view article

Figure 4
GUI for static solution scattering measurements. The fields in the top portion of the GUI are used for scaling factor adjustment and exclusion of outlier data (the first of the five data frames, or X-ray exposures, was excluded). The middle plots are used to verify the result of buffer subtraction, under the water peak and in the Guinier region. The analysis outputs from ATSAS are displayed in the text area and in the bottom plots. The example data shown here are collected from a lipid vesicle sample. The lipid chain–chain correlation peak near 1.5 Å−1 is clearly visible. This GUI is provided as part of the py4xs.notebooks module.