research papers
High-speed free-run ptychography at the Australian Synchrotron
aCentral Analytical Research Facility, Queensland University of Technology, Brisbane, Queensland 4000, Australia, bDepartment of Chemistry and Physics, La Trobe Institute for Molecular Science, La Trobe University, Bundoora, Victoria 3086, Australia, cMelbourne Centre for Nanofabrication, Clayton, Victoria 3168, Australia, dDepartment of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, United Kingdom, eSchool of Earth and Atmospheric Sciences, Faculty of Science, Queensland University of Technology, Brisbane, Queensland 4000, Australia, and fAustralian Nuclear Science and Technology Organisation, Australian Synchrotron, Clayton, Victoria 3168, Australia
*Correspondence e-mail: cameronk@ansto.gov.au
Over the last decade ptychography has progressed rapidly from a specialist ultramicroscopy technique into a mature method accessible to non-expert users. However, to improve scientific value ptychography data must reconstruct reliably, with high image quality and at no cost to other correlative methods. Presented here is the implementation of high-speed ptychography used at the Australian Synchrotron on the XFM beamline, which includes a free-run data collection mode where 2 at up to 140 µm2 s−1, with 13× spatial resolution enhancement compared with the beam size. With these improvements, ptychography at velocities up to 250 µm s−1 is approaching speeds compatible with fast-scanning microscopy. The combination of these methods provides morphological context for elemental and chemical information, enabling unique scientific outcomes.
is eliminated and the scan time is optimized. It is shown that free-run data collection is viable for fast and high-quality ptychography by demonstrating extremely high data rate acquisition covering areas up to 352 000 µmKeywords: ptychography; scanning X-ray diffraction microscopy; coherent diffractive imaging; ultramicroscopy; phase-contrast imaging.
1. Introduction
Scanning X-ray diffraction microscopy (SXDM), a modern version of ptychography (Hegerl & Hoppe, 1970), is a high-resolution high-sensitivity scanning coherent diffractive imaging method. Phase and absorption images of the object, projections of the complex X-ray are recovered through an iterative reconstruction algorithm (Faulkner & Rodenburg, 2004; Thibault et al., 2008). In recent years, the development of SXDM has matured to deliver scientific outcomes (e.g. Kourousias et al., 2018; Jones et al., 2019; Genoud et al., 2020; Schrank et al., 2021), particularly in the context of 3D nanostructure analysis (e.g. Chen et al., 2013; Trtik et al., 2013; Bø Fløystad et al., 2015; Ciani et al., 2018). The simultaneous application of SXDM with microscopy (XFM) (Vine et al., 2012; Deng, Vine et al., 2015; Jones et al., 2016) provides super-resolution ultrastructural context for the fluorescence data. Key developments enabling correlated high-throughput SXDM-XFM are the development of fly-scanning SXDM data collection (Clark et al., 2014; Pelz et al., 2014; Huang et al., 2015; Deng, Nashed et al., 2015) and mixed-state reconstruction (Thibault & Menzel, 2013), which accounts for partial coherence of the beam and object motion during acquisition. These developments, inter alia, have allowed ptychographic imaging to be achieved with unprecedented scan areas and data collection rates. Examples include a nematode imaged in a scan area of 82 000 µm2 at 6.4 µm2 s−1 (Jones et al., 2019), an integrated circuit imaged in optimized step-scan mode over 145 000 µm2 at 34.5 µm2 s−1 (Guizar-Sicairos et al., 2014) and an integrated circuit imaged with a double-multilayer monochromator (DMM) over 9 µm2 in 1.2 s (Deng et al., 2019). The advent of diffraction-limited storage rings with increased coherent and broadband ptychography algorithms that can exploit DMMs (Enders et al., 2014; Yao et al., 2021) provides opportunities (Thibault et al., 2014) for further gains in data collection rates, with prospects of obtaining nanoscale images of macroscopic specimens (Du et al., 2021).
X-ray microprobes are moving towards event-mode data streams. One common approach is to use a spatially delimited event stream, where image-space pixel boundaries are used to delimit the continuous arrival of a stream of fluorescence photons, to record and reset counters, etc. The Maia detector system (Ryan et al., 2018) was one of the first to adopt this approach, collecting a stream of event-mode data and eliminating per-pixel readout overheads, facilitating XFM imaging in the megapixels-per-hour regime (Howard et al., 2020). A second approach uses a rapid time-based sampling of spatial locations to delimit the stream of recorded events (Deng et al., 2019). This article reports a retrofit of an SXDM measurement system onto an existing microprobe that uses a spatially delimited event-mode triggering system.
One of the fundamental challenges of combining a spatially delimited system with a timed exposure detector, such as a pixel array detector typical for SXDM, is the mismatch of units: space converts directly to time only when velocity is constant. In essence, velocity variations can result in a race condition between the end of an SXDM exposure and the arrival of the next pixel boundary. The result is that, at best, the detector ignores the trigger received while acquiring, finishes the acquisition of the current frame and then waits until the next trigger from the subsequent scan point, resulting in a missed frame. At worst, depending on the detector electronics, the arrival of a trigger during acquisition may result in an error state, aborting the scan. To avoid this race condition, a per-pixel safety margin in the form of scan or detector et al., 2016). Here we propose an alternative where triggering is avoided altogether by allowing the detector to acquire images continuously.
is introduced to ensure a trigger is not issued before the detector is ready (Jones2. Implementation
On the Australian Synchrotron XFM beamline, we have implemented SXDM using a detector-driven free-run data collection method, where the detector internally triggers exposures according to a configured sequence. An EIGER2 X 1M (Dectris Ltd) hybrid photon-counting detector has been provided through a collaboration between La Trobe University and ANSTO. This detector retriggers with practically no (0.1 µs, <0.02%)
between the end of an exposure and the beginning of the next, meaning that all photons delivered to the sample contribute to the final image. The rising edge of an `acquisition in progress' logic signal is recorded as a frame event into the Maia data stream, tagged with a stage event containing the current position of the sample stage 20 nm encoders. A time stamp is not required since the frame event is associated with position only. The continuous nature of the data acquisition permits estimation of the centre of the sample motion kernel during each SXDM frame exposure by linear interpolation of the stage events.In free-run data collection mode the race condition between sample scan-point arrival time and detector framing completion is eliminated. Furthermore, the frame rate can be varied independently from the XFM pixel dwell time, allowing, for example, a significantly higher sampling rate in the fast scan direction than on the slow axis, which has been shown to be beneficial for fly-scanning SXDM (Pelz et al., 2014). Here, we demonstrate free-run SXDM data collection at scan velocities up to 250 µm s−1 and compare the reconstructed results with fly-scanning SXDM using position-based external triggering at each scan point. We apply simultaneous free-run SXDM-XFM imaging to a freestanding thin section of a rock sample featuring the interface between shale and a quartz–calcite vein. The results show that large-area high-resolution imaging provides inherently correlated nanoscale structural context for elemental mapping, providing unique scientific insights that cannot be realized with either method independently.
3. Data analysis pipeline
A Python data analysis pipeline was implemented on the XFM beamline to streamline SXDM data processing. Detector frames are stored as bitshuffle-LZ4 (ESRF Data Analysis Unit; hdf5plugin for Python, https://pypi.org/project/hdf5plugin/) compressed HDF5 data in the detector control unit RAM. Data files containing N frames are automatically transferred to the beamline file server as the files become available. The files are sorted, based on sample identification and scan number, into an iteratively traversable folder structure. A cluster of compute nodes on the beamline, having 240 CPU cores and 2.3 TB RAM, produces near real-time scanning transmission X-ray microscopy (STXM) images (Menzel et al., 2010). That is, transmission, darkfield and differential phase-contrast images (Fig. 1), which are used for immediate feedback on targeting and data quality to guide experiment progress.
The data analysis pipeline further pre-processes and packages the HDF5 data and relevant beamline metadata for SXDM reconstruction. The frame and stage events are extracted from the Maia data stream. SXDM data are corrected by a predefined valid pixel mask and the beam centre is automatically located from the sum of the frames in the first data file. Then, a region of interest (ROI) of M2 pixels surrounding the beam centre is extracted, where M is usually between 128 and 512 depending upon the required reconstruction pixel size. SXDM reconstructions are then typically carried out on the beamline cluster using a mixed-states difference-map and maximum-likelihood-based approach (Thibault et al., 2008; Thibault & Guizar-Sicairos, 2012; Thibault & Menzel, 2013; Enders & Thibault, 2016). However, in the present work, SXDM data were cropped to M2 = 2562 pixels and reconstructed with the ePIE algorithm (Maiden & Rodenburg, 2009) for 2000 iterations using ten orthogonal probe modes in a parallel GPU-enabled environment (Nashed et al., 2014), yielding reconstructed images with a pixel size of 24.5 nm.
4. Experimental method
The XFM beamline geometry has been described previously (Howard et al., 2020). The double-crystal monochromator selected 10 keV radiation from the undulator spectrum. With the white-beam slits in a typical XFM configuration, opened to 1.1 mm horizontal (h) × 0.2 mm vertical (v), and the position and intensity of the beam at the secondary source aperture maintained by a PID controller monitoring feedback from a quad-diode beam-position monitor, the beam was focused to approximately 2 µm (h) × 2 µm (v) full width at half-maximum (FWHM) by the Kirkpatrick–Baez mirrors. The beam-positioning feedback was then turned off during all SXDM measurements to avoid movements of the upstream optics that may affect the probe during scanning. A coherent portion of the beam was selected by closing the white-beam slits to 0.1 mm × 0.1 mm and the secondary source aperture (SSA) was set to 0.008 mm × 0.2 mm, where the horizontal size is used to control the beam intensity to avoid saturating the detectors. This reduced the beam size at the focal plane to around 350 nm × 550 nm FWHM and the beam intensity by a factor of around 40. The Maia fluorescence detector was in its usual backscatter geometry and collected fluorescence photons, which were processed using GeoPIXE (Ryan & Jamieson, 1993; Ryan et al., 2015). The EIGER2 SXDM detector, a fast-framing array of 1028 × 1060 75 µm wide pixels, was located 3.88 m downstream of the focus. A resolution test pattern made from two layers of 450 nm Au and 60 nm Cr was scanned downstream of the focal plane. Defocus is used to tune the beam (or probe) size on the sample. In this case the sample was scanned at 4 mm defocus where the probe was around 2 µm wide. Continuous-motion fly scanning is carried out using a raster-scanning motion sequence (RASCAN) which pre-calculates a bidirectional scan path to cover the scan area with optimized time and precision at the requested scan velocity and scan line separation (Afshar et al., 2017). As the sample approaches the end of the scan line, the non-scanning axis begins to accelerate to the next scan line, achieving a parabolic turnaround just outside of the defined scan region, minimizing both the scan line transition time and the total scan time.
Fig. 1 shows an STXM image of the test pattern, scanned in the focal plane with 0.1 µm over a 50 µm × 50 µm scan area, where panel (a) shows transmission, (b) shows darkfield on a logarithmic intensity scale, and (c) shows horizontal and (d) vertical differential phase contrast. The brightest areas in Fig. 1(b) represent the strongest scattering from features within the beam at each scan position. Overview STXM scans were obtained for targeting purposes with a 1 µm over large areas, e.g. 0.5 mm × 0.5 mm, with a 1000 Hz frame rate, taking under 5 min per scan and yielding of the order of 275 000 frames. The data analysis pipeline distributes these data to the cluster and obtains STXM images from such a dataset in 1.5 min. ROIs were chosen from darkfield images for high-resolution SXDM scanning.
A baseline comparison of position-based externally triggered (ET) and free-run (FR) data collection modes was carried out. The sample was scanned in both modes with 100 nm sampling intervals in both the horizontal and vertical directions at a scan velocity of 5 µm s−1 at a frame rate of 50 Hz, i.e. 20 ms exposure per frame, yielding a data collection rate of 0.49 µm2 s−1. For ET data collection, the frame exposure time was set to 0.99 times the expected XFM dwell (pixel transit) time. This exposure time was chosen to provide a 1% safety margin to avoid the race condition described above while having approximately the same number of photons per frame as the FR scan.
Scan speed tests were carried out on a second test pattern of similar composition at 100 nm and 500 nm sampling intervals in the horizontal and vertical directions, respectively, at a horizontal velocity of 250 µm s−1 and a frame rate of 2500 Hz, i.e. 0.4 ms exposure time per frame, yielding a data collection rate of 140 µm2 s−1. The detector reduces from 16 bits to 8 bits at frame rates above 2250 Hz, and the maximum count rate capability per pixel in 8 bit mode is reduced. The beam intensity was accordingly reduced by a factor of 10 for this scan by reducing the SSA dimensions to 0.004 mm × 0.02 mm.
To demonstrate fly-scanning free-run SXDM at high data rates correlated with XFM over a large area of a heterogeneous sample, a freestanding 30 µm thick section of shale containing a small calcite vein was scanned over an area of 800 µm × 440 µm. XFM maps were obtained at an incident energy of 10 keV, yielding 1.410 megapixel XFM images for 15 elements including K to Zn, Ce, Ba, Nd, Hf and Yb, simultaneously with a correlated 523 megapixel SXDM image when reconstructed at 24.5 nm pixel size. The −1 at a frame rate of 300 Hz, i.e. 3.33 ms exposure time per frame, yielding a data collection rate of 74 µm2 s−1. The whole scan consisting of 1.418 million frames took 79 min. There are more SXDM frames than XFM pixels because the detector continues freely acquiring frames during the ∼30 ms turnaround between scan lines, outside the XFM scan area.
was 500 nm in the horizontal and vertical directions and the scan velocity was 150 µm s5. Results and discussion
Interrogation of the positions where frames were acquired in each scan mode reveals the extent of missing data in ET compared with FR data collection. Figs. 2(a) and 2(b) compare the start-of-frame positions (stage events) for a 2 µm × 2 µm scan subregion of a 50 µm × 50 µm scan in ET and FR mode, respectively, and Figs. 2(c) and 2(d) show the full scan histograms of point spacings in these modes. The ET histogram is bimodal, with peaks centred at 100 nm and 200 nm having similar frequency. In contrast, the FR histogram has a single 100 nm peak [Fig. 2(d)], where the peak width is attributed to velocity variation of the scanning stage. Each instance of 200 nm spacing in the ET data represents a missed frame [Fig. 2(e)]. This is visually evident in Figs. 2(a) and 2(b) and is confirmed by comparing the sizes of the FR and ET datasets, where the latter includes only ∼66% of the number of frames compared with FR for a given scan area [Figs. 2(e) and 2(f)]. Missed frames result in an increased effective detector and fewer photons being collected per unit scan area. At higher velocities, or larger sampling intervals, the missing frames can result in insufficient probe overlap for reliable SXDM reconstructions. Furthermore, it is difficult to estimate the centre of the sample motion kernel, as the end-of-frame position is unknown [Fig. 2(g)]. Fig. 2(h) illustrates position interpolation in FR mode. Since the frame start and end are known, the centre of the sample motion kernel can be estimated. On the basis of obtaining more frames per unit area with more accurate positions for each frame, it is expected that the ptychographic image quality must be better for FR than ET.
SXDM reconstructions from each data collection mode are shown in Fig. 3. The ET scan shown in Fig. 3(a) has more artefacts than the FR scan shown in Fig. 3(b), most likely due to inaccurate estimation of the interpolated frame positions where there is missing data. For comparison, a scanning electron micrograph (SEM) of the sample is shown in Fig. 3(c), revealing that the lithography microfabrication is imperfect in the centre of the pattern, leaving an over-layer of Cr covering the central part and reducing contrast. Magnifying the image sub-region shown as a dashed rectangular ROI in Fig. 3(a) reveals that ET Fig. 3(d) resolves the finest details less clearly than FR Fig. 3(e).
To estimate the reconstruction quality, 37 line profiles were extracted along all spokes of the test pattern, from the central ring to the next across two edges. An example profile is shown as a dashed red line in Fig. 3(e). The extracted profiles are shown as light-grey lines in Fig. 4. The resolution was calculated as the average FWHM across the two edges obtained from the first derivative of the average profile (Dzhigaev et al., 2016), yielding 82 ± 4 nm for ET and 70 ± 1 nm for FR data collection with interpolated positions. The improved resolution obtained from FR data collection can be attributed both to measuring every frame, resulting in an increased number of photons collected per unit scan area, and to having more accurate positions for all frames, resulting in fewer reconstruction artefacts.
Fig. 5(a) shows the results of FR data at high scan speed and high frame rate, 250 µm s−1 and 2500 Hz, respectively, on a second test pattern of similar composition. The reconstructed SXDM image is faithful to the SEM image presented in Fig. 5(b). The reconstructed image quality was assessed in the same way as above. Line profiles were extracted across 35 spokes in the test pattern; two spokes with gaps were omitted. An example profile is shown as a solid line in Fig. 5(a). The extracted profiles are shown as light-grey lines in Fig. 5(c). The average FWHM of the first derivative (dashed line) of the average profile (solid line) in Fig. 5(c) yielded a resolution of 157 ± 2 nm. Comparing these results with Fig. 3, we note that the reduced combined with the increased scan line spacing to 500 nm, results in three orders of magnitude fewer photons per square micrometre of scan area. The achievable resolution could therefore be expected to degrade by a factor of up to 6.5, according to estimations of dose-resolution limits in diffraction microscopy (Howells et al., 2009). This reasoning would imply that the resolution in Fig. 3(b) could be improved by increasing M. However, reconstructing the data in Fig. 3(b) with M = 472, by extending the array to the edge of the detector, yields SXDM images (not shown) with 13.3 nm pixels and spatial resolution of 66 ± 2 nm. Based on the scattered intensity statistics in the data we conclude that the resolution-limiting factor is not the detection solid angle. Instead, we attribute this result to several other experimental factors, including the sample motion due to fly scanning, which may only be partially accounted for by the modal reconstruction, the beam stability during the scan and the positioning uncertainty resulting from encoder readout with a precision of 20 nm. We note that including the turnaround area in the ptychographic reconstruction introduced no detrimental effect on reconstructions.
Large-area XFM of thin geological sections provides a multitude of quantitative information, over orders of magnitude in length scales, which is important for answering questions at the forefront of geological sciences (Akker et al., 2021). Fig. 6(a) shows an 800 µm × 440 µm XFM map of a shale sample with a ∼175 µm wide vein filled with quartz and calcite grains as a tricolour overlay, with Cu in cyan, Fe in magenta and Mn in yellow. The pixel size in this image is 500 nm, although the spatial resolution is limited by the probe size at the sample of around 2.0 µm FWHM. Fig. 6(b) shows a 100 µm × 100 µm ROI of this XFM image, while Fig. 6(c) shows the SXDM reconstruction of the coherent diffraction data in the same ROI, wherein the reconstructed pixel size is 24.5 nm. SXDM phase images clearly show details not observed in the XFM images. The white stemless arrowheads in Fig. 6(a) mark the typical pyramidal endings of quartz crystals (which appear black) growing into the vein. In the enlarged XFM map [Fig. 6(b)], the region near the tip of such a quartz crystal does not show any internal elemental zoning (white stemless arrowhead) while the SXDM map [Fig. 6(c)] unveils significant internal structure (black stemless arrowhead), possibly reflecting different growth increments. The solid white arrow in Fig. 6(b) marks a linear region of chemically homogeneous chlorite overgrowth on a quartz grain boundary. The corresponding region in the SXDM map [Fig. 6(c), solid black arrow] resolves the subvertical interfaces of the chlorite–quartz interfaces and displays a rich internal structure where the quartz crystal locks onto the shale matrix. The dashed arrows in Figs. 6(b) and 6(c) show how clearly the tip of a dolomite crystal is resolved in SXDM compared with XFM. It is clear that the combination of SXDM phase and XFM elemental maps delivers insights not available from either method in isolation.
6. Conclusions
We have implemented and demonstrated high-speed reliable free-run SXDM on the Australian Synchrotron XFM beamline, including a data analysis pipeline that permits general user access to ptychographic imaging. By allowing the data to be collected by the detector without sending an individual trigger to the detector for each exposure, and interpolating stage events recorded on a far finer grid than the scan positions, robust high-quality SXDM reconstructions are obtained and non-measurement −1, and at a data collection rate of 140 µm2 s−1, which to our knowledge is the fastest X-ray ptychography reported to date. We have demonstrated that this provides ultrastructural phase-contrast context for XFM images at approximately 13 times finer resolution than the beam size over large areas. The resolution can be further increased by slower scanning. However, we found that the resolution limit is dictated by experimental factors including the fly-scan motion of the sample during each diffraction measurement, the beam stability during a scan and the positioning accuracy, rather than the diffracted intensity measured per frame.
is eliminated. This ensures that all possible photons incident on the sample are collected and the data reliably reconstruct to high fidelity, even for sample velocities up to 250 µm sWe anticipate that fast-scanning simultaneous XFM and SXDM over large areas will have an immediate and powerful impact in materials science, advanced manufacturing, and particularly in geoscience, where structure and chemistry are inherently linked over a large range of length scales. Moreover, the ptychographic reconstruction of a high-resolution complex probe beam could yield resolution enhancement of the XFM images through deconvolution (Vine et al., 2012). This method is relatively detector independent, applicable to most fast-readout low systems. As detector count-rate capabilities and coherent improve, we anticipate that scan speeds such as this will become routine, and ptychography data collection rates will become compatible with fast-scanning microprobes and nanoprobes such as the future Australian Synchrotron Nanoprobe beamline.
Upcoming milestones in the SXDM development roadmap on the XFM beamline are the installation of a DMM providing 20–30× et al., 2014; Yao et al., 2021), and the implementation of a high-precision rotation stage for ptychographic X-ray computed tomography (Dierolf et al., 2010).
increase, permitting broadband SXDM (EndersAcknowledgements
Synchrotron data were collected on the XFM beamline of the Australian Synchrotron, part of ANSTO. Andreas Moll and Ron Bosworth from ANSTO are acknowledged for providing a high-performance computing test platform and for stimulating discussions about the XFM beamline cluster implementation. Robin Kirkham and Chris Ryan from CSIRO are acknowledged for helpful discussions regarding the Maia data stream, and for including stage events that make fast and accurate ptychography frame registration possible. Brian Abbey from La Trobe University is acknowledged for helpful discussions and for providing funding for early development of the data analysis pipeline. David Paterson and Daryl Howard from ANSTO are acknowledged for assistance with XFM commissioning experiments. Stephen Mudie from ANSTO is acknowledged for assistance with integrating the EPICS area-detector software developed by Mark Rivers at Argonne National Laboratory. Bjoern Enders and the PtyPy development community are acknowledged for implementation assistance and continuous effort in software improvements.
Funding information
The purchase of the EIGER2 detector was supported in part by an ARC Linkage Infrastructure, Equipment and Facilities (LIEF) grant (No. LE130100192). Christoph E. Schrank gratefully acknowledges funding by the Australian Research Council through a Discovery grant (No. DP170104550). Nicholas W. Phillips acknowledges funding from the European Research Council (ERC) under the European Union Horizon 2020 research and innovation programme (grant agreement No. 714697) and under the Marie Skłodowska-Curie Actions (grant agreement No. 884104 PSI-FELLOW-III-3i).
References
Afshar, N., de Jonge, M. D., Paterson, D., Howard, D. L. & Starritt, A. (2017). 16th International Conference on Accelerator and Large Experimental Control Systems (ICALEPCS2017), 8–13 October 2017, Barcelona, Spain. WEBPL08. Google Scholar
Akker, I. V., Berger, A., Schrank, C. E., Jones, M. W. M., Kewish, C. M., Klaver, J. & Herwegh, M. (2021). J. Struct. Geol. 150, 140404. Web of Science CrossRef Google Scholar
Bø Fløystad, J., Skjønsfjell, E. T. B., Guizar-Sicairos, M., Høydalsvik, K., He, J., Andreasen, J. W., Zhang, Z. & Breiby, D. W. (2015). Adv. Eng. Mater. 17, 545–553. Google Scholar
Chen, B., Guizar-Sicairos, M., Xiong, G., Shemilt, L., Diaz, A., Nutter, J., Burdet, N., Huo, S., Mancuso, J., Monteith, A., Vergeer, F., Burgess, A. & Robinson, I. (2013). Sci. Rep. 3, 1177. Web of Science CrossRef PubMed Google Scholar
Ciani, A., Toumi, H., Pallu, S., Tsai, E. H. R., Diaz, A., Guizar-Sicairos, M., Holler, M., Lespessailles, E. & Kewish, C. M. (2018). Bone Rep. 9, 122–131. CrossRef PubMed Google Scholar
Clark, J. N., Huang, X., Harder, R. J. & Robinson, I. K. (2014). Opt. Lett. 39, 6066–6069. Web of Science CrossRef PubMed Google Scholar
Deng, J., Nashed, Y. S. G., Chen, S., Phillips, N. W., Peterka, T., Ross, R., Vogt, S., Jacobsen, C. J. & Vine, D. J. (2015). Opt. Express, 23, 5438–5451. Web of Science CrossRef CAS PubMed Google Scholar
Deng, J., Preissner, C., Klug, J. A., Mashrafi, S., Roehrig, C., Jiang, Y., Yao, Y., Wojcik, M., Wyman, M. D., Vine, D., Yue, K., Chen, S., Mooney, T., Wang, M., Feng, Z., Jin, D., Cai, Z., Lai, B. & Vogt, S. (2019). Rev. Sci. Instrum. 90, 083701. Web of Science CrossRef PubMed Google Scholar
Deng, J., Vine, D. J., Chen, S., Nashed, Y. S. G., Jin, Q., Phillips, N. W., Peterka, T., Ross, R., Vogt, S. & Jacobsen, C. J. (2015). Proc. Natl Acad. Sci. USA, 112, 2314–2319. Web of Science CrossRef CAS PubMed Google Scholar
Dierolf, M., Menzel, A., Thibault, T., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O. & Pfeiffer, F. (2010). Nature, 467, 436–439. Web of Science CrossRef CAS PubMed Google Scholar
Du, M., Di, Z., Gürsoy, D., Xian, R. P., Kozorovitskiy, Y. & Jacobsen, C. (2021). J. Appl. Cryst. 54, 386–401. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dzhigaev, D., Shabalin, A., Stankevič, T., Lorenz, U., Kurta, R. P., Seiboth, F., Wallentin, J., Singer, A., Lazarev, S., Yefanov, O. M., Borgström, M., Strikhanov, M. N., Samuelson, L., Falkenberg, G., Schroer, C. G., Mikkelsen, A., Feidenhans'l, R. & Vartanyants, I. A. (2016). J. Opt. 18, 064007. Web of Science CrossRef Google Scholar
Enders, B., Dierolf, M., Cloetens, P., Stockmar, M., Pfeiffer, F. & Thibault, P. (2014). Appl. Phys. Lett. 104, 171104. Web of Science CrossRef Google Scholar
Enders, B. & Thibault, P. (2016). Proc. R. Soc. London A, 472, 20160640. Web of Science CrossRef Google Scholar
Faulkner, H. M. L. & Rodenburg, J. M. (2004). Phys. Rev. Lett. 93, 023903. Web of Science CrossRef PubMed Google Scholar
Genoud, S., Jones, M. W. M., Trist, B. G., Deng, J., Chen, S., Hare, D. J. & Double, K. L. (2020). Chem. Sci. 11, 8919–8927. Web of Science CrossRef CAS PubMed Google Scholar
Guizar-Sicairos, M., Johnson, I., Diaz, A., Holler, M., Karvinen, P., Stadler, H.-C., Dinapoli, R., Bunk, O. & Menzel, A. (2014). Opt. Express, 22, 14859–14870. Web of Science PubMed Google Scholar
Hegerl, R. & Hoppe, W. (1970). Ber. Bunsenges. Phys. Chem. 74, 1148–1154. CrossRef CAS Web of Science Google Scholar
Howard, D. L., de Jonge, M. D., Afshar, N., Ryan, C. G., Kirkham, R., Reinhardt, J., Kewish, C. M., McKinlay, J., Walsh, A., Divitcos, J., Basten, N., Adamson, L., Fiala, T., Sammut, L. & Paterson, D. J. (2020). J. Synchrotron Rad. 27, 1447–1458. Web of Science CrossRef CAS IUCr Journals Google Scholar
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., Sayre, D., Shapiro, D. A., Spence, J. C. H. & Starodub, D. (2009). J. Electron Spectrosc. Relat. Phenom. 170, 4–12. Web of Science CrossRef CAS Google Scholar
Huang, X., Lauer, K., Clark, J. N., Xu, W., Nazaretski, E., Harder, R., Robinson, I. K. & Chu, Y. S. (2015). Sci. Rep. 5, 9074. Web of Science CrossRef PubMed Google Scholar
Jones, M. W. M., Phillips, N. W., Abbey, B., Hare, D. J., van Riessen, G. A., Vine, D. J., de Jonge, M. D. & McColl, G. (2019). Chem Commun. 55, 1052–1055. Web of Science CrossRef CAS Google Scholar
Jones, M. W. M., Phillips, N. W., van Riessen, G. A., Abbey, B., Vine, D. J., Nashed, Y. S. G., Mudie, S. T., Afshar, N., Kirkham, R., Chen, B., Balaur, E. & de Jonge, M. D. (2016). J. Synchrotron Rad. 23, 1151–1157. Web of Science CrossRef IUCr Journals Google Scholar
Kourousias, G., Bozzini, B., Jones, M. W. M., Van Riessen, G. A., Dal Zilio, S., Billè, F., Kiskinova, M. & Gianoncelli, A. (2018). Appl. Nanosci. 8, 627–636. Web of Science CrossRef CAS Google Scholar
Maiden, A. M. & Rodenburg, J. M. (2009). Ultramicroscopy, 109, 1256–1262. Web of Science CrossRef PubMed CAS Google Scholar
Menzel, A., Kewish, C. M., Kraft, P., Henrich, B., Jefimovs, K., Vila-Comamala, J., David, C., Dierolf, M., Thibault, P., Pfeiffer, F. & Bunk, O. (2010). Ultramicroscopy, 110, 1143–1147. Web of Science CrossRef CAS PubMed Google Scholar
Nashed, Y. S. G., Vine, D. J., Peterka, T., Deng, J., Ross, R. & Jacobsen, C. (2014). Opt. Express, 22, 32082–32097. Web of Science CrossRef PubMed Google Scholar
Pelz, P. M., Guizar-Sicairos, M., Thibault, P., Johnson, I., Holler, M. & Menzel, A. (2014). Appl. Phys. Lett. 105, 251101. Web of Science CrossRef Google Scholar
Ryan, C. G. & Jamieson, D. N. (1993). Nucl. Instrum. Methods Phys. Res. B, 77, 203–214. CrossRef Web of Science Google Scholar
Ryan, C. G., Kirkham, R., de Jonge, M. D., Siddons, D. P., van der Ent, A., Pagés, A., Boesenberg, U., Kuczewski, A. J., Dunn, P., Jensen, M., Liu, W., Harris, H., Moorhead, G. F., Paterson, D. J., Howard, D. L., Afshar, N., Garrevoet, J., Spiers, K., Falkenberg, G., Woll, A. R., De Geronimo, G., Carini, G. A., James, S. A., Jones, M. W. M., Fisher, L. A. & Pearce, M. (2018). Synchrotron Radiat. News, 31(6), 21–27. CrossRef Google Scholar
Ryan, C. G., Laird, J. S., Fisher, L. A., Kirkham, R. & Moorhead, G. F. (2015). Nucl. Instrum. Methods Phys. Res. B, 363, 42–47. Web of Science CrossRef CAS Google Scholar
Schrank, C. E., Jones, M. W. M., Kewish, C. M., van Riessen, G. A., Elphick, K. E., Sloss, C. R., Nothdurft, L., Webb, G. E., Paterson, D. J. & Regenauer-Lieb, K. (2021). Commun. Earth Environ. 2, 174. CrossRef Google Scholar
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C. & Pfeiffer, F. (2008). Science, 321, 379–382. Web of Science CrossRef PubMed CAS Google Scholar
Thibault, P. & Guizar-Sicairos, M. (2012). New J. Phys. 14, 063004. Web of Science CrossRef Google Scholar
Thibault, P., Guizar-Sicairos, M. & Menzel, A. (2014). J. Synchrotron Rad. 21, 1011–1018. Web of Science CrossRef IUCr Journals Google Scholar
Thibault, P. & Menzel, A. (2013). Nature, 494, 68–71. Web of Science CrossRef CAS PubMed Google Scholar
Trtik, P., Diaz, A., Guizar-Sicairos, M., Menzel, A. & Bunk, O. (2013). Cem. Concr. Compos. 36, 71–77. Web of Science CrossRef CAS Google Scholar
Vine, D. J., Pelliccia, D., Holzner, C., Baines, S. B., Berry, A., McNulty, I., Vogt, S., Peele, A. G. & Nugent, K. A. (2012). Opt. Express, 20, 18287–18296. Web of Science CrossRef CAS PubMed Google Scholar
Yao, Y., Jiang, Y., Klug, J., Nashed, Y., Roehrig, C., Preissner, C., Marin, F., Wojcik, M., Cossairt, O., Cai, Z., Vogt, S., Lai, B. & Deng, J. (2021). J. Synchrotron Rad. 28, 309–317. Web of Science CrossRef IUCr Journals Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.