Synchrotron Rad. 9, 347–354. Web of Science CrossRef CAS IUCr Journals Google Scholar
Murray, J. W., Garman, E. F. & Ravelli, R. B. G. (2004). J. Appl. Cryst. 37, 513–522. Web of Science CrossRef CAS IUCr Journals Google Scholar
Murray, J. W., Rudiño-Piñera, E., Owen, R. L., Grininger, M., Ravelli, R. B. G. & Garman, E. F. (2005). J. Synchrotron Rad. 12, 268–275. Web of Science CrossRef CAS IUCr Journals Google Scholar
Myers, L. S. Jr (1973). In The Radiation Chemistry of Macromolecules, Vol. II, edited by M. Dole. New York: Academic Press. Google Scholar
Nanao, M. H., Sheldrick, G. M. & Ravelli, R. B. G. (2005). Acta Cryst. D61, 1227–1237. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nave, C. & Garman, E. F. (2005). J. Synchrotron Rad. 12, 257–260. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nave, C. & Hill, M. A. (2005). J. Synchrotron Rad. 12, 299–303. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nelson, R., Sawaya, M. R., Balbirnie, M., Madsen, A. Ã., Riekel, C., Grothe, R. & Eisenberg, D. (2005). Nature (London), 435, 773–778. Web of Science CrossRef PubMed CAS Google Scholar
Newton, A. (1963). Radiation Effects on Organic Materials, edited by R. O. Bolt and J. G. Carroll. New York: Academic Press. Google Scholar
Nukaga, M., Mayama, K., Hujer, A. M., Bonomo, R. A. & Knox, J. R. (2003). J. Mol. Biol. 328, 289–301. Web of Science CrossRef PubMed CAS Google Scholar
Oliéric, V., Ennifar, E., Meents, A., Fleurant, M., Besnard, C., Pattison, P., Schiltz, M., Schulze-Briese, C. & Dumas, P. (2007). Acta Cryst. D63, 759–768. Web of Science CrossRef IUCr Journals Google Scholar
O'Neill, P., Stevens, D. L. & Garman, E. (2002). J. Synchrotron Rad. 9, 329–332. Web of Science CrossRef CAS IUCr Journals Google Scholar
Owen, R. L., Holton, J. M., Schulze-Briese, C. & Garman, E. F. (2009). J. Synchrotron Rad. 16, 143–151. Web of Science CrossRef CAS IUCr Journals Google Scholar
Owen, R. L., Pritchard, M. & Garman, E. (2004). J. Appl. Cryst. 37, 1000–1003. Web of Science CrossRef CAS IUCr Journals Google Scholar
Owen, R. L., Rudino-Pinera, E. & Garman, E. F. (2006). Proc. Natl Acad. Sci. 103, 4912–4917. Web of Science CrossRef PubMed CAS Google Scholar
Paithankar, K. S., Owen, R. L. & Garman, E. F. (2009). J. Synchrotron Rad. 16, 152–162. Web of Science CrossRef CAS IUCr Journals Google Scholar
Petrik, N. G. & Kimmel, G. A. (2003). Phys. Rev. Lett. 90, 269–270. Web of Science CrossRef Google Scholar
Petrik, N. G. & Kimmel, G. A. (2004). J. Chem. Phys. 121, 3736–3744. Web of Science CrossRef PubMed CAS Google Scholar
Polentarutti, M., Glazer, R. & Djinović Carugo, K. (2004). J. Appl. Cryst. 37, 319–324. CrossRef CAS IUCr Journals Google Scholar
Ravelli, R. B. G. & Garman, E. (2006). Curr. Opin. Struct. Biol. 16, 624–629. Web of Science CrossRef PubMed CAS Google Scholar
Ravelli, R. B. G., Leiros, H. K. S., Pan, B. C., Caffrey, M. & McSweeney, S. (2003). Structure, 11, 217–224. Web of Science CrossRef PubMed CAS Google Scholar
Ravelli, R. B. G. & McSweeney, S. M. (2000). Structure, 8, 315–328. Web of Science CrossRef PubMed CAS Google Scholar
Ravelli, R. B. G., Nanao, M. H., Lovering, A., White, S. & McSweeney, S. (2005). J. Synchrotron Rad. 12, 276–284. Web of Science CrossRef CAS IUCr Journals Google Scholar
Roberts, B. R., Wood, Z. A., Jonsson, T. J., Poole, L. B. & Karplus, P. A. (2005). Protein Sci. 14, 2414–2420. Web of Science CrossRef PubMed CAS Google Scholar
Sawaya, M. R., Sambashivan, S., Nelson, R., Ivanova, M. I., Sievers, S. A., Apostol, M. I., Thompson, M. J., Balbirnie, M., Wiltzius, J. J., McFarlane, H. T., Madsen, A. Ø., Riekel, C. & Eisenberg, D. (2007). Nature (London), 447, 453–457. Web of Science CrossRef PubMed CAS Google Scholar
Schiltz, M. & Bricogne, G. (2007). J. Synchrotron Rad. 14, 34–42. Web of Science CrossRef CAS IUCr Journals Google Scholar
Schulze-Briese, C., Wagner, A., Tomizaki, T. & Oetiker, M. (2005). J. Synchrotron Rad. 12, 261–267. Web of Science CrossRef CAS IUCr Journals Google Scholar
Schuwirth, B. S., Borovinskaya, M. A., Hau, C. W., Zhang, W., Vila-Sanjurjo, A., Holton, J. M. & Cate, J. H. (2005). Science, 310, 827–834. Web of Science CrossRef PubMed CAS Google Scholar
Seltzer, S. M. (1993). Radiat. Res. 136, 147. CrossRef PubMed Web of Science Google Scholar
Sliz, P., Harrison, S. & Rosenbaum, G. (2003). Structure, 11, 13–19. Web of Science CrossRef PubMed CAS Google Scholar
Snell, E. H., Bellamy, H. D., Rosenbaum, G. & van der Woerd, M. J. (2007). J. Synchrotron Rad. 14, 109–115. Web of Science CrossRef CAS IUCr Journals Google Scholar
Southworth-Davies, R. J. & Garman, E. F. (2007). J. Synchrotron Rad. 14, 73–83. Web of Science CrossRef CAS IUCr Journals Google Scholar
Southworth-Davies, R. J., Medina, M. A., Carmichael, I. & Garman, E. F. (2007). Structure, 15, 1531–1541. Web of Science CrossRef PubMed CAS Google Scholar
Standfuss, J., Xie, G., Edwards, P. C., Burghammer, M., Oprian, D. D. & Schertler, G. F. (2007). J. Mol. Biol. 372, 1179–1188. Web of Science CrossRef PubMed CAS Google Scholar
Teng, T. & Moffat, K. (2000). J. Synchrotron Rad. 7, 313–317. Web of Science CrossRef CAS IUCr Journals Google Scholar
Teng, T.-Y. & Moffat, K. (2002). J. Synchrotron Rad. 9, 198–201. Web of Science CrossRef CAS IUCr Journals Google Scholar
Weik, M., Bergès, J., Raves, M. L., Gros, P., McSweeney, S., Silman, I., Sussman, J. L., Houée-Levin, C. & Ravelli, R. B. G. (2002). J. Synchrotron Rad. 9, 342–346. Web of Science CrossRef CAS IUCr Journals Google Scholar
Weik, M., Ravelli, R. B. G., Kryger, G., McSweeney, S., Raves, M. L., Harel, M., Gros, P., Silman, I., Kroon, J. & Sussman, J. L. (2000). Proc. Natl. Acad. Sci. USA, 97, 623–628. Web of Science CrossRef PubMed CAS Google Scholar
Weik, M., Ravelli, R. B. G., Silman, I., Sussman, J. L., Gros, P. & Kroon, J. (2001). Protein Sci. 10, 1953–1961. Web of Science CrossRef PubMed CAS Google Scholar
Wilson, A. J. C. (1949). Acta Cryst. 2, 318–321. CrossRef IUCr Journals Web of Science Google Scholar
Woolfson, M. M. (1970). An Introduction to X-ray Crystallography, 2nd ed. Cambridge University Press. Google Scholar
Yano, J., Kern, J., Irrgang, K. D., Latimer, M. J., Bergmann, U., Glatzel, P., Pushkar, Y., Biesiadka, J., Loll, B., Sauer, K., Messinger, J., Zouni, A. & Yachandra, V. K. (2005). Proc. Natl. Acad. Sci. USA, 102, 12047–12052. Web of Science CrossRef PubMed CAS Google Scholar
Zagórsky, Z. P. (1999). Rad. Phys. Chem. 56, 559–565. Google Scholar
Zwart, P. H., Banumathi, S., Dauter, M. & Dauter, Z. (2004). Acta Cryst. D60, 1958–1963. Web of Science CrossRef CAS IUCr Journals Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.