view article

Figure 7
Simulation of the X-ray-induced heating calculated at the point of maximum temperature by considering the time pattern of the source. The predictions obtained with the explicit method for samples WBVB08, WBAP13 and WBAP14 are shown in (a), (b) and (c), respectively. Black lines represent the time-dependent studies and coloured lines show the corresponding transient behaviour in steady-state conditions, already shown in Fig. 5[link](e). Following the same sample order, in (d), (e) and (f) the corresponding simulations are compared with the those calculated with the implicit method (dashed lines).