research papers
Surface via differential electron yield
aToyota Central R&D Labs Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192, Japan, and bAichi Synchrotron Radiation Center, 250-3 Minamiyamaguchi-cho, Seto, Aichi 489-0965, Japan
*Correspondence e-mail: isomura@mosk.tytlabs.co.jp
Surface-sensitive analysis via extended X-ray absorption fine-structure (EXAFS) spectroscopy is demonstrated using a thickness-defined SiO2 (12.4 nm)/Si sample. The proposed method exploits the differential electron yield (DEY) method wherein Auger electrons escaping from a sample surface are detected by an electron analyzer. The DEY method removes local intensity changes in the spectra caused by photoelectrons crossing the Auger peak during X-ray energy sweeps, enabling analysis through Fourier transformation of wide-energy-range spectral oscillations. The Si K-edge DEY X-ray absorption near-edge structure (XANES) spectrum appears to comprise high amounts of SiO2 and low Si content, suggesting an analysis depth, as expressed using the inelastic of electrons in general electron spectroscopy, of approximately 4.2 nm. The first nearest neighbor (Si—O) distance derived from the Fourier transform of the Si K-edge DEY-EXAFS oscillation is 1.63 Å. This value is within the reported values of bulk SiO2, showing that DEY can be used to detect a of 12.4 nm thickness with an analysis depth of approximately 4.2 nm and enable `surface analysis using Fourier transformation.
Keywords: XAS; EXAFS; silicon dioxide; partial electron yield; surface-sensitive.
1. Introduction
). However, has rarely been applied for surface analysis with an analysis depth of a few nanometers.
is increasingly required for the surface analysis of materials because it provides information on not only chemical states but also on local atomic structures, which cannot be obtained through general surface analysis methods such as (XPS) or A particular type of extended X-ray absorption fine structure (EXAFS) spectroscopy, with Fourier transformation of the spectral oscillations, can be used to determine interatomic distances and coordination numbers (Teo & Joy, 1980Partial electron yield (PEY), which is used to detect electrons escaping from material surfaces, has been proposed as a surface-sensitive method (Brennan et al., 1981; Stöhr, 1979; Nakanishi & Ohta, 2012). One particular method for detecting Auger electrons with elemental-specific energy is called (AEY) (Citrin et al., 1978; Brennan et al., 1981). However, simultaneously produced photoelectrons undergo changes in their energy during an energy sweep of incident X-rays. Hence, the photoelectron peaks often cross the Auger peaks at fixed energies, causing local intensity changes in the spectra. These local changes are a critical problem for which requires a wide-energy-range spectrum of more than 400 eV. Stöhr (1979) proposed a method to avoid photoelectron crossing by detecting with low energy. However, these which are electrons that have lost energy in the solid bulk, originate primarily from Auger electrons, suggesting a greater depth than the AEY (Isomura et al., 2015). In most cases, PEY measurement is performed using X-ray absorption near-edge structure (XANES) spectroscopy, which does not require a wide-energy-range spectrum and is analyzed by comparison with the spectra of standard materials. In the case of XANES, measurements of low absorption energy such as the L-edge are more surface sensitive than those of K-edges even in total electron yield (TEY) (Kasrai et al., 1996).
We previously reported on the differential electron yield (DEY) method, one of the PEY methods that can avoid photoelectron crossing (Isomura et al., 2016). DEY can be surface sensitive because it detects Auger electrons. However, the study only showed that DEY could be used to perform analysis using Fourier transformation of the spectral oscillations, and the analysis depth was not confirmed because a bulk sample was used. In this study, the surface-sensitive performance of the DEY-EXAFS method is demonstrated using a thickness-defined sample (SiO2/Si).
2. Experimental
The experiments were performed at the soft X-ray et al., 2014; Isomura et al., 2015), which has an electron storage ring with a circumference of 72 m and is operated at an electron energy of 1.2 GeV with a current of 300 mA. White light from a bending magnet was monochromated by an InSb(111) double-crystal monochromator. The beam size at the sample position was approximately 2 mm (horizontal) × 1 mm (vertical). The horizontal size of the irradiated region of the sample surface depended on the sample tilt.
beamline BL6N1 of the Aichi Synchrotron Radiation Center (AichiSR) (YamamotoThe electron analyzer (PHOIBOS 150, SPECS GmbH) can operate over a range of kinetic energies (from 1 to 3500 eV). It comprises a hemispherical energy analyzer with a mean radius of 150 mm, a pre-retarding combined second-order focusing-lens system, and a two-dimensional event-counting detector equipped with a multichannel plate, a phosphor screen and a charge-coupled device camera. In the experiments, the pass energy was 10 eV and total energy resolution E/ΔE was approximately 2500. The X-ray beam from the beamline was horizontally incident and horizontally polarized. The axis of the input lens of the analyzer (acceptance angle = ±5°) was on the horizontal plane and the angle between the axis and the incident beam was 54°. The take-off angle of the analyzed electrons was set to 90° (normal to the surface). In the DEY measurements, electrons emitted from the sample surface were detected by the electron analyzer during X-ray energy sweeps. In the TEY measurements performed for comparison, a sample drain current was measured. The base pressure of the main chamber was approximately 5 × 10−8 Pa.
The sample structure was a SiO2 (12.4 nm)/Si(111) film formed by thermal oxidization of Si. The film thickness was measured by an ellipsometer (L115C, Gaertner Scientific Co.).
3. Results and discussion
Fig. 1 shows the XPS spectrum of the SiO2/Si sample surface under irradiation at a photon energy of 1860 eV. In the spectrum, the Auger and photoelectron peaks that can be assigned to Si and O contained in the sample are observed. The Auger peak at 1608 eV is assigned to Si KLL (Johansson et al., 2003). The Auger and background intensities were monitored at electron energies of 1608 and 1628 eV, respectively, during the X-ray energy sweeps as part of the two types of measurements (hereafter `Auger and `background respectively). The electron energy for the background should be set as far from the Si KLL peak as possible to avoid the overlap. However, the energy difference between the Auger and background should be small because those energies should essentially be the same, and was set to 20 eV in consideration of the Si KLL peak tail.
The Auger and background . The Auger and background intensities are normalized by the incident X-ray intensities determined using the current of an Al mesh inserted into the path of the X-ray beam. The Auger spectrum corresponds to the AEY spectrum. As can be observed in Fig. 2, the Si K-edge is seen at 1850 eV in the Auger spectrum but not in the background spectrum. The local intensity increase at 2140 eV is caused by the O 1s photoelectron crossing in the Auger spectrum. A hill-like increase at the higher peak energy is caused by crossing of the energy-loss spectral shape of the O 1s photoelectrons with in the solid. In general, analysis using Fourier transformation requires at least 400 eV ranging from the These increases, which are caused by the photoelectrons, disenable analysis because they disturb the analyzed small spectral oscillations. However, the increases are also observed in the background spectrum, although at different energies from the Auger spectrum.
spectra are shown in Fig. 2The positions of the increases in the background , was obtained following subtraction of the background spectrum from the Auger spectrum. This subtraction was performed after down-shifting the energy level of the background spectrum by 20 eV, following the procedure for DEY-EXAFS analysis (Isomura et al., 2016). The increases caused by the O 1s photoelectrons and energy-loss shape are both removed in the DEY-EXAFS spectrum. In addition to the Si K-edge at 1850 eV, local maxima appear in the DEY-EXAFS spectrum at 1930, 2050 and 2170 eV, likely as a result of oscillations.
spectrum are shifted toward higher energies (by 20 eV) than those in the Auger spectrum because the monitoring energy for the background was placed at an electron energy that was 20 eV higher than that of the Auger energy and the photoelectron peaks crossed each monitoring energy at photon energies that differed from each other by 20 eV. The DEY-EXAFS spectrum, which is shown in Fig. 3The XANES spectrum of DEY is shown in Fig. 4, along with that of TEY with an analysis depth of a few tens of nanometers in the Si K-edge (Nakanishi & Ohta, 2012) for comparison. In the TEY spectrum, peaks are observed at 1842 and 1848 eV, which are assigned to Si and SiO2, respectively (Nakanishi & Ohta, 2012). On the other hand, the DEY spectrum seems to comprise high amounts of SiO2 and low Si content. The inelastic (IMFP) of electrons in SiO2 is estimated to be 4.2 nm at a of 1608 eV, calculated using the TPP-2M formula (Tanuma et al., 1994). Ninety-five percent of the total signal originates from three times the depth of IMFP (Bare et al., 2016), which is called the `information depth' of XPS and is calculated to be 12.6 nm. This value is in close agreement with or slightly more than the SiO2 thickness of 12.4 nm and is consistent with the above-mentioned result that the DEY spectrum comprises high amounts of SiO2 and low amounts of Si. Conversely, it translates to an analysis depth, expressed using the IMFP in general electron spectroscopy, of approximately 4.2 nm for the Si K-edge of SiO2. For comparison, the analysis depth of TEY seems to be 25–30 nm, which is the SiO2 film thickness for which the substrate intensity is reduced to 1/e (approximately 37%) for SiO2/Si (Nakanishi & Ohta, 2012).
Fig. 5 shows the oscillation as a function of wavevector extracted from the DEY-EXAFS spectrum shown in Fig. 3 using the ATHENA program (Ravel & Newville, 2005). The Fourier transform for an oscillation range of k = 3–10 Å−1 (without considering the phase shifts) derived from the oscillation is shown in Fig. 6. The spike noise at 8.65 Å−1 can be seen in Fig. 5. This was caused by a small mismatch of data points between the Auger and background, because the subtraction of those spectra with a steep fluctuation due to the photoelectron crossing was performed. However, the local peak in the oscillation generally has little influence on the derived Fourier transform. The first nearest neighbor distance was calculated via a fitting analysis using the ARTEMIS program (Ravel & Newville, 2005), and the phase shift and backward scattering factor values were calculated via FEFF (Zabinsky et al., 1995; Ankudinov et al., 1998). The parameters used included the atomic distance, amplitude and edge energy whereas the Debye–Waller factor was fixed. The amplitude reduction factor was set to 1.021, determined from the TEY-EXAFS of bulk SiO2. The obtained Si—O distance was 1.63 Å with a reliability factor of 0.02. Barranco et al. (2001), Kamijo et al. (1996) and Gritsenko (2008) reported Si—O distances of 1.66, 1.64 and 1.62 Å, respectively. It is believed that these values vary because SiO2 has various crystal structures such as quartz and cristobalite. Our result was within these reported values, showing that the DEY method can detect a 12.4 nm-thick with an analysis depth of approximately 4.2 nm and, unlike XANES analysis, which relies on comparison with spectra of standard samples, allows for `surface analysis using Fourier transformation. In addition, this method does not require a sample with very smooth surface essentially, as detected at the surface normal, which is contrasted with the method detecting fluorescent X-rays or electrons at grazing angles for surface-sensitive measurements (Shinoda et al., 2010; Amemiya et al., 2003).
4. Conclusions
A surface-sensitive 2 (12.4 nm)/Si sample. The Si K-edge DEY-XANES spectrum appears to comprise a high amount of SiO2 and low amounts of Si, suggesting an analysis depth, expressed using the IMFP in general electron spectroscopy, of approximately 4.2 nm. The first nearest neighbor (Si—O) distance derived from a Fourier transform of the Si K-edge DEY-EXAFS oscillation was 1.63 Å, which is within the reported values of SiO2. This result shows that DEY can detect a of 12.4 nm thickness with an analysis depth of approximately 4.2 nm and allows for analysis through Fourier transformation. We expect that this `surface method will become a useful tool for surface analysis.
analysis exploiting the DEY method was demonstrated using a thickness-defined SiOAcknowledgements
The authors are grateful to Dr Masao Kamada, Saga University, who co-developed the DEY-EXAFS method used in this study. The authors thank Dr Takamasa Nonaka, Toyota Central R&D Labs Inc., for his advice. Synchrotron radiation measurements were performed at BL6N1 of AichiSR, Aichi Science and Technology Foundation (Experimental No. 201502022).
References
Amemiya, K., Kitagawa, S., Matsumura, D., Yokoyama, T. & Ohta, T. (2003). J. Phys. Condens. Matter, 15, S561–S571. Web of Science CrossRef CAS Google Scholar
Ankudinov, A. L., Ravel, B., Rehr, J. J. & Conradson, S. D. (1998). Phys. Rev. B, 58, 7565–7576. Web of Science CrossRef CAS Google Scholar
Bare, S. R., Knop-Gericke, A., Teschner, D., Hävacker, M., Blume, R., Rocha, T., Schlögl, R. A., Chan, S. Y., Blackwell, N., Charochak, M. E., ter Veen, R. & Brongersma, H. H. (2016). Surf. Sci. 648, 376–382. Web of Science CrossRef CAS Google Scholar
Barranco, A., Mejías, J. A., Espinós, J. P., Caballero, A., González-Elipe, A. R. & Yubero, F. (2001). J. Vac. Sci. Technol. A, 19, 136–144. Web of Science CrossRef CAS Google Scholar
Brennan, S., Stöhr, J. & Jaeger, R. (1981). Phys. Rev. B, 24, 4871–4874. CrossRef CAS Web of Science Google Scholar
Citrin, P. H., Eisenberger, P. & Hewitt, R. C. (1978). Phys. Rev. Lett. 41, 309–312. CrossRef CAS Web of Science Google Scholar
Gritsenko, V. A. (2008). Phys. Usp. 51, 699. Web of Science CrossRef Google Scholar
Isomura, N., Kamada, M., Nonaka, T., Nakamura, E., Takano, T., Sugiyama, H. & Kimoto, Y. (2016). J. Synchrotron Rad. 23, 281–285. Web of Science CrossRef CAS IUCr Journals Google Scholar
Isomura, N., Soejima, N., Iwasaki, S., Nomoto, T., Murai, T. & Kimoto, Y. (2015). Appl. Surf. Sci. 355, 268–271. Web of Science CrossRef CAS Google Scholar
Johansson, L. I., Virojanadara, C., Eickhoff, Th. & Drube, W. (2003). Surf. Sci. 529, 515–526. Web of Science CrossRef CAS Google Scholar
Kamijo, N., Handa, K. & Umesaki, N. (1996). Mater. Trans. JIM, 37, 927–931. CrossRef CAS Google Scholar
Kasrai, M., Lennard, W. N., Brunner, R. W., Bancroft, G. M., Bardwell, J. A. & Tan, K. H. (1996). Appl. Surf. Sci. 99, 303–312. CrossRef CAS Web of Science Google Scholar
Nakanishi, K. & Ohta, T. (2012). Surf. Interface Anal. 44, 784–788. Web of Science CrossRef CAS Google Scholar
Ravel, B. & Newville, M. (2005). J. Synchrotron Rad. 12, 537–541. Web of Science CrossRef CAS IUCr Journals Google Scholar
Shinoda, K., Suzuki, S., Yashiro, K., Mizusaki, J., Uruga, T., Tanida, H., Toyokawa, H., Terada, Y. & Takagaki, M. (2010). Surf. Interface Anal. 42, 1650–1654. Web of Science CrossRef CAS Google Scholar
Stöhr, J. (1979). J. Vac. Sci. Technol. 16, 37. Google Scholar
Tanuma, S., Powell, C. J. & Penn, D. R. (1994). Surf. Interface Anal. 21, 165–176. CrossRef CAS Web of Science Google Scholar
Teo, B. K. & Joy, D. C. (1980). EXAFS Spectroscopy. New York: Plenum. Google Scholar
Yamamoto, M., Yoshida, T., Yamamoto, N., Yoshida, H. & Yagi, S. (2014). e-J. Surf. Sci. Nanotech. 12, 299–303. CrossRef CAS Google Scholar
Zabinsky, S. I., Rehr, J. J., Ankudinov, A., Albers, R. C. & Eller, M. (1995). Phys. Rev. B, 52, 2995–3009. CrossRef CAS Web of Science Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.