view article

Figure 4
PDF analysis as a function of temperature during the heating ramp. (a) Full G(r) profile. The insets show magnified views of the first and third peaks. The lower panels show, as a function of temperature in two different scans; (b) the mean position of the first peak, r1; (c) the standard deviation of the first peak, σ1; and (d) the mean position of the third peak, r3. The red dashed line in (d) shows a linear fit of the data.