short communications
Beam-induced oxidation of monomeric U(IV) species
aEnvironmental Microbiology Laboratory, Ecole Polytechnique, Fédérale de Lausanne, Switzerland, and bSwiss Light Source, Paul Scherrer Institut, Villigen-PSI, Switzerland
*Correspondence e-mail: daniel.alessi@epfl.ch
Uranium LIII-edge X-ray absorption spectroscopy is often used to probe the and coordination of uranium in environmental samples, and micrometre-sized beams can be used to spatially map the distribution of uranium relative to other elements. Here a variety of uranium-containing environmental samples are analyzed at both microbeam and larger beam sizes to determine whether reoxidation of U(IV) occurred. Monomeric U(IV), a recently discovered product of U(VI) reduction by microbes and certain iron-bearing minerals at uranium-contaminated field sites, was found to be reoxidized during microbeam (3 µm × 2 µm) analysis of biomass and sediments containing the species but not at larger beam sizes. Thus, care must be taken when using X-ray microprobes to analyze samples containing monomeric U(IV).
Keywords: uranium; monomeric U(IV); X-ray absorption spectroscopy; oxidation; beam damage; microbeam.
1. Introduction
Monomeric U(IV) is a recently discovered non-crystalline product of U(VI) reduction by microbes, iron-bearing biogenic minerals and in biostimulated natural sediments (e.g. Bernier-Latmani et al., 2010; Fletcher et al., 2010; Veeramani et al., 2011; Sharp et al., 2011; Cologgi et al., 2011). The species may form along with the crystalline U(IV) phase uraninite, UO2(s), in laboratory experiments and in field-scale remediation efforts that aim to reduce U(VI) to less soluble U(IV) species. Key to differentiating U(VI), uraninite and monomeric U(IV) in environmental samples is the application of U LIII-edge (Kelly, 2010). In particular, element-specific mapping using an X-ray microbeam can be employed to determine the association of heavy metals such as uranium with other elements in the sample, and provide insights into surface species and solid phases (e.g. Bertsch & Hunter, 2001; Kemner et al., 2004; Punshon et al., 2005). Because of the relatively high incident photon-flux density applied to the sample while using microbeam techniques (Lombi et al., 2011), there is an increased likelihood that uraninite or monomeric U(IV) could be reoxidized during sample analysis. In this study we prepared a set of U(IV)-containing samples and a U(VI) standard and analyzed them using both a microbeam and larger beam sizes at the Swiss Light Source (SLS). The goal of our analyses was to determine what conditions, if any, would lead to U(IV) oxidation in our experimental systems.
2. Experimental
All experimental systems were prepared in duplicate, and are detailed in Table 1. A hydrous ferric oxide (HFO) was produced by precipitation of a ferric chloride solution using concentrated NaOH (see Veeramani et al., 2011). The washed HFO was suspended to 50 mM as Fe(III) in a solution containing 400 µM U(VI), and all the U(VI) was quickly adsorbed to the HFO. Uranium dioxide [UIVO2], hereafter referred to as chemogenic uraninite, was analyzed as received (International Bio-Analytical Industries, Boca Raton, Florida, USA). Monomeric U(IV) and biogenic uraninite were produced via U(VI) reduction by Shewanella oneidensis MR-1 bacterial cells according to the methods given by Bernier-Latmani et al. (2010). These bacterial samples were pelleted by centrifugation (10000 g for 10 min) and mounted into Teflon sample holders with Kapton® tape windows (DuPont, Wilmington, Delaware, USA) in an anaerobic chamber containing 3% H2(g) and a balance N2(g). A biostimulated natural sediment from Rifle, Colorado, or RABS sediment (Anderson et al., 2003), containing monomeric U(IV) species (see Sharp et al., 2011) was fixed in epoxy, mounted on glass slides and polished to a thickness of 30 µm. All samples were transported to SLS in hermetically sealed stainless steel shipping canisters (Schuett-biotec GmbH, Göttingen, Germany) filled to a slightly positive pressure with N2(g).
|
Uranium LIII-edge was conducted at the microXAS beamline of the SLS. The beamline layout is described in greater detail by Borca et al. (2009). Using the beamline slits, samples were analyzed with a collimated `large' beam with sizes of 500 µm × 500 µm, and 100 µm × 100 µm. The X-ray microbeam was produced by condensing an initial acceptance of 300 µm × 300 µm into a spot of 3 µm × 2 µm by employing reflective mirrors. Measurements were performed in fluorescence mode and using a Si drift diode detector. A double-crystal Si(111) monochromator (DCM) was used to select energies. During analysis, samples were placed under a constant stream of N2(g). Energies were rastered between 17.06 and 17.60 keV for 12.8 min for each scan, and 8–16 scans were collected per sample. Reduction of the XANES raw data was carried out using the ATHENA program (Ravel & Newville, 2005) by subtracting a background signal (fitted through an appropriate pre-edge range) and normalizing to the main edge jump. The was defined as the energy corresponding to the first inflection point (maximum of first derivative).
An ion chamber of reduced dimensions, developed in-house, was used to monitor the incoming beam intensity (I0) during the spectroscopic measurements, adapting the type of flowing gas with the energy needed. The of the variable beam sizes was determined using a Hamamatsu Si PIN photodiode (model S3590-02), analogous to that of Owen et al. (2009). The obtained photon fluxes were in close agreement with theoretical calculations based on known beamline source and optics characteristics. For the large beam sizes, the obtained is 2.5 × 1011 monochromatic [Si(111) DCM] photons per second, while, in the microbeam, 0.4 × 1011 photons per second were delivered. Assuming a photon energy of 17.2 keV, approximately 25% of incident photons were absorbed in the 200 µm-thick Si diode (Owen et al., 2009).
3. Results and discussion
The objective of the study was to determine X-ray beam conditions under which U(IV) species, including monomeric U(IV) and uraninite, may oxidize to U(VI). Of particular interest was the potential oxidation induced by X-ray microbeams because of the increased use of microbeams for elemental mapping and spatially resolved ). The oxidation of uranium was observed in the biomass monomeric U(IV) sample and the thin-sectioned RABS sediment. Consequently, the following discussion will focus on these experimental systems.
analyses of uranium-contaminated soils and sediments. No changes in uranium valence state were observed under any beam size (500 µm × 500 µm, 100 µm × 100 µm and 3 µm × 2 µm) for the chemogenic uraninite, biogenic uraninite or HFO with adsorbed U(VI) experimental systems (Table 1XANES data from the microbeam analyses of the biomass-associated monomeric U(IV) samples are presented in Fig. 1(a). A marked difference between the first scan (dotted line) and the average of seven subsequent scans (solid line) is observed. In particular, there is a shift in the position and intensity of the white line, and a flattening and rise in the region centred around 17.19 keV, marked with arrows. The feature at 17.19 keV is typically associated with U(VI), probably the more tightly bound axial O atoms of the uranyl [UVIO22+] cation (Kelly, 2010) as is observed for the U(VI) standard. Therefore, the shift observed between the first and subsequent scans is indicative of uranium oxidation. The averaged spectra for the HFO + U(VI) system (dashed line) show the presence of these features in a sample that contains 100% U(VI). Fig. 1(b) displays XANES spectra collected under large beam (500 µm × 500 µm) conditions. Essentially no change is observed between the initial scan (dotted line) and the average of subsequent scans (solid line) of the biomass monomeric U(IV) sample. Hence, the observed beam damage is attributable to the microbeam conditions (3 µm × 2 µm) rather than the sample run conditions.
Fig. 2 displays the XANES results from the biostimulated RABS sediment containing monomeric U(IV). Similar to the biomass monomeric U(IV) system, there is a large change between the first spectrum (dotted line) and the average of seven subsequent scans (solid line) during microbeam analyses (Fig. 2a). The same shift in the white line and resonance feature at 17.19 keV is also observed, indicative of monomeric U(IV) oxidation in the slide-mounted sediment sample. No change is observed between the first scan (dotted line) and subsequent scans (solid line) when the same sample is analyzed using the 500 µm × 500 µm beam size (Fig. 2b).
The 2) is more than 6000 times greater under microbeam conditions than the large beam (500 µm × 500 µm) in the two monomeric U(IV) systems. Because of the much smaller spot size used in microprobe analyses, a higher incident is necessary for the collection of data of sufficient quality. The relatively intense beam can lead to dehydration (heating) of hydrated organic samples (e.g. Lombi et al., 2011), and in our study likely lead to the oxidation of redox-sensitive monomeric U(IV) species to U(VI) after approximately 13 min of beam exposure.
(photons per µm4. Conclusions
analyses of U(VI), uraninite and monomeric U(IV) containing systems indicate that monomeric U(IV) may be oxidized in biomass and sediment samples under X-ray microbeam conditions. Specifically, we show that the microbeam alters the XANES spectra of biomass-associated monomeric U(IV) and monomeric U(IV) contained in natural sediments, consistent with oxidation to U(VI). Those employing X-ray microbeams to perform element-mapping or micrometre-scale analyses of samples that may contain monomeric U(IV) should consider that the species may be oxidized owing to the intensity of incoming photons.
Acknowledgements
The authors thank Kelly Plathe for her assistance in
analyses of the samples. DSA was partially supported by a Marie Curie International Incoming Fellowship from the European Commission, grant FP7-PEOPLE-2009-IIF-254143. This work was performed at the microXAS beamline (proposal 20091011) of the Swiss Light Source, Paul Scherrer Institut, Villigen, Switzerland.References
Anderson, R. T., Vrionis, H. A., Ortiz-Bernad, I., Resch, C. T., Long, P. E., Dayvault, R., Karp, K., Marutzky, S., Metzler, D. R., Peacock, A., White, D. C., Lowe, M. & Lovley, D. R. (2003). Appl. Environ. Microbiol. 69, 5884–5891. Web of Science CrossRef PubMed CAS Google Scholar
Bernier-Latmani, R., Veeramani, H., Vecchia, E. D., Junier, P., Lezama-Pacheco, J. S., Suvorova, E. I., Sharp, J. O., Wigginton, N. S. & Bargar, J. R. (2010). Environ. Sci. Technol. 44, 9456–9462. Web of Science CAS PubMed Google Scholar
Bertsch, P. M. & Hunter, D. B. (2001). Chem. Rev. 101, 1809–1842. Web of Science CrossRef PubMed CAS Google Scholar
Borca, C. N., Grolimund, D., Willimann, M., Meyer, B., Jefimovs, K., Vila-Comamala, J. & David, C. (2009). J. Phys. Conf. Ser. 186, 012003. CrossRef Google Scholar
Cologgi, D. L., Lampa-Pastirk, S., Speers, A. M., Kelly, S. D. & Reguera, G. (2011). Proc. Natl. Acad. Sci. USA, 37, 15248–15252. Web of Science CrossRef Google Scholar
Fletcher, K. E., Boyanov, M. I., Thomas, S. H., Wu, Q., Kemner, K. M. & Löffler, F. E. (2010). Environ. Sci. Technol. 44, 4705–4709. Web of Science CrossRef CAS PubMed Google Scholar
Kelly, S. D. (2010). Synchrotron-Based Techniques in Soils and Sediments, Vol. 34, edited by B. Singh and M. Gräfe, 1st ed, pp. 411–466. Oxford: Elsevier. Google Scholar
Kemner, K. M., Kelly, S. D., Lai, B., Maser, J., O'Loughlin, E. J., Sholto-Douglas, D., Cai, Z., Schneegurt, M. A., Kulpa, C. F. & Nealson, K. H. (2004). Science, 306, 686–687. Web of Science CrossRef PubMed CAS Google Scholar
Lombi, E., de Jonge, M. D., Donner, E., Ryan, C. G. & Paterson, D. (2011). Anal. Bioanal. Chem. 400, 1637–1644. Web of Science CrossRef CAS PubMed Google Scholar
Owen, R. L., Holton, J. M., Schulze-Briese, C. & Garman, E. F. (2009). J. Synchrotron Rad. 16, 143–151. Web of Science CrossRef CAS IUCr Journals Google Scholar
Punshon, T., Jackson, B. P., Lanzirotti, A., Hopkins, W. A., Bertsch, P. M. & Burger, J. (2005). Spectrosc. Lett. 38, 343–363. Web of Science CrossRef CAS Google Scholar
Ravel, B. & Newville, M. (2005). J. Synchrotron Rad. 12, 537–541. Web of Science CrossRef CAS IUCr Journals Google Scholar
Sharp, J. O., Lezama-Pacheco, J. S., Schofield, E. J., Junier, P., Ulrich, K.-U., Chinni, S., Veeramani, H., Margot-Roquier, C., Webb, S. M., Tebo, B. M., Giammar, D., Bargar, J. R. & Bernier-Latmani, R. (2011). Geochim. Cosmochim. Acta, 75, 6497–6510. Web of Science CrossRef CAS Google Scholar
Veeramani, H., Alessi, D. S., Suvorova, E. I., Lezama-Pacheco, J. S., Stubbs, J. E., Sharp, J. O., Dippon, U., Kappler, A., Bargar, J. R. & Bernier-Latmani, R. (2011). Geochim. Cosmochim. Acta, 75, 2512–2528. Web of Science CrossRef CAS Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.