issue contents
May 2010 issue
Cover illustration: Phase-contrast synchrotron radiation high-resolution radiography images of the fourth digit of the normal frontal limb of a rodent (see Choi, Kim, Choe, Kim, Choi, Jheon and Kim, pages 393-399). Left: overlaying X-ray image of the whole length of the digit clearly shows joints, the alignment of phalanges and the status of the surrounding soft tissue. On the right, a single image allows identification of articular cartilage (arrow), chondrocytes lacunae (L), subchondral bone and bone marrow space (M) of the distal interphalangeal joint (DIP) in detail.
facility information
research papers
Measurement of the complex coherence function and wavefront analysis after different optical elements of a synchrotron beamline such as monochromators and mirrors using a double-grating interferometer.
Open access
The experimental set-up at SpLine (BM25A, ESRF) to measure XMCD by using a diamond X-ray phase retarder to obtain circularly polarized X-rays is described.
Vertical focusing via silicon kinoform lenses has been applied to better use the coherent flux delivered by insertion devices at third-generation synchrotron sources for small-angle X-ray photon correlation spectroscopy experiments.
Magnetic Compton scattering is applied to measure a spin-specific magnetic hysteresis loop.
Open access
A fast 50 µm-accuracy alignment procedure has been developed for the radiosurgery of brain lesions in rats, using microbeam radiation therapy.
The current work shows the calculation and study of an X-ray one-dimensionally focusing system composed of Bragg double-asymmetric-reflecting two-crystal plane parallel plates and a double-concave cylindrical parabolic lens placed in the gap between the plates. The focusing distance is calculated, intensity distribution curves are given in the focusing plane and on the focusing line, and the intensity at the focus point and the longitudinal and transverse sizes of the focus are defined.
The growth kinetics of NiO nanoparticles have been studied by in situ X-ray diffraction using two detection systems: conventional and imaging plate. The evolution of particles size and the diffusion coefficient obtained from X-ray powder diffraction patterns are discussed in terms of the thermal conditions for the two types of detection.
A synchrotron application of an L-shaped laterally graded X-ray multilayer mirror is presented through theoretical ray-tracing using the parameters required for the analyzer system of the IXS beamline at NSLS II.
Open access
An algorithm is developed to extract accurate mass density information from tomography data of a sample embedded in a diamond anvil cell in a high-pressure environment.
In order to reproduce principal B K-edge XANES features in boron-containing minerals, it is sufficient to use a non-self-consistent potential with a relaxed and screened core hole. The core hole affects the spectrum significantly, especially in the pre-edge region.
For the first time, ex vivo XANES investigations have revealed the chemical composition of an ectopic calcification, namely Randall's plaque, positioned at the top of the human papillae in kidney.
The development of a four-channel ionization chamber for parallel measurement of multiple XAFS spectra is described.
The correlation between the chemical shift in X-ray absorption spectroscopy and the valence state in transition-metal compounds is revisited. The strengths and weaknesses of this correlation are discussed in comparison with other empirical and theoretical methods.
Structural changes in a collagen-induced arthritic rodent model were analyzed using high-resolution synchrotron radiation phase-contrast imaging.
Open access
A polycapillary-based wavelength-dispersive spectrometer is reported. The design consideration as well as operation characteristics are presented.
The performance of a four-element Si drift detector for energy-dispersive fluorescence-yield X-ray absorption fine-structure measurements is reported, operating at the National Institute of Standards and Technology beamline X23A2 at the National Synchrotron Light Source.
Ni and Mo K-edge EXAFS measurement using a newly constructed high-pressure chamber revealed the formation of the Ni–Mo–S phase on NiMo/Al2O3 catalysts sulfided at 1.1 MPa and 613 K.
short communications
Open access
A Si saw-tooth refractive lens, fabricated by a dicing process, is demonstrated to focus a 115 keV X-ray beam.
meeting reports
Free
A report on the establishment of the European Synchrotron User Organization (ESUO), a body representing the interests of synchrotron radiation users across Europe.
current events
Free