view article

Figure 2
Sheep head HiP-CT scan at an average detected energy of 109 K eV, 5 K × 5 K pixels images. Left, the Paganin et al. algorithm at the average detected beam energy. Right, the result obtained using the algorithms introduced by the present work. For EPR we have considered five spectral points across the BM18 detected spectrum and we have applied SLD for a tail containing 30% of the total signal and a damping length of 80 pixels. We used the refractive indexes for 75% hydroxyapatite, 25% collagen. The regions marked A, B, C and D are shown in detail in Fig. 3[link], highlighting a detailed comparison between EPR and Paganin et al. methods.