research papers\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Characterizing transmissive diamond gratings as beam splitters for the hard X-ray single-shot spectrometer of the European XFEL1

CROSSMARK_Color_square_no_text.svg

aEuropean XFEL GmbH, Holzkoppel 4, 22869 Schenefeld, Germany, bP10 Beamline, PETRA III, Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, 22607 Hamburg, Germany, and cPaul Scherrer Institut (PSI), 5232 Villigen, Switzerland
*Correspondence e-mail: naresh.kujala@xfel.eu

Edited by D. Cocco, SLAC National Accelerator Laboratory, USA (Received 21 December 2018; accepted 9 March 2019; online 26 April 2019)

The European X-ray Free Electron Laser (EuXFEL) offers intense, coherent femtosecond pulses, resulting in characteristic peak brilliance values a billion times higher than that of conventional synchrotron facilities. Such pulses result in extreme peak radiation levels of the order of terawatts cm−2 for any optical component in the beam and can exceed the ablation threshold of many materials. Diamond is considered the optimal material for such applications due to its high thermal conductivity (2052 W mK−1 at 300 K) and low absorption for hard X-rays. Grating structures were fabricated on free-standing CVD diamond of 10 µm thickness with 500 µm silicon substrate support. The grating structures were produced by electron-beam lithography at the Laboratory for Micro- and Nanotechnology, Paul Scherrer Institut, Switzerland. The grating lines were etched to a depth of 1.2 µm, resulting in an aspect ratio of 16. The characterization measurements with X-rays were performed on transmissive diamond gratings of 150 nm pitch at the P10 beamline of PETRA III, DESY. In this paper, the gratings are briefly described, and a measured diffraction efficiency of 0.75% at 6 keV in the first-order diffraction is shown; the variation of the diffraction efficiency across the grating surface is presented.

1. Introduction

Over the past decade, several X-ray free-electron laser (XFEL) facilities have been developed and constructed around the world. Two technologies have been pursued to construct electron accelerators for XFEL applications: warm, normal-conducting machines and cold, super-conducting accelerators (Emma et al., 2010[Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F., Ding, Y., Dowell, D., Edstrom, S., Fisher, A., Frisch, J., Gilevich, S., Hastings, J., Hays, G., Hering, P., Huang, Z., Iverson, R., Loos, H. M., Messerschmidt, M., Miahnahri, A., Moeller, S., Nuhn, H., Pile, G., Ratner, D., Rzepiela, J., Schultz, D., Smith, T., Stefan, P., Tompkins, H., Turner, J., Welch, J., White, W., Wu, J., Yocky, G. & Galayda, J. (2010). Nat. Photon. 4, 641-647.]; Allaria et al., 2012[Allaria, E., Appio, R., Badano, L., Barletta, W., Bassanese, S., Biedron, S. G., Borga, A., Busetto, E., Castronovo, D., Cinquegrana, P., Cleva, S., Cocco, D., Cornacchia, M., Craievich, P., Cudin, I., D'Auria, G., Dal Forno, M., Danailov, M. B., De Monte, R., De Ninno, G., Delgiusto, P., Demidovich, A., Di Mitri, S., Diviacco, B., Fabris, A., Fabris, R., Fawley, W., Ferianis, M., Ferrari, E., Ferry, S., Froehlich, L., Furlan, P., Gaio, G., Gelmetti, F., Giannessi, L., Giannini, M., Gobessi, R., Ivanov, R., Karantzoulis, E., Lonza, M., Lutman, A., Mahieu, B., Milloch, M., Milton, S. V., Musardo, M., Nikolov, I., Noe, S., Parmigiani, F., Penco, G., Petronio, M., Pivetta, L., Predonzani, M., Rossi, F., Rumiz, L., Salom, A., Scafuri, C., Serpico, C., Sigalotti, P., Spampinati, S., Spezzani, C., Svandrlik, M., Svetina, C., Tazzari, S., Trovo, M., Umer, R., Vascotto, A., Veronese, M., Visintini, R., Zaccaria, M., Zangrando, D. & Zangrando, M. (2012). Nat. Photon. 6, 699-704.]; Schreiber et al., 2012[Schreiber, S., Faatz, B., Feldhaus, J., Honkavaara, K., Treusch, R. & Vogt, M. (2012). Proceedings of the 34th International Free-Electron Laser Conference (FEL2012), 26-31 August 2012, Nara, Japan, p. 37. MOPD01.]; Ishikawa et al., 2012[Ishikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., Goto, S., Hanaki, H., Hara, T., Hasegawa, T., Hatsui, T., Higashiya, A., Hirono, T., Hosoda, N., Ishii, M., Inagaki, T., Inubushi, Y., Itoga, T., Joti, Y., Kago, M., Kameshima, T., Kimura, H., Kirihara, Y., Kiyomichi, A., Kobayashi, T., Kondo, C., Kudo, T., Maesaka, H., Maréchal, X. M., Masuda, T., Matsubara, S., Matsumoto, T., Matsushita, T., Matsui, S., Nagasono, M., Nariyama, N., Ohashi, H., Ohata, T., Ohshima, T., Ono, S., Otake, Y., Saji, C., Sakurai, T., Sato, T., Sawada, K., Seike, T., Shirasawa, K., Sugimoto, T., Suzuki, S., Takahashi, S., Takebe, H., Takeshita, K., Tamasaku, K., Tanaka, H., Tanaka, R., Tanaka, T., Togashi, T., Togawa, K., Tokuhisa, A., Tomizawa, H., Tono, K., Wu, S., Yabashi, M., Yamaga, M., Yamashita, A., Yanagida, K., Zhang, C., Shintake, T., Kitamura, H. & Kumagai, N. (2012). Nat. Photon. 6, 540-544.]; Harmand et al., 2013[Harmand, M., Coffee, R., Bionta, M. R., Chollet, M., French, D., Zhu, D., Fritz, D. M., Lemke, H. T., Medvedev, N., Ziaja, B., Toleikis, S. & Cammarata, M. (2013). Nat. Photon. 7, 215-218.]; Pellegrini et al., 2015[Pellegrini, C., Marinelli, A. & Reiche, S. (2015). Rev. Mod. Phys. 88, 015006.]). The European XFEL (EuXFEL) in the Hamburg metropolitan area, Germany, is an X-ray source based on a super-conducting linear accelerator which started user operation in fall 2017 (Saldin et al., 2000[Saldin, E. L., Schneidmiller, E. V. & Yurkov, M. V. (2000). The Physics of Free Electron Lasers, 1st ed. Berlin: Springer-Verlag.]; Altarelli et al., 2006[Altarelli, M. et al. (2006). XFEL: The European X-Ray Free-Electron Laser - Technical Design Report. DESY 2006-097. DESY, Hamburg, Germany (doi:10.3204/DESY_06-097).]; Tschentscher et al., 2017[Tschentscher, T., Bressler, C., Grünert, J., Madsen, A., Mancuso, A. P., Meyer, M., Scherz, A., Sinn, H. & Zastrau, U. (2017). Appl. Sci. 2017, 7, 592.]; Decking et al., 2019[Decking, W. et al. (2019). Nat. Photon. Submitted.]). EuXFEL operates with a 10 Hz bunch train structure. Each train can contain up to 2700 pulses. Individual X-ray pulses are of the order of 2 fs to 100 fs in duration, contain energy of the order of several mJ, and are separated by 222 ns (at the nominal intra-train repetition rate of 4.5 MHz). This unique time structure provides not only very high peak brilliance but also the highest average brilliance over all of the other XFEL facilities. There are in total three undulators that can produce self-amplified spontaneous emission (SASE) radiation, among which two hard X-ray undulators, SASE1 and SASE2, generate hard XFEL radiation up to 25 keV while the third undulator, SASE3, provides soft X-rays up to 3 keV.

One important problem in the use of the XFEL beam is the so-called single-shot damage. A large number of photons arrive within less than 100 fs, therefore thermal transport processes cannot remove substantial heat during the pulse, even for excellent heat conductors such as copper or diamond. For focused beam conditions (typically smaller than 50 µm diameter), most materials will vaporize on an ultrafast time scale due to the single XFEL pulse absorption within the X-ray penetration depth. More resistant materials are those with low atomic number where the absorption per atom is low. Most components that are directly exposed to XFEL radiation are therefore made of boron carbide or diamond, e.g. slits, beam stops, shutters, collimators and attenuators. The average power during a train of X-ray pulses can be as high as several kW depending on the energy per pulse and the number of pulses within the train. Diamond is considered as the most optimal material for such applications due to its high thermal conductivity (2052 W mK−1 at 300 K) and low absorption for hard X-rays.

The stochastic nature of SASE FEL radiation gives rise to shot-to-shot fluctuations for most beam properties, including pulse energy, spatial profile, wavefront, pulse duration, temporal profile and spectrum. The X-ray photon diagnostics group (XPD) at the European XFEL provides essential information to the machine for setup, optimization and operation of the accelerator, undulator and X-ray optics (Grünert, 2012[Grünert, J. (2012). European XFEL Technical Report XFEL.EU TR-2012-003. European XFEL, Schenefeld, Germany (doi:10.3204/XFEL.EU/TR-2012-003).]; Grünert et al., 2015[Grünert, J., Koch, A., Kujala, N., Freund, W., Planas, M., Dietrich, F., Buck, J., Liu, J., Sinn, H., Dommach, M. & Molodtsov, S. (2015). Proceedings of the 37th International Free Electron Laser Conference (FEL 2015), 23-28 August 2015, Daejeon, South Korea. WED03.], 2019[Grünert, J., Carbonell, M. P., Dietrich, F., Falk, T., Freund, W., Koch, A., Kujala, N., Laksman, J., Laksman, J., Tiedtke, K., Jastrow, U. F., Sorokin, A., Syresin, E., Grebentsov, A. & Brovko, O. (2019). J. Synchrotron Rad. 26. To be published.]). In particular, the resulting spectrum will vary considerably from shot to shot. In order to monitor these variations, the high-resolution hard X-ray single-shot spectrometer (HIREX diagnostic spectrometer) was installed in the photon tunnel XTD9 of the SASE1 undulator beamline (Kujala et al., 2019[Kujala, N., Freund, W., Koch, A., Planas, M., Liu, J., Dietrich, F. & Grünert, J. (2019). In preparation.]). HIREX is an on-line device, and it contains a linear transmissive diamond diffraction grating to split off a small fraction of the photon beam, a bent Si crystal as a dispersive element, and a MHz-repetition-rate strip detector. In this paper, we report on the fabrication of gratings, measurements of the diffraction efficiency in the various diffraction orders, and efficiency maps over the grating surface, obtained at the P10 beamline of PETRA III at DESY, Hamburg, Germany.

2. Grating fabrication

Free-standing polycrystalline diamond membranes made by chemical vapour deposition (CVD) were used to fabricate the grating structures. Diamond membranes supported by a silicon frame were purchased from Diamond Materials GmbH, Germany. The grating structures were fabricated at the Laboratory for Micro- and Nanotechnology at the Paul Scherrer Institut (PSI), Switzerland, using electron-beam lithography (EBL) and inductively coupled plasma (ICP) etching in an oxygen atmosphere. Figs. 1(a) and 1(b)[link] show a sketch and an image of such a grating. The membrane has a diameter of 5 mm and a thickness of 10 µm and is supported by a 500 µm-thick silicon frame of size 10 mm × 10 mm. The grating lines are produced over a large area of 2 mm × 2 mm, large enough to make alignment convenient and simple, and to accommodate the beam size of the European XFEL photon energy. To avoid collapse of the grating lines during resist development and ICP etching, the grating lines were connected by support structures. The support structures are a set of periodic lines perpendicular to the grating lines, having a pitch that is ten times larger than the grating lines. The diffracted intensity from the support structures is several orders of magnitude smaller than that from the grating lines. Further details about the gratings' fabrication are given elsewhere (David et al., 2011[David, C., Gorelick, S., Rutishauser, S., Krzywinski, J., Vila-Comamala, J., Guzenko, V. A., Bunk, O., Färm, E., Ritala, M., Cammarata, M., Fritz, M. D., Barrett, R., Samoylova, L., Grünert, J. & Sinn, H. (2011). Sci. Rep. 1, 57.]; Karvinen et al., 2012[Karvinen, P., Rutishauser, S., Mozzanica, A., Greiffenberg, D., Juranić, N. P., Menzel, A., Lutman, A., Krzywinski, J., Fritz, D. M., Lemke, H. T., Cammarata, M. & David, C. (2012). Opt. Lett. 37, 5073.]; Makita et al., 2015[Makita, M., Karvinen, P., Zhu, D., Juranic, P., Grünert, J., Cartier, S., Jungmann-Smit, J. H., Lemke, H. T., Mozzanica, A., Nelson, S., Patthey, L., Sikorski, M., Song, S., Feng, Y. & David, C. (2015). Optica, 2, 912-916.], 2017[Makita, M., Karvinen, P., Guzenko, V. A., Kujala, N., Vagovic, P. & David, C. (2017). Microelectron. Eng. 176, 75-78.]). A measurement of the grating efficiency, along with its spatial distribution across the grating area, is essential as feedback for the optimization of the fabrication process. Fig. 2(a)[link] shows a scanning electron microscope (SEM) image of grating lines of size 2 mm × 2 mm and pitch 150 nm. Fig. 2(b)[link] shows an SEM image of gratings taken at a 45° tilted angle and etched to a depth of 1.2 µm, resulting in an aspect ratio of 16. There is no remaining resist in the SEM image from the fabrication and it was removed before experimental measurements were performed.

[Figure 1]
Figure 1
(a) Sketch of the grating design etched into a free-standing diamond membrane. (b) Image of a grating with grating lines extending over 2 mm × 2 mm on the Si substrate.
[Figure 2]
Figure 2
(a) Top view of an SEM image of the linear grating with a pitch of 150 nm and support structure for stability of the grating lines. (b) Side view SEM image taken at a 45° titled angle of the linear grating with a pitch of 150 nm and a depth of 1.2 µm.

3. Experimental setup

Several linear transmissive gratings with different pitches were fabricated for hard X-rays in the energy range 5–20 keV for the HIREX diagnostic spectrometer. To understand the diffraction efficiencies and the structural homogeneities of the gratings we have performed an experiment at beamline P10 of PETRA III (Kalbfleisch et al., 2011[Kalbfleisch, S., Neubauer, H., Krüger, S. P., Bartels, M., Osterhoff, M., Mai, D. D., Giewekemeyer, K., Hartmann, B., Sprung, M., Salditt, T., McNulty, I., Eyberger, C. & Lai, B. (2011). AIP Conf. Proc. 1365, 96-99.]). We have tested a grating with a pitch of 150 nm at three different photon energies, 6 keV, 8 keV and 12 keV. Fig. 3[link] shows a sketch of the beamline and Fig. 4[link] shows a photograph of the Coherent Diffraction Imaging (CDI) setup in the experimental hutch EH2 at the P10 beamline. The beamline has a silicon (111) double-crystal monochromator (DCM). The beam size is defined by slits which are located downstream of the DCM. The gratings were mounted on a holder which itself was mounted on a DN100 flange and placed in the sample chamber. For the measurements an unfocused beam of area 100 µm × 100 µm was adjusted by the slits. The 2D Lambda detector developed at DESY was used for data collection of diffraction orders from the gratings. The Lambda detector is based on the Medipix3 chipset and has 55 µm × 55 µm pixel size and an area of 1536 pixels × 512 pixels (84.5 mm × 28.2 mm) and a frame rate up to 2 kHz. The data were acquired with an exposure time of 100 ms. A beam stop was placed in front of the detector to block the direct beam. The detector was placed outside the vacuum system. A flight tube with a 100 µm-thick Kapton window at the exit flange provided an evacuated beam path between sample chamber and detectors. The zeroth-order and first-order diffraction efficiencies were measured using a photodiode. In front of the photodiode a circular aperture of diameter 100 µm was mounted on a linear stage, allowing measurement of the intensity from the diffraction order by scanning its position. The 2D Lambda detector was used to acquire the higher diffraction orders from the gratings. In order to achieve good separation between the zeroth order and higher orders, the detectors were placed 5 m downstream of the gratings.

[Figure 3]
Figure 3
Sketch of the P10 beamline for measuring the grating diffraction efficiencies.
[Figure 4]
Figure 4
Photographs of the experimental hutch 2 of beamline P10 and the sample vacuum chamber (with installed gratings), flight tube and Lambda detector.

4. Results

The diffraction efficiencies and the structural homogeneities of the gratings are of crucial importance to better understand and further optimize the fabrication process. Knowledge of these parameters is also crucial to model the grating performance and correctly adjust the absolute photon intensities in the diffraction orders for the beam splitter applications at the diagnostic spectrometer. The diffraction efficiency and homogeneity of the grating surfaces with pitches of 150 nm were tested for three different photon energies, 6 keV, 8 keV and 12 keV. The linear transmissive CVD diamond grating was placed normal to the incident beam and 2% of the beam was absorbed by the diamond membrane of the gratings at 6 keV. The grating lines were oriented in the vertical direction, so that the diffracted beams were deflected in the horizontal plane. The gratings were placed in a vacuum chamber with a vacuum level of the order of 10−7 mbar; at the detector position the separations between the zeroth-order and first-order diffracted beam was 6.8 mm at 6 keV and 3.3 mm at 12 keV photon energy. The separation of orders with respect to the direct beam (zeroth order) can be calculated when the pitch of the gratings, the photon energy and the distance between gratings and detector are known. In order to investigate the homogeneity of the grating structures we have scanned the grating surface by moving the sample holder over an area of 2 mm × 2 mm and acquired data with the photodiode. Fig. 5(a)[link] shows the efficiency mesh in the first-order diffraction at a photon energy of 6 keV. The efficiency variation across most of the grating surface is within 20%. However, the left bottom edge of the gratings has a 55% lower efficiency than measured at the centre of the surface, as shown in Fig. 5(a)[link]. This is due to the fact that the diamond membranes are not flat but exhibit a curvature, which results in errors in the focus settings during e-beam lithography. Errors in the focus setting have an effect on the electron-beam size and writing fields stitching accuracy. This then causes local variations of the grating line width and depth, or the duty cycle. Fig. 5(b)[link] shows the measured and calculated diffraction efficiency as a function of photon energy for a grating with 150 nm pitch. The calculations for diffraction efficiency used publicly available data from the Berkeley Laboratory Centre for X-ray optics (https://henke.lbl.gov/). The diffraction efficiency was measured by the photodiode. The measured diffraction efficiency is 37% of the calculated values. This discrepancy in efficiency values between measurement and calculation arises from the fact that in theoretical calculations the structures consist of perfect binary squares and the fabrication imperfections are not taken into account. Fig. 6(a)[link] shows the higher-order diffractions. The zeroth-order beam is blocked by a beamstop to protect the Lambda detector and to see the low-intensity signal coming from the diffraction orders. Data were collected for a photon energy of 6 keV. The diffraction spots are spread horizontally and are visible up to the fifth order of diffraction. The finer-spaced diffraction spots along the vertical direction are caused by the support structures of the gratings, which are typically 80% less in intensity than those coming from the corresponding first-order diffraction spot. In between the diffraction orders there is another very weak intensity signal which is due to the intrinsic scattering function of the grating. Fig. 6(b)[link] shows the intensity of the higher diffraction orders obtained from line profiles through the Lambda detector image. The negative-order diffraction intensity is slightly larger than that on the positive-order side which is mainly due to the fact that the gratings are not perfectly aligned to the incoming X-ray beam. We aligned the gratings perpendicular to the incident X-ray beam. However, we suspect there is slight misalignment with respect to the incident angle around the vertical axis which would explain the fact that the negative orders are slightly larger than the positive-order diffraction.

[Figure 5]
Figure 5
(a) Efficiency map of the first-order diffraction from gratings with 150 nm pitch at a photon energy of 6 keV. (b) Diffraction efficiency as a function of photon energy. The calculated values are shown as a black line. Measured diffraction efficiencies are shown as blue triangles.
[Figure 6]
Figure 6
(a) Lambda detector spatial data showing the grating diffraction at a distance of 5 m downstream of the grating. The zeroth-order beam is blocked by a beam stop. The higher-order diffractions are spread in the horizontal direction. The vertical diffraction spots are due to support structures in the gratings. Those spots are very low in intensity with respect to the horizontal diffraction orders. (b) Intensity line profile from the Lambda detector image across the grating diffraction orders up to the fourth order.

5. Summary

Linear transmissive CVD diamond gratings were tested as beam splitters at the P10 beamline at PETRA III, DESY. The results show that fabricated gratings with 150 nm pitch have homogeneous grating structures. The homogeneity of the grating structure measurement will be used as feedback information to further optimize the e-beam lithography parameters for grating fabrication. In particular, we can use the measurements to adjust the proper focusing of the electron beam across the curved diamond membrane surface. The measurement parameters are also used as feedback for operation of the gratings in the HIREX spectrometer. The diffraction efficiencies into first-order diffraction are sufficient to use these gratings as beam splitters. Non-invasive spectral measurements of the XFEL beam and the zeroth-order beam will be delivered to the scientific endstations for experiments. The efficiency variation map helps us in aligning the gratings to the beam to a position with homogeneous grating structure. The gratings are mounted on the linear manipulator which allows them to be aligned relative to the incoming X-rays such that impinge on the uniform grating structure which is obtained from the measurement results at the P10 beamline. The tested gratings are now installed in the HIREX diagnostic spectrometer. In the HIREX spectrometer we have installed 150 nm and 200 nm pitch gratings. The 200 nm pitch grating shows comparable results with the 150 nm grating. Depending on the photon energy, we plan to use the different grating pitches: the 200 nm pitch gratings will be used for the photon energy range 3–5 keV, while the 150 nm pitch gratings will be used for 5–20 keV. This diagnostic spectrometer is installed in the photon tunnel XTD9 of the SASE1 undulator beamline. The HIREX spectrometer is an online device using diamond diffraction gratings of different pitches as beam splitters. A silicon crystal with fixed bending radius is used as the energy-dispersive element. A Gotthard detector (Mozzanica et al., 2011[Mozzanica, A., Bergamaschi, A., Dinapoli, R., Graafsma, H., Henrich, B., Kraft, P., Johnson, I., Lohmann, M., Schmitt, B. & Shi, X. (2011). Nucl. Instrum. Methods Phys. Res. A, 633, S29-S32.]) with MHz rate acquisition capability is used for recording spectra at high pulse repetition rates, whereas a Photonic Science sCMOS camera is used at low repetition rates. The characterization of diamond gratings using the high-resolution small-angle X-ray scattering setup at P10 beamline provides an efficient approach for non-invasive studies of such optics and feedback for manufacturing of high-quality X-ray optics.

Footnotes

1This article will form part of a virtual special issue containing papers presented at the PhotonDiag2018 workshop.

Acknowledgements

NK would like to thank P. Karvinen from Finnlitho Ltd for discussions about the project, Jens Rehanek from PSI Switzerland for discussions during the initial phase of the project, and Eckhard Wörner from Diamond Materials GmbH, Freiburg, Germany, for providing the free-standing diamond membrane. All the authors would like to thank the P10 beamline staff for their support during the beam time. We also gratefully acknowledge the European XFEL management board members for supporting and funding this project.

References

First citationAllaria, E., Appio, R., Badano, L., Barletta, W., Bassanese, S., Biedron, S. G., Borga, A., Busetto, E., Castronovo, D., Cinquegrana, P., Cleva, S., Cocco, D., Cornacchia, M., Craievich, P., Cudin, I., D'Auria, G., Dal Forno, M., Danailov, M. B., De Monte, R., De Ninno, G., Delgiusto, P., Demidovich, A., Di Mitri, S., Diviacco, B., Fabris, A., Fabris, R., Fawley, W., Ferianis, M., Ferrari, E., Ferry, S., Froehlich, L., Furlan, P., Gaio, G., Gelmetti, F., Giannessi, L., Giannini, M., Gobessi, R., Ivanov, R., Karantzoulis, E., Lonza, M., Lutman, A., Mahieu, B., Milloch, M., Milton, S. V., Musardo, M., Nikolov, I., Noe, S., Parmigiani, F., Penco, G., Petronio, M., Pivetta, L., Predonzani, M., Rossi, F., Rumiz, L., Salom, A., Scafuri, C., Serpico, C., Sigalotti, P., Spampinati, S., Spezzani, C., Svandrlik, M., Svetina, C., Tazzari, S., Trovo, M., Umer, R., Vascotto, A., Veronese, M., Visintini, R., Zaccaria, M., Zangrando, D. & Zangrando, M. (2012). Nat. Photon. 6, 699–704.  Web of Science CrossRef CAS Google Scholar
First citationAltarelli, M. et al. (2006). XFEL: The European X-Ray Free-Electron Laser - Technical Design Report. DESY 2006–097. DESY, Hamburg, Germany (doi:10.3204/DESY_06-097).  Google Scholar
First citationDavid, C., Gorelick, S., Rutishauser, S., Krzywinski, J., Vila-Comamala, J., Guzenko, V. A., Bunk, O., Färm, E., Ritala, M., Cammarata, M., Fritz, M. D., Barrett, R., Samoylova, L., Grünert, J. & Sinn, H. (2011). Sci. Rep. 1, 57.  CrossRef PubMed Google Scholar
First citationDecking, W. et al. (2019). Nat. Photon. Submitted.  Google Scholar
First citationEmma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F., Ding, Y., Dowell, D., Edstrom, S., Fisher, A., Frisch, J., Gilevich, S., Hastings, J., Hays, G., Hering, P., Huang, Z., Iverson, R., Loos, H. M., Messerschmidt, M., Miahnahri, A., Moeller, S., Nuhn, H., Pile, G., Ratner, D., Rzepiela, J., Schultz, D., Smith, T., Stefan, P., Tompkins, H., Turner, J., Welch, J., White, W., Wu, J., Yocky, G. & Galayda, J. (2010). Nat. Photon. 4, 641–647.  CrossRef CAS Google Scholar
First citationGrünert, J. (2012). European XFEL Technical Report XFEL.EU TR-2012–003. European XFEL, Schenefeld, Germany (doi:10.3204/XFEL.EU/TR-2012–003).  Google Scholar
First citationGrünert, J., Carbonell, M. P., Dietrich, F., Falk, T., Freund, W., Koch, A., Kujala, N., Laksman, J., Laksman, J., Tiedtke, K., Jastrow, U. F., Sorokin, A., Syresin, E., Grebentsov, A. & Brovko, O. (2019). J. Synchrotron Rad. 26. To be published.  Google Scholar
First citationGrünert, J., Koch, A., Kujala, N., Freund, W., Planas, M., Dietrich, F., Buck, J., Liu, J., Sinn, H., Dommach, M. & Molodtsov, S. (2015). Proceedings of the 37th International Free Electron Laser Conference (FEL 2015), 23–28 August 2015, Daejeon, South Korea. WED03.  Google Scholar
First citationHarmand, M., Coffee, R., Bionta, M. R., Chollet, M., French, D., Zhu, D., Fritz, D. M., Lemke, H. T., Medvedev, N., Ziaja, B., Toleikis, S. & Cammarata, M. (2013). Nat. Photon. 7, 215–218.  Web of Science CrossRef CAS Google Scholar
First citationIshikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., Goto, S., Hanaki, H., Hara, T., Hasegawa, T., Hatsui, T., Higashiya, A., Hirono, T., Hosoda, N., Ishii, M., Inagaki, T., Inubushi, Y., Itoga, T., Joti, Y., Kago, M., Kameshima, T., Kimura, H., Kirihara, Y., Kiyomichi, A., Kobayashi, T., Kondo, C., Kudo, T., Maesaka, H., Maréchal, X. M., Masuda, T., Matsubara, S., Matsumoto, T., Matsushita, T., Matsui, S., Nagasono, M., Nariyama, N., Ohashi, H., Ohata, T., Ohshima, T., Ono, S., Otake, Y., Saji, C., Sakurai, T., Sato, T., Sawada, K., Seike, T., Shirasawa, K., Sugimoto, T., Suzuki, S., Takahashi, S., Takebe, H., Takeshita, K., Tamasaku, K., Tanaka, H., Tanaka, R., Tanaka, T., Togashi, T., Togawa, K., Tokuhisa, A., Tomizawa, H., Tono, K., Wu, S., Yabashi, M., Yamaga, M., Yamashita, A., Yanagida, K., Zhang, C., Shintake, T., Kitamura, H. & Kumagai, N. (2012). Nat. Photon. 6, 540–544.  Web of Science CrossRef CAS Google Scholar
First citationKalbfleisch, S., Neubauer, H., Krüger, S. P., Bartels, M., Osterhoff, M., Mai, D. D., Giewekemeyer, K., Hartmann, B., Sprung, M., Salditt, T., McNulty, I., Eyberger, C. & Lai, B. (2011). AIP Conf. Proc. 1365, 96–99.  CrossRef Google Scholar
First citationKarvinen, P., Rutishauser, S., Mozzanica, A., Greiffenberg, D., Juranić, N. P., Menzel, A., Lutman, A., Krzywinski, J., Fritz, D. M., Lemke, H. T., Cammarata, M. & David, C. (2012). Opt. Lett. 37, 5073.  CrossRef PubMed Google Scholar
First citationKujala, N., Freund, W., Koch, A., Planas, M., Liu, J., Dietrich, F. & Grünert, J. (2019). In preparation.  Google Scholar
First citationMakita, M., Karvinen, P., Guzenko, V. A., Kujala, N., Vagovic, P. & David, C. (2017). Microelectron. Eng. 176, 75–78.  Web of Science CrossRef CAS Google Scholar
First citationMakita, M., Karvinen, P., Zhu, D., Juranic, P., Grünert, J., Cartier, S., Jungmann-Smit, J. H., Lemke, H. T., Mozzanica, A., Nelson, S., Patthey, L., Sikorski, M., Song, S., Feng, Y. & David, C. (2015). Optica, 2, 912–916.  CrossRef Google Scholar
First citationMozzanica, A., Bergamaschi, A., Dinapoli, R., Graafsma, H., Henrich, B., Kraft, P., Johnson, I., Lohmann, M., Schmitt, B. & Shi, X. (2011). Nucl. Instrum. Methods Phys. Res. A, 633, S29–S32.  Web of Science CrossRef CAS Google Scholar
First citationPellegrini, C., Marinelli, A. & Reiche, S. (2015). Rev. Mod. Phys. 88, 015006.  CrossRef Google Scholar
First citationSaldin, E. L., Schneidmiller, E. V. & Yurkov, M. V. (2000). The Physics of Free Electron Lasers, 1st ed. Berlin: Springer-Verlag.  Google Scholar
First citationSchreiber, S., Faatz, B., Feldhaus, J., Honkavaara, K., Treusch, R. & Vogt, M. (2012). Proceedings of the 34th International Free-Electron Laser Conference (FEL2012), 26–31 August 2012, Nara, Japan, p. 37. MOPD01.  Google Scholar
First citationTschentscher, T., Bressler, C., Grünert, J., Madsen, A., Mancuso, A. P., Meyer, M., Scherz, A., Sinn, H. & Zastrau, U. (2017). Appl. Sci. 2017, 7, 592.  Google Scholar

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds