Low-dose X-ray structure analysis of cytochrome c oxidase utilizing high-energy X-rays
aSR Life Science Instrumentation Team, Life Science Research Infrastructure Group, Advanced Photon Technology Division, RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan, bPicobiology Institute, Graduate School of Life Science, University of Hyogo, 3-2-1 Kouto, Kamigori, Akoh, Hyogo 678-1297, Japan, cInstitute for Protein Research, Osaka University, 3-2 Yamadaoka, Suita, Osaka 565-0871, Japan, and dProtein Crystal Analysis Division, Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan
*Correspondence e-mail: yamamoto@riken.jp
To investigate the effect of high-energy X-rays on site-specific radiation-damage, low-dose diffraction data were collected from radiation-sensitive crystals of the metal enzyme cytochrome c oxidase. Data were collected at the Structural Biology I beamline (BL41XU) at SPring-8, using 30 keV X-rays and a highly sensitive pixel array detector equipped with a cadmium telluride sensor. The experimental setup of continuous sample translation using multiple crystals allowed the average diffraction weighted dose per data set to be reduced to 58 kGy, and the resulting data revealed a ligand structure featuring an identical bond length to that in the damage-free structure determined using an X-ray free-electron laser. However, precise analysis of the residual density around the ligand structure refined with the synchrotron data showed the possibility of a small level of specific damage, which might have resulted from the accumulated dose of 58 kGy per data set. Further investigation of the photon-energy dependence of specific damage, as assessed by variations in UV-vis absorption spectra, was conducted using an on-line spectrometer at various energies ranging from 10 to 30 keV. No evidence was found for specific radiation damage being energy dependent.
PDB reference: bovine heart cytochrome c oxidase, 6j8m
1. Introduction
Radiation damage of crystalline specimens caused by incident X-rays in macromolecular crystallography (MX) manifests as degradation of crystal quality (global damage) and local structural changes in molecules (specific damage) as the accumulated dose increases. This is an intrinsic problem associated with the use of highly brilliant light sources at synchrotron facilities, and is undesirable for researchers who wish to complete diffraction data sets or to determine intact molecular structures. Although the absorption of photons by macromolecular crystals, which is proportional to dose, can be decreased by utilization of high-energy (i.e. short-wavelength) X-rays, the reduction in diffraction intensity and area-detector efficiency in this energy region presents an obstacle to practical experiments. However, the rate of radiation damage could be reduced by using a sufficiently efficient area detector for high-energy photons. Starting with the Darwin's formula (Darwin, 1914, 1922; Blundell & Johnson, 1976) for the X-ray diffraction intensity from crystalline samples, Arndt (1984) showed that the optimal X-ray wavelength for MX could be chosen in terms of the efficiency, which is given by the diffraction intensity divided by the total absorbed photon energy. At least in the X-ray energy range up to 30 keV, efficiency is positively correlated with photon energy, implying that higher energies are better for low-dose data collection. Consistent with Arndt (1984), Paithankar & Garman (2010) and Fourme et al. (2012) also suggested that in the energy range between 20 and 40 keV there is an optimal energy for efficient data collection, with detailed estimation taking into account prominent effects for high-energy photons such as Compton scattering and photo-electron escape, as well as protein composition, crystal size and other factors.
In addition to dose-efficiency, Fourme et al. (2012) pointed out that another possible advantage of using high-energy X-rays for MX was the lower experimental errors caused by the lower absorption and the lower extinction effects of crystalline samples. Those effects appear as a reduction in diffraction intensity and the extent is dependent on the X-ray energy, originating from the cross sections of the constituent elements or diffraction quality of the crystalline samples. The of a sample is approximately proportional to the cube of the X-ray wavelength (Helliwell et al., 1993) and the extinction distance of the incident beam in a crystal is proportional to the X-ray energy (Becker, 1977). Therefore the use of higher-energy X-rays makes it possible to collect diffraction intensities with smaller errors.
Another issue pertaining to changing the X-ray energies used for MX is the energy dependence of radiation damage, which also has been investigated in a number of pioneering studies. Weiss et al. (2005) investigated site-specific damage by analyzing the decay of difference Fourier peak heights at metal sites of a cadmium derivative of porcine pancreatic elastase using two different wavelengths (1.0 Å and 2.0 Å), and detected no energy dependence. Shimizu et al. (2007) performed a systematic comparison of diffraction intensity statistics of data sets from lysozyme crystals by changing the X-ray energy in nine steps from 6.5 to 33 keV, and concluded that global damage is independent of X-ray energy. Liebschner et al. (2015) also reported that there was no significant difference in global damage to the diffraction intensity of thaumatin crystals in data collected at energies ranging from 6.33 to 19.0 keV. On the other hand, Homer et al. (2011) compared the rate of electron density decay at cysteine sulfurs in lysozyme crystals versus dose, and reported greater specific damage at 14 keV than at 9 keV. Of course, it is difficult to directly compare the results of different studies, some of which reach incompatible conclusions regarding energy dependence, reflecting the fact that different proteins, crystal size and various X-ray energies were used. Particularly in the case of site-specific damage, the phenomenon is dependent on the property of individual sites and environments, including chemical structure, hydrophilicity, and position of the amino acid in the molecule or crystal, making quantitative and uniform evaluation difficult. Therefore, because the results obtained with a particular specimen might not be applicable to another experiment using a distinct protein sample, it would still be worthwhile to characterize the specific radiation damage caused by high-energy X-rays. In any case, it is important to address this issue because data which is one of the advantages of utilizing high-energy X-rays for MX, could be enhanced or diminished by the X-ray energy-dependence of radiation damage if it occurs.
Bovine heart cytochrome c oxidase (CcO) is an enzyme that functions in the cellular respiratory electron transport chain in the mitochondrial inner membrane. CcO accepts four electrons from cytochrome c to reduce molecular oxygen (O2) to two waters, coupled with the pumping of four protons through the membrane in each catalytic turnover (Yoshikawa & Shimada, 2015; Wikström et al., 2018). In its resting oxidized state, it binds a peroxide anion at the O2-reduction center, which consists of a copper ion and a heme iron. However, in synchrotron-based MX, the peroxide is readily reduced to water by X-ray irradiation while the diffraction image is recorded, and the bond length between the two oxygen atoms of the peroxide increases as the dose accumulates. To obtain the intact structure, Aoyama et al. (2009) performed a low-dose X-ray diffraction experiment on bovine CcO using a large number of crystals to minimize the X-ray dose absorbed by each one. However, the bond length determined for the bridging ligand, 1.7 Å, was too large for an O—O single bond. Based on the reported experimental conditions, the average diffraction weighted dose (DWD) per data set for this study was estimated as 277 kGy using RADDOSE-3D (Zeldin et al., 2013). The intact of the ligand compound was ultimately confirmed as a peroxide by the serial femtosecond rotation crystallography (SF-ROX) method utilizing the XFEL at SACLA (Hirata et al., 2014).
As suggested by many previous studies, dose-efficient data collection with high-energy X-rays can be practical if a highly efficient area detector for high-energy photons is used. Recently, owing to progress in technologies to apply high-Z semiconductors such as cadmium telluride (CdTe) to a device, several commercial products applicable to MX have become available. The use of one of these novel detectors for MX, especially for analysis of a radiation-sensitive metal enzyme like CcO, will provide the opportunity to address the nature of the energy dependence of specific radiation damage and expand the application of high-energy synchrotron sources.
In this study, we assessed site-specific radiation damage in a radiation-sensitive protein using high-energy X-rays. In particular, low-dose diffraction data were collected from CcO crystals using 30 keV X-rays at BL41XU, SPring-8 (Hasegawa et al., 2013). A highly sensitive pixel array detector equipped with a CdTe sensor (PILATUS3 X CdTe, DECTRIS) was utilized for data collection by the shutter-less helical scanning method. Maintaining the DWD at 58 kGy per data set by controlling translation-speed and frame-rate settings, we collected a diffraction data set at 1.9 Å resolution (dose estimation with RADDOSE-3D). Furthermore, to investigate the possibility of X-ray energy dependence of site-specific damage to the O2-reduction center, we applied UV-vis absorption spectroscopy, which sensitively reflects the transient redox state of the heme at this site.
2. Methods
2.1. analysis of CcO with 30 keV X-rays
BL41XU at SPring-8 is a beamline for MX, with high-energy X-rays being available at one of its two end-stations. Utilizing the third harmonic of the undulator, high-energy X-rays ranging from 20 to 35 keV, concentrated by a compound refractive lens (CRL; KIT-IMT), are available at this source. The beam parameters at the sample position used for this study were as follows: horizontal and vertical beam size 0.044 mm × 0.047 mm (top-hat shape assumed for dose calculation); 11 photons s−1; photon energy 30 keV. Usually a CMOS flat-panel detector C10158DK-11 (X) (Hamamatsu Photonics) with a 0.3 mm-thick caesium iodide phosphor is installed, but, at the time this study was conducted, a PILATUS3 X CdTe 300K detector was temporarily available for test use.
8.2 × 10The PILATUS3 X CdTe 300K is a photon-counting pixel array detector with a highly sensitive sensor for high-energy photons consisting of a 1 mm-thick CdTe depletion layer. The pixel dimensions of the horizontal and vertical aperture are 487 × 619 pixels, with a pixel size of 0.172 mm × 0.172 mm. The detector provides a continuous readout of images at a maximum frame rate of 500 Hz (i.e. frame acquisition time of 2 ms) with a readout time of 0.95 ms. The photo-absorption efficiency of CdTe is 100% up to 40 keV photon energy, at which conventional silicon sensors of the same thickness yield significantly lower values and are therefore impractical for use (Fig. 1). Except for the small area size, the specifications of the detector are close to those of an ideal detector for high-energy MX.
In this study, we collected diffraction data under the conditions shown in Table 1. The shutter-less helical scanning method was applied to large thick crystals of CcO. Because the translation step between each frame was smaller than the beam width, the crystal volume in the footprint of incident beam consisted of a gradation of fresh and damaged portions along the translation axis, at each moment that a diffraction image was recorded. In this case, the dose estimated as the `average diffraction weighted dose' (DWD) by RADDOSE-3D is a good description of the dose in the irradiated crystal volume at each moment; this value was 58.0 kGy per data set. Finally, using nine crystals in total, we collected a complete dataset to 1.9 Å resolution (sample to detector distance of 350 mm). A series of helical scanning frame acquisitions was collected by exposing each of the nine utilized crystals from one end to the other with constant rotation around, and translation along, the spindle axis of the horizontal-spindle goniometer. For each crystal, the origin of spindle angle was defined as the broad face of the crystal (typically 0.8 mm × 0.8 mm × 0.2 mm in size, but varying) when it was perpendicular to the incident beam. This makes it possible to align the crystal orientation to the incident beam, because the thin side of a CcO crystal corresponds to the b-axis of a Typically, a wedge of 30° to 40° diffraction images were collected from a crystal, successively. The starting angle of each helical scanning was defined to continue the previous scanning to cover the hemisphere of the efficiently. If the fresh volume of the crystal was large enough, one or two extra scans were applied after displacing the crystal position perpendicular to the spindle axis so that the irradiated volumes did not overlap with each other. In those cases, the distance of the displacement was determined by considering the width of the footprint of irradiated volume perpendicular to the spindle axis estimated by the function (V + T sinω)/cosω, where V, T and ω represent vertical beam size (= 0.047 mm), crystal thickness (= 0.2 mm) and spindle angle, respectively. Because of the small detector size, the detector was vertically offset by 30 mm, and two series of data sets using different horizontal offsets (+35 mm and −35 mm) were collected to cover the required resolution range and multiplicity of diffraction intensities.
|
The data acquisition conditions, including the exposure time and rotation angle of each frame, were carefully determined to achieve data quality comparable with previous studies (Aoyama et al., 2009; Hirata et al., 2014). However, due to limitations on the number of crystals and available beam time, we set the goniometer translation speed (i.e. the step between frames) to lower than the maximum value allowed. Consequently, the DWD per data set of 58 kGy was the result of a compromise: if the translation speed had been set ten times higher, and the samples had been exchanged ten times more often, it would have been possible to decrease the DWD per data set to 5.8 kGy in order to complete the dataset.
In total, 4020 diffraction images were processed and merged with XDS and XSCALE (Kabsch, 2010). Data collection conditions, along with data processing and are shown in Table 2. The initial phases of structure factors up to 4.0 Å resolution were determined by the rigid-body method with REFMAC (Murshudov et al., 2011), using the structure of ligand-free fully reduced CcO previously determined at 1.6 Å resolution [Protein Data Bank (PDB) ID: 5b1b] as the initial model. We chose the structure of a ligand-free protein in a different redox state as a search model to eliminate the model bias in the result of the calculation. The phases were extended to 1.9 Å resolution by the density modification method (Wang, 1985) coupled with averaging using the CCP4 (Collaborative Computational Project, Number 4, 1994) program DM (Winn et al., 2011). The with minimized model bias was calculated using the resultant phases. Structure was conducted with REFMAC. Bulk solvent correction and the anisotropic scaling of the observed and calculated structure amplitudes were incorporated into the Anisotropic temperature factors for the iron, copper and zinc atoms were imposed on the model. The quality of the structure was evaluated based on the R and Rfree values. Other than the O2-reduction center, no substantial changes were detected relative to the previously reported structure (Aoyama et al., 2009; Hirata et al., 2014). The coordinates and structure factors were deposited in the PDB with PDB-ID 6j8m.
‡Value of the highest resolution shell. |
2.2. Visible absorption spectroscopy
As reported previously (Aoyama et al., 2009), X-ray irradiation of the CcO crystal (photon energy of 13.8 keV) induces changes in the UV-vis The absorption increases at 604 and 582 nm are assignable to reduction of heme a and formation of a low-spin ferrous heme a3, respectively, even at cryogenic temperatures. Also the absorption band in the vicinity of 650 nm which can be seen only in the resting oxidized state of CcO is assignable to the existence of high-spin ferric heme a3, and decreases as dose accumulates. Therefore, the change in the UV-vis as a function of absorbed dose can be used as an indicator of the radiation-induced heme reduction/ligand exchange, which reflects specific radiation damage at the O2-reduction center during an MX experiment. A number of structural biologists have shown that metal centers of proteins are sensitive to X-ray radiation, and that their absorption spectra change rapidly before a complete diffraction dataset can be collected (e.g. Matsui et al., 2002; Beitlich et al., 2007; Pearson et al., 2007; Hough et al., 2008; McGeehan et al., 2009; Owen et al., 2009). Accordingly, on-line micro-spectrometers have often been implemented as a complementary method to X-ray crystallography in order to investigate specific radiation damage, especially for radiation-sensitive specimen such as metal enzymes. This method is applicable to detecting changes that do not appear in the of crystal structures, and should therefore be useful for assessing the energy dependence of site-specific damage at the O2-reduction center of CcO.
To test this idea, we conducted on-line spectroscopy measurements at 30 keV X-ray energy by setting up a portable spectrometer at BL41XU. Incident and detective fiber optics for visible light were set perpendicular to the X-ray beam at the optic center of the diffractometer. The focus diameter of the visible light was 0.05 mm (1/e width of Gaussian shape), smaller than the X-ray beam size of 0.2 mm × 0.2 mm (square) with a 11 photons s−1. The parallel beam, without a CRL, was attenuated by insertion of a 1 mm-thick aluminium plate, and a top-hat beam shape was assumed for dose calculation using RADDOSE-3D. The CcO crystal size was 0.6 mm × 0.6 mm × 0.2 mm. Under these conditions, the dose rate for CcO was estimated as 1.13 kGy s−1. This setup allowed us to alternate between measurements of absorption spectra with X-ray irradiation by rotating the crystal goniometer spindle back and forth by 90°. The details of this apparatus were reported previously (Aoyama et al., 2009). In addition, to evaluate the energy dependence of the spectral changes, we conducted spectroscopic measurements at another beamline, BL44XU (Higashiura et al., 2016), at the X-ray energies of 10, 13.8 and 17.7 keV. The beam at BL44XU was focused by horizontal and vertical mirror optics, shaped with a 0.05 mm-diameter pinhole device upstream of the sample, and attenuated with aluminium plates. The dose rate for each energy, calculated assuming top-hat shape for the beam, was 1.50, 1.36 and 0.95 kGy s−1, respectively. These three measurements at BL44XU were conducted using one crystal with dimensions 0.5 mm × 0.5 mm × 0.15 mm at three different irradiation points to minimize the sample dependence as much as possible.
of 7.4 × 102.3. Preparation of CcO crystals
CcO in the resting oxidized state was purified from bovine heart mitochondria and crystallized as described previously (Tsukihara et al., 1995; Mochizuki et al., 1999). To stabilize crystals, the crystals were soaked in `stabilization solution' containing 40 mM sodium phosphate buffer, pH 6.5, 0.2% (w/v) n-decyl-β-d-maltoside, 1%(w/v) PEG 4000, and 2%(v/v) ethylene glycol. Then the crystals were flash cooled in a cryo-nitrogen stream at 100 K after soaking in a solution containing 40 mM sodium phosphate, pH 5.7, 0.2% decyl maltoside, 5% PEG 4000, and 45% (v/v) ethylene glycol as a cryo-protectant. The final medium composition was obtained by 50 (or 40) stepwise in situ manual exchange of the stabilization solution with 50 (or 40) different soaking solutions containing steadily increasing ethylene glycol concentrations.
3. Results and discussion
3.1. Low-dose (58 kGy) structure of ligand peroxide
Fig. 2 shows the structure around the O2-reduction center of CcO refined to 1.9 Å resolution based on the structure-factor amplitudes obtained with 30 keV X-rays. Without a ligand model, the Fo − Fc difference map shows an elliptical residual peak between the copper (CuB) and heme a3 iron (Fea3) [Fig. 2(a)]. The ligand model was refined, focusing on its bond length, following the procedure adopted in the damage-free structure analysis of SF-ROX (Hirata et al., 2014) and of Aoyama et al. (2009). Structure with the ligand model, without any restraint on bond length between the two oxygen atoms, yielded a bond length of 1.66 Å, shorter than in previous work in which was performed in a similar manner. When different refinements were started with the initial ligand model having shorter and longer distances of 1.55 and 1.85 Å independently, both cases converged to the same bond length of 1.66 Å. The Fo − Fc map contained a large residual peak next to the peroxide. The ligand bond length was further evaluated by fixing it during the and then varying it from 1.45 to 1.7 Å in increments of 0.05 Å to find the optimal value for describing the structure that yielded the optimal residual density map (Fig. 3). When the bond length of the model was too short, residual density peaks appeared on the outer side of each oxygen atom. Conversely, longer bond lengths enhanced the residual peak next to the bond. Ultimately, the optimal bond length was determined to be 1.55 Å, which did not give large residual peaks neither outside nor beside the bond. This was identical to that in the damage-free structure obtained with SF-ROX (Hirata et al., 2014). Finally, the residual density was minimized by defining multiple conformer models with a 10% minor component of peroxide, similar to the structure analysis by SF-ROX, which used a 5% minor component (Hirata et al., 2014) [Fig. 2(b)].
Table 3 summarizes the results of the structure in comparison with published work (Aoyama et al., 2009; Hirata et al., 2014). When inspecting fixed and refined bond lengths of peroxide, our result regarding the specific damage is comparable with that of the damage-free SF-ROX (Hirata et al., 2014) structure. Thus 30 keV X-rays and a CdTe pixel array detector are feasible for data collection at a dose low enough to identify the intact chemical structure of the radiation-sensitive ligand of CcO.
‡Intensity datasets obtained by Hirata et al. (2014). §Intensity datasets obtained by Aoyama et al. (2009). |
3.2. Energy dependence of the visible absorption spectrum
The visible absorption spectra as a function of dose, measured at four different X-ray energies (10, 13.8, 17.7 and 30 keV), are shown in Fig. 4. At all energies, variations in absorption profile with increasing dose were accompanied by characteristic peak growths at two wavelengths, 604 and 582 nm, as indicated in the figure, and a decrease of the 650 nm peak at high dose. As described above, these changes represent evidence of reduction of heme a and formation of a low-spin ferrous heme a3 and they were confirmed to occur similarly at all X-ray energies. To investigate further, the increases in peak heights relative to the absorbance at the of 630 nm versus dose are plotted in Fig. 5. At all energies, the peaks began to grow at a very early stage of dose accumulation and reached their maximum level at 80–150 kGy. The growth rates of these peak heights are considered to be proportional to the fraction of heme a and heme a3 active sites in the crystal that can change the redox state in response to X-ray irradiation at constant dose rate. Thus, the dose dependence of the peak growth should follow the law of exponential growth, which is analogous to the analysis reported in previous work (Matsui et al., 2002; Borshchevskiy et al., 2014). In those studies, the authors analyzed the dose dependence of the change originated from X-ray-induced generation of orange species in bacteriorhodopsin crystals caused by specific damage to the bound retinal. In our case, the function of [a0 − a1 exp(−d/d0)] was fitted to the peak-growth plots by the least-squares method, where d represents dose, and a0, a1 and d0 are fitting parameters (Fig. 5).
The fitted curve was further analyzed to estimate the relationship between growth rate and dose, by introducing the dose limitation termed `spectroscopic lifedose' (Hersleth & Andersson, 2011), hereafter SLD, which corresponds to the dose at which peak growth reaches 50% (SLD50 or half lifedose) or 95% (SLD95) of the maximum value. The SLDs estimated from the plots in Fig. 5 are summarized in Table 4, and the variation versus photon energy is plotted in Fig. 6. In all cases, SLD50 and SLD95 were of the order of tens to hundreds of kGy, significantly smaller than the experimental dose limit for MX at cryo-temperature; for example, 30000 kGy for the averaged diffraction intensity to decay to 0.7 of its original value (Owen et al., 2006). For the 30 keV data measured at BL41XU, the SLDs had the smallest values out of all the X-ray energies, whereas the SLDs for the other three energies (10, 13.8 and 17.7 keV) all measured at BL44XU using the same crystal, yielded larger SLD values. For these three energies, the variance in the SLDs was small, and the largest SLD50 and SLD95 values were obtained at 10 and 17.7 keV, respectively, whereas the smallest SLDs were obtained at the intermediate energy of 13.7 keV. Hence, at least from these results, there seems to be no consistency in the energy dependence of the SLDs.
|
The difference in the SLDs for 30 keV relative to the other three energies may be the result of differences in the experimental conditions, considering the fact that the measurements at other energies were conducted using a different crystal sample at another beamline with different beam properties. Thus, the results are not suitable for direct comparison. In particular, at BL44XU, the X-ray beam was cut with a 0.05 mm pinhole upstream of the sample, which was comparable with the size of the visible-light beam used for spectroscopy. Therefore, it is possible that the visible absorption profiles measured at BL44XU were affected by bleeding of visible light around the circumference of the X-ray beam, and that the SLDs were overestimated. However, it is obvious that the use of high-energy X-rays at 30 keV did not yield any spectroscopic evidence that specific damage was suppressed.
4. Conclusions
In this study, we performed dose-efficient diffraction data collection at 30 keV incident X-ray energy for the radiation-sensitive metal protein CcO in the resting oxidized state, which is suggested by theoretical arguments to be appropriate for the use of high-energy X-rays for MX. This was achieved by introducing a highly efficient area detector equipped with CdTe sensor material. This experimental setup enabled us to collect a complete dataset at a low dose (58 kGy) up to a resolution of 1.9 Å, comparable with the data quality (resolution, completeness, multiplicity etc.) in former studies on CcO. The ligand peroxide structure was obtained without elongation by specific radiation damage; the bond length of 1.55 Å was comparable with that of the damage-free structure obtained using an XFEL. The final model of CcO converged to a 10% minor component of ligand peroxide at the O2-reduction center, larger than the 5% minor component of the XFEL structure. This difference is likely to represent the structural change caused by specific radiation damage on the structure obtained in the current study using a finite exposure time at the synchrotron source. If this is the case, the existence of a 5% minor component in the XFEL structure raises the question of whether specific damage was also suffered by that structure. In the SF-ROX method, it is possible that radical diffusion in-between successive XFEL shots caused specific damage, even when the crystal has been translated between XFEL pulses. To clarify this, a further investigation with in the absence of any influence from neighboring data collections is required, for instance, SF-ROX with a single XFEL shot for each crystal. In any case, the diffraction data and the resulting we obtained enabled identification of the intact chemical structure of the radiation-sensitive ligand of CcO, indicating that this approach to diffraction data collection with 30 keV X-rays was both practical and useful for MX.
RADDOSE-3D estimates the dose-efficiency for a certain diffraction condition and this is output as the `Diffraction Efficiency' parameter, which corresponds to the elastic yield of diffracted photons divided by the average diffraction weighted dose, and the value for the conditions used in this study for CcO (58 kGy DWD per data set at 30 keV X-ray) was 1.1 × 109 photons kGy−1. In comparison, the value calculated under otherwise identical conditions at an X-ray energy of 13.8 keV is 6.8 × 108 photons kGy−1. In addition, the value calculated for a lower energy of 10 keV is 5.2 × 108 photons kGy−1. This means that the gain in dose-efficiency using 30 keV X-rays versus 13.8 and 10 keV is about 1.6- and 2.1-fold, respectively. Although this increase is not dramatic, the use of higher-energy X-rays significantly benefits researchers intending to collect a complete dataset from multiple crystals, while minimizing the X-ray dose and reducing the number of crystals required. In general, a well known advantage of utilizing high-energy X-rays at MX beamlines is that it enables ultra-high resolution structure analysis. However, with the application of high-Z detectors for such experiments, it will also become possible to use high-energy X-rays for low-dose diffraction data collection, and our ability to obtain intact structures of radiation-sensitive proteins will increase.
By using complementary UV-vis absorption spectroscopy, we observed sensitive variations in the spectra versus dose at all energies from 10 to 30 keV. We obtained no explicit evidence of the merit of using 30 keV X-rays to suppress specific radiation damage. Therefore, we concluded that the result of MX at 30 keV which yielded the short bond length for the ligand peroxide, was not the consequence of the X-ray energy itself, but rather of the low-dose data collection strategy. Furthermore, the comparison of spectroscopic results using identical crystals at BL44XU yielded no evidence that the spectrum change was energy-dependent, at least not at energies ranging from 10 to 17.7 keV.
In this study, the estimated diffraction weighted dose per data set for MX was 58 kGy, still larger than the spectroscopic lifedose (SLD50) at 30 keV. It would be worth conducting an MX study at a lower dose than this value in order to investigate the relationship between spectroscopy and crystal structures at low doses. As mentioned, it would be possible to further decrease the dose by increasing the translation speed of the crystal goniometer during data collection. Specifically, the dose would decrease in inverse proportion to the translation speed, without a reduction of data quality. However, the number of crystals required to complete the data would increase proportionally to the translation speed. In this study, if it had been possible to use a larger area detector (e.g. PILATUS3 X CdTe 1M), it would not have been necessary to offset the detector position. Then the data regarding the number of scan series to cover the hemisphere of the and the number of crystals, would have been better. The application of high-energy X-rays is expected to be further enhanced by the use of novel detectors with improved specifications.
Footnotes
‡Present address: Department of Applied Life Science, Faculty of Applied Biological Sciences, Gifu University, 1-1 Yanagido, Gifu 501-1193, Japan
Acknowledgements
We thank our co-workers and the beamline scientists at SPring-8 for many useful discussion and help in conducting experiments. We also thank Stefan Brandstetter (DECTRIS) and Takeyoshi Taguchi (Rigaku) for technical support. The experiments at SPring-8 BL41XU were carried out with the approval of the Japan Synchrotron Radiation Research Institute (JASRI; proposal Nos. 2016A1001, 2016A2533, 2017A2522).
Funding information
This work was supported by JST CREST (grant No. JPMJCR12M3); Platform Project for Supporting Drug Discovery and Life Science Research [Basis for Supporting Innovative Drug Discovery and Life Science Research (BINDS)] from AMED (grant No. JP18am0101070); Platform Project for Supporting in Drug Discovery and Life Science Research (Platform for Drug Discovery, Informatics, and Structural Life Science) from the Ministry of Education, Culture, Sports, Science and Technology (MEXT), and Japan Agency for Medical Research and Development (AMED).
References
Aoyama, H., Muramoto, K., Shinzawa-Ito, K., Hirata, K., Yamashita, E., Tsukihara, T., Ogura, T. & Yoshikawa, S. (2009). Proc. Natl Acad. Sci. 106, 2165–2169. Web of Science CrossRef PubMed CAS Google Scholar
Arndt, U. W. (1984). J. Appl. Cryst. 17, 118–119. CrossRef CAS Web of Science IUCr Journals Google Scholar
Becker, P. (1977). Acta Cryst. A33, 243–249. CrossRef CAS IUCr Journals Web of Science Google Scholar
Beitlich, T., Kühnel, K., Schulze-Briese, C., Shoeman, R. L. & Schlichting, I. (2007). J. Synchrotron Rad. 14, 11–23. Web of Science CrossRef CAS IUCr Journals Google Scholar
Blundell, T. L. & Johnson, L. N. (1976). Protein Crystallography. New York: Academic Press. Google Scholar
Borshchevskiy, V., Round, E., Erofeev, I., Weik, M., Ishchenko, A., Gushchin, I., Mishin, A., Willbold, D., Büldt, G. & Gordeliy, V. (2014). Acta Cryst. D70, 2675–2685. Web of Science CrossRef IUCr Journals Google Scholar
Collaborative Computational Project, Number 4 (1994). Acta Cryst. D50, 760–763. CrossRef Web of Science IUCr Journals Google Scholar
Darwin, C. G. (1914). Philos. Mag. Ser. 6, 27, 315–333. Google Scholar
Darwin, C. G. (1922). Philos. Mag. Ser. 6, 43, 800–829. Google Scholar
Fourme, R., Honkimäki, V., Girard, E., Medjoubi, K., Dhaussy, A.-C. & Kahn, R. (2012). J. Appl. Cryst. 45, 652–661. Web of Science CrossRef CAS IUCr Journals Google Scholar
Hasegawa, K., Shimizu, N., Okumura, H., Mizuno, N., Baba, S., Hirata, K., Takeuchi, T., Yamazaki, H., Senba, Y., Ohashi, H., Yamamoto, M. & Kumasaka, T. (2013). J. Synchrotron Rad. 20, 910–913. Web of Science CrossRef CAS IUCr Journals Google Scholar
Helliwell, J. R., Ealick, S., Doing, P., Irving, T. & Szebenyi, M. (1993). Acta Cryst. D49, 120–128. CrossRef CAS Web of Science IUCr Journals Google Scholar
Hersleth, H.-P. & Andersson, K. K. (2011). Biochim. Biophys. Acta, 1814, 785–796. Web of Science CrossRef CAS PubMed Google Scholar
Higashiura, A., Yamashita, E., Yoshimura, M., Hasegawa, K., Furukawa, Y., Kumasaka, T., Ueno, G., Yamamoto, M., Tsukihara, T. & Nakagawa, A. (2016). AIP Conf. Proc. 1741, 030028. Google Scholar
Hirata, K., Shinzawa-Itoh, K., Yano, N., Takemura, S., Kato, K., Hatanaka, M., Muramoto, K., Kawahara, T., Tsukihara, T., Yamashita, E., Tono, K., Ueno, G., Hikima, T., Murakami, H., Inubushi, Y., Yabashi, M., Ishikawa, T., Yamamoto, M., Ogura, T., Sugimoto, H., Shen, J., Yoshikawa, S. & Ago, H. (2014). Nat. Methods, 11, 734–736. Web of Science CrossRef CAS PubMed Google Scholar
Homer, C., Cooper, L. & Gonzalez, A. (2011). J. Synchrotron Rad. 18, 338–345. Web of Science CrossRef CAS IUCr Journals Google Scholar
Hough, M. A., Antonyuk, S. V., Strange, R. W., Eady, R. R. & Hasnain, S. (2008). J. Mol. Biol. 378, 353–361. Web of Science CrossRef PubMed CAS Google Scholar
Kabsch, W. (2010). Acta Cryst. D66, 125–132. Web of Science CrossRef CAS IUCr Journals Google Scholar
Liebschner, D., Rosenbaum, G., Dauter, M. & Dauter, Z. (2015). Acta Cryst. D71, 772–778. Web of Science CrossRef IUCr Journals Google Scholar
McGeehan, J., Ravelli, R. B. G., Murray, J. W., Owen, R. L., Cipriani, F., McSweeney, S., Weik, M. & Garman, E. F. (2009). J. Synchrotron Rad. 16, 163–172. Web of Science CrossRef CAS IUCr Journals Google Scholar
Matsui, Y., Sakai, K., Murakami, M., Shiro, Y., Adachi, S., Okumura, H. & Kouyama, T. (2002). J. Mol. Biol. 324, 469–481. Web of Science CrossRef PubMed CAS Google Scholar
Mochizuki, M., Aoyama, H., Shinzawa-Itoh, K., Usui, T., Tsukihara, T. & Yoshikawa, S. (1999). J. Biol. Chem. 274, 33403–33411. Web of Science CrossRef PubMed CAS Google Scholar
Murshudov, G. N., Skubák, P., Lebedev, A. A., Pannu, N. S., Steiner, R. A., Nicholls, R. A., Winn, M. D., Long, F. & Vagin, A. A. (2011). Acta Cryst. D67, 355–367. Web of Science CrossRef CAS IUCr Journals Google Scholar
NIST (2004). NIST X-ray Mass Attenuation Coefficients, NIST Standard Reference Database 126. National Institute of Standards and Technology, Gaithersburg, MD, USA (doi:10.18434/T4D01F). Google Scholar
Owen, R. L., Pearson, A. R., Meents, A., Boehler, P., Thominet, V. & Schulze-Briese, C. (2009). J. Synchrotron Rad. 16, 173–182. Web of Science CrossRef CAS IUCr Journals Google Scholar
Owen, R. L., Rudiño-Piñera, E. & Garman, E. F. (2006). Proc. Natl Acad. Sci. 103, 4912–4917. Web of Science CrossRef PubMed CAS Google Scholar
Paithankar, K. S. & Garman, E. F. (2010). Acta Cryst. D66, 381–388. Web of Science CrossRef CAS IUCr Journals Google Scholar
Pearson, A. R., Pahl, R., Kovaleva, E. G., Davidson, V. L. & Wilmot, C. M. (2007). J. Synchrotron Rad. 14, 92–98. Web of Science CrossRef CAS IUCr Journals Google Scholar
Shimizu, N., Hirata, K., Hasegawa, K., Ueno, G. & Yamamoto, M. (2007). J. Synchrotron Rad. 14, 4–10. Web of Science CrossRef CAS IUCr Journals Google Scholar
Tsukihara, T., Aoyama, H., Yamashita, E., Tomizaki, T., Yamaguchi, H., Shinzawa-Itoh, K., Nakashima, R., Yaono, R. & Yoshikawa, S. (1995). Science, 269, 1069–1074. CrossRef CAS PubMed Web of Science Google Scholar
Wang, B. C. (1985). Methods Enzymol. 115, 90–112. CrossRef CAS PubMed Google Scholar
Weiss, M. S., Panjikar, S., Mueller-Dieckmann, C. & Tucker, P. A. (2005). J. Synchrotron Rad. 12, 304–309. Web of Science CrossRef CAS IUCr Journals Google Scholar
Wikström, M., Krab, K. & Sharma, V. (2018). Chem. Rev. 118, 2469–2490. Web of Science PubMed Google Scholar
Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., McNicholas, S. J., Murshudov, G. N., Pannu, N. S., Potterton, E. A., Powell, H. R., Read, R. J., Vagin, A. & Wilson, K. S. (2011). Acta Cryst. D67, 235–242. Web of Science CrossRef CAS IUCr Journals Google Scholar
Yoshikawa, S. & Shimada, A. (2015). Chem. Rev. 115, 1936–1989. Web of Science CrossRef CAS PubMed Google Scholar
Zeldin, O. B., Gerstel, M. & Garman, E. F. (2013). J. Appl. Cryst. 46, 1225–1230. Web of Science CrossRef CAS IUCr Journals Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.