research papers\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Dual-beam X-ray nano-holotomography

crossmark logo

aHelmholtz-Zentrum Hereon, Max-Planck-Straße 1, 21502 Geesthacht, Germany, bPaul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland, cCenter for X-ray and Nano Science – CXNS, Deutsches Elektronen-Synchrotron – DESY, Notkestraße 85, 22607 Hamburg, Germany, and dHelmholtz Imaging Platform, Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany
*Correspondence e-mail: silja.flenner@hereon.de, johannes.hagemann@desy.de

Edited by A. Momose, Tohoku University, Japan (Received 17 January 2024; accepted 25 April 2024; online 25 June 2024)

Nanotomography with hard X-rays is a widely used technique for high-resolution imaging, providing insights into the structure and composition of various materials. In recent years, tomographic approaches based on simultaneous illuminations of the same sample region from different angles by multiple beams have been developed at micrometre image resolution. Transferring these techniques to the nanoscale is challenging due to the loss in photon flux by focusing the X-ray beam. We present an approach for multi-beam nanotomography using a dual-beam Fresnel zone plate (dFZP) in a near-field holography setup. The dFZP generates two nano-focused beams that overlap in the sample plane, enabling the simultaneous acquisition of two projections from slightly different angles. This first proof-of-principle implementation of the dual-beam setup allows for the efficient removal of ring artifacts and noise using machine-learning approaches. The results open new possibilities for full-field multi-beam nanotomography and pave the way for future advancements in fast holotomography and artifact-reduction techniques.

1. Introduction

Nanotomography is a widely used, destruction-free technique for high-resolution imaging of a wide range of materials, from biological specimens to inorganic materials, allowing researchers to study the structure and composition in 3D. This knowledge is relevant from large metre-sized objects down to the nanoscale where, for example, the porosity of a material influences the overall function of macroscopic objects, e.g. the activity of a catalyst (Alizadehfanaloo et al., 2021[Alizadehfanaloo, S., Garrevoet, J., Seyrich, M., Murzin, V., Becher, J., Doronkin, D. E., Sheppard, T. L., Grunwaldt, J.-D., Schroer, C. G. & Schropp, A. (2021). J. Synchrotron Rad. 28, 1518-1527.]) or the capacity of a battery (Zhou et al., 2020[Zhou, D., Zhang, M., Sun, F., Arlt, T., Frerichs, J. E., Dong, K., Wang, J., Hilger, A., Wilde, F., Kolek, M., Hansen, M. R., Bieker, P., Manke, I., Stan, M. C. & Winter, M. (2020). Nano Energy, 77, 105196.]).

A common imaging technique to obtain this knowledge is near-field holography (NFH) (Cloetens et al., 1999[Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P. & Schlenker, M. (1999). Appl. Phys. Lett. 75, 2912-2914.]). The sample is magnified by a divergent beam which is achieved by placing focusing X-ray optics in front of the sample. In this geometry, the maximum achievable resolution is given by the size of the focal spot. The contrast in the measurement of NFH is achieved by the propagation of the wavefield behind the sample in free space. Therefore, an additional phase-retrieval step is required to obtain the actual phase image of the sample. Usually, holographic projections are recorded at several propagation distances in order to retrieve the phase signal. In recent years however, iterative phase-retrieval approaches using only a single propagation distance (Hagemann et al., 2018[Hagemann, J., Töpperwien, M. & Salditt, T. (2018). Appl. Phys. Lett. 113, 041109.]; Wittwer et al., 2022[Wittwer, F., Hagemann, J., Brückner, D., Flenner, S. & Schroer, C. G. (2022). Optica, 9, 295.]) have been pushed forward which can compete with, or even outperform, standard multi-distance phase retrieval such as contrast-transfer-function-based techniques. Therefore, NFH offers the possibility to acquire full-field projections with only one exposure which allows for time resolved nano-scale imaging (Hagemann et al., 2021[Hagemann, J., Vassholz, M., Hoeppe, H., Osterhoff, M., Rosselló, J. M., Mettin, R., Seiboth, F., Schropp, A., Möller, J., Hallmann, J., Kim, C., Scholz, M., Boesenberg, U., Schaffer, R., Zozulya, A., Lu, W., Shayduk, R., Madsen, A., Schroer, C. G. & Salditt, T. (2021). J. Synchrotron Rad. 28, 52-63.]).

It is common for the projections in full-field imaging to be acquired sequentially, i.e. one at a time.

Breaking this scheme is often motivated by the need for a faster tomogram acquisition, e.g. for fast time-dependent processes (Ruhlandt et al., 2018[Ruhlandt, A., Töpperwien, M., Krenkel, M., Mokso, R. & Salditt, T. (2018). Sci. Rep. 8, 5245.]; Meyer et al., 2021[Meyer, S., Wolf, A., Sanders, D., Iskhakova, K., Ćwieka, H., Bruns, S., Flenner, S., Greving, I., Hagemann, J., Willumeit-Römer, R., Wiese, B. & Zeller-Plumhoff, B. (2021). Metals, 11, 1422.]; Rack et al., 2014[Rack, A., Scheel, M., Hardy, L., Curfs, C., Bonnin, A. & Reichert, H. (2014). J. Synchrotron Rad. 21, 815-818.]; Husband et al., 2022[Husband, R. J., Hagemann, J., O'Bannon, E. F., Liermann, H.-P., Glazyrin, K., Sneed, D. T., Lipp, M. J., Schropp, A., Evans, W. J. & Jenei, Z. (2022). Rev. Sci. Instrum. 93, 053903.]).

In recent years, approaches have been developed which simultaneously illuminate the sample from different angles and thus obtain more than one projection per single exposure (Villanueva-Perez et al., 2018[Villanueva-Perez, P., Pedrini, B., Mokso, R., Vagovic, P., Guzenko, V. A., Leake, S. J., Willmott, P. R., Oberta, P., David, C., Chapman, H. N. & Stampanoni, M. (2018). Optica, 5, 1521.]; Voegeli et al., 2020[Voegeli, W., Kajiwara, K., Kudo, H., Shirasawa, T., Liang, X. & Yashiro, W. (2020). Optica, 7, 514.]; Hoshino et al., 2011[Hoshino, M., Uesugi, K., Pearson, J., Sonobe, T., Shirai, M. & Yagi, N. (2011). J. Synchrotron Rad. 18, 569-574.]; Bellucci et al., 2023[Bellucci, V., Zdora, M.-C., Mikeš, L., Birnšteinová, Š., Oberta, P., Romagnoni, M., Mazzolari, A., Villanueva-Perez, P., Mokso, R., David, C., Makita, M., Cipiccia, S., Uličný, J., Meents, A., Mancuso, A. P., Chapman, H. N. & Vagovič, P. (2023). Opt. Express, 31, 18399-18406.]). This decreases the number of exposures needed to record a tomogram. So far, optical elements have been used to create two (Hoshino et al., 2011[Hoshino, M., Uesugi, K., Pearson, J., Sonobe, T., Shirai, M. & Yagi, N. (2011). J. Synchrotron Rad. 18, 569-574.]; Duarte et al., 2019[Duarte, J., Cassin, R., Huijts, J., Iwan, B., Fortuna, F., Delbecq, L., Chapman, H., Fajardo, M., Kovacev, M., Boutu, W. & Merdji, H. (2019). Nat. Photon. 13, 449-453.]) or multiple (Voegeli et al., 2020[Voegeli, W., Kajiwara, K., Kudo, H., Shirasawa, T., Liang, X. & Yashiro, W. (2020). Optica, 7, 514.]; Sowa & Korecki, 2020[Sowa, K. M. & Korecki, P. (2020). Opt. Express, 28, 23223.]) beams which overlap in the sample plane. Sub-micrometre resolution in a multi-beam setting has only been demonstrated in the soft X-ray regime (Duarte et al., 2019[Duarte, J., Cassin, R., Huijts, J., Iwan, B., Fortuna, F., Delbecq, L., Chapman, H., Fajardo, M., Kovacev, M., Boutu, W. & Merdji, H. (2019). Nat. Photon. 13, 449-453.]) for a single projection using coherent diffractive imaging (Miao et al., 1999[Miao, J., Charalambous, P., Kirz, J. & Sayre, D. (1999). Nature, 400, 342-344.]). In the hard X-ray regime, multi-beam approaches for full-field techniques currently exist only in the micrometre range as they do not make use of any additional X-ray optics for magnification. The main challenge for multi-projection imaging at hard X-ray energies is to reach large deflection angles between the beams. This can be achieved, for example, via additional mirrors or a pair of multi-layer Laue lenses (Maser et al., 2004[Maser, J., Stephenson, G. B., Vogt, S., Yun, W., Macrander, A., Kang, H. C., Liu, C. & Conley, R. (2004). Proc. SPIE, 5539, 185.]; Kubec et al., 2018[Kubec, A., Niese, S., Rosenthal, M., Gluch, J., Burghammer, M., Gawlitza, P., Keckes, J. & Leson, A. (2018). J. Instrum. 13, C04011.]; Flenner et al., 2022b[Flenner, S., Hagemann, J., Storm, M., Kubec, A., Qi, P., David, C., Longo, E., Niese, S., Gawlitza, P., Zeller-Plumhoff, B., Reimers, J., Müller, M. & Greving, I. (2022b). Proc. SPIE, 12242, 122420L.]). Though these are potential solutions to achieve large deflection angles, they require severe alterations in the setup since additional degrees of freedom are needed to align these optics.

In this paper, we use a specially designed dual-beam Fresnel zone plate to focus the incoming X-rays into two beams. We demonstrate the extension of full-field multi-beam imaging to the nanoscale for hard X-rays using two nano-focused beams in a magnified near-field holography setting. These beams form an overlap region at a certain distance behind the focus to create a sufficiently large field of view (FOV). The detector distance is chosen such that the two beams are separated in the detector plane. This multi-beam implementation does not yield large deflection angles, but it is straight forward to implement in the existing setup and does not require additional degrees of freedom to align. By acquiring two projections simultaneously, the setup can be used to efficiently remove noise and ring artifacts in the tomograms via a machine-learning approach.

2. Experimental setting

The experiment was implemented at the nano-imaging setup of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz–Zentrum Hereon. The X-ray beam is monochromized with a channel-cut Si(111) double-crystal monochromator (DCM) to an energy of 11 keV. The nanotomography setup can be configured in a near-field holography mode using a Fresnel zone plate (FZP) as the focusing optics (Flenner et al., 2020a[Flenner, S., Kubec, A., David, C., Storm, M., Schaber, C. F., Vollrath, F., Müller, M., Greving, I. & Hagemann, J. (2020a). Opt. Express, 28, 37514.]). In order to obtain the multiple-beam geometry, a specifically designed dual-beam FZP (dFZP) is used instead of a standard FZP. The integration of this dFZP was straightforward, since no alteration of the setup was necessary. Fig. 1[link](a) shows a schematic top view of the setup. The design of the dFZP consists of two halves of single FZPs. Their centers are separated to create an overlapping region in the sample plane, as shown in Fig. 1[link](b). The respective optical axes of the individual parts of the zone plate have a distance from the center axis of

[d_{\rm fzp} = d_{\rm img}{{z_{01}} \over {z_{12}}}, \eqno (1)]

where z01 and z12 are the sample-to-focus and sample-to-detector distances and dimg is the distance of the two images at the detector. Note that dimg has to be chosen in such a way that the images do not overlap on the detector. The separation of the FZPs is adapted to the target FOV = 50 µm, corresponding to an effective pixel size Δx = 197 nm. This defines the defocus distance z01, in which both beams overlap:

[z_{01} = {{z_{02}} \over {M}} = {{z_{02}\Delta x} \over {px}}, \eqno (2)]

where M is the magnification, px the physical pixel size of the detector and z02 is the focus-to-detector distance. The design parameters of the dFZP are listed in Table 1[link]. The resolution of the setup is determined by the theoretical resolution of the dFZP, but also the coherence properties of the source affect the final resolution. At an energy of 11 keV, the transverse coherence length is 105 µm in the horizontal direction and 600 µm in the vertical direction (Flenner et al., 2020a[Flenner, S., Kubec, A., David, C., Storm, M., Schaber, C. F., Vollrath, F., Müller, M., Greving, I. & Hagemann, J. (2020a). Opt. Express, 28, 37514.]). This impact of partial coherence needs to be considered when describing the size of the focal spots created by the dFZP. This involves the convolution of the geometric image of the source with the point spread function of the optics. Taking this into account, we expect a focal spot size of 231 nm. The manufacturing process of the zone plate is done using electron beam lithography and electroplating (Gorelick et al., 2011[Gorelick, S., Vila-Comamala, J., Guzenko, V. A., Barrett, R., Salomé, M. & David, C. (2011). J. Synchrotron Rad. 18, 442-446.]). The theoretical achievable resolution is approximately 100 nm and is limited by the numerical aperture of the optics. A central stop of 100 µm-thick tungsten is placed between both parts of the dFZP in order to block the direct beam. The order-sorting apertures are mounted in the focal plane to block the direct beam and higher diffraction orders of the dFZP.

Table 1
Summary of dFZP parameters

Parameter Value
Diameter of parent FZP, d 418 µm
Outermost zone width, Δrn 61.4 nm
Theoretical spot size 197 nm
Focal length, f 228.3 mm
Angle between beams (design), α 1.14 mrad
Angle between beams (measured), α 1.22 mrad ± 0.17 mrad
Distance between FZP centers, dFZP 62 µm
Gap between FZPs, g 162.3 µm
[Figure 1]
Figure 1
Multi-beam setup at P05. (a) Top view of the beam path. The beams overlap in the sample region. (b) Frontal view on the dual-beam FZP. The two centers of the parent FZPs are indicated by red dots. A summary of the experimental parameters is given in Table 1[link].

An Si-based photon counting Xspectrum LAMBDA 750k with a pixel size of 55 µm is used as the detector (Flenner et al., 2023[Flenner, S., Hagemann, J., Wittwer, F., Longo, E., Kubec, A., Rothkirch, A., David, C., Müller, M. & Greving, I. (2023). J. Synchrotron Rad. 30, 390-399.]). This detector consists of 12 individual chips of 256 pixels × 256 pixels arranged on a 2 × 6 grid. As the gaps between the chips are covered by larger pixels which are split into three pixels in the detector software, the final size of LAMBDA is 1556 pixel × 516 pixels or 85.57 mm × 28.38 mm. The large area of the detector allows to simultaneously capture the image of both beams. To achieve high resolutions with the large pixels of the LAMBDA detector, a high magnification in the X-ray regime is realized by the geometry of the setup. Therefore, the dFZP was designed such that the two beams overlap 70.66 mm behind the focus.

The experimental distances differ slightly from the design values (Table 2[link]). In the actual experiment, the focus-to-sample distance z01 was decreased such that a higher magnification was achieved. Given the sample-to-detector distance z12 = 20 735 mm, this corresponds to an effective pixel size of 133 nm.

Table 2
Summary of the imaging geometry

Parameter Design value Experiment
Defocus distance, z01 71.66 mm 50.29 mm
Sample-to-detector distance, z12 19928 mm 20735 mm
Detector distance, z02 20000 mm 20785 mm
Detector pixel size 55 µm 55 µm
Distances images at the detector, dimg 17.3 mm 18.0 mm
Magnification 280× 413×
Effective pixel size, Δx 197 nm 133 nm
Fresnel number 4.9 × 10−3 3.1 × 10−3

3. Data acquisition and processing

A spider attachment hair was used as a test object for a tomographic scan (Schaber et al., 2019[Schaber, C. F., Flenner, S., Glisovic, A., Krasnov, I., Rosenthal, M., Stieglitz, H., Krywka, C., Burghammer, M., Müller, M. & Gorb, S. N. (2019). J. R. Soc. Interface. 16, 20180692.]; Flenner et al., 2020b[Flenner, S., Schaber, C. F., Krasnov, I., Stieglitz, H., Rosenthal, M., Burghammer, M., Gorb, S. N. & Müller, M. (2020b). Adv. Mater. 32, 2002758.]). These hairs are located on the feet of spiders, enabling them to walk upside-down. It typically has a diameter of 5 µm to 15 µm and fine attachment elements with a diameter of 100 nm to 300 nm. As it is also a very low-absorbing sample, it is a perfect test sample for phase-contrast methods at the nanoscale (Flenner et al., 2020a[Flenner, S., Kubec, A., David, C., Storm, M., Schaber, C. F., Vollrath, F., Müller, M., Greving, I. & Hagemann, J. (2020a). Opt. Express, 28, 37514.]). The spider attachment hair was placed in the overlap area behind the dFZP, and subsequently rotated to measure a set of 900 projections in the range 0° to 180°, corresponding to 1800 tomographic projections in the case of our dFZP illumination.

The angle α between the beams was measured with a flat silicon substrate. Its surface was aligned parallel with one of the beams by minimizing its width, then it was tilted so that the image became smallest in the other beam. The measurement was done with a step width of 0.01° (0.17 mrad). This way we found an angle α between the two beams of 1.22 mrad ± 0.17 mrad. Taking into account the large measurement error, the measured value is in good agreement with the design value of 1.14 mrad.

The data processing involves several steps. First, the acquired projections need to be flat-field corrected. The flat-field variation was extracted from 120 empty beam images, i.e. images of the illumination without a sample in the beam. These images were used as input for the principal component analysis from which 40 components were extracted and used to calculate the best-fitting flat field. Due to the very noisy border regions of the flat-field corrected `compound' hologram, the two images were reconstructed separately by applying a mask with Gaussian fading on the respective hologram.

In the second step, the phase retrieval is performed on the flat-field corrected data. Here, an iterative projection-based phase-retrieval process in a refractive representation was used, as described by Wittwer et al. (2022[Wittwer, F., Hagemann, J., Brückner, D., Flenner, S. & Schroer, C. G. (2022). Optica, 9, 295.]). Being a pure phase object, the spider hair is straightforward to reconstruct as the absorption can be set to zero. Certain constraints were applied to the data: on the one hand, the measured X-ray intensity is used as a data constraint; on the other hand, the projected phase shift of the sample is restricted to the range [−∞, 0]. As an additional constraint, a self-refining support was applied starting in iteration 70. First, a threshold on the current iterate on the modulus of the reconstructed phases of 0.03 rad is applied, followed by an erosion with a diameter of 3 pixels to remove clusters of stray pixels. Afterwards, eroded outlines are restored with a 10 pixel-diameter dilatation. This yields the support for the following five iterations. The reconstruction result is obtained after 850 iterations. The reconstruction was implemented in the HoloTomoToolbox (Lohse et al., 2020a[Lohse, L., Robisch, A.-L., Töpperwien, M., Maretzke, S., Krenkel, M., Hagemann, J. & Salditt, T. (2020a). Holotomotoolbox, https://gitlab.gwdg.de/irp/holotomotoolbox.],b[Lohse, L. M., Robisch, A.-L., Töpperwien, M., Maretzke, S., Krenkel, M., Hagemann, J. & Salditt, T. (2020b). J. Synchrotron Rad. 27, 852-859.]). The described phase-retrieval scheme is applied to all projections of the tomographic dataset.

In a third step, these data are used to perform the tomographic reconstruction. Prior to the reconstruction, the projections are aligned to each other using an iterative re-projection algorithm, also available in the HoloTomoToolbox. The tomographic reconstruction was then performed using the gridrec algorithm with a Shepp–Logan filter implemented in Tomopy (Gürsoy et al., 2014[Gürsoy, D., De Carlo, F., Xiao, X. & Jacobsen, C. (2014). J. Synchrotron Rad. 21, 1188-1193.]).

4. Results

The multi-beam near-field holography method was successfully implemented at the nanotomography setup at P05. Fig. 2[link](a) shows exemplary raw data from LAMBDA. The image shows the left and right first-order beam of the dFZP. The spider hair is visible on both sides at the same time, illuminated from a slightly different angle. The dark spots on the outer rim of the illuminated area stem from imperfections in the manufacturing of the dFZP. In between the focused beams, the attenuated primary beam hits the detector. These artifacts can be removed via principal-component-based flat-field synthesis (van Nieuwenhove et al., 2015[Van Nieuwenhove, V., De Beenhouwer, J., De Carlo, F., Mancini, L., Marone, F. & Sijbers, J. (2015). Opt. Express, 23, 27975.]; Hagemann et al., 2021[Hagemann, J., Vassholz, M., Hoeppe, H., Osterhoff, M., Rosselló, J. M., Mettin, R., Seiboth, F., Schropp, A., Möller, J., Hallmann, J., Kim, C., Scholz, M., Boesenberg, U., Schaffer, R., Zozulya, A., Lu, W., Shayduk, R., Madsen, A., Schroer, C. G. & Salditt, T. (2021). J. Synchrotron Rad. 28, 52-63.]), as shown in the flat-field corrected hologram in Fig. 2[link](b). The exposure time was set to 2 s which results in an average flux per pixel of 500 photons pixel−1 s−1. The efficiency of this proof-of-principle dFZP is comparatively low. For comparison, a standard gold FZP (300 µm diameter) of better quality yields 2000 photons pixel−1 s−1 (Flenner et al., 2023[Flenner, S., Hagemann, J., Wittwer, F., Longo, E., Kubec, A., Rothkirch, A., David, C., Müller, M. & Greving, I. (2023). J. Synchrotron Rad. 30, 390-399.]). However, the dFZP can, in principle, also be manufactured with the same structure height as conventional FZPs, yielding a comparable efficiency. Fig. 3[link] shows the phase reconstructions obtained from the left [Fig. 3[link](a)] and right [Fig. 3[link](b)] hologram from the same compound hologram.

[Figure 2]
Figure 2
Example for holographic data acquired with the dual-beam FZP. The images show full frames of the LAMBDA detector. (a) Raw image of the two holograms on the detector. Between these, the primary beam leaks through the central stop, but the intensity of this peak is below the saturation rate of LAMBDA. The black dots on the outer edge of the illuminated areas are caused by imperfections in the dFZP. (b) Flat-field corrected holograms obtained via dynamic flat-field correction.
[Figure 3]
Figure 3
Phase reconstructions of (a) left illumination and (b) right illumination. The two projections are recorded in a single exposure with a difference in projection angle of 1.22 mrad. (c) 3D rendering of the denoised tomographic reconstruction.

By recording a single tomography scan with the dual-beam setup, two sets of projections are acquired simultaneously which are separated by an angle of 1.22 mrad (0.07°). In a standard tomography scan, the angle between neighboring projections depends on the number of pixels, or in the case of region of interest, scans on the size of the object. The Crowther criterion describes the number of projections needed in a tomogram (nproj) and can be formulated as (Crowther et al., 1970[Crowther, R. A., DeRosier, D. J. & Klug, A. (1970). Proc. R. Soc. London. A. Math. Phys. Sci. 317, 319-340.]; Jacobsen, 2018[Jacobsen, C. (2018). Opt. Lett. 43, 4811-4814.]): nproj = π(D/d), where D denotes the size of the object under study and d the resolution. In the case of objects fitting in the FOV and resolutions of two pixels, this simplifies to nproj = π(npix/2), where npix denotes the horizontal number of pixels of the detector. By combining the projections of both sides into a single tomographic stack, undersampling can be avoided. Since in our case only 220 pixels of the detector are used, the Crowther criterion is already fulfilled at an angular separation of approximately 8.7 mrad (0.5°). Therefore, the combination of the two tomograms does not reduce the total number of exposures needed in this particular case.

Currently, the setup is limited by the manufacturing process of the optics. The deflection angle mainly depends on (i) the outer most zone width of the FZP and (ii) the ratio of the written aperture to the diameter of the parent FZP. The first one (i) is limited by the manufacturing: high-efficiency high-resolution FZP for hard X-rays are still challenging to manufacture. The outer most zone width can therefore only be reduced to around 30 nm for 11 keV optics for regular FZP while maintaining a reasonable efficiency. Smaller zone widths are possible but only with lower structure heights (Chao et al., 2009[Chao, W., Kim, J., Rekawa, S., Fischer, P. & Anderson, E. H. (2009). Opt. Express, 17, 17669.]; Mohacsi et al., 2017[Mohacsi, I., Vartiainen, I., Rösner, B., Guizar-Sicairos, M., Guzenko, V. A., McNulty, I., Winarski, R., Holt, M. V. & David, C. (2017). Sci. Rep. 7, 43624.]; Rösner et al., 2018[Rösner, B., Koch, F., Döring, F., Bosgra, J., Guzenko, V. A., Kirk, E., Meyer, M., Ornelas, J. L., Fink, R. H., Stanescu, S., Swaraj, S., Belkhou, R., Watts, B., Raabe, J. & David, C. (2018). Microelectron. Eng. 191, 91-96.]). The second one (ii) on the other hand worsens the resolution, because fewer structures contribute to the focusing. In addition, the coherence length has to be considered when selecting the size of the FZP (Flenner et al., 2020a[Flenner, S., Kubec, A., David, C., Storm, M., Schaber, C. F., Vollrath, F., Müller, M., Greving, I. & Hagemann, J. (2020a). Opt. Express, 28, 37514.]). From these constraints, we estimated a maximum deflection angle of approximately 3.0 mrad (0.17°) at the 30 nm outer most zone width at the same effective pixel size and resolution. With the setup described here, it is not possible to add additional information to the measurement due to the Crowther criterion. For samples exceeding the FOV, i.e. when more projections are required to fulfill the Crowther criterion, this approach can be used to decrease the acquisition time. However, with improving properties of X-ray optics, an increase in the possible deflection angle can be expected in the future. This can already be achieved by combining two crossed multi-layer lenses. In the future, improved lithography technologies will be able to achieve larger angles as well by allowing higher aspect ratios for smaller dimensions or by using higher orders of diffractive optics. Additionally, it would be possible to increase the angle by a combination of different approaches such as combining focusing refractive and diffractive optics and potentially reflective optics.

While improving the time resolution, a high image quality must also be maintained. Ring artifacts and noise are two common obstacles that obscure the image quality in X-ray tomography. These can be reduced using time-consuming scanning protocols or extensive post-processing (Boin & Haibel, 2006[Boin, M. & Haibel, A. (2006). Opt. Express, 14, 12071-12075.]; Pelt & Parkinson, 2018[Pelt, D. M. & Parkinson, D. Y. (2018). Meas. Sci. Technol. 29, 034002.]; Münch et al., 2009[Münch, B., Trtik, P., Marone, F. & Stampanoni, M. (2009). Opt. Express, 17, 8567.]). Among these methods, machine-learning approaches have also been developed which offer a powerful alternative to conventional methods. However, usually only one, artifact or noise, can be reduced at the same time while risking the introduction of additional artifacts (Pelt & Parkinson, 2018[Pelt, D. M. & Parkinson, D. Y. (2018). Meas. Sci. Technol. 29, 034002.]; Prell et al., 2009[Prell, D., Kyriakou, Y. & Kalender, W. A. (2009). Phys. Med. Biol. 54, 3881-3895.]). Machine-learning denoising, for example, can significantly enhance artifacts like ring artifacts (Flenner et al., 2022a[Flenner, S., Bruns, S., Longo, E., Parnell, A. J., Stockhausen, K. E., Müller, M. & Greving, I. (2022a). J. Synchrotron Rad. 29, 230-238.]). On the other hand, ring removal often leads to less contrast and loss of spatial resolution (Prell et al., 2009[Prell, D., Kyriakou, Y. & Kalender, W. A. (2009). Phys. Med. Biol. 54, 3881-3895.]).

Here, the dual-beam setup offers the opportunity to maintain a high image quality and efficiently remove ring artifacts in the tomograms: in a simple approach, the projections are combined to reconstruct a single tomogram. Before reconstruction, the projections of both sides need to be aligned to be able to serve as input for the tomographic reconstruction. In this way, artifacts are averaged and therefore reduced significantly [Fig. 4[link](c)] compared with the single reconstructions [Figs. 4[link](a) and 4[link](b)], but some blurring is introduced due to imperfections of the alignment of the projections.

[Figure 4]
Figure 4
Reconstructed slices of the (a) left and (b) right projections of the spider attachment hair. The ring artifacts especially obscure the image quality. (c) Slice reconstructed by combining left and right projections. (d) Results from the machine-learning approach, applied to the tomogram of the right projections. Noise and ring artifacts are significantly reduced.

A more advanced and very powerful approach utilizes machine learning: the reconstructed tomographic volumes of both sides are aligned and used as the input and reference to train a convolutional neural network, as described by Flenner et al. (2022a[Flenner, S., Bruns, S., Longo, E., Parnell, A. J., Stockhausen, K. E., Müller, M. & Greving, I. (2022a). J. Synchrotron Rad. 29, 230-238.]). As the noise, as well as possible defects and features on the detector are different on both sides, noise and ring artifacts can be efficiently removed at the same time. Fig. 4[link] shows slices of the two aligned tomograms used as the input for training [Figs. 4[link](a) and 4[link](b)], and the output after applying the trained network to the reconstruction of the right projections [Fig. 4[link](d)]. Noise and ring artifacts are successfully removed from the result, whereas in this case the image is less blurred due to imperfect alignment. Overall, this method leads to an improved image quality compared with the pure combination of both sides [Fig. 4[link](c)]. This noise and artifact-free image is key to enable 3D segmentation of the sample [Fig. 3[link](c)] and open doors towards a quantitative analysis.

5. Conclusions and outlook

We have demonstrated the first experimental implementation of a full-field nanotomography setup with two nanofocused beams that can achieve 133 nm voxel resolution. In this proof-of-concept experiment, we used an FZP design with two beam-forming elements (dFZP) with overlapping beams in the sample plane. The possible applications of this concept are versatile and bear large potential in the development of fast holotomography and for the elimination of noise and ring artifacts.

In the current study, both beams had the same optical properties. Extending the demonstrated principle using the additional information gained by simultaneous recording offers great potentials which can be exploited via different approaches: in NFH, a variation of defocus can yield additional information that can be used to stabilize the phase-retrieval process. This can be achieved by changing the focal length of one of the elements of the dFZP. Such a dFZP design allows us to measure holograms with two propagation distances simultaneously with a single exposure. In this case, the design of the FZPs can easily be adapted.

Another direction of development is to create more beams with larger deflection angles (Voegeli et al., 2020[Voegeli, W., Kajiwara, K., Kudo, H., Shirasawa, T., Liang, X. & Yashiro, W. (2020). Optica, 7, 514.]; Villanueva-Perez et al., 2018[Villanueva-Perez, P., Pedrini, B., Mokso, R., Vagovic, P., Guzenko, V. A., Leake, S. J., Willmott, P. R., Oberta, P., David, C., Chapman, H. N. & Stampanoni, M. (2018). Optica, 5, 1521.]). This is not as straightforward, since it would require additional deflection of the beam with mirrors, which increases the complexity of the setup. Scanning-based imaging as far-field ptychography (Lyubomirskiy et al., 2022[Lyubomirskiy, M., Wittwer, F., Kahnt, M., Koch, F., Kubec, A., Falch, K. V., Garrevoet, J., Seyrich, M., David, C. & Schroer, C. G. (2022). Sci. Rep. 12, 6203.]) demonstrated great benefits from a multi-beam scanning scheme. Similarly, near-field holography can experience such gains of imaging speed which will pave the way towards tomographic movies (García-Moreno et al., 2021[García-Moreno, F., Kamm, P. H., Neu, T. R., Bülk, F., Noack, M. A., Wegener, M., von der Eltz, N., Schlepütz, C. M., Stampanoni, M. & Banhart, J. (2021). Adv. Mater. 33, 2104659.]) at sub-micrometre resolution.

6. Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Footnotes

Current Address: XRnanotech GmbH, Forschungsstrasse 111, 5232 Villigen-PSI, Switzerland.

Acknowledgements

We thank Frank Seiboth for fruitful discussions for this project. We thank Clemens Schaber for providing the spider attachment hair used as a test sample in this study. AK is currently employed at XRnanotech GmbH, which can manufacture the optics presented in this work. Open access funding enabled and organized by Projekt DEAL.

Funding information

This research was supported in part through the Maxwell computational resources operated at DESY. Funding is acknowledged from Deutsche Forschungsgemeinschaft (grant No. 192346071).

References

First citationAlizadehfanaloo, S., Garrevoet, J., Seyrich, M., Murzin, V., Becher, J., Doronkin, D. E., Sheppard, T. L., Grunwaldt, J.-D., Schroer, C. G. & Schropp, A. (2021). J. Synchrotron Rad. 28, 1518–1527.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationBellucci, V., Zdora, M.-C., Mikeš, L., Birnšteinová, Š., Oberta, P., Romagnoni, M., Mazzolari, A., Villanueva-Perez, P., Mokso, R., David, C., Makita, M., Cipiccia, S., Uličný, J., Meents, A., Mancuso, A. P., Chapman, H. N. & Vagovič, P. (2023). Opt. Express, 31, 18399–18406.  CrossRef CAS PubMed Google Scholar
First citationBoin, M. & Haibel, A. (2006). Opt. Express, 14, 12071–12075.  Web of Science CrossRef PubMed Google Scholar
First citationChao, W., Kim, J., Rekawa, S., Fischer, P. & Anderson, E. H. (2009). Opt. Express, 17, 17669.  CrossRef PubMed Google Scholar
First citationCloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P. & Schlenker, M. (1999). Appl. Phys. Lett. 75, 2912–2914.  Web of Science CrossRef CAS Google Scholar
First citationCrowther, R. A., DeRosier, D. J. & Klug, A. (1970). Proc. R. Soc. London. A. Math. Phys. Sci. 317, 319–340.  Google Scholar
First citationDuarte, J., Cassin, R., Huijts, J., Iwan, B., Fortuna, F., Delbecq, L., Chapman, H., Fajardo, M., Kovacev, M., Boutu, W. & Merdji, H. (2019). Nat. Photon. 13, 449–453.  CrossRef CAS Google Scholar
First citationFlenner, S., Bruns, S., Longo, E., Parnell, A. J., Stockhausen, K. E., Müller, M. & Greving, I. (2022a). J. Synchrotron Rad. 29, 230–238.  CrossRef CAS IUCr Journals Google Scholar
First citationFlenner, S., Hagemann, J., Storm, M., Kubec, A., Qi, P., David, C., Longo, E., Niese, S., Gawlitza, P., Zeller-Plumhoff, B., Reimers, J., Müller, M. & Greving, I. (2022b). Proc. SPIE, 12242, 122420L.  Google Scholar
First citationFlenner, S., Hagemann, J., Wittwer, F., Longo, E., Kubec, A., Rothkirch, A., David, C., Müller, M. & Greving, I. (2023). J. Synchrotron Rad. 30, 390–399.  CrossRef CAS IUCr Journals Google Scholar
First citationFlenner, S., Kubec, A., David, C., Storm, M., Schaber, C. F., Vollrath, F., Müller, M., Greving, I. & Hagemann, J. (2020a). Opt. Express, 28, 37514.  Web of Science CrossRef PubMed Google Scholar
First citationFlenner, S., Schaber, C. F., Krasnov, I., Stieglitz, H., Rosenthal, M., Burghammer, M., Gorb, S. N. & Müller, M. (2020b). Adv. Mater. 32, 2002758.  Web of Science CrossRef Google Scholar
First citationGarcía–Moreno, F., Kamm, P. H., Neu, T. R., Bülk, F., Noack, M. A., Wegener, M., von der Eltz, N., Schlepütz, C. M., Stampanoni, M. & Banhart, J. (2021). Adv. Mater. 33, 2104659.  Google Scholar
First citationGorelick, S., Vila-Comamala, J., Guzenko, V. A., Barrett, R., Salomé, M. & David, C. (2011). J. Synchrotron Rad. 18, 442–446.  Web of Science CrossRef IUCr Journals Google Scholar
First citationGürsoy, D., De Carlo, F., Xiao, X. & Jacobsen, C. (2014). J. Synchrotron Rad. 21, 1188–1193.  Web of Science CrossRef IUCr Journals Google Scholar
First citationHagemann, J., Töpperwien, M. & Salditt, T. (2018). Appl. Phys. Lett. 113, 041109.  Web of Science CrossRef Google Scholar
First citationHagemann, J., Vassholz, M., Hoeppe, H., Osterhoff, M., Rosselló, J. M., Mettin, R., Seiboth, F., Schropp, A., Möller, J., Hallmann, J., Kim, C., Scholz, M., Boesenberg, U., Schaffer, R., Zozulya, A., Lu, W., Shayduk, R., Madsen, A., Schroer, C. G. & Salditt, T. (2021). J. Synchrotron Rad. 28, 52–63.  Web of Science CrossRef IUCr Journals Google Scholar
First citationHoshino, M., Uesugi, K., Pearson, J., Sonobe, T., Shirai, M. & Yagi, N. (2011). J. Synchrotron Rad. 18, 569–574.  Web of Science CrossRef IUCr Journals Google Scholar
First citationHusband, R. J., Hagemann, J., O'Bannon, E. F., Liermann, H.-P., Glazyrin, K., Sneed, D. T., Lipp, M. J., Schropp, A., Evans, W. J. & Jenei, Z. (2022). Rev. Sci. Instrum. 93, 053903.  CrossRef PubMed Google Scholar
First citationJacobsen, C. (2018). Opt. Lett. 43, 4811–4814.  Web of Science CrossRef PubMed Google Scholar
First citationKubec, A., Niese, S., Rosenthal, M., Gluch, J., Burghammer, M., Gawlitza, P., Keckes, J. & Leson, A. (2018). J. Instrum. 13, C04011.  CrossRef Google Scholar
First citationLohse, L., Robisch, A.-L., Töpperwien, M., Maretzke, S., Krenkel, M., Hagemann, J. & Salditt, T. (2020a). Holotomotoolbox, https://gitlab.gwdg.de/irp/holotomotoolboxGoogle Scholar
First citationLohse, L. M., Robisch, A.-L., Töpperwien, M., Maretzke, S., Krenkel, M., Hagemann, J. & Salditt, T. (2020b). J. Synchrotron Rad. 27, 852–859.  CrossRef IUCr Journals Google Scholar
First citationLyubomirskiy, M., Wittwer, F., Kahnt, M., Koch, F., Kubec, A., Falch, K. V., Garrevoet, J., Seyrich, M., David, C. & Schroer, C. G. (2022). Sci. Rep. 12, 6203.  CrossRef PubMed Google Scholar
First citationMaser, J., Stephenson, G. B., Vogt, S., Yun, W., Macrander, A., Kang, H. C., Liu, C. & Conley, R. (2004). Proc. SPIE, 5539, 185.  CrossRef Google Scholar
First citationMeyer, S., Wolf, A., Sanders, D., Iskhakova, K., Ćwieka, H., Bruns, S., Flenner, S., Greving, I., Hagemann, J., Willumeit-Römer, R., Wiese, B. & Zeller-Plumhoff, B. (2021). Metals, 11, 1422.  CrossRef Google Scholar
First citationMiao, J., Charalambous, P., Kirz, J. & Sayre, D. (1999). Nature, 400, 342–344.  Web of Science CrossRef CAS Google Scholar
First citationMohacsi, I., Vartiainen, I., Rösner, B., Guizar-Sicairos, M., Guzenko, V. A., McNulty, I., Winarski, R., Holt, M. V. & David, C. (2017). Sci. Rep. 7, 43624.  Web of Science CrossRef Google Scholar
First citationMünch, B., Trtik, P., Marone, F. & Stampanoni, M. (2009). Opt. Express, 17, 8567.  PubMed Google Scholar
First citationPelt, D. M. & Parkinson, D. Y. (2018). Meas. Sci. Technol. 29, 034002.  Web of Science CrossRef Google Scholar
First citationPrell, D., Kyriakou, Y. & Kalender, W. A. (2009). Phys. Med. Biol. 54, 3881–3895.  Web of Science CrossRef PubMed Google Scholar
First citationRack, A., Scheel, M., Hardy, L., Curfs, C., Bonnin, A. & Reichert, H. (2014). J. Synchrotron Rad. 21, 815–818.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationRösner, B., Koch, F., Döring, F., Bosgra, J., Guzenko, V. A., Kirk, E., Meyer, M., Ornelas, J. L., Fink, R. H., Stanescu, S., Swaraj, S., Belkhou, R., Watts, B., Raabe, J. & David, C. (2018). Microelectron. Eng. 191, 91–96.  Google Scholar
First citationRuhlandt, A., Töpperwien, M., Krenkel, M., Mokso, R. & Salditt, T. (2018). Sci. Rep. 8, 5245.  CrossRef PubMed Google Scholar
First citationSchaber, C. F., Flenner, S., Glisovic, A., Krasnov, I., Rosenthal, M., Stieglitz, H., Krywka, C., Burghammer, M., Müller, M. & Gorb, S. N. (2019). J. R. Soc. Interface. 16, 20180692.  Web of Science CrossRef PubMed Google Scholar
First citationSowa, K. M. & Korecki, P. (2020). Opt. Express, 28, 23223.  CrossRef PubMed Google Scholar
First citationVan Nieuwenhove, V., De Beenhouwer, J., De Carlo, F., Mancini, L., Marone, F. & Sijbers, J. (2015). Opt. Express, 23, 27975.  Web of Science CrossRef PubMed Google Scholar
First citationVillanueva-Perez, P., Pedrini, B., Mokso, R., Vagovic, P., Guzenko, V. A., Leake, S. J., Willmott, P. R., Oberta, P., David, C., Chapman, H. N. & Stampanoni, M. (2018). Optica, 5, 1521.  Google Scholar
First citationVoegeli, W., Kajiwara, K., Kudo, H., Shirasawa, T., Liang, X. & Yashiro, W. (2020). Optica, 7, 514.  CrossRef Google Scholar
First citationWittwer, F., Hagemann, J., Brückner, D., Flenner, S. & Schroer, C. G. (2022). Optica, 9, 295.  Web of Science CrossRef Google Scholar
First citationZhou, D., Zhang, M., Sun, F., Arlt, T., Frerichs, J. E., Dong, K., Wang, J., Hilger, A., Wilde, F., Kolek, M., Hansen, M. R., Bieker, P., Manke, I., Stan, M. C. & Winter, M. (2020). Nano Energy, 77, 105196.  CrossRef Google Scholar

This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds