view article

Figure 6
Calculated total external reflectivity of the combined mirrors M1–M3 for both reflecting coatings plotted on a log scale, inset on linear scale. Shown is the minimum energy cut-off using the B4C coating for all three mirrors and mirrors M1 and M2 at 3.6 mrad suitable to reduce third harmonic content, and the maximum energy cut-off using the Pt coating for all three mirrors and mirrors M1 and M2 at 1.7 mrad. Also shown is the typically used working point at 2 mrad using the B4C coating. In all cases the mirror M3 is set to its working point of 1.3 mrad.