research papers\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Determination of copper nanoparticle size distributions with total reflection X-ray fluorescence spectroscopy

crossmark logo

aStanford Synchrotron Radiation Laboratory, 2575 Sand Hill Road, Stanford, CA 94025, USA, and bDepartment of Applied Chemistry, Waseda University, Shinjuku, Tokyo 169-8555, Japan
*Correspondence e-mail: pianetta@slac.stanford.edu

Edited by V. Favre-Nicolin, CEA and Université Joseph Fourier, France (Received 18 July 2016; accepted 3 October 2016)

Total reflection X-ray fluorescence (TXRF) analysis is extensively used by the semiconductor industry for measuring trace metal contamination on silicon surfaces. In addition to determining the quantity of impurities on a surface, TXRF can reveal information about the vertical distribution of contaminants by measuring the fluorescence signal as a function of the angle of incidence. In this study, two samples were intentionally contaminated with copper in non-de­oxygenated and de­oxygenated ultrapure water (UPW) resulting in impurity profiles that were either atomically dispersed in a thin film or particle-like, respectively. The concentration profile of the samples immersed into de­oxygenated UPW was calculated using a theoretical concentration profile representative of particles, yielding a mean particle height of 16.1 nm. However, the resulting theoretical profile suggested that a distribution of particle heights exists on the surface. The fit of the angular distribution data was further refined by minimizing the residual error of a least-squares fit employing a model with a Gaussian distribution of particle heights about the mean height. The presence of a height distribution was also confirmed with atomic force microscopy measurements.

1. Introduction

Contamination analysis of silicon wafer surfaces with total reflection X-ray fluorescence (TXRF) has been critical for understanding and improving silicon processing technologies (Pahlke, 2003[Pahlke, S. (2003). At. Spectrosc. 58, 2025-2038.]; Hockett, 1994[Hockett, R. S. (1994). MRS Online Proc. Libr. Arch. 354, 377.]; Pahlke et al., 2001[Pahlke, S., Fabry, L., Kotz, L., Mantler, C. & Ehmann, T. (2001). At. Spectrosc. 56, 2261-2274.]; Pianetta et al., 1995[Pianetta, P., Takaura, N., Brennan, S., Tompkins, W., Laderman, S. S., Fischer-Colbrie, A., Shimazaki, A., Miyazaki, K., Madden, M., Wherry, D. C. & Kortright, J. B. (1995). Rev. Sci. Instrum. 66, 1293-1297.]). With the continuing drive to increase device density, the acceptable levels of surface contamination have been decreasing requiring transition metal impurity levels on silicon surfaces to be in the low 109 atoms cm−2 range (Kern, 2008[Kern, W. (2008). Handbook of Silicon Wafer Cleaning Technology, pp. 3-92. Amsterdam: Elsevier.]; Hoefflinger, 2011[Hoefflinger, B. (2011). Editor. Chips 2020: A Guide to the Future of Nanoelectronics, pp. 161-174. Berlin, Heidelberg: Springer.]). With TXRF, wafer surfaces can be measured non-destructively and detection limits of the order of 5 × 109 atoms cm−2 for various transition metals have been routinely achieved with conventional X-ray sources (Klockenkämper & von Bohlen, 2014[Klockenkämper, R. & von Bohlen, A. (2014). Total-Reflection X-ray Fluorescence Analysis and Related Methods. New York: Wiley.]). Even better sensitivities can be achieved with the use of vapor phase decomposition (VPD) techniques (Yamagami et al., 1999[Yamagami, M., Nonoguchi, M., Yamada, T., Shoji, T., Utaka, T., Nomura, S., Taniguchi, K., Wakita, H. & Ikeda, S. (1999). X-ray Spectrom. 28, 451-455.]). Moreover, by using synchrotron radiation sources, these detections limits have been greatly enhanced to levels of 8 × 107 atoms cm−2 due to the high flux density (Pianetta et al., 2000[Pianetta, P., Baur, K., Singh, A., Brennan, S., Kerner, J., Werho, D. & Wang, J. (2000). Thin Solid Films, 373, 222-226.]).

In addition to measuring surface concentrations, geometrical information on the vertical distribution of contaminants can be determined by using the TXRF technique in the so-called grazing-incidence X-ray fluorescence (GIXRF) mode, where the fluorescence signal of an impurity is monitored as a function of the angle of incidence (Klockenkämper & von Bohlen, 2014[Klockenkämper, R. & von Bohlen, A. (2014). Total-Reflection X-ray Fluorescence Analysis and Related Methods. New York: Wiley.]; Meirer et al., 2010[Meirer, F., Singh, A., Pianetta, P., Pepponi, G., Meirer, F., Streli, C. & Homma, T. (2010). Trends Anal. Chem. 29, 479-496.]). For example, it is possible to ascertain whether contaminants are atomically dispersed throughout the bulk, incorporated in a thin film layer or exist as particles above the surface. This is the result of a standing wave pattern that is formed directly above the silicon surface due to interference between the incoming X-ray beam and the totally reflected beam. The periodicity of these standing waves, as well as the penetration depth of the X-rays, can be modulated by changing the angle of incidence. Therefore, the fluorescence intensity as a function of angle will strongly depend on the vertical distribution of the element of interest.

In fact, quantitative analysis to determine the vertical concentration profile of an impurity can be carried out through the use of least-squares fitting provided an accurate model for the concentration profile is used (Schwenke et al., 1997[Schwenke, H., Knoth, J., Fabry, L., Pahlke, S., Scholz, R. & Frey, L. (1997). J. Electrochem. Soc. 144, 3979-3983.]). Such studies have proven useful in conducting depth profiles of ions implanted in Si and Ge (Hönicke et al., 2012[Hönicke, P., Kayser, Y., Beckhoff, B., Müller, M., Dousse, J.-C., Hoszowska, J. & Nowak, S. H. (2012). J. Anal. At. Spectrom. 27, 1432-1438.]; Kayser et al., 2015[Kayser, Y., Hönicke, P., Banaś, D., Dousse, J.-C., Hoszowska, J., Jagodziński, P., Kubala-Kukuś, A., Nowak, S. H. & Pajek, M. (2015). J. Anal. At. Spectrom. 30, 1086-1099.]), and also in characterization of surface particles (Nowak et al., 2013[Nowak, S. H., Reinhardt, F., Beckhoff, B., Dousse, J.-C. & Szlachetko, J. (2013). J. Anal. At. Spectrom. 28, 689-696.]; Reinhardt et al., 2012[Reinhardt, F., Beckhoff, B., Pollakowski, B., Kolbe, M., Osán, J., Török, S., Schoengen, M., Nowak, S., Dousse, J.-C., Bresch, H., Seeger, S. & Waldschläger, U. (2012). Proceedings of the European Conference on X-ray Spectrometry (EXRS 2012), 18-22 June 2012, Vienna, Austria.]). In this study, a similar analysis was carried out in order to determine the mean particle height of Cu particles deposited in de­oxygenated ultrapure water (UPW). In addition, through the use of atomic force microscopy (AFM) measurements, it was found that a height distribution of particles existed. By refining the model describing the Cu concentration profile to account for the particle height distribution, it was possible to improve the fit and extract additional parameters, such as the width of the distribution, from the GIXRF measurements.

2. Experimental

Cleaved 20 mm × 10 mm Si wafers were cleaned using a 4:1 sulfuric acid/hydrogen peroxide mixture (H2SO4 = 96 vol.%; H2O2 = 30 vol.%) for 10 min and then rinsed in de­oxy­genated UPW. Then they were dipped for 1 min into a 0.5% HF solution resulting in a clean hydrogen-terminated surface. The influence of oxygen in the UPW was studied by comparing the results from solutions made using standard UPW containing 3–10 p.p.m. of dissolved O2 with those made using de­oxy­genated UPW solutions, prepared by sparging with argon, in which the dissolved O2 content was reduced to approximately 0.3 p.p.m. The O2 level in standard UPW was estimated from separate XPS measurements of the oxidation rate of a Si wafer when placed in UPW (Kasnavi et al., 2001[Kasnavi, R., Sun, Y., Mount, G., Pianetta, P., Griffin, P. B. & Plummer, J. D. (2001). Electrochem. Solid-State Lett. 4, G1-G3.]) and then compared with literature values of oxidation rate versus UPW O2 concentration (Yagi et al., 1992[Yagi, Y., Imaoka, T., Ksama, Y. & Ohmi, T. (1992). IEEE Trans. Semicond. Manuf. 5, 121-127.]; Li et al., 2005[Li, F., Balazs, M. K. & Anderson, S. (2005). J. Electrochem. Soc. 152, G669.]). The O2 level in the de­oxy­genated UPW was estimated from literature values of studies using a similar sparging procedure (Li et al., 2005[Li, F., Balazs, M. K. & Anderson, S. (2005). J. Electrochem. Soc. 152, G669.]; Butler et al., 1994[Butler, I. B., Schoonen, M. A. A. & Rickard, D. T. (1994). Talanta, 41, 211-215.]). Copper in a 2% nitric acid matrix was then introduced at concentration levels of 100 p.p.b. and the Si surfaces were contaminated by immersing the hydrogen-terminated silicon samples into these solutions for 300 s.

The surface concentration of the copper contaminants was analyzed using SR-TXRF on the 6-2 beamline at the Stanford Synchrotron Radiation Laboratory (SSRL) at an incident beam energy of 11.2 keV. In order to determine if the Cu was deposited as a thin surface layer or as particles on the Si surfaces, the Cu fluorescence signal was measured as a function of incident beam angle from 0.01 to 0.3°. In the sample where the copper was as nanoparticles, AFM measurements were also taken to confirm the particle size distribution. Further details on the sample preparation and experimental setup are discussed elsewhere (Singh et al., 2004[Singh, A., Luening, K., Brennan, S., Homma, T., Kubo, N. & Pianetta, P. (2004). AIP Conf. Proc. 705, 1086-1089.]; Pianetta et al., 2000[Pianetta, P., Baur, K., Singh, A., Brennan, S., Kerner, J., Werho, D. & Wang, J. (2000). Thin Solid Films, 373, 222-226.]).

3. Results and discussion

Fig. 1[link] shows the Cu fluorescence intensity as a function of the angle of incidence for samples immersed in 100 p.p.b. Cu-contaminated UPW solutions. As can be seen, the sample prepared in non-de­oxy­genated UPW has a profile indicative of atomically dispersed Cu near the surface, where the maximum in fluorescence intensity occurs at the critical angle of 0.16°. On the other hand, the sample immersed in de­oxy­genated UPW has a fluorescence maximum at 0.1°, suggesting that Cu particles are present on the surface.

[Figure 1]
Figure 1
Fluorescence intensity versus angle of incidence for samples immersed in deoxy­genated and non-de­oxy­genated UPW solutions containing 100 p.p.b. Cu. The critical angle for silicon is at 0.16°. A least-squares fit using a specific concentration profile yielded a particle height of 16.1 nm. Additional calculations for particles of height 15.6 and 16.6 nm are shown. Reproduced with permission from Singh (2004[Singh, A. (2004). PhD thesis, Stanford University, USA.]).

For the samples immersed in de­oxy­genated UPW, a model depicting the vertical concentration profile is shown in Fig. 2[link]. Here Cu particles grow as spherical caps extending beneath a thin oxide layer terminating at the silicon surface. Additional atomic Cu is incorporated into the native oxide that readily grows in de­oxy­genated UPW. Above the oxide surface, Cu only exists as metallic particles. In this region, the Cu concentration is determined by the mean height and the mean contact angle of the Cu particles. Therefore, a total of four parameters specify the concentration profile: (1) the height of the oxide, (2) the ratio between Cu surface concentration in the particle just above the oxide surface and the Cu surface concentration in the oxide layer, (3) the particle height and (4) the contact angle of the particle. In the oxide the amount of atomically dispersed Cu is much higher than the metallic Cu from the particles that terminate at the silicon surface, and, consequently, the concentration of Cu in the oxide can be assumed to be constant and independent of height. Mathematically, the concentration profile used is expressed as shown:

[\matrix{ {X}_{\rm Cu}(z) = 1\hfill & {\rm for} \,\, 0 \le z \le {h_{\rm oxide}},\hfill \cr {X}_{\rm Cu}(z) = \kappa\,{A}_{\rm cap} (\theta,R,z)/{V}_{\rm cap}(\theta, R) \hfill & {\rm for}\,\, z \,\gt \,{h_{\rm oxide}},\hfill }]

where XCu is the relative copper concentration, z is the height above the silicon/oxide interface, hoxide is the height of the oxide layer, κ is the ratio of the quantity of copper in the particle and the quantity of copper in the oxide, Acap is the cross-sectional area of the Cu particle, Vcap is the particle volume, θ is the contact angle and R is the radius of the spherical cap.

[Figure 2]
Figure 2
Model for the concentration profile used in the least-squares fits. The stitched line (– – –) shows the concentration profile, c(z), and the dashed line (-----) shows the corresponding intensity profile, l(z).

For reference, a schematic of the standing wave intensity profile is also shown in Fig. 2[link]; however, the overall profile changes with the angle because the frequency of the standing waves that form above the surface and the penetration depth of the X-ray into the sample both increase with the angle. The relative fluorescence signal at a specific angle can be simulated by multiplying the concentration profile with the intensity profile and integrating this product over the full spatial range of the copper. A least-squares fit of the Cu GIXRF intensity profile was then performed for the sample immersed in de­oxy­genated UPW.

For the sample contaminated in de­oxy­genated UPW the results of the least-squares fit indicate the presence of nanoparticles with a mean height of 16.1 nm, a contact angle of 59° and a concentration ratio of 0.027; the oxide thickness was found to be 0.52 nm. Additional model calculations assuming 15.6 and 16.6 nm particles are also shown in Fig. 1[link] to demonstrate the precision of this technique. As can be seen, the 16.6 nm fit shows better agreement with the data at angles below 0.09°, whereas the 15.6 nm fit better corresponds to the data at higher angles above 0.11°. From these additional results, it can be inferred that a range of particles with differing sizes exist on the surface, because larger (smaller) particles would exhibit greater fluorescence intensity at smaller (larger) angles.

In order to confirm that a range of particle sizes does exist, AFM measurements were conducted on the sample that was immersed in de­oxy­genated UPW (AFM images can be found in the supporting information). From these measurements, it was possible to extract a particle height distribution, which is shown in Fig. 3[link]. As can be seen, a range of particle heights exists in a Gaussian-like distribution that is skewed towards higher particles. From this distribution, the mean particle height was determined to be 16.6 nm, which was approximately 0.5 nm greater than the value extracted from the least-squares fit conducted on the fluorescence signal data shown in Fig. 1[link].

[Figure 3]
Figure 3
Particle size distribution of a sample immersed in de­oxy­genated UPW for 5 min containing 100 p.p.b. Cu as measured using AFM. The scan area of the sample was 20 µm × 20 µm. As can be seen the mean particle height of 16.6 nm agrees well with fits performed on fluorescence signal versus angle measurements.

In Fig. 4[link], the measured Cu fluorescence intensity is plotted as a function of angle for the sample immersed in 100 p.p.b. Cu-contaminated de­oxy­genated UPW solutions along with the same least-squares fit that was shown in Fig. 1[link]. Additionally, the theoretical fluorescence curve using the particle height distribution shown in Fig. 3[link] was also plotted. In order to perform this calculation, the concentration profile was calculated by taking a weighted average of the distribution of the different particle heights as obtained from the AFM measurements. As can be seen, several noticeable differences between the theoretical fluorescence using the distribution of particle height and the original least-squares fit using a single particle size are apparent. Firstly, the figure shows that a better fit to the data is achieved at lower angles when using the distribution of particle sizes. As larger particles have a maximum in fluorescence intensity at smaller angles, it is expected that the theoretical fluorescence calculated when using a distribution of particles is greater at small angles. Secondly, it can also be seen that a greater amount of fluorescence is predicted at large angles when the distribution of particles is used. In this case, the smaller particles in the distribution contribute to the predicted fluorescence intensity at large angles. Finally, it can be seen that the maximum in fluorescence intensity when using the distribution of particles is less when using particles of the same size. With regards to the data, neither profile exhibits a better fit in the region near the fluorescence intensity maximum, as calculations using the distribution of particles are too low, whereas the fit using particles of the same height is too high. However, when examining both profiles over the full range of data, it is clear that the calculation using the distribution of particles more accurately corresponds to the data.

[Figure 4]
Figure 4
Using the distribution of particle sizes shown in Fig. 3[link], the theoretical fluorescence signal versus incident beam angle was plotted. Compared with the 16.1 nm fit shown in Fig. 1[link], the profile is broader and overall is a better fit.

In order to demonstrate that GIXRF itself is a technique sensitive enough to also provide information on the particle distribution, another least-squares fit was conducted on the experimental data. In this fit, a Gaussian particle height distribution about a mean of 16.1 nm was used to describe the concentration profile. In Fig. 5[link], the residual error of this calculation is shown as a function of the full-width at half maximum (FWHM) of the particle height distribution. From this plot, it can be seen that the quality of the fit improves by assuming that a distribution of particle heights exist. Assuming that all particles have the same height, as was done for the fit shown in Fig. 1[link], the residual error is approximately 2.60 as can be seen in Fig. 5[link]. However, with increasing FWHM, the residual drops to lower values until reaching a minimum value when FWHM is 2.8 nm. This value of 2.8 nm corresponds well to the FWHM extracted from the AFM measurements, which was determined to be 3.8 nm. The difference between these results can most likely be attributed to the fact that the actual profile measured with AFM is a skewed distribution such that a tail exists on the lower particle height side of the distribution, which was not modeled when performing the least-squares fit with the Gaussian distribution. Furthermore, the minimum is broad and a change in the FWHM value of ±2.0 nm only increases the residual error by 3.5%. However, the residual error of the fit clearly improves by using a Gaussian distribution and indicates that depth profiling in the TXRF geometry is a technique sensitive enough to detect the difference between particles that all have the same height and those that exist as a distribution of heights.

[Figure 5]
Figure 5
The residual error is shown as a function of FWHM for a number of fits performed using the Gaussian distribution to model the concentration profile of particles. As can be seen, the best fit occurs at approximately 2.8 nm.

4. Conclusion

In conclusion, it was demonstrated that measuring the fluorescence intensity versus the angle of incidence for samples with particle-like contaminants grown on the surface can yield quantitative information, although the choice of the concentration profile can subtly change the results. In this study, when using a concentration profile representative of particles of all the same height, the resulting least-squares fit to the fluorescence signal angle scan showed significant differences to the data measured, especially at smaller angles. However, by using a concentration profile that took a weighted average of a distribution of particles, as determined via AFM measurements, it was found that the predicted theoretical fluorescence more accurately corresponded to the data. Finally, it was possible to obtain the particle height distribution directly from the GIXRF data by adding a Gaussian particle height distribution to the model and using a least-squares fit to minimize the residual error resulting in a particle height distribution of 2.8 nm. By identifying the nature of the contaminants on silicon wafer surfaces, it should be possible to better determine and eliminate the source of processing issues when they arise in the semiconductor fabrication plant.

Supporting information


Acknowledgements

We would like to thank the staff at SSRL for their expert technical assistance. This work was performed at SSRL, which is supported by the Department of Energy, Office of Basic Energy Sciences. The support of SIWEDS is also acknowledged. SHN acknowledges support from the Swiss National Science Foundation (SNSF), project No. 148569.

References

First citationButler, I. B., Schoonen, M. A. A. & Rickard, D. T. (1994). Talanta, 41, 211–215.  CrossRef CAS Web of Science Google Scholar
First citationHockett, R. S. (1994). MRS Online Proc. Libr. Arch. 354, 377.  Google Scholar
First citationHoefflinger, B. (2011). Editor. Chips 2020: A Guide to the Future of Nanoelectronics, pp. 161–174. Berlin, Heidelberg: Springer.  Google Scholar
First citationHönicke, P., Kayser, Y., Beckhoff, B., Müller, M., Dousse, J.-C., Hoszowska, J. & Nowak, S. H. (2012). J. Anal. At. Spectrom. 27, 1432–1438.  Google Scholar
First citationKasnavi, R., Sun, Y., Mount, G., Pianetta, P., Griffin, P. B. & Plummer, J. D. (2001). Electrochem. Solid-State Lett. 4, G1–G3.  Web of Science CrossRef CAS Google Scholar
First citationKayser, Y., Hönicke, P., Banaś, D., Dousse, J.-C., Hoszowska, J., Jagodziński, P., Kubala-Kukuś, A., Nowak, S. H. & Pajek, M. (2015). J. Anal. At. Spectrom. 30, 1086–1099.  Web of Science CrossRef CAS Google Scholar
First citationKern, W. (2008). Handbook of Silicon Wafer Cleaning Technology, pp. 3–92. Amsterdam: Elsevier.  Google Scholar
First citationKlockenkämper, R. & von Bohlen, A. (2014). Total-Reflection X-ray Fluorescence Analysis and Related Methods. New York: Wiley.  Google Scholar
First citationLi, F., Balazs, M. K. & Anderson, S. (2005). J. Electrochem. Soc. 152, G669.  Web of Science CrossRef Google Scholar
First citationMeirer, F., Singh, A., Pianetta, P., Pepponi, G., Meirer, F., Streli, C. & Homma, T. (2010). Trends Anal. Chem. 29, 479–496.  Web of Science CrossRef CAS Google Scholar
First citationNowak, S. H., Reinhardt, F., Beckhoff, B., Dousse, J.-C. & Szlachetko, J. (2013). J. Anal. At. Spectrom. 28, 689–696.  Web of Science CrossRef CAS Google Scholar
First citationPahlke, S. (2003). At. Spectrosc. 58, 2025–2038.  Web of Science CrossRef Google Scholar
First citationPahlke, S., Fabry, L., Kotz, L., Mantler, C. & Ehmann, T. (2001). At. Spectrosc. 56, 2261–2274.  Web of Science CrossRef Google Scholar
First citationPianetta, P., Baur, K., Singh, A., Brennan, S., Kerner, J., Werho, D. & Wang, J. (2000). Thin Solid Films, 373, 222–226.  Web of Science CrossRef CAS Google Scholar
First citationPianetta, P., Takaura, N., Brennan, S., Tompkins, W., Laderman, S. S., Fischer-Colbrie, A., Shimazaki, A., Miyazaki, K., Madden, M., Wherry, D. C. & Kortright, J. B. (1995). Rev. Sci. Instrum. 66, 1293–1297.  CrossRef CAS Web of Science Google Scholar
First citationReinhardt, F., Beckhoff, B., Pollakowski, B., Kolbe, M., Osán, J., Török, S., Schoengen, M., Nowak, S., Dousse, J.-C., Bresch, H., Seeger, S. & Waldschläger, U. (2012). Proceedings of the European Conference on X-ray Spectrometry (EXRS 2012), 18–22 June 2012, Vienna, Austria.  Google Scholar
First citationSchwenke, H., Knoth, J., Fabry, L., Pahlke, S., Scholz, R. & Frey, L. (1997). J. Electrochem. Soc. 144, 3979–3983.  CrossRef CAS Web of Science Google Scholar
First citationSingh, A. (2004). PhD thesis, Stanford University, USA.  Google Scholar
First citationSingh, A., Luening, K., Brennan, S., Homma, T., Kubo, N. & Pianetta, P. (2004). AIP Conf. Proc. 705, 1086–1089.  CrossRef CAS Google Scholar
First citationYagi, Y., Imaoka, T., Ksama, Y. & Ohmi, T. (1992). IEEE Trans. Semicond. Manuf. 5, 121–127.  CrossRef Web of Science Google Scholar
First citationYamagami, M., Nonoguchi, M., Yamada, T., Shoji, T., Utaka, T., Nomura, S., Taniguchi, K., Wakita, H. & Ikeda, S. (1999). X-ray Spectrom. 28, 451–455.  CrossRef CAS Google Scholar

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds