Figure 10
Comparison of the experimental data and simulation results for (a) Al–Al, (b) Cu–Al and (c) Cu–Cu beamline filter configurations. The simulated results include the energy deposited from the direct interaction of the X-ray microbeam (red squares) and from optical photons generated by the barrier film (blue circles), which are then incident on the sensitive volume. Statistical uncertainties are defined as one standard deviation. |