Figure 6
Calculated dependence of the harmonic contribution on a shift of the aperture center from the FEL axis for three different fundamental photon energies (730 eV, 1000 eV and 1500 eV). The aperture has a size of 1 mm × 1 mm and is located 196 m downstream of the undulator. (a) Second-harmonic contribution, horizontal shift; (b) second-harmonic contribution, vertical shift; (c) third-harmonic contribution, horizontal or vertical shift. The shaded areas represent a 2σ range around the measured values.