[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

[Contents scheme]

Acta Cryst. (2004). E60, m1757-m1758  [ doi:10.1107/S1600536804027497 ]

(N-Benzoyl-N-phenylhydroxaminato-[kappa]2O,O')(salicylaldehyde isonicotinoylhydrazonato-[kappa]3O,N,N')vanadium(IV) hexane hemisolvate

S. Gao, L.-H. Huo, H. Zhao and S. W. Ng

Online 6 November 2004


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.725 0.926 Tmin' and Tmax expected: 0.849 0.925 RR' = 0.853 Please check that your absorption correction is appropriate. PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ? PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.85 PLAT068_ALERT_1_C Reported F000 Differs from Calcd (or Missing)... ? PLAT152_ALERT_1_C Supplied and Calc Volume s.u. Inconsistent ..... ? PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) V1 - N1 .. 5.35 su PLAT420_ALERT_2_C D-H Without Acceptor N2 - H2N ... ? PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 11 O5 -V1 -O3 -C14 5.00 0.80 1.555 1.555 1.555 1.555
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 8 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 3 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 2 ALERT type 2 Indicator that the structure model may be wrong or deficient 2 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion

Copyright © International Union of Crystallography
IUCr Webmaster