actinide physics and chemistry
Size and structure of hexanuclear plutonium oxo-hydroxo clusters in aqueous solution from synchrotron analysis
aCEA, DES, ISEC, DMRC, Univ Montpellier, Marcoule, France, bICSM, CEA, Univ Montpellier, CNRS, ENSCM, Bagnols sur Cèze, France, and cSynchrotron SOLEIL, L'Orme des Merisiers Saint Aubin, BP 48, 91192 Gif-sur-Yvette Cedex, France
*Correspondence e-mail: thomas.dumas@cea.fr
The size and shape of a water-soluble hexanuclear plutonium cluster were probed by combining synchrotron small-angle X-ray scattering (SAXS) and extended X-ray absorption fine structure (EXAFS). A specific setup coupling both techniques and dedicated to radioactive samples on the MARS beamline endstation at Synchrotron SOLEIL is described. The plutonium hexanuclear cores are well stabilized by the 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid ligands and this allows a good evaluation of the setup to probe the very small plutonium core. The results show that, in spite of the constrained conditions required to avoid any risk of sample dispersion, the
and the sample environment are optimized to obtain a very good signal-to-noise ratio, allowing the detection of small plutonium aggregates in an aqueous phase. The structure of the well defined hexanuclear cluster has been confirmed by measurements in solution and correlated with SAXS data processing and modelling. An iterative comparison of classical fit models (Guinier or sphere form factor) with the experimental results allowed a better interpretation of the SAXS signal that will be relevant for future work under environmentally relevant conditions.1. Introduction
Because plutonium is highly radiotoxic, it represents one of the major long-term risks in nuclear waste management. To predict and control the behaviour of plutonium under various environmental conditions, thermodynamic models have been developed to describe plutonium solubility and surface interactions (Altmaier et al., 2013; Geckeis et al., 2013; Kersting et al., 1999). Nevertheless, new experimental inputs are still necessary in order to improve the reliability of these models. Among them, any additional fundamental knowledge of the complex plutonium chemistry at the molecular scale is highly desirable for the safety of long-term nuclear disposal.
In this scope, and within the large variety of plutonium chemical and redox states, hydrolyzed forms of tetravalent plutonium are crucial objects to consider. Due to its high charge density in aqueous solution, the Pu4+ ion has a high tendency for hydrolysis reactions and can further polymerize through oxolation and/or olation reactions. The intermediate clusters formed through these reactions can further condense to yield colloidal plutonium nanoparticles which might enhance its mobility (Dalodière et al., 2017; Gerber et al., 2020; Micheau et al., 2020; Neck et al., 2007; Walther et al., 2007; Walther & Denecke, 2013). Until now, the addition of complexing molecules was considered to limit the growth of these colloids, leading to smaller polynuclear species and affecting plutonium solubility in complexing humic acid conditions (Marsac et al., 2014). Even though analogous tetravalent cations can also form polynuclear clusters with different numbers of metallic cations M4+ in the nuclear core (Hennig et al., 2012, 2017; Knope et al., 2011; Takao et al., 2012), recent work has only characterized small polynuclear plutonium clusters.
Knope & Soderholm (2013) first revealed the formation of solid Li6[Pu6(OH)4O4(H2O)6(HGly)12]Cl18·10.5H2O, which consists of a mixed hydroxo/oxo plutonium(IV) hexanuclear cluster. More recently, Tamain et al. (2016, 2017) used visible spectroscopy and techniques to correlate solid-state and solution structures of another hexanuclear complex exhibiting the same [Pu6(OH)4O4]12+ core, stabilized with the polyamino carboxylic acid DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid). Visible absorption and reflectance spectra and extended X-ray absorption fine structure (EXAFS) measurements confirmed the stability of the hexanuclear core from the solid state to the solution. However, both spectroscopic approaches only provide plutonium-centred information and indicate that the plutonium hexanuclear core is preserved in solution.
To describe long-range interactions in solution, small-angle X-ray scattering (SAXS) was applied in combination with et al. (2018) to follow UIV hydrolysis, condensation and growth up to the formation of U-38 clusters. It was also applied to uranyl peroxo nanospheres (Falaise & Nyman, 2016; Dembowski et al., 2017; Zhang et al., 2019) and even to small hexanuclear uranium core clusters by Falaise et al. (2017).
in aqueous solution. SAXS offers a complementary image of the plutonium species in solution. This technique has already been used for the characterization of other actinide polynuclear compounds in solution. For instance, SAXS was used on U oxo-clusters by MartinRecently, SAXS measurements became available for plutonium samples on the MARS beamline and were used in combination with et al., 2020). Although the molecular structure of the hexanuclear DOTA plutonium clusters is well identified by single-crystal X-ray diffraction (XRD) and the ability of the MARS beamline to perform SAXS measurements on plutonium colloids was previously demonstrated, the present work takes the opportunity to probe the more challenging hexanuclear core clusters of plutonium in aqueous solution. The idea of probing the small hexanuclear cluster core of plutonium was twofold: (i) to assign as a test the ability of this setup to detect small and dilute objects in aqueous solution and propose a more detailed description of the setup, and (ii) to provide information on the external shape of hexanuclear plutonium clusters in solution, that were previously only defined by the first two coordination shells of the plutonium atom.
to study plutonium colloids (Micheau2. Materials and methods
2.1. Synthesis of the [Pu6(OH)4O4(H2O)8(HDOTA)4] cluster
The plutonium DOTA hexanuclear cluster was synthesized as previously reported (Tamain et al., 2016). Protonated DOTA (47 mg) was dissolved in water (400 µl) with heating and 1 M HNO3 (80 µl) was added after complete dissolution of the ligand. The plutonium solution was added to the ligand solution ([Pu]/[L] = 1/5). The mixture was left overnight to give crystals of plutonium(IV) hexamer.
The SAXS sample was prepared by dissolution of these crystals (2.3 mg) in 400 µL 1 M HNO3. The sample purity and concentration of 0.01 M (concentration of Pu involved in the hexamer) were checked using UV–Vis absorption spectroscopy in the visible range (400–800 nm) (Fig. 1). The spectrum collected in the visible range is identical to that reported previously and confirms the sample purity. The slight baseline deviation observed below 600 nm is related to a variation in HNO3 concentration between the two samples.
2.2. Measurement by synchrotron radiation and experimental setup
In this section, we give a brief summary of the design and relevant characteristics of the Multi Analyses on Radioactive Samples (MARS) beamline at Synchrotron SOLEIL (Saint-Aubin, France) (LLorens et al., 2014; Sitaud et al., 2012), as well as presenting more specific developments making the beamline especially suitable for scattering experiments.
From its inception, MARS was designed to accommodate the wide-ranging scientific requirements of the radionuclide and actinide sciences (up to highly radioactive materials) covering areas from biology and environmental science through to advanced materials for the direct characterization of their chemistry and microstructure with the use of synchrotron-based techniques. The beamline is licenced to receive samples with radioisotope activities up to two million times their isotope-specific European exemption limits and complies with all legal requirements and safety precautions to avoid contaminating aerosol dissemination and guarantee the public dose rate outside the beamline. It has successfully shown its flexibility by accommodating a wide array of diverse sample environments during its years of operation (Béchade et al., 2012; Menut et al., 2015; Béchade et al., 2013; LLorens et al., 2014; Dumas et al., 2018; Bengio et al., 2020).
X-rays are sourced from a 1.71 T bending magnet providing a continuous spectrum of photons with a Q range achievable may be adapted.
of 8.6 keV. A double-crystal monochromator (DCM) (Oxford Danfysik, Oxford, UK) allows tunable monochromatization in the continuous energy range from 3.5 to 35 keV and horizontal focusing with a sagittal bender. The original feature of this DCM is its ability to exchange Si(111) and Si(220) crystal sets under vacuum to optimize the and energy resolution over the energy range. Two long mirrors are inserted before and after the DCM for high-energy harmonics rejection and to provide a vertically collimated and focused beam. These mirrors consist of silicon blocks with two different reflective surfaces: a 60 mm width silicon uncoated strip for energy setups below 14 keV and a 50 mm width platinum-coated strip (thickness 60 nm) for high energies. The X-ray beam at the second endstation of the MARS beamline (CX3), where the scattering and absorption measurements described here were performed, can be focused down to a spot size of 300 µm × 150 µm [full width at half-maximum (FWHM), horizontal (H) × vertical (V)], with the possibility of further microfocusing the beam down to 15 µm × 15 µm on the second endstation in the reduced range between 3.5 and 21 keV by inserting additional rhodium-coated mirrors in the Kirkpatrick–Baez geometry. Two kinds of two-dimensional detectors (image plate or hybrid pixel) are available for the scattering and/or diffraction analyses, which can be moved along the X-ray axis. Thus, depending on the energy used and the exact geometry of the scattering setup, theAs SAXS is contingent on the accurate subtraction of all background scattering contributions (optical elements, windows, slits, air etc.), reducing the effects of parasitic scattering is vital, not only to improve signal-to-noise ratios in the data but also to remove sources of scattering that may perturb the extraction of structural parameters. The instrument background on MARS was reduced by a standard three-paired-slits collimator system, where the first slits define the beam and adjust the the second slits cut out the parasitic scattering fan coming from the optics and passing through the first pair of slits, and the third and last pair of slits remove the weaker secondary scattering produced by the second pair of slits. To reduce this background further, the third slits are set up with hybrid scattering slits from Xenocs (Sassenage, France). These scatterless slits are composed of heavy metal blades with Ge monocrystal lateral edges oriented far from any Bragg peak position with respect to the incident beam. Based on comparison of the energy-dependent attenuation lengths of Ge, it actually offers the best attenuation of energies above 12 keV for synchrotron-based SAXS instruments where they could yield even higher performance enhancements with the incident beam intensity (Li et al., 2008). Extendable vacuum pipes sealed with Kapton windows are attached to the beamline to minimize the air gap around the sample position to a few centimetres and to keep the background scattering from air to a minimum, aided by motorized (Tx, Tz) sample stages with 1 µm resolution over a 100 mm range of motion. As radiation damage to samples, especially for solutions, may result in the formation of aggregates that can cause significant problems at a high-brilliance synchrotron source, the MARS beamline is equipped with a beam attenuator composed of eight pneumatic holders for aluminium foils of 0.05 to 8.0 mm thickness, allowing fine tuning of the beam attenuation to achieve the optimal balance between lowering the useful signal and reducing the effects of radiation damage.
Finally, a crucial step in SAXS data processing is the subtraction of the sample environment scattering from that of the sample, and these two independent patterns must be appropriately normalized to consider possible variation in the beam Tx, Tz) stages. The `integration' detector is a MAR-Research system with a sensitive phosphor imaging surface diameter of 345 mm (Fig. 2).
and differences in transmission. This operation can be conveniently accomplished by using an active beamstop. A miniature 3 mm × 2 mm active beamstop using a pin diode has been developed internally at SOLEIL. The beamstop has been shaped by additive manufacturing by tungsten laser powder bed fusion that made it possible to produce this complex functional component in a resource-efficient and economical manner. The beamstop is installed in the He-flushed flight tube which ends in a 345 mm-diameter Kapton window at the SAXS detector. The flight tube is positioned in the beam by motorized (Combined SAXS and K-edge, corresponding to 17.038 keV. The focused beam size on the sample was 300 µm × 400 µm (Fig. 2). A specific cell was used for radioactive samples and was composed of Teflon sample holders containing three slots of 250 µl closed by two layers of Kapton film (polyimide) on each side.
analyses were performed with the storage ring operating in top-up mode at an electron current of 500 mA, 2.5 GeV. Beam energy calibration was performed at the yttrium2.3. SAXS
SAXS experiments were carried out using the 2D image-plate detector (MAR345, marXperts GmbH, Germany), with an X-ray energy of 17 keV corresponding to an average wavelength of 0.7294 Å−1 and a sample-to-detector distance of 785.70 mm. The angular axis was calibrated using the powder diffraction pattern of silver behenate. This configuration allows coverage of a Q range between about 0.1 and 18.8 nm−1. Sample transmissions were recorded for 10 s using photodiodes and scattering diagrams were recorded for 5 s per sample. Isotropic 2D scattering data were azimuthally averaged to obtain the scattering intensity I(Q) using the Fit2D software (Hammersley et al., 1996). The sample scattering intensity was then normalized by the acquisition time, transmission and thickness, and multiplied by a normalization constant determined with the help of the scattering intensity of polyethylene (PE) at Q = 0.36 nm−1 that corresponds to 4.9 cm−1. Finally, the absolute intensity scattered by the cluster was obtained by subtracting the empty cell, solvent and background contributions. Data were simulated using the SasView 4.2.0 software (http://www.sasview.org) especially for core–shell, lamella and disc form factors.
2.4. Pu L3-edge XAS
Experimental spectra were recorded in fluorescence mode using a Ge multi-element detector (ORTEC, Oak Ridge, Tennessee, USA) at the Pu L3-edge. The samples were oriented at 45° with respect to the incident beam. The incident energy was calibrated using a metallic Zr foil (K-edge defined at 17.988 keV). The Pu was defined at the maximum of the white line and corresponds to 18.068 keV. The spectrum corresponds to the average of six pre-processing scans obtained after 60 min of analysis each. data were analysed with the Athena and Arthemis software from the IFEFFIT package (Ravel & Newville, 2005). Data fitting was performed using a Keiser–Bessel window with a cluster size of 1–5 Å for the Fourier transform (FT) in the 2 < k < 14 Å range [Feff, Version 8.4 (Ankudinov et al., 1998)]. Two parameters were fitted, the atomic distances (R) and the Debye–Waller factor (DWF). Coordination numbers were fixed to the value.
3. Results
The SAXS data processing operations performed on the signal acquired from the plutonium cluster are summarized in Fig. 3. The raw data curves in Fig. 3(a) correspond to the signal obtained from the sample and an empty cell as reference. Both diagrams exhibit a well defined peak at 4 nm−1 which is attributed to the scattering of the four Kapton layers on the sample cell. This peak is still visible after subtraction of the empty cell, as can be seen in Fig. 3(b) where the pure solvent and the sample are compared after normalization of the data according to the sample thickness, transmission, acquisition time and scattering intensity of polyethylene (PE) used as reference. The residual presence of the Kapton peak can be attributed to the non-reproducible handmade cell and to the impossibility of measuring the exact empty cell used for the radioactive sample. Nevertheless, both diagrams demonstrate a significant scattering difference when comparing the hexanuclear cluster and the solvent, particularly around 100 nm−1. The absolute intensity scattered by the cluster is shown in Fig. 3(c) after subtracting the solvent contribution while considering the total conversion of PuIV into DOTA polyamino carboxylate PuO2 clusters (corresponding to a of 0.018). Note that a subtraction artefact related to the Kapton is still visible at 4 nm−1. Small intensity variations are also observed at low Q. This can be attributed to a subtraction artefact due to the low scattering intensity of such dilute samples, or to a linked to cluster interaction or aggregation. Further investigations at higher concentrations are planned in order to investigate this diagram region. Nevertheless, the normalized SAXS diagram of the plutonium clusters [Fig. 3(c)] in absolute units can be fitted using simple models. This diagram displays a Q0 slope at low wavevectors and tends to a Q−4 slope at higher wavevectors, which behaviour is a typical signature of three-dimensional and compact objects with a sharp interface.
The scattering intensity is generally described as the product between an initial intensity I0 (when Q tends to 0), a form factor P(Q) relative to the shape of the solute, and a S(Q) related to the interaction between solutes (Glatter & Kratky, 1982). To a first approximation, and considering a very S(Q) is considered equal to 1. Two approaches were employed in the 1–6 nm−1 Q range to determine the size of the plutonium clusters: (i) Guinier analysis and (ii) a monodisperse sphere form factor fitting [Fig. 3(c)]. In these two models, the initial intensity I0 is defined as
with the summarizes the scattering length density ρc and the contrast Δρ2 used for the calculations.
of the clusters, the volume of one cluster and the scattering length density contrast with the solvent. Table 1
|
The Guinier analysis gives a first estimation of the cluster Rg. A of around 0.48 nm is found. Considering spherical and filled entities, the radius of the cluster can be deduced with the following equation [equation (2)], where R is the radius of the sphere. This leads to a sphere radius of 0.62 nm (cf. 1.22 nm diameter).
The best fit obtained with the monodisperse sphere form factor model is consistent with a sphere radius R of about 0.62 nm, which is in full agreement with the results obtained with the Guinier analysis. The fitting parameters are summarized in Table 2.
|
Finally, both models concur in the description of the cluster as nearly spherical particles measuring 1.2 nm in diameter in nitric acid solution. The size probed with the SAXS approach using a monodisperse sphere form factor may be compared with the one expected from the crystallographic data of the plutonium hexanuclear clusters (Tamain et al., 2016). The [Pu6(OH)4O4(H2O)8(HDOTA)4] complex is made of a [Pu6(OH)4O4]12+ core decorated with four DOTA polyamino carboxylate ligands, which forms an oblate spheroid with a 0.45 nm radius in the axial direction and 0.8 nm radius in the equatorial direction (Fig. 4). Indeed, the value obtained using a sphere form factor of 0.62 is intermediate between the two values and appears to be a good geometric approximation. A more accurate approximation of the overall cluster shape in solution would involve more sophisticated geometry and electron contrast models. However, in this experiment, the experimental SAXS signal does not allow such a precise description. With a better normalization that suffers less from the sample holder scattering signal, this limit may be overcome with an optimized setup in future work.
Previous k3-weighted oscillations and the corresponding FT acquired from this experiment are presented in Fig. 5. The overall shape of the FT is consistent with previous measurements made on similar samples. Low-frequency contributions at k < 7 Å−1 correspond to the plutonium–oxygen coordination sphere (1 Å < R+ϕ < 2 Å in the FT). High-frequency oscillations at k > 7 Å−1 are dominated by a heavy backscatterer which shows a plutonium polynuclear species. An intermediate contribution observed between R+ϕ = 2.2 and 3.2 Å in the FT originates from carboxylate carbon atoms.
measurements carried out on the plutonium solution demonstrated the existence of the plutonium cluster as a soluble species. The clusters are made of six plutonium centres that form an octahedron, which are connected by oxo and hydroxo bonds alternating on each face of the octahedron and carboxylate functions that bond along the octahedron edges. TheThe best fit spectra (red lines in Fig. 5, and data in Table 3) were obtained using the already published (Tamain et al., 2016) and are in excellent agreement with the experimental data. In the fitting procedure, distances, DWFs, the amplitude reduction factor ( #!S0 2) and the energy shift (E0) were refined while the coordination numbers were fixed according to the In agreement with the latter, the first actinide coordination shell is well reproduced by two distinct Pu–O subshells. The first one corresponds to two capping μ3-O2− oxygen atoms at a distance of 2.18 Å (±−0.01 Å). The second Pu–O subshell at 2.40 Å contains the other six Pu—O distances (μ3-OH−, water molecules and O from carboxylate functions). As this subshell contains different types of bonds and distances, the DWF is large (0.008 Å2) compared with the short oxygen shell (0.004 Å2).
|
Considering the hexanuclear cluster geometry, the Pu—Pu signal splits into two shells. The edge-sharing shell consists of four Pu—Pu scattering paths with a 3.77 Å bond length. A longer bond corresponds to the opposite Pu atoms in the octahedron at 5.31 Å. Overall, all parameters are fully consistent with previous reports on this type of hexanuclear complex and agree well with the crystallographic structure.
4. Conclusions
The characterization of the PuIV hexanuclear cluster using synchrotron SAXS coupled with undertakes an analytical challenge to describe the actinide coordination mode and structure in These species are of great interest for obvious environmental reasons and require a thorough characterization and speciation. Spectroscopic techniques and crystallographic characterization initially paved the way in this sense. In this experiment, we have extended our knowledge of these compounds by combining synchrotron X-ray scattering and absorption techniques. The synthesis of the hexanuclear cluster was controlled by UV–Vis–NIR spectroscopy and the analyses were fully consistent with previous results. The SAXS results identify 1.2 nm-diameter spherical particles, in good agreement with the shape of the [Pu6(OH)4O4(H2O)8(HDOTA)4] complex described previously by single-crystal XRD.
The instrumental setup fulfils the expectations of users for measuring highly radioactive samples in environmentally relevant dilute conditions, even for weakly scattering clusters. Nevertheless, the instrument is being developed further. Thus, the MARS beamline is equipped with a Pilatus 3 2M (Dectris, Switzerland) hybrid photon-counting pixel detector having practically no detector readout noise, a high Tx, Ts, Rx) motorized support to form camera lengths anywhere from 0.35 to 3 m in 0.25 m steps. On the SAXS camera nose cone, a second detector affording partial 2D access to wide-angle X-ray scattering (WAXS) information will be operated to complement full 2D SAXS in the appropriate configuration. With careful beamline setup, these detectors allow overlap of the reduced 1D SAXS and WAXS data over the full camera length capability of the beamline. Thus, any reasonably sized sample environment can be accommodated whilst minimizing air gaps and attendant background scatter. To capitalize on the energy tunability of the beamline, anomalous SAXS might be exploited to probe changes in the scattering properties of selected atoms to gain information on the distribution of the resonant atoms within the sample.
and a short readout time. It is mounted on a new (Acknowledgements
We gratefully acknowledge Hervé Hermange for his fruitful assistance in the mechanical design and integration of the active beamstop and fitting of the SAXS setup on the CX3 end-station of the MARS beamline, and Philippe Moisy, Sergei Nikitenko and Philippe Guilbaud for fruitful discussions.
Funding information
This work was supported by the CEA through the chemistry research programme (RCHIM) from the cross-cutting basic research programme (RTA). We acknowledge the financial support of the Cross-Disciplinary Program on bottom up exploratory research program of CEA, the French Alternative Energies and Atomic Energy Commission.
References
Altmaier, M., Gaona, X. & Fanghänel, T. (2013). Chem. Rev. 113, 901–943. Web of Science CrossRef CAS PubMed Google Scholar
Ankudinov, A. L., Ravel, B., Rehr, J. J. & Conradson, S. D. (1998). Phys. Rev. B, 58, 7565–7576. Web of Science CrossRef CAS Google Scholar
Béchade, J. L., Menut, D., Doriot, S., Schlutig, S. & Sitaud, B. (2013). J. Nucl. Mater. 437, 365–372. Google Scholar
Béchade, J. L., Menut, D., Lescoat, M. L., Sitaud, B., Schlutig, S., Solari, P. L., Llorens, I., Hermange, H., de Carlan, Y., Ribis, J. & Toualbi, L. (2012). J. Nucl. Mater. 428, 183–191. Google Scholar
Bengio, D., Dumas, T., Arpigny, S., Husar, R., Mendes, E., Solari, P. L., Schlegel, M. L., Schlegel, D., Pellet–Rostaing, S. & Moisy, P. (2020). Chem. Eur. J. 26, 14385–14396. Web of Science CrossRef CAS PubMed Google Scholar
Dalodière, E., Virot, M., Morosini, V., Chave, T., Dumas, T., Hennig, C., Wiss, T., Blanco, O. D., Shuh, D. K., Tyliszcak, T., Venault, L., Moisy, P. & Nikitenko, S. I. (2017). Sci. Rep. 7, 43514. Web of Science PubMed Google Scholar
Dembowski, M., Colla, C. A., Yu, P., Qiu, J., Szymanowski, J. E. S., Casey, W. H. & Burns, P. C. (2017). Inorg. Chem. 56, 9602–9608. Web of Science CrossRef CAS PubMed Google Scholar
Dumas, T., Guigue, M., Moisy, P., Colina-Ruiz, R., de Leon, J. M., Matara-Aho, M., Solari, P. L., Monfort, M., Moulin, C., Beccia, M. R. & Den Auwer, C. (2018). Chemistryselect, 3, 2021–2024. Web of Science CrossRef CAS Google Scholar
Falaise, C., Neal, H. A. & Nyman, M. (2017). Inorg. Chem. 56, 6591–6598. Web of Science CSD CrossRef CAS PubMed Google Scholar
Falaise, C. & Nyman, M. (2016). Chem. Eur. J. 22, 14678–14687. Web of Science CrossRef CAS PubMed Google Scholar
Geckeis, H., Lützenkirchen, J., Polly, R., Rabung, T. & Schmidt, M. (2013). Chem. Rev. 113, 1016–1062. Web of Science CrossRef CAS PubMed Google Scholar
Gerber, E., Romanchuk, A. Y., Pidchenko, I., Amidani, L., Rossberg, A., Hennig, C., Vaughan, G. B. M., Trigub, A., Egorova, T., Bauters, S., Plakhova, T., Hunault, M. O. J. Y., Weiss, S., Butorin, S. M., Scheinost, A. C., Kalmykov, S. N. & Kvashnina, K. O. (2020). Nanoscale, 12, 18039–18048. Web of Science CrossRef CAS PubMed Google Scholar
Glatter, O. & Kratky, O. (1982). Small-Angle X-ray Scattering. New York: Academic Press. Google Scholar
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N. & Hausermann, D. (1996). High Press. Res. 14, 235–248. CrossRef Web of Science Google Scholar
Hennig, C., Takao, S., Takao, K., Weiss, S., Kraus, W., Emmerling, F. & Scheinost, A. C. (2012). Dalton Trans. 41, 12818–12823. Web of Science CSD CrossRef CAS PubMed Google Scholar
Hennig, C., Weiss, S., Kraus, W., Kretzschmar, J. & Scheinost, A. C. (2017). Inorg. Chem. 56, 2473–2480. Web of Science CSD CrossRef CAS PubMed Google Scholar
Kersting, A. B., Efurd, D. W., Finnegan, D. L., Rokop, D. J., Smith, D. K. & Thompson, J. L. (1999). Nature, 397, 56–59. Web of Science CrossRef CAS Google Scholar
Knope, K. E. & Soderholm, L. (2013). Inorg. Chem. 52, 6770–6772. Web of Science CSD CrossRef ICSD CAS PubMed Google Scholar
Knope, K. E., Wilson, R. E., Vasiliu, M., Dixon, D. A. & Soderholm, L. (2011). Inorg. Chem. 50, 9696–9704. Web of Science CSD CrossRef ICSD CAS PubMed Google Scholar
Li, Y., Beck, R., Huang, T., Choi, M. C. & Divinagracia, M. (2008). J. Appl. Cryst. 41, 1134–1139. Web of Science CrossRef CAS IUCr Journals Google Scholar
LLorens, I., Solari, P. L., Sitaud, B., Bes, R., Cammelli, S., Hermange, H., Othmane, G., Safi, S., Moisy, P., Wahu, S., Bresson, C., Schlegel, M. L., Menut, D., Bechade, J. L., Martin, P., Hazemann, J. L., Proux, O. & Den Auwer, C. (2014). Radiochim. Acta, 102, 957–972. Web of Science CrossRef CAS Google Scholar
Marsac, R., Banik, N. L., Marquardt, C. M. & Kratz, J. V. (2014). Geochim. Cosmochim. Acta, 131, 290–300. Web of Science CrossRef CAS Google Scholar
Martin, N. P., Volkringer, C., Henry, N., Trivelli, X., Stoclet, G., Ikeda-Ohno, A. & Loiseau, T. (2018). Chem. Sci. 9, 5021–5032. Web of Science CSD CrossRef CAS PubMed Google Scholar
Menut, D., Béchade, J. L., Cammelli, S., Schlutig, S., Sitaud, B. & Solari, P. L. (2015). J. Mater. Res. 30, 1392–1402. Web of Science CrossRef CAS Google Scholar
Micheau, C., Virot, M., Dourdain, S., Dumas, T., Menut, D., Solari, P. L., Venault, L., Diat, O., Moisy, P. & Nikitenko, S. I. (2020). Environ. Sci. Nano, 7, 2252–2266. Web of Science CrossRef CAS Google Scholar
Neck, V., Altmaier, M., Seibert, A., Yun, J. I., Marquardt, C. M. & Fanghänel, T. (2007). Radiochim. Acta, 95, 193–207. Web of Science CrossRef CAS Google Scholar
Ravel, B. & Newville, M. (2005). J. Synchrotron Rad. 12, 537–541. Web of Science CrossRef CAS IUCr Journals Google Scholar
Sitaud, B., Solari, P. L., Schlutig, S., Llorens, I. & Hermange, H. (2012). J. Nucl. Mater. 425, 238–243. Web of Science CrossRef CAS Google Scholar
Takao, K., Takao, S., Scheinost, A. C., Bernhard, G. & Hennig, C. (2012). Inorg. Chem. 51, 1336–1344. Web of Science CrossRef CAS PubMed Google Scholar
Tamain, C., Dumas, T., Guillaumont, D., Hennig, C. & Guilbaud, P. (2016). Eur. J. Inorg. Chem. 2016, 3536–3540. Web of Science CSD CrossRef CAS Google Scholar
Tamain, C., Dumas, T., Hennig, C. & Guilbaud, P. (2017). Chem. Eur. J. 23, 6864–6875. Web of Science CSD CrossRef CAS PubMed Google Scholar
Walther, C., Cho, H. R., Marquardt, C. M., Neck, V., Seibert, A., Yun, J. I. & Fanghänel, T. (2007). Radiochim. Acta, 95, 7–16. Web of Science CrossRef CAS Google Scholar
Walther, C. & Denecke, M. A. (2013). Chem. Rev. 113, 995–1015. Web of Science CrossRef CAS PubMed Google Scholar
Zhang, J. Q., Tian, Q., Li, Q. T., Henderson, M. J., Tuo, X. G., Yan, M. H. & Almásy, L. (2019). J. Mol. Liq. 296, 111794. Web of Science CrossRef Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.