For the thermoelastically distorted M1 without any correction, the Strehl ratio calculated directly from the finite-element analysis (FEA) results (green bars) is in agreement with that calculated using wavefront propagation (red bars) for each of the five studied combinations of photon energy, polarization mode and undulator K (for example 620.7 eV, linear vertical polarization, K = 1.5). In each case the Strehl ratio can be increased (blue bars) by correcting the shape of the elliptical M3 to move the focus −7.5 mm at K = 1.5 and −5 mm at K = 2.5, where the negative sign indicates the upstream direction. Note that 1862 eV is outside the optimal range of the FLEXON beamline, but was included in these calculations for comparison of calculation methods.