|
Figure 10
Measured (solid lines) and calculated (dashed lines) HiOS transmission for the AlF3 coating at different incidence angles. Calculation based on optical parameters obtained from fitting on test samples. |
Open
access
![Open Access](/logos/open.png)
|
Figure 10
Measured (solid lines) and calculated (dashed lines) HiOS transmission for the AlF3 coating at different incidence angles. Calculation based on optical parameters obtained from fitting on test samples. |