short communications
Utilizing broadband X-rays in a Bragg coherent X-ray diffraction imaging experiment
aMaterials Science Division, Argonne National Laboratory, Argonne, IL 60439, USA, and bX-ray Science Division, Argonne National Laboratory, Argonne, IL 60439, USA
*Correspondence e-mail: shrus@anl.gov
A method is presented to simplify Bragg coherent X-ray diffraction imaging studies of complex heterogeneous crystalline materials with a two-stage screening/imaging process that utilizes polychromatic and monochromatic coherent X-rays and is compatible with in situ sample environments. Coherent white-beam diffraction is used to identify an individual crystal particle or grain that displays desired properties within a larger population. A three-dimensional reciprocal-space map suitable for diffraction imaging is then measured for the Bragg peak of interest using a monochromatic beam energy scan that requires no sample motion, thus simplifying in situ chamber design. This approach was demonstrated with Au nanoparticles and will enable, for example, individual grains in a polycrystalline material of specific orientation to be selected, then imaged in three dimensions while under load.
Keywords: coherent X-ray diffraction imaging; polychromatic X-ray diffraction; materials characterization.
1. Introduction
The performance of modern materials across a broad spectrum of applications relies on properties, interactions and heterogeneity at nanometer to micrometer length scales. Thus, characterizing the local structure in materials at these length scales under realistic conditions is critical for optimizing performance. Bragg coherent diffraction imaging (BCDI) shows great potential in this area, and has recently been used to nondestructively image the internal strain in nanoscale crystals under in situ conditions (Cha et al., 2013; Ulvestad et al., 2015; Clark et al., 2015). However, as currently implemented, BCDI utilizes a single-wavelength monochromatic X-ray beam. As a result, the sample must be rotated in order to measure a data set that yields a three-dimensional (3D) image, limiting the design of in situ experiments. Furthermore, a monochromatic beam accesses a limited volume of such that the behavior of multiple particles in an ensemble is difficult to simultaneously survey, for example, to identify a single grain in a volume that responds most strongly to an applied impulse.
Here, we address both of these challenges by introducing a two-stage approach to BCDI that utilizes the broadband coherent X-ray spectrum of a third-generation synchrotron source. We demonstrate that a coherent white beam can be used to survey a broad swath of et al., 2011), thus allowing the sample to remain stationary while obtaining data needed for 3D imaging. Such a two-stage screening/imaging capability can be a powerful way to study individual crystallites in an ensemble when the exact orientation and location of the most responsive subset of crystals is not known a priori (Lind et al., 2014; Ice et al., 2011). We demonstrated this concept by identifying an individual gold nanoparticle from a population of textured orientations using white-beam coherent diffraction, then measuring its 3D Bragg coherent diffraction pattern with a monochromatic beam energy scan without moving the sample.
in order to identify individual crystallites of interest. Upon identifying a crystalline grain or particle for study, a monochromator is translated into the beam and used to measure a volume of by scanning energy (Cornelius2. Experiment
The measurement was performed at the Sector 34-ID-E beamline at the Advanced Photon Source. This beamline is equipped with a double-crystal monochromator that can be translated into and out of the incoming X-ray beam, thus allowing collimated monochromatic or polychromatic (white beam) X-rays to illuminate the same area of the sample (see Fig. 1) (Ice et al., 2000). The Si (111) monochromator was positioned 5 m upstream of the sample and is capable of scanning energy in increments as small as 1 eV. The incoming X-ray source size was defined in the horizontal direction by slits 30 m upstream of the sample (0.1 mm wide) and in the vertical direction by the size of the beam from the undulator (30 µm), 60 m from the sample. With such a source size, the horizontal (H) and vertical (V) transverse coherence lengths (without focusing) were determined to be 65 µm and 35 µm, respectively, via fringe visibility measurements from grating scattering. The size of the beam at the sample was determined by secondary slits set to 50 µm (H) × 100 µm (V) positioned 0.85 m from the sample. The energy spectrum of the undulator used in this study is shown in Fig. 2, set to peak at 9.21 keV with ∼250 eV FWHM (no taper).
A sample consisting of Au nanoparticles on a [001]-surface-normal-oriented Si substrate was used in this study. The Au nanoparticles were approximately spherical, ∼200–400 nm in diameter. They were oriented such that [111]Au||[001]Si, with a textured distribution of orientations (∼0.4° FWHM). The vertical diffraction geometry (Fig. 1) was such that the 111 Au Bragg condition was satisfied at an X-ray energy of 9.21 keV. Thus, the angle of the sample relative to the incident beam (θ) was set to 16.2° and the center of the area detector (Pixirad-1 with CdTe sensor) was positioned at a 2θ angle of 33.2°. The sample-to-detector distance was 860 mm, and the detector had hexagonal pixels of width 60 µm.
3. Results and discussion
Fig. 3 shows a measured coherent diffraction pattern containing 111 Bragg peaks from multiple Au particles illuminated with an unfocused white beam (spectrum shown in Fig. 2). The pattern was measured with the sample tilted in χ by 0.3° from the surface normal of the substrate, near the tail of the textured particle orientation distribution. Because of this tilting in χ, the number of Au Bragg peaks in the detector increases from left to right, towards the peak of the orientation distribution near χ = 0°. In the 2θ detector dimension, Au Bragg peaks are visible from particles with different orientations along θ. [Particles with different lattice parameters would also appear at different 2θ values, but here the Au crystals were determined to have a uniform (111) lattice spacing.] Multiple crystals with different orientations along θ are visible because of the broad bandwidth of the incoming white beam. Particles with Bragg peaks in the bottom half of the detector (lower 2θ) diffract higher-energy photons from the spectrum, and high 2θ peaks consist of lower-energy photons. Particles that diffract into the central 2θ range of the detector diffract photons near the peak of the undulator spectrum at 9.21 keV.
We note that coherent diffraction fringes are seen decorating the Bragg peaks from individual Au nanoparticles due to the high degree of transverse coherence of the white beam. These fringes are a projection of the 3D coherent Bragg diffraction pattern onto the detector plane over a range of incident beam energies [a concept explored in simulation by Ice et al. (2009)]. This was confirmed by translating the monochromator into the beam and performing an energy scan over the range indicated in red in Fig. 2 with 2 eV steps. Fig. 4 shows the white-beam Bragg diffraction pattern in the center of the detector (a) compared with a summed image of the monochromatic beam energy scan (b), and the two are very similar. Small differences arise due to slight differences in the position of the monochromatic and white beams. Differences in the longitudinal coherence of the diffracted X-ray beam likely contributes to small differences in the expected fringe visibility of the two patterns, but the fringe visibility of the two patterns shown here are indistinguishable within noise.
The primary utility of the coherent monochromatic beam energy scan is to enable the fringes of this Bragg peak to be resolved in three dimensions. As shown in Fig. 5(a), changing the wavelength λ of the incoming X-rays changes the length of the reciprocal-space scattering vector q = kf-ki (where = = ). By stepping energy in sufficiently fine increments (Cornelius et al., 2011), the volume of reciprocal surrounding a Bragg peak can be measured [gray parallelogram in Fig. 5(a)]. In order to represent the 3D scattering information measured in this experiment, we calculated the value of q corresponding to the center of each hexagonal pixel in the detector at each energy step. Using these q-space coordinates, the recorded intensity was interpolated onto a regular q-space grid, along the principle axes qx,qy,qz indicated in Fig. 5(a). Two interpolated orthogonal cuts through the reciprocal-space volume surrounding the Au 111 Bragg peak are shown in Figs. 5(b) and 5(c). These cuts show the characteristic fringes associated with a gold nanoparticle, indicating a faceted flattened circular shape approximately 360 nm in diameter and 150 nm in height. Such a 3D coherent diffraction pattern with well defined fringes is well suited for 3D imaging with BCDI, and can be measured without changing the position of the sample.
We also note that the time resolution of the 3D Bragg peak measurement can potentially be improved by replacing the monochromatic beam energy scan with a system of multi-angle semi-transparent analyzer crystals acting to disperse the Bragg-diffracted white beam in energy and angle. This concept is presented in Fig. 6 and is based on introducing a series of thin X-ray-transparent single-crystal membrane analyzer crystals into the diffracted white beam from the sample. The analyzers are positioned at slightly different angles relative to the white-beam Bragg peak such that each analyzer diffracts photons of unique energy and exit angle into an area detector. With an appropriate transform, the measured intensity pattern can then be translated to regular qx,qy,qz coordinates, as in Fig. 5. If realised, such a capability would enable 3D reciprocal-space maps suitable for BCDI to be collected with a small number of rapid white-beam exposures to the sample. The gains in time resolution would scale with the number of transparent analyzers introduced in the diffracted beam. For example, if five analyzer membranes are introduced separated by small angles (∼0.1°), then five `cuts' about the Bragg peak can be accessed at once. Thus, in this case, one-fifth of the number of exposures are theoretically needed in an analyzer angle scan (θana) as compared with a monochromatic beam sample angle scan (θsam). Preliminary experiments performed with 2 µm-thick Si crystal membranes suggest that such a five-analyzer arrangement may be feasible, and the concept can conceivably be extended to incorporate more analyzers.
The capability outlined here (i.e. utilizing a coherent white beam to survey a population of differently aligned crystallites, identifying one for 3D imaging, and employing a fixed-sample-position energy scan with a monochromatic beam) potentially increases the scope of in situ 3D imaging studies feasible with BCDI. Firstly, in systems with complex heterogeneous local structure, it is often difficult to predict which local volumes will respond to a given environmental change (i.e. applied stress, voltage, chemical environment). Thus simultaneously screening a larger population of particles with a white beam is advantageous for quickly identifying a maximally responsive crystal or grain for 3D BCDI imaging. Secondly, by utilizing an energy scan to record the 3D volume surrounding the Bragg peak of the selected crystallite (as compared with a sample angle scan), the sample itself remains stationary during the measurement. This allows for greater latitude in designing complex environmental chambers for in situ studies where sample motion is cumbersome (Cornelius et al., 2012).
Acknowledgements
This work, including use of the Advanced Photon Source, was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357. PHF and SOH were supported by US DOE, Basic Energy Sciences, Materials Sciences and Engineering Division.
References
Cha, W., Jeong, N. C., Song, S., Park, H., Thanh Pham, T. C., Harder, R., Lim, B., Xiong, G., Ahn, D., McNulty, I., Kim, J., Yoon, K. B., Robinson, I. K. & Kim, H. (2013). Nat. Mater. 12, 729–734. CrossRef CAS PubMed Google Scholar
Clark, J. N., Ihli, J., Schenk, A. S., Kim, Y.-Y., Kulak, A. N., Campbell, J. M., Nisbet, G., Meldrum, F. C. & Robinson, I. K. (2015). Nat. Mater. 14, 780–784. CrossRef CAS PubMed Google Scholar
Cornelius, T. W., Carbone, D., Jacques, V. L. R., Schülli, T. U. & Metzger, T. H. (2011). J. Synchrotron Rad. 18, 413–417. Web of Science CrossRef CAS IUCr Journals Google Scholar
Cornelius, T. W., Davydok, A., Jacques, V. L. R., Grifone, R., Schülli, T., Richard, M.-I., Beutier, G., Verdier, M., Metzger, T. H., Pietsch, U. & Thomas, O. (2012). J. Synchrotron Rad. 19, 688–694. Web of Science CrossRef CAS IUCr Journals Google Scholar
Ice, G. E., Budai, J. D. & Pang, J. W. L. (2011). Science, 334, 1234–1239. Web of Science CrossRef CAS PubMed Google Scholar
Ice, G. E., Chung, J.-S., Lowe, W., Williams, E. & Edelman, J. (2000). Rev. Sci. Instrum. 71, 2001–2006. Web of Science CrossRef CAS Google Scholar
Ice, G. E., Pang, J. W. L., Larson, B. C., Budai, J. D. Z. T. J., Tischler, J. Z., Choi, J., Liu, W., Liu, C., Assoufid, L., Shu, D. & Khounsary, A. (2009). Mater. Sci. Eng. A, 524, 3–9. CrossRef Google Scholar
Lind, J., Li, S. F., Pokharel, R., Lienert, U., Rollett, A. D. & Suter, R. M. (2014). Acta Mater. 76, 213–220. Web of Science CrossRef CAS Google Scholar
Ulvestad, A., Singer, A., Clark, J. N., Cho, H. M., Kim, J. W., Harder, R., Maser, J., Meng, Y. S. & Shpyrko, O. G. (2015). Science, 348, 1344–1347. CrossRef CAS PubMed Google Scholar
This article is published by the International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.