X-ray Fourier transform holography by amplitude-division-type Fresnel zone plate interferometer
aFaculty of Physics, Yerevan State University, Alex Manoogian 1, Yerevan 0025, Armenia
*Correspondence e-mail: mbalyan@ysu.am
A two-block X-ray Fresnel zone plate system forms two-beams – a plane wave and a spherical wave – which interfere at the focal distance of the virtual source of the spherical wave. An object placed in the path of the plane wave forms an object wave and the spherical wave is the reference wave. The recorded intensity distribution is the Fourier transform hologram of the object. Analytical and numerical calculations show the possibilities of this scheme to record the hologram and reconstruct the object image. Examples of recording holograms of a one-dimensional cosine-like grating and a two-dimensional grid object as well as reconstruction of the images are considered.
1. Introduction
X-ray holography is one of the methods of investigating objects. In the hard X-ray region, various holographic schemes have been presented, such as X-ray in-line holography (Snigirev et al., 1995; Nugent et al., 1996; Paganin, 2006, and references therein), X-ray Gabor holography and Fourier transform holography (FTH) (McNulty et al., 1992; Leitenberger & Snigirev, 2001; Watanabe et al., 2003; Iwamoto & Yagi, 2011). Watanabe et al. (2004) suggested an X-ray two-zone-plates FTH scheme. X-ray holography schemes have also been presented: for example, X-ray interferometric holography (including the Momose method) (Egiazaryan & Bezirganyan, 1980; Momose, 1995; Egiazaryan, 1998; Egiazaryan et al., 1998; Balyan, 2016a,b), X-ray Fraunhofer holography (Balyan, 2013) and X-ray Fourier transform holography (Balyan, 2015). Using hard X-ray holographic methods, the reconstruction can be performed by visible light or numerical (mathematical) methods.
Different schemes of X-ray phase contrast imaging with optical magnification based on two-block Fresnel zone plate (FZP) interferometers have been suggested (Wilhein et al., 2001; Koyama et al., 2004, 2006; Watanabe et al., 2009). These interferometers operate in phase-front division mode. As a result, strong coherence requirements must be fulfilled. A three-plate FZP interferometer (Haroutunyan, 2015, 2016), operating in amplitude-division mode, has been suggested as well. In Fig. 1 a scheme of the interferometer is shown. The first block of the interferometer operates as a splitter, the second and third as mirror and analyzer, respectively. `Unwanted' propagation channels arise due to the existence of multiple diffraction orders of the FZP. Suppression of the influences of those channels on the registered interference pattern is achieved by two knives located on the first and third FZPs and sufficient analyzer–image distance f. The test phase object (object from light elements) is located across the object wave, before it is focused in the second inter-block space, and the λ/2 phase shifter is located across the reference wave, after the second FZP (see Fig. 1). The phase contrast image is formed according to the thin lens formula.
In the present paper, based on the mentioned FZP interferometer, an X-ray FTH method is proposed and investigated both theoretically and by numerical simulation. The capabilities of the scheme for hologram recording and object image reconstruction are considered as well. In the case of a single zone plate it is known that the primary beam must be stopped (McNulty et al., 1992; Leitenberger & Snigirev, 2001), which means a loss of information from the central parts of the hologram. McNulty et al. (1992) mentioned `The lower spatial frequencies, corresponding to the larger scale features of the test patterns, are somewhat degraded because the beam stop blocked the central region of the hologram where the low frequencies are encoded.' This difficulty, as also noted by Watanabe et al. (2004), is avoided using a two-zone-plate system. In contrast to the scheme suggested by Watanabe et al. (2004), the scheme considered here operates in amplitude-division mode for low-spatial-frequency structures. The corresponding hologram is recorded by low coherency requirements similar to the triple-Laue X-ray interferometer (Bonse & Hart, 1965).
As we know, for X-ray FTH schemes (see, for example, McNulty et al., 1992; Leitenberger & Snigirev, 2001) where zone plates are used the detailed theory is not given. In our work the theory is given in detailed form. In particular, the necessary object–reference source distance, when the halo does not overlap with the real and conjugate images, is estimated [these estimates show that for the parameters of the scheme used by McNulty et al. (1992) the halo will overlap with the real and conjugate images]. In addition, in our work an expression for the reconstructed amplitude has been obtained, where the background corrections are taken into account, and the quadratic phase of the specimen is also taken into account, which cannot be ignored by an object of size ∼100 µm. The resolution is estimated based not only on the reference source size (McNulty et al., 1992; Leitenberger & Snigirev, 2001) but also based on the finite size of the hologram. The maximum of these two resolutions is the real resolution in an experiment.
The coherence requirements have been estimated as well. Based on estimates of the coherency requirements it should be mentioned that X-ray synchrotron sources or X-ray free-electron lasers are needed for high-resolution imaging.
2. X-ray FZP interferometric FTH
Instead of the scheme given in Fig. 1 we consider the scheme shown in Fig. 2. The third plate of the interferometer is replaced by a photo plate or digital detector, which detects the interference intensity of the reference and object waves. The object is now placed at the same distance from the second plate as the focus point after the second plate. The wave falling onto the object may be considered as a plane wave and the wave emerging from the focus spot after the second plate may be considered as a spherical wave. Thus the detector detects the interference between the spherical wave and the wave that has passed through the object. This scheme is one of the analogues of the FTH scheme, known in optics (Hariharan, 2002). Note that in the scheme of Fig. 2 the reference wave is the object wave of Fig. 1, and vice versa.
Consider the conditions under which the wave propagation channels, other than the object and reference waves, do not disturb the intensity distribution of the hologram. Denote by (m, n) the channel with X-ray diffraction in m and n orders on the first and second blocks of the interferometer accordingly. Neglecting third-order and higher diffractions, nine such propagation channels will remain. Two of them, (0,+1) and (+1,+1), represent the reference and object waves, respectively. Consider the influence of the remaining seven channels on the registered hologram. It is easy to show in the framework of geometrical optics that six of the remaining seven `undesirable' channels do not cross either the test object or the hologram, if the condition d ≥ R/3 is satisfied, where d is the distance of the knife edge from the optical axes and R is the radius of the FZP (see Fig. 2). The (+1,0) channel can only intersect with the upper part of the test object and the rays refracted from it at large angles can fall on the hologram. If the stronger condition d ≥ R/2 is satisfied, the channel passes above the test object and the hologram is not distorted.
The amplitude of the wave in the detection plane is
and the corresponding intensity is
Here, is the reference wave and is the object wave. The detected intensity (2) is the hologram of the object under investigation.
3. Intensity distribution of the hologram and image reconstruction
Let us consider the expressions (1) and (2) analytically. A detailed scheme and coordinate systems are shown in Fig. 3. The incident wave on the object entrance surface may be considered as a plane wave with unit amplitude. Thus, the object wave in the detection plane may be written in the form
where t is the amplitude of the object, 2a is the size of the object, and the integration is performed over the exit surface of the object; k is the wavenumber. In (3) the Huygens–Fresnel principle is applied (Paganin, 2006). For the reference wave in parabolic approximation one may write
where r is the intensity reflection coefficient and is the intensity of the FZP, is the distance between the focus point after the second plate and the #!X = #!y = 0 point of the detection plane. Since #!F = , and #!(R+d)/2F ∼ #!R/2F ∼ 10−4 is sufficiently small, then the approximations 1, #!F are valid. After these approximations, instead of equation (4) we have
Let us consider the third term on the right-hand side of (2),
where the following dimensionless coordinates are entered,
If #!ka2/F << 1, the first term in the exponential under the integral sign of (6) may be neglected and (6) represents the Fourier transform of the amplitude of the object. In the general case these terms must be taken into account. One may reconstruct the amplitude taking the inverse Fourier transform of (6),
Here, u and v are dimensionless parameters. The connection between them and the X and y coordinates will be established below. Integrations over #!p,q in the limits give
In the same way, for the reconstruction of the second term in equation (2) we have
As follows from the expression of t in equation (8), #!X = , #!y = #!av. Since t is localized in the limits , , then in equation (8) the image is localized in the limits
and the conjugate image in the limits
The regions (10) and (11) are separated along the OX axes since F sinθ > a, which is seen from Fig. 3, where O is the origin of the coordinate system shown in Fig. 3.
For the reconstructed field of the first term in equation (2) we have
Here the finite limits of integration are taken into account. As can be seen from (12), along OX is localized in the region ∼ ∼ ∼ 10−3. This estimation shows that this region and images are strongly separated.
For one finds
if
and = 0 otherwise. Thus, forms a halo around the centre of the reconstructed field. As can be seen from (10), (11) and (14), the halo does not intersect with the images when , which is equivalent to the condition
since #!a = and ≃ = #!a + #!d. It should be mentioned that the condition (15) must be strongly satisfied when the amplitude is determined, but it may not be strongly satisfied if an object image is reconstructed.
4. Determination of the amplitude transmission coefficient
The reconstructed field may be written as
If the condition (15) is fulfilled, in the region of the image . Using the hologram, one may calculate and, in the region of the image,
For each value of #!(u,v) taken in the region (10) the corresponding coordinates of the object can be found as #!X = , #!y = #!av, and for these values using the known #!Erec(u,v) the amplitude #!t (X,y) may be found according to (17).
5. Resolution
The resolution of the scheme is determined by three factors: the size of the reference source, the finite sizes of the hologram and the resolution of the detector (McNulty et al., 1992; Leitenberger & Snigirev, 2001). As has been mentioned by Leitenberger & Snigirev (2001), `a hologram recording using a lower resolution detector does not change the achievable image resolution'. The fact that the resolution in FTH is independent of the resolution of the detector has been mentioned by Watanabe et al. (2004) as well. This fact is also known in optics (Stroke et al., 1965). So the maximum of the reference source size and the resolution determined by the finite sizes of the hologram is the resolution of the scheme. The size of the reference source is the size of the focus spot of the FZP, which is equal to the size of the outermost Fresnel zone. This type of resolution has been considered in detail (McNulty et al., 1992; Leitenberger & Snigirev, 2001).
Consider the resolution, determined by the finite sizes of the hologram. The object may have a continuous distribution of matter or may consist of localized points. Let us first determine the resolution of the scheme for the case of a continuous amplitude –(9). The integrations over #!p,q, if one takes the limits , give the δ-functions
Let us turn to the formulae of the reconstruction (6)For finite size holograms in the formulas of reconstruction (6)–(9) we must take into account the finite integration limits when integrating over #!(p,q). As a result, instead of δ-functions one finds
In dimensional coordinates this gives the effective integration region about . In dimensional coordinates the function #!t (X,y) around the central point #!(X0,y0) = of equation (19) may be approximated as #!t (X,y) = #!t (X0,y0) + + . For resolving the object the variation = + of the amplitude when = = must be less than the average value of the modulus of t, i.e. , . This means that continuous amplitude transmission coefficients may be reconstructed which are almost constant in the regions with size in both directions X and y.
If the object contains localized inhomogeneities, two inhomogeneities (points) that are separated by the distances in both X and y directions may be resolved.
So, the resolution determined by the finite sizes of the hologram for both directions in dimensional coordinates is about
where = #!R/2N is the size of the outermost zone. In (20), for definiteness, d = R/2 (a = R/4) is taken.
6. Coherency requirements
The spatial and temporal coherency requirements of the incident radiation are determined by the scattering angle of the object wave on the object. The trajectories of the object and reference wave for both small and large scattering angles are shown in Fig. 4. As can be seen from Fig. 4, for small scattering angles the interferometer operates in amplitude-division mode with an equal path of trajectories in both channels of propagation. As a result the scheme works under low spatial and temporal coherency requirements of incident radiation. For large scattering angles the interferometer does not work in amplitude-division mode. The trajectories of the rays, coming to the same point of the hologram, are separated on the entrance surface of the interferometer. The maximal separation in the transverse direction is Δxm = Δym = 2a, and maximal path difference is Δlm ≃ 2R(R − d)/F. The longitudinal (temporal) coherence length lL is connected to the quasimonochromaticity of the beam, lL = λ2/Δλ. Here, Δλ is the range of wavelengths in the incident beam. The quasimonochromaticity does not disturb the intensity distribution of the hologram when the requirement lL ≥ Δlm is satisfied. According to the Van Cittert–Zernike theorem (Born & Wolf, 2002) the spatial (transverse) coherence length lT = Lλ/us, where us is the size of the source and L is the source-to-system distance. lT is connected to the size of the source. The size of the source does not disturb the intensity distribution of the hologram, when the condition lT ≥ 2a is fulfilled. In particular, taking d = R/2 [see equation (15)], one obtains the following conditions of coherency: lL ≥ R2/F = λN and lT ≥ R/2, where N is the number of zones.
Large-scale features of the object under investigation correspond to low spatial Fourier harmonics and low scattering angles of the object wave. In this case the hologram may be recorded under low coherency requirements. Small-scale features of the object correspond to high spatial Fourier harmonics and large scattering angles of the object wave. Accordingly the coherency requirements increase up to lL for temporal and lT for spatial coherences.
7. Examples
Consider two examples of hologram recording and reconstruction.
Example (1). Consider the amplitude #!t (X) of a one-dimensional cosine grating, which is given by the expression
where = 4 µm is taken. The case where the radiation wavelength = 0.1 nm, FZP focal length F = 1 m, FZP radius R = 195 µm, outermost Fresnel zone size = 0.25 µm, a = 0.25R (d = R/2), = 1.46 × 10−4 and Fsinθ = 0.75R is considered. The resolution due to the finite size of the reference source is 0.25 µm and according to (20) the resolution determined by the finite size of the hologram is 1 µm. The resulting resolution will be 1 µm. The image and conjugate image are located in the limits and , respectively; the halo and primary reconstructed field are located in the limits . In Fig. 5 the corresponding hologram intensity distribution is presented. The calculations are made using equation (2) taking into account the finite limits of the hologram. In Fig. 6 the real and imaginary parts of the reconstructed amplitude are shown. The reconstructed image is disturbed by the background, formed due to the reconstructed reference wave amplitude. This background is sufficiently high, since the amplitude of the reference wave is more than two times larger compared with the amplitude of the object wave. This background may be taken into account using the formulae (12) and (17). Formula (17) may be rewritten as
The reconstructed amplitude . It can be seen that in the middle part of the reconstructed image the reconstructed values are close to the values of the object amplitude At the edges the resolution is low. is calculated using (16), in which for the first three terms the finite size of the hologram is taken into account, and for the fourth term the formula (13) is used for simplicity.
taking into account the background correction, is shown in Fig. 7Example (2). The numerical simulation of the hologram of the two-dimensional amplitude object (see Fig. 8), as well as further image reconstruction, was performed (Fig. 9). The following values of the main experimental parameters were used in the numerical calculations: λ = 0.1 nm, F = 1 m, R = 275.7 µm, FZP outermost zone width = 181.5 nm, d = 43.1 µm, half-width of rectangle test object a = 78.6 µm. As can be seen from a comparison of Figs. 8(a) and 9, the reconstructed image matches well with the tested object. The authors consider that the noise at the bottom of the reconstructed image, as well as the radial pattern in its lower half, are caused by the failure of above-mentioned condition , required for blocking of `unwanted' channels of the wave propagation. As a result, part of the propagation channel (+1,0), passing through the test object, falls on the hologram. The additional numerical simulations, performed for different values of d, show the vanishing of the mentioned imperfections of reconstruction at #!d = and higher. The value of d in the case of Fig. 9 was chosen as #!d = 0.156R, with the aim to increase the size of the tested object as much as possible.
8. Summary
In this paper an X-ray FTH scheme based on a two-block FZP interferometric system operating in amplitude-division mode is suggested and theoretically and numerically considered. In the case of recording the low-spatial-frequency structures of the object the interferometer operates in amplitude-division mode and does not impose high requirements on the coherency of the initial radiation. The capability of the scheme to reconstruct the amplitude
of the amplitude and phase objects is shown. The resolution and coherence requirements of the scheme are estimated. Examples of reconstruction of the amplitude of a cosine grating and a two-dimensional object image are considered. This scheme may be part of an X-ray microscope, and may be realised using both synchrotron sources of X-ray radiation and X-ray free-electron lasers.References
Balyan, M. (2013). J. Synchrotron Rad. 20, 749–755. Web of Science CrossRef CAS IUCr Journals Google Scholar
Balyan, M. (2015). J. Contemp. Phys. 50, 394–403. CrossRef CAS Google Scholar
Balyan, M. (2016a). J. Contemp. Phys. 51, 79–88. CrossRef CAS Google Scholar
Balyan, M. (2016b). J. Contemp. Phys. 51, 289–298. CrossRef CAS Google Scholar
Bonse, U. & Hart, M. (1965). Appl. Phys. Lett. 6, 155–156. CrossRef Web of Science Google Scholar
Born, M. & Wolf, E. (2002). Principles of Optics, 7th ed. Cambridge University Press. Google Scholar
Egiazaryan, A. M. (1998). Pisma Zh. Tech. Fiz. 24, 55–59. Google Scholar
Egiazaryan, A. M. & Bezirganyan, P. A. (1980). Proc. Nat. Acad. Sci. Armen. Phys. 15, 35–43. CAS Google Scholar
Egiazaryan, A. M., Trouni, K. G. & Mkrtchyan, A. R. (1998). Pisma Zh. Exp. Teor. Fiz. 68, 681–684. CAS Google Scholar
Hariharan, P. (2002). Basics of Holography. Cambridge University Press. Google Scholar
Haroutunyan, L. A. (2015). J. Contemp. Phys. 50, 292–295. CrossRef CAS Google Scholar
Haroutunyan, L. A. (2016). J. Contemp. Phys. 51, 284–288. CrossRef CAS Google Scholar
Iwamoto, H. & Yagi, N. (2011). J. Synchrotron Rad. 18, 564–568. Web of Science CrossRef IUCr Journals Google Scholar
Koyama, T., Kagoshima, Y., Wada, I., Saikubo, A., Shimose, K., Hayashi, K., Tsusaka, Y. & Matsui, J. (2004). Jpn. J. Appl. Phys. 43, L421–L423. Web of Science CrossRef CAS Google Scholar
Koyama, T., Tsuji, T., Yoshida, K., Takano, H., Tsusaka, Y. & Kagoshima, Y. (2006). Jpn. J. Appl. Phys. 45, L1159–L1161. Web of Science CrossRef CAS Google Scholar
Leitenberger, W. & Snigirev, A. J. (2001). J. Appl. Phys. 90, 538–544. CrossRef CAS Google Scholar
McNulty, I., Kirz, J., Jacobsen, C., Anderson, E. H., Howells, M. R. & Kern, D. P. (1992). Science, 256, 1009–1012. CrossRef PubMed CAS Web of Science Google Scholar
Momose, A. (1995). Nucl. Instrum. Methods Phys. Res. A, 352, 622–628. CrossRef CAS Web of Science Google Scholar
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D. & Barnea, Z. (1996). Phys. Rev. Lett. 77, 2961–2964. CrossRef PubMed CAS Web of Science Google Scholar
Paganin, D. M. (2006). Coherent X-ray Optics. Oxford University Press. Google Scholar
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S. & Schelokov, I. (1995). Rev. Sci. Instrum. 66, 5486–5492. CrossRef CAS Web of Science Google Scholar
Stroke, G. W., Brumm, D. & Funkhouser, A. (1965). J. Opt. Soc. Am. 55, 1327–1328. CrossRef Google Scholar
Watanabe, N., Hoshino, M., Yamamoto, K., Aoki, S., Takeuchi, A. & Suzuki, Y. (2009). J. Phys. Conf. Ser. 186, 012021. CrossRef Google Scholar
Watanabe, N., Yokosuka, H., Ohogashi, T., Takano, H., Takeuchi, A., Suzuki, Y. & Aoki, S. J. (2003). J. Phys. IV Fr. 104, 551–556. CrossRef Google Scholar
Watanabe, N., Yokosuka, H., Ohogashi, T., Takano, H., Takeuchi, A., Suzuki, Y. & Aoki, S. J. (2004). AIP Conf. Proc. 705, 1340–1343. CrossRef CAS Google Scholar
Wilhein, T., Kaulich, B. & Susini, J. (2001). Opt. Commun. 193, 19–26. CrossRef CAS Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.