feature articles
Advanced electron crystallography through model-based imaging
aElectron Microscopy for Materials Research (EMAT), University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp, Belgium, biMinds-Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium, and cDelft Center for Systems and Control (DCSC), Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
*Correspondence e-mail: sandra.vanaert@uantwerpen.be
The increasing need for precise determination of the atomic arrangement of non-periodic structures in materials design and the control of nanostructures explains the growing interest in quantitative
The aim is to extract precise and accurate numbers for unknown structure parameters including atomic positions, chemical concentrations and atomic numbers. For this purpose, statistical parameter estimation theory has been shown to provide reliable results. In this theory, observations are considered purely as data planes, from which structure parameters have to be determined using a parametric model describing the images. As such, the positions of atom columns can be measured with a precision of the order of a few picometres, even though the resolution of the electron microscope is still one or two orders of magnitude larger. Moreover, small differences in average which cannot be distinguished visually, can be quantified using high-angle annular dark-field images. In addition, this theory allows one to measure compositional changes at interfaces, to count atoms with single-atom sensitivity, and to reconstruct atomic structures in three dimensions. This feature article brings the reader up to date, summarizing the underlying theory and highlighting some of the recent applications of quantitative model-based transmisson electron microscopy.Keywords: transmission electron microscopy; quantitative analysis; statistical parameter estimation; experimental design; structure refinement.
1. Introduction
New developments in the field of nanoscience and nanotechnology drive the need for advanced quantitative materials characterization techniques that can be applied to complex nanostructures. The physical properties of nanostructures, including electrical, mechanical and chemical properties, are obviously controlled by the composition and chemical bonding, but also by the exact positions of the atoms. Because of the presence of defects, interfaces and surfaces, the locations of the atoms of nanostructures deviate from their equilibrium bulk positions. This results in strain playing a crucial role in the observed properties. For example, strain induced by the lattice mismatch between a substrate and a superconducting layer grown on top can change the interatomic distances by picometres and can in this manner turn an insulator into a conductor (Locquet et al., 1998). In order to unscramble the structure–properties relation, experimental characterization methods are thus required that can locally determine the unknown structure parameters with sufficient precision (Spence, 1999; Muller & Mills, 1999; Springborg, 2000; Olson, 2000). A precision of the order of 0.01–0.1 Å is needed for the atomic positions (Muller, 1999; Kisielowski, Principe et al., 2001). If we can determine the type and position of the atoms with sufficient precision, the atomic structure can be linked to the physical properties. A common approach to understanding materials properties is the use of theoretical ab initio calculations that allow one to obtain equilibrium atomic positions for a given composition. Once this equilibrium structure has been obtained the physical properties can be computed and predictions of how the material would behave under different environmental conditions, even beyond the capability of any laboratory, can be performed. In this manner, materials science is gradually evolving towards materials design, i.e. from describing and understanding towards predicting materials with interesting properties (Wada, 1996; Olson, 1997, 2000; Reed & Tour, 2000; Browning et al., 2001).
Transmission et al., 2001; Spence, 1999; Henderson, 1995). In this manner, TEM can be used to observe deviations from perfect crystallinity, which is of great importance when studying nanostructures. Fig. 1 gives a schematic overview of two commonly used imaging modes, namely conventional TEM and (STEM). In TEM, the object is illuminated by a parallel incident electron beam which is formed by a set of condenser lenses. An image of the object under study is produced which is then magnified by the remaining imaging lenses and projected onto the viewing device, which is usually a charge-coupled device (CCD) counting the electrons reaching the camera. In the STEM imaging mode, an electron beam is focused to a fine probe that is scanned across the sample in a two-dimensional raster (Crewe, 1968; Crewe et al., 1970; Nellist & Pennycook, 2000). For each probe position, the electrons scattered towards the detector are integrated and displayed as a function of probe position. Different detector geometries are available nowadays. Depending on the collection range of the detector, the dependence of the contrast on the Z will be different, as will the pixel signal-to-noise ratio (Cowley et al., 1995; Hovden & Muller, 2012). Both imaging modes, TEM and STEM, result in two-dimensional projected images of three-dimensional objects.
(TEM) is an excellent technique to study nanostructures. Compared with X-rays, electrons interact very strongly with small volumes of matter, providing local information on the material under study (ZanchetOver the past few years, remarkable high-technology developments in lens design have greatly improved image resolution. Currently, a resolution of the order of 50 pm can be achieved (Haider et al., 1998; Urban, 2008; Jia et al., 2008; Jia, Mi, Faley et al., 2009; Erni et al., 2009). For most atomic types, this exceeds the point where the electrostatic potential of the atoms is the limiting factor. Furthermore, new data collection geometries are emerging that allow one to optimize the experimental settings (Shibata et al., 2010; Hovden & Muller, 2012; Gonnissen et al., 2014; De Backer, De wael et al., 2015; Yang et al., 2015). In addition, detectors behave more and more as ideal quantum detectors. In this manner, the microscope itself becomes less restricting and the quality of the experimental images is set mainly by the unavoidable presence of electron counting noise. However, these images need to be interpreted quantitatively when aiming for precise structural information. Therefore, the focus in (S)TEM research is now gradually moving from obtaining better resolution to improving the precision with which unknown structure parameters, such as the atomic positions and atomic types, can be extracted from (S)TEM images. To reach this goal, the use of statistical parameter estimation theory is of great help (den Dekker et al., 2005; Van Aert et al., 2005, 2009, 2011, 2012, 2013; Bals et al., 2006, 2011, 2012; De Backer et al., 2011; De Backer, Martinez et al., 2015; Martinez, Rosenauer et al., 2014; Kundu et al., 2014).
The purpose of this feature article is twofold. First, a concise overview of the methods that can be applied for the solution of a general type of parameter estimation problem often met in materials characterization or applied science and engineering will be presented. Second, applications of these methods in the field of TEM will be discussed. In these applications, the goal is to determine unknown structure parameters, including atomic positions, chemical concentrations and atomic numbers, as precisely as possible from experimentally recorded images. By means of examples, it will be shown that statistical parameter estimation theory allows one to measure two-dimensional atomic column positions with subpicometre precision, to measure compositional changes at interfaces, to count atoms with single-atom sensitivity and to reconstruct three-dimensional atomic structures.
2. Model-based parameter estimation
In general, the aim of statistical parameter estimation theory is to determine, or more correctly to estimate, unknown physical quantities or parameters on the basis of observations that are acquired experimentally (van den Bos, 2007). In these observations are, for example, the image pixel values recorded using a CCD camera. In this field as well as in many other scientific disciplines, such observations are not themselves the quantities to be measured but are related to the quantities of interest. Often this relation is a known mathematical function derived from physical laws and the quantities to be determined are parameters of this function. For example, if observations are made of a specific object, this parametric model should include all the ingredients needed to perform a computer simulation of the images, i.e. the electron–object interaction, the transfer of the electrons through the microscope and image detection. If models based on first principles cannot be derived, or are too complex for their intended use, simplified empirical models may be used. Some of the model's parameters are the atomic positions and atomic types. The parameter estimation problem then becomes a case of computing the atomic positions and atomic types from images. Statistical parameter estimation theory provides an elegant solution for such problems. Indeed, based on the availability of a parametric model, the unknown structure parameters can be estimated by fitting the model to the experimental images in a procedure, usually called an estimation procedure or estimator. In general, different estimation procedures can be used to estimate the unknown parameters of this model, such as least-squares (LS), least absolute deviations or (ML) estimators (den Dekker et al., 2005, 2013; van den Bos, 2007). In practice, the ML estimator is often used since it is known to be the most precise. This estimator will briefly be reviewed in §2.1, whereas the limits to precision will be discussed in §2.2. For a detailed overview of statistical parameter estimation theory, the reader is referred to den Dekker et al. (2005, 2013), van den Bos (2007), van den Bos & den Dekker (2001), Seber & Wild (1989) and Cramér (1946). The mathematics of statistical parameter estimation theory is given in the highlighted literature and instead this paper concentrates on the general concepts.
2.1. estimation
As one will readily admit, any experiment involves at least some `noise'. This means that, if a particular experiment is repeated under the same conditions, the resulting observations will vary from experiment to experiment and so will the parameter estimates, which are computed on the basis of these observations. If the amount of variation in these estimates is small, we say that the corresponding estimator has a high precision. Accuracy refers to the absence of any systematic deviation of the parameter estimates from the true parameters, and thus to the absence of bias. Because of the unavoidable presence of noise in an experiment, the description of observations by means of only a deterministic parametric mathematical function, as discussed above, is insufficient since it does not account for the random fluctuations caused by the noise in the experiment. An efficient way of describing this behaviour is by means of statistics. This implies that the observations are modelled as so-called stochastic variables. By definition, a stochastic variable is characterized by its probability (density) function [P(D)F], while a set of stochastic variables has a joint P(D)F. Well known P(D)Fs are the ; Herrmann, 1997; Koster et al., 1987). The joint P(D)F defines the expectations, i.e. the mean value of each observation and the fluctuations about these mean values. In a sense, the expectations would be the image pixel values recorded in the absence of noise and they can be modelled using a parametric model. The availability of this parametric model makes it possible to parameterize the P(D)F of the observations, which is of vital importance when quantifying the attainable precision with which unknown structure parameters can be estimated and when determining parameters using the ML estimator.
which applies in the case of electron counting results, and the normal distribution, which can be used when disturbances other than pure counting statistics also contribute or when the electron dose is sufficiently large (Papoulis, 1965Different estimators that can be used to estimate the same unknown parameters will in general result in a different precision. However, the variance of unbiased estimators will never be lower than the so-called Cramér–Rao lower bound (CRLB), which is a theoretical lower bound on the variance (van den Bos, 1982; van den Bos & den Dekker, 2001; den Dekker et al., 2013, 2005). The ML estimator achieves this theoretical lower bound asymptotically, i.e. for an increasing number of observations, and is therefore of practical importance. From the joint P(D)F of the observations, the ML estimator can be derived relatively easily. By substituting the experimental observations in the expression of the P(D)F and considering the structure parameters as random variables, the so-called likelihood function is obtained. estimated parameters are then obtained by maximizing this likelihood function. Note that the ML estimator equals the LS estimator for independent normally distributed observations, which is often a realistic assumption as discussed before (den Dekker et al., 2005).
The search for the maximum of the likelihood function is an iterative numerical procedure and it requires a starting structure for the parameters which is sufficiently close to the real structure to avoid the risk of ending up in a local maximum (Möbus et al., 1998). In applications, the dimension of the parameter space is usually very high. Consequently, it is quite possible that the optimization procedure ends up at a local maximum instead of at the global maximum of the likelihood function, so that the wrong structure parameters are suggested, which introduces bias. To solve this dimensionality problem, i.e. to find a pathway to the maximum in the parameter space, good starting values for the parameters are required (Van Dyck et al., 2003). In other words, the structure has to be resolved. This corresponds to X-ray crystallography, where one first has to resolve the structure and afterwards refine it. Although it is not always trivial to resolve the structure, recent developments in aberration-corrected and the use of to invert the imaging process, such as focal-series reconstruction or electron holography, have resulted in great improvements (Van Dyck & Coene, 1987; Lichte, 1986; Van Dyck et al., 1993; Kirkland et al., 1995; Haigh et al., 2009).
2.2. Attainable precision
When estimating unknown structure parameters in a quantitative manner using statistical parameter estimation theory, we are not so much interested in the
images as such, but rather in the (structural and chemical) information of the sample under study. Images are then considered as data planes, from which sample structure parameters, such as atomic positions, particle sizes and fibre diameters, have to be estimated as precisely as possible. Image quality and resolution are then required to resolve the structure but are no longer the ultimate goal.Often, the question arises of how to measure atomic positions with picometre precision if the resolution of the instrument is `only' 50 pm under optimal conditions. Resolution and precision are very different notions (van den Bos & den Dekker, 2001). In (S)TEM, resolution expresses the ability to distinguish visually between neighbouring atomic columns in an image. Classical resolution criteria, such as Lord Rayleigh's, are derived from the assumption that the human visual system needs a minimum contrast to discriminate two points in its composite intensity distribution (Lord Rayleigh, 1902). Therefore, they are expressed in terms of the width of the point spread function of the (S)TEM imaging system (O'Keefe, 1992). However, if the physics behind the image formation process is known, images no longer need to be interpreted visually. Instead, atomic column positions can be estimated by fitting this known parametric model to an experimental image (den Dekker et al., 2005; Van Aert et al., 2005, 2006). In the absence of noise, this procedure would result in infinitely precise atomic column locations. However, since detected images are never noise-free, model fitting never results in a perfect reconstruction, thus limiting the statistical precision with which the atom locations can be estimated. For continuous parameters, such as the atomic column positions, the attainable precision can be adequately quantified from the joint PDF using the expression for the CRLB. Under certain assumptions, it can then be shown that the attainable precision, expressed in terms of the standard deviation with which the position of a projected atomic column can be estimated, is proportional to the instrumental resolution and inversely proportional to the square root of the number of detected electrons (Bettens et al., 1999; Van Aert, den Dekker, Van Dyck & van den Bos, 2002; Van Aert, den Dekker, van den Bos & Van Dyck, 2002). This explains why the precision to estimate projected atomic column positions can be down to one or a few picometres, although the resolution of modern instruments is 50–100 pm. For instance, if one wants to obtain the position of an atom with a precision of the order of 1 pm, one will need an incident dose of electrons of the order of 1000 e Å−2. In order to push the precision further by a factor of 10, it is necessary to increase the dose by a factor of 100, which will require a very high and/or a long exposure time.
For discrete parameters, such as atomic column types or numbers of atoms, the expression for the CRLB can no longer be used to compute the attainable precision. Recently, it has been shown that statistical detection theory provides an alternative solution to evaluate the performance to estimate discrete parameters (Kay, 2009; den Dekker et al., 2013; Gonnissen et al., 2014; De Backer, De wael et al., 2015). For example, when considering the problem of identifying the (Z) from a STEM image of a single atom, the parameter to be estimated is a positive integer, in which case the CRLB is not defined. However, in the present problem of identifying Z, a priori knowledge concerning possible solutions for the atomic numbers is usually available. In such cases, the question reduces to distinguishing between a finite plausible set of values for the atomic numbers Z given the experimental STEM observations. Detection theory then provides the tools to decide between 2 or more hypotheses – where each hypothesis corresponds to the assumption of a specific Z value – and to predict the probability of assigning an incorrect hypothesis. This expression for the probability of error gives insight into the performance to make a correct decision and the sensitivity of this detection performance to the experimental settings (Gonnissen et al., 2014; den Dekker et al., 2013).
In the following sections, applications of statistical parameter estimation theory in the field of quantitative (S)TEM imaging are outlined.
3. Quantitative atomic column position measurements
Aberration-corrected TEM, exit wave reconstruction methods or combinations of both are often used to measure shifts in atomic positions. Whereas aberration correction has an immediate impact on the resolution of the experimental images, the purpose of exit wave reconstruction is to retrieve the complex electron wavefunction which is formed at the exit plane of the sample under study. In practice, the exit wave is usually reconstructed from a series of images taken at different defocus values, from an electron holographic image or from a series of images recorded with different illuminating beam tilts (Van Dyck & Coene, 1987; Lichte, 1986; Van Dyck et al., 1993; Kirkland et al., 1995; Haigh et al., 2009). Ideally, the exit wave is free from any imaging artifacts, thus enhancing the visual interpretability of the atomic structure. Because of its potential to visualize light atomic columns, such as oxygen or nitrogen, with atomic resolution, exit wave reconstruction has become a powerful tool in high-resolution TEM (Coene et al., 1992; Kisielowski, Hetherington et al., 2001). Although such reconstruction was often considered as a final result used to interpret the structure visually, its combination with quantitative methods nowadays demonstrates its potential to measure atomic column positions precisely (Jia & Thust, 1999; Ayache et al., 2005; Bals et al., 2006). As an example, the quantification of localized displacements at a {110} twin boundary in orthorhombic CaTiO3 will be discussed (Van Aert et al., 2012).
Numerical calculations have shown that domain boundaries in CaTiO3 are mainly ferrielectric with maximum dipole moments at the wall. Twin boundaries of the {110} type in orthorhombic CaTiO3 (space group Pnma) have been imaged along [001] using aberration-corrected TEM in combination with exit wave reconstruction. The phase of the reconstructed exit wave is shown in Fig. 2(a) with a resolution of 0.8 Å. This phase is directly proportional to the projected electrostatic potential of the structure. In order to obtain quantitative numbers for the atomic column positions, statistical parameter estimation is needed (den Dekker et al., 2005; Van Aert et al., 2005; van den Bos & den Dekker, 2001). This allows position measurements of all atomic columns with a precision of a few picometres without being restricted by the information limit of the microscope. Therefore, the phase of the reconstructed exit wave is considered as a data plane from which the atomic column positions are estimated in a statistical way. As discussed in §2, the key to successful application of statistical parameter estimation theory is the availability of a parametric model describing the expectations of the pixel values in the reconstructed phase. Nowadays, the physics behind the electron–object interaction is sufficiently well understood to have such a parameterized expression. The parameters of this function, including the atomic column positions, can then be determined using the LS estimator. From the thus estimated atomic column positions, it has been found that shifts in the Ti atomic positions in the vicinity of the twin wall are present, whereas possible shifts in the Ca atomic positions are too small to be identified (Van Aert et al., 2012). Therefore, this analysis is focused on the off-centring of the Ti atomic positions with respect to the centre of the neighbouring four Ca atomic positions.
First, we average all displacements in planes parallel to the twin wall. Next, we average the results in the planes above with the corresponding planes below the twin wall. This second operation identifies the overall symmetry of the sample, with the twin wall representing a mirror plane. The resulting displacements along and perpendicular to the twin wall are shown in Figs. 2(b) and 2(c), respectively, together with their 90% confidence intervals. In the direction perpendicular to the wall, systematic deviations for Ti of 3.1 pm in the second closest layers pointing towards the twin wall are found. A larger displacement is measured in the direction parallel to the wall in the layers adjacent to the twin wall. The average displacement in these layers is 6.1 pm. In layers further away from the twin wall, no systematic deviations are observed. These experimental results confirm the theoretical predictions (Goncalves-Ferreira et al., 2008). The thickness of the domain wall is about two octahedra. The displacement pattern can be seen as a combination of ferroelectric and antiferroelectric/ferrielectric components. The ferroelectric component is the smaller one and has an effect both parallel and perpendicular to the wall.
We can also calculate the magnitude of the spontaneous polarization of the wall. In the model calculations it was found that the wall polarization is between 0.004 and 0.02 C m−2. Using the experimental value for the displacement of 6 pm, we expect a polarization of the order of 0.04–0.2 C m−2. This value is comparable with the bulk spontaneous polarization of BaTiO3 (0.24 C m−2). The importance of this study is that localized effects can be quantified in combination with statistical parameter estimation theory, proving that ferroelectricity is indeed confined to twin boundaries in a paraelectric matrix.
Another efficient technique to measure shifts in atomic positions is so-called negative spherical aberration imaging, in which the spherical aberration constant Cs is tuned to negative values by employing an aberration corrector (Jia et al., 2003, 2010). Compared with traditional positive Cs imaging, this imaging mode yields a negative phase contrast of the atomic structure, with atomic columns appearing bright against a darker background. For thin objects, this leads to a substantially higher contrast than for the dark-atom images formed under positive Cs imaging. This enhanced contrast has the effect of improving the measurement precision of the atomic positions and explains the use of this technique to measure atomic shifts of the order of a few picometres. Examples are measurements of the width of ferroelectric domain walls in PbZr0.2Ti0.8O3 (Jia et al., 2008), measurements of the coupling of elastic strain fields to polarization in PbZr0.2Ti0.8O3/SrTiO3 epitaxial systems (Jia, Mi, Urban et al., 2009) and measurements of oxygen-octahedron tilt and polarization in LaAlO3/SrTiO3 interfaces (Jia, Mi, Faley et al., 2009).
4. Quantitative composition analysis
Depending on the shape and size of the STEM detector, different signals can be recorded (Cowley et al., 1995; Shibata et al., 2010; Yang et al., 2015). A key imaging mode is high-angle annular dark-field (HAADF) STEM, in which an annular detector is used with a collection range outside the illumination cone. The high-angle scattering thus detected is dominated by Rutherford and thermal diffuse scattering. Therefore, the HAADF signal scales approximately with the square of the Z, hence the name Z-contrast. One of the advantages is thus the possibility of distinguishing visually between chemically different atomic column types. Because of the incoherent imaging nature, the resolution observed in an HAADF STEM image is, to a large extent, determined by the intensity distribution of the illuminating probe. The use of aberration-corrected probe-forming optics currently gives a probe size of the order of 50 pm (Erni et al., 2009). The combination of a high spatial resolution with a high chemical sensitivity makes HAADF STEM a very attractive tool for structure characterization at the atomic level.
Even though HAADF STEM images are to a certain extent interpretable directly, this imaging technique also benefits greatly from quantitative analysis using statistical parameter estimation theory (Van Aert et al., 2009). This is particularly the case when the difference in of distinct atomic column types is small, or if the signal-to-noise ratio becomes poor. A performance measure which is sensitive to the chemical composition is the so-called scattering (Retsky, 1974; Isaacson et al., 1979; Singhal et al., 1997; Van Aert et al., 2009; MacArthur et al., 2013). Using statistical parameter estimation theory, the total intensity of scattered electrons can be quantified atomic column by atomic column using an empirical parameterized incoherent imaging model. The advantage of using scattering cross-sections over other metrics, such as peak intensities, is their robustness to magnification, defocus, source size, astigmatism and other aberrations, and small sample mis-tilt (MacArthur et al., 2013, 2015; Martinez, De Backer et al., 2014). The estimated scattering cross-sections allow us to differentiate between atomic columns with different compositions. As such, differences in average of only 3 can clearly be distinguished in an experimental image, which is impossible by means of visual interpretation alone. This is an important advantage when studying interfaces, as illustrated in the following example.
Fig. 3(a) shows an enlarged area from an experimental HAADF STEM image of an La0.7Sr0.3MnO3–SrTiO3 multilayer structure using an FEI Titan3 50-80 operated at 300 kV. Even though the probe has been corrected for spherical aberration, no visual conclusions could be drawn concerning the sequence of the atomic planes at the interfaces. The refined parameterized model is shown in Fig. 3(b), showing a close match with the experimental data. Fig. 3(c) shows the experimental observations, together with an overlay indicating the estimated positions of the columns and their atomic column types. The composition of the columns away from the interfaces is assumed to be in agreement with the composition in the bulk compounds, whereas the composition of the columns in the planes close to the interface (shown in purple) is unknown. Histograms of the estimated scattering cross-sections of the known columns are presented in Fig. 3(d) and show the random nature of the result. The coloured vertical bands correspond to 90% tolerance intervals. It is important to note that these tolerance intervals do not overlap, meaning that columns, for which the difference in average is only 3 (TiO and MnO) in this example, can clearly be distinguished. Based on this histogram, the composition of the unknown columns can be identified, as shown on the right-hand side of Fig. 3(c). Single-coloured dots are used to indicate columns whose estimated scattering falls inside a tolerance interval, whereas pie charts, indicating the presence of intermixing or diffusion, are used otherwise.
The previous example shows how statistical parameter estimation theory can help to quantify the chemical composition in a relative manner. When aiming for an absolute quantification, intensity measurements relative to the intensity of the incoming electron beam are required (LeBeau et al., 2008; Rosenauer et al., 2009). In this manner, experimental scattering cross-sections can be compared directly with simulated scattering cross-sections (Rosenauer et al., 2009; LeBeau et al., 2010; Martinez, Rosenauer et al., 2014). Reference values are then simulated by carefully matching experimental imaging conditions for a range of sample conditions, including thickness and composition. To illustrate this, Fig. 4(a) shows part of a normalized image of a Pb1.2Sr0.8Fe2O5 compound where the intensities are normalized with respect to the incoming electron beam (Martinez, Rosenauer et al., 2014). By comparing experimental scattering cross-sections for each atomic column with simulated values, the thickness values for the PbO columns and the composition of the SrPbO columns have been determined, as shown in Fig. 4(b). Fig. 4(c) compares the average experimental intensity profile along the vertical direction of the indicated in Fig. 4(b) with a frozen lattice simulation, where the estimated thickness and composition values have been used as input. The overall match between the simulated and experimental image intensities further confirms the results that have been obtained when using the scattering cross-sections approach. However, it should be noted that small deviations between simulated and experimental image intensities can not be avoided because of, for example, remaining uncertainties in the microscope settings such as defocus, source size or astigmatism.
5. Nanoparticle atom counting
The high sensitivity of scattering cross-sections to composition is also an advantage when counting the number of atoms in an atomic column with single-atom precision. To illustrate this, scattering cross-sections have been determined for the atomic columns of a nanosized Ag cluster embedded in an Al matrix (Van Aert et al., 2011). Fig. 5(a) shows an aberration-corrected HAADF STEM image of such clusters viewed along the Using the model-based approach explained above, the parameters of an empirical physics-based model have been estimated in the LS sense. For the cluster in the white boxed region, the refined model is shown in Fig. 5(b). Based on the estimated parameters, scattering cross-sections have been computed for each atomic column and these are shown in the histogram in Fig. 5(d). Since the thickness of the sample can be assumed to be constant over the particle area, substitution of an Al atom by an Ag atom leads to an increase in the estimated intensity. Owing to a combination of experimental detection noise and residual instabilities, broadened – rather than discrete – peaks are observed. Therefore, these results cannot be interpreted directly in terms of the number of atoms in a column. However, by evaluating the so-called integrated classification likelihood (ICL) criterion (McLachlan & Peel, 2000; De Backer et al., 2013), as shown in Fig. 5(e), ten significant peaks are found and their positions are indicated by black dots in Fig. 5(d). From the estimated peak positions, the number of Ag atoms in each atomic column can be quantified, leading to the result shown in Fig. 5(c). This counting procedure has also been applied to the same Ag cluster viewed along the [100] direction, as shown in Figs. 5(f)–5(h). In §6 we will explain how atom-counting results obtained from different zone-axis orientations can be combined to retrieve the three-dimensional atomic structure. For example, the atom counts presented in Figs. 5(c) and 5(h) result in the reconstruction shown in Fig. 5(i).
The most direct method for counting atoms is through comparison with image simulations (LeBeau et al., 2010), but the main drawback with this approach is that systematic errors are difficult to detect. Indeed, the assignment of numbers of atoms will always find a match by comparing experimental scattering values or peak intensities with simulated values. The reliability then depends solely on the accuracy with which, for example, the detector inner and outer angles have been determined and the accuracy with which the simulations have been carried out. In comparison, the statistics-based method used to count the number of atoms shown in Fig. 5 is a simulation-free method. This approach is robust against systematic errors when two conditions are met: the number of experimental scattering cross-sections per unique thickness should be large enough and the spread of scattering cross-sections should be small enough compared with the difference between those of differing thicknesses (De Backer et al., 2013). Ultimately, the simulations-based method and statistics-based method are combined into a hybrid approach. This allows one to compare both methods in an independent way and in this manner the accuracy of the obtained atom counts can be validated (Van Aert et al., 2013; De Backer, Martinez et al., 2015). An example analysis is presented in Fig. 6, showing the atom-counting analysis of an Au nanorod (Van Aert et al., 2013). In this example, the intensities in the HAADF STEM image have been normalized with respect to the incident beam (Rosenauer et al., 2009; Grieb et al., 2012), allowing one to test the accuracy of the counting procedure. This validation step is required since more local minima are present in the ICL criterion shown in Fig. 6(d). Fig. 6(f) shows the experimental mean scattering cross-sections – corresponding to the component locations in Fig. 6(e) – together with the scattering cross-sections estimated from frozen phonon calculations using the STEMsim program under the same experimental conditions (Rosenauer & Schowalter, 2008). The excellent match of the experimental and simulated scattering cross-sections within the expected 5–10% error range validates the accuracy of the obtained atom counts (LeBeau et al., 2010; Rosenauer et al., 2011). The precision of the atom counts is limited by the unavoidable presence of noise in the experimental images, resulting in overlap of the Gaussian components as shown in Fig. 6(e). When the overlap increases, the probability of assigning an incorrect number of atoms will increase. In this example, the probability of having an error of one atom is only 20%, whereas the number of atoms of 80% of all columns can be determined without error. The combination of a simulation-based and a statistics-based method thus allows for reliable atom counting with single-atom sensitivity.
6. Atomic resolution in three dimensions
As described in the previous sections of this feature article, new developments within the field of TEM enable the investigation of nanostructures at the atomic scale. Structural as well as chemical information can be extracted in a quantitative manner. However, such images are mostly two-dimensional projections of a three-dimensional object. To overcome this limitation, three-dimensional imaging by TEM or electron tomography can be used. Atomic resolution in three-dimensions has been the ultimate goal in the field of electron tomography during the past few years. The underlying theory for atomic-resolution tomography has been well understood (Saghi et al., 2009; Jinschek et al., 2008), but nevertheless it has been challenging to obtain the first experimental results. A first approach is based on the acquisition of a limited number of HAADF STEM images that are acquired along different zone axes (Van Aert et al., 2011). As illustrated in §5, advanced quantification methods enable one to count the number of atoms in an atomic column from a two-dimensional (HA)ADF STEM image. In a next step, such atom-counting results can be used as input for discrete tomography. The discreteness that is exploited here is the fact that crystals can be thought of as discrete assemblies of atoms (Jinschek et al., 2008). In this manner, a very limited number of two-dimensional images is sufficient to obtain a three-dimensional reconstruction with atomic resolution. This approach was applied to Ag clusters embedded in an Al matrix, as illustrated in Fig. 5(i) (Van Aert et al., 2011). A three-dimensional reconstruction was obtained using only two HAADF STEM images. An excellent match was found when comparing the three-dimensional reconstruction with additional projection images that were acquired along different zone axes. In a similar manner, the core of a free-standing PbSe–CdSe core–shell nanorod could be reconstructed in three-dimensions (Bals et al., 2011).
The discrete approach that was used in these studies assumes that the atoms are situated on a (fixed) face-centred cubic lattice and that the particle contains no holes. These assumptions provide a decent start for the investigations described above, but deviations from a fixed grid, caused by defects, strain or lattice relaxation, are exactly the parameters that determine the physical properties of nanomaterials. Compressive sensing-based tomography has shown its ability to provide an adequate solution for problems that can be represented in the form of a sparse representation (Donoho, 2006a,b; Saghi et al., 2011; Goris, Bals et al., 2012; Goris, Van den Broek et al., 2012; Leary et al., 2013; Thomas et al., 2013). At the atomic scale, the approach exploits the sparsity of the object, since most of the voxels that need to be reconstructed correspond to vacuum and only a limited number of voxels are occupied by atoms (Goris, Bals et al., 2012). An important advantage of this approach is that the actual positions of the atoms can be revealed without using assumptions concerning the This approach has been applied to reconstruct the structure of Au nanorods (Goris, Bals et al., 2012) and to reconstruct the atom type of individual atoms in Au@Ag nanoparticles, as shown in Fig. 7 (Goris et al., 2013). Such bimetallic particles often provide novel properties compared with their monometallic counterparts (Henglein, 2000; Hodak et al., 2000; Tedsree et al., 2011; Cortie & McDonagh, 2011). To understand these properties, a complete three-dimensional characterization is often required where the exact positioning of the different chemical elements is crucial, especially at the interfaces. Owing to the Z-dependence of HAADF STEM intensities, the position and atom type of each atom have been determined from five high-resolution images acquired along different major zone axes. Using statistical parameter estimation theory, the parameters of an incoherent imaging model have been estimated and the resulting models used as input for the compressive sensing-based algorithm. A detailed analysis of the position and atom type in a core–shell bimetallic nanorod was performed using orthogonal slices through the three-dimensional reconstruction, as shown in Fig. 7 (Goris et al., 2013). Individual Ag and Au atoms can be distinguished, even at the metal/metal interface, by comparing their relative intensities. An intensity profile was acquired along the direction indicated by the white rectangular box in Fig. 7(b) and shown in Fig. 7(d), from which it is clear that Au and Ag atoms can indeed be identified from their intensities using a threshold value. In this manner, each atom in the cross-sections shown in Figs. 7(b) and 7(c) was assigned to be either Ag or Au. The results are shown in Figs. 7(e) and 7(f) and lead to correct indexing of the type of interfacial plane.
Ultra-small nanoparticles or clusters, having sizes below 1 nm, form a challenging subject of investigation. In particular, the characterization of their structure is far from straightforward. At the same time, however, there is a clear need for a complete characterization in three-dimensions since these materials can no longer be considered as periodic objects. One of the main bottlenecks is that these clusters may rotate or show structural changes during investigation by TEM (Li et al., 2007). Obviously, conventional electron tomography methods, even those that are based on a limited number of projections, can no longer be applied. On the other hand, the intrinsic from the electron beam to the cluster can be considered as a unique possibility to investigate the transformation between energetically excited configurations of the same cluster. This idea was exploited to study the dynamic behaviour of ultra-small Ge clusters consisting of less than 25 atoms (Bals et al., 2012). Two-dimensional image series were collected using aberration-corrected HAADF STEM and selected frames were analysed using statistical parameter estimation theory. In this manner, the number of atoms at each position could be determined, as illustrated in Fig. 8. In order to extract three-dimensional structural information from these images without using prior knowledge of the structure, ab initio calculations were carried out. Several starting configurations were constructed that are all in agreement with the experimental two-dimensional projection images. Although all of the cluster configurations stay relatively close to their starting structure after full relaxation, only those configurations in which a planar base structure was assumed were found to be still compatible with the two-dimensional experimental images. In this manner, reliable three-dimensional structural models are obtained for these small clusters and the transformation of a predominantly two-dimensional configuration into a compact three-dimensional configuration can also be characterized.
7. Conclusions and outlook
The use of statistical parameter estimation techniques in the field of
is becoming increasingly important since it allows one to determine unknown structures quantitatively on a local scale. The theory of parameter estimation is well established and applications are becoming routine, partly through improvements in the underlying algorithms to estimate unknown structure parameters, and partly through the increase in computational power that allows fast processing and analysis. Applications in the field of high-resolution (S)TEM show how statistical parameter estimation techniques can be used to overcome the traditional limits set by modern The precision that can be achieved in this quantitative manner far exceeds the resolution performance of the instrument. The characterization limits are therefore no longer imposed by the quality of the lenses but are determined by the underlying physical principles. Structural, chemical, electronic and magnetic information can be obtained at the atomic scale. As demonstrated in this feature article, not only can quantitative be carried out in two-dimensions, but also three-dimensional analyses are currently becoming standard.The examples discussed in this feature article demonstrate that statistical parameter estimation methods have been applied successfully to nanostructures which are relatively stable under the incoming electron beam, and therefore the atomic structure under investigation can be assumed to remain unchanged under illumination with high electron doses. However, radiation damage becomes increasingly relevant not only in biological studies but also in the study of nanostructures (Meyer et al., 2014). An important challenge that remains is therefore to push the development of quantitative methods toward its fundamental limits. Ultimately, the goal is to measure the atom positions of beam-sensitive nanostructures with picometre precision and to discern between adjacent atom types. This is very challenging and to reach this goal the allowable electron dose needs to be used in the most optimal way. Indeed, every incoming electron counts and therefore needs to carry as much quantitative structural information as possible. For that purpose, the microscope and detector settings will be optimized using the principles of statistical experimental design (den Dekker et al., 1999, 2001, 2013; Van Aert, den Dekker, Van Dyck & van den Bos, 2002; Van Aert, den Dekker & Van Dyck, 2004; Van Aert, den Dekker et al., 2004). This becomes increasingly important in an era where new data collection geometries are emerging (Shibata et al., 2010; Yang et al., 2015). Therefore, the use of expressions representing the attainable precision, as discussed in this feature article, can be used to optimize the experimental design. Statistical experimental design can be defined as the selection of free variables in an experiment to improve the precision of the measured parameters. By calculating the attainable precision, the experimenter is able to verify whether, for a given experimental design, the precision is sufficient for the purpose at hand. If not, the experiment design has to be optimized so as to attain maximum precision. This will allow a significant reduction in the incoming electron dose to achieve maximum attainable precision or detectability. Finally, when lowering the incoming electron dose, it is expected that the use of a complete method to estimate unknown structure parameters will be of great help (den Dekker et al., 2005), in which the image-formation process is described using first-principles quantum mechanical models instead of simplified empirical models. Furthermore, an accurate description of the detector and noise properties, taking correlations between neighbouring pixel values into account, would then be required (Niermann et al., 2012; Lubk et al., 2012). The use of a complete estimation method will be computationally demanding, in which case graphical processing unit (GPU) computing strategies to reduce the total computing time will be very welcome (Dwyer, 2010; Lobato & Van Dyck, 2015). However, if successful, we will be able to measure unknown structure parameters as accurately and as precisely as possible using a given electron dose.
In conclusion, the possibilities of statistical parameter estimation theory in the field of
have been shown to be successful in the study of many materials problems so far. Recent developments to explore the capabilities of new detector geometries will certainly open up a whole new range of possibilities to understand and characterize beam-sensitive nanostructures in particular.Acknowledgements
The authors gratefully acknowledge the Research Foundation Flanders (FWO, Belgium) for funding and for a PhD grant to ADB. The research leading to these results has received funding from the European Union 7th Framework Program (FP7/20072013) under grant agreement No. 312483 (ESTEEM2). SB and GVT acknowledge the European Research Council under the 7th Framework Program (FP7), ERC grant No. 335078 - COLOURATOMS and ERC grant No. 246791 - COUNTATOMS. The authors thank the colleagues who have contributed to this work over the years, including K. J. Batenburg, R. Erni, B. Goris, B. Partoens, A. Rosenauer, M. D. Rossell, B. Schoeters, D. Schryvers, J. Sijbers, S. Turner and J. Verbeeck.
References
Ayache, J., Kisielowski, C., Kilaas, R., Passerieux, G. & Lartigue-Korinek, S. (2005). J. Mater. Sci. 40, 3091–3100. Web of Science CrossRef CAS Google Scholar
Bals, S., Casavola, M., van Huis, M. A., Van Aert, S., Batenburg, K. J., Van Tendeloo, G. & Vanmaekelbergh, D. (2011). Nano Lett. 11, 3420–3424. Web of Science CrossRef CAS PubMed Google Scholar
Bals, S., Van Aert, S., Romero, C. P., Lauwaet, K., Van Bael, M. J., Schoeters, B., Partoens, B., Yücelen, E., Lievens, P. & Van Tendeloo, G. (2012). Nat. Commun. 3, 897. Web of Science CrossRef PubMed Google Scholar
Bals, S., Van Aert, S., Van Tendeloo, G. & Ávila-Brande, D. (2006). Phys. Rev. Lett. 96, 096106. Web of Science CrossRef PubMed Google Scholar
Bettens, E., Van Dyck, D., den Dekker, A. J., Sijbers, J. & van den Bos, A. (1999). Ultramicroscopy, 77, 37–48. Web of Science CrossRef CAS Google Scholar
Browning, N., Arslan, I., Moeck, P. & Topuria, T. (2001). Phys. Status Solidi. B, 227, 229–245. Web of Science CrossRef CAS Google Scholar
Coene, W., Janssen, G., Op de Beeck, M. & Van Dyck, D. (1992). Phys. Rev. Lett. 69, 3743–3746. CrossRef PubMed CAS Web of Science Google Scholar
Cortie, M. B. & McDonagh, A. M. (2011). Chem. Rev. 111, 3713–3735. Web of Science CrossRef CAS PubMed Google Scholar
Cowley, J. M., Hansen, M. S. & Wang, S.-Y. (1995). Ultramicroscopy, 58, 18–24. CrossRef CAS Web of Science Google Scholar
Cramér, H. (1946). Mathematical Methods of Statistics. Princeton, New Jersey: Princeton University Press. Google Scholar
Crewe, A. V. (1968). J. Appl. Phys. 39, 5861–5868. CrossRef Web of Science Google Scholar
Crewe, A. V., Wall, J. & Langmore, J. (1970). Science, 168, 1338–1340. CrossRef PubMed CAS Web of Science Google Scholar
De Backer, A., De wael, A., Gonnissen, J. & Van Aert, S. (2015). Ultramicroscopy, 151, 46–55. Web of Science CrossRef CAS PubMed Google Scholar
De Backer, A., Martinez, G. T., MacArthur, K. E., Jones, L., Béché, A., Nellist, P. D. & Van Aert, S. (2015). Ultramicroscopy, 151, 56–61. Web of Science CrossRef CAS PubMed Google Scholar
De Backer, A., Martinez, G. T., Rosenauer, A. & Van Aert, S. (2013). Ultramicroscopy, 134, 23–33. Web of Science CrossRef CAS PubMed Google Scholar
De Backer, A., Van Aert, S. & Van Dyck, D. (2011). Ultramicroscopy, 111, 1475–1482. Web of Science CrossRef CAS PubMed Google Scholar
den Dekker, A. J., Gonnissen, J., De Backer, A., Sijbers, J. & Van Aert, S. (2013). Ultramicroscopy, 134, 34–43. Web of Science CrossRef CAS PubMed Google Scholar
den Dekker, A. J., Sijbers, J. & Van Dyck, D. (1999). J. Microsc. 194, 95–104. Web of Science CrossRef PubMed CAS Google Scholar
den Dekker, A. J., Van Aert, S., van den Bos, A. & Van Dyck, D. (2005). Ultramicroscopy, 104, 83–106. Web of Science CrossRef PubMed CAS Google Scholar
den Dekker, A. J., Van Aert, S., Van Dyck, D., van den Bos, A. & Geuens, P. (2001). Ultramicroscopy, 89, 275–290. Web of Science CrossRef PubMed CAS Google Scholar
Donoho, D. L. (2006a). IEEE Trans. Inf. Theory, 52, 1289–1306. Web of Science CrossRef Google Scholar
Donoho, D. L. (2006b). Commun. Pure Appl. Math. 59, 797–829. Web of Science CrossRef Google Scholar
Dwyer, C. (2010). Ultramicroscopy, 110, 195–198. Web of Science CrossRef CAS PubMed Google Scholar
Erni, R., Rossell, M. D., Kisielowski, C. & Dahmen, U. (2009). Phys. Rev. Lett. 102, 096101. Web of Science CrossRef PubMed Google Scholar
Goncalves-Ferreira, L., Redfern, S. A. T., Artacho, E. & Salje, E. K. H. (2008). Phys. Rev. Lett. 101, 097602. Web of Science PubMed Google Scholar
Gonnissen, J., De Backer, A., den Dekker, A. J., Martinez, G. T., Rosenauer, A., Sijbers, J. & Van Aert, S. (2014). Appl. Phys. Lett. 105, 063116. Web of Science CrossRef Google Scholar
Goris, B., Bals, S., Van den Broek, W., Carbó-Argibay, E., Gómez-Graña, S., Liz-Marzán, L. M. & Van Tendeloo, G. (2012). Nat. Mater. 11, 930–935. Web of Science CrossRef CAS PubMed Google Scholar
Goris, B., De Backer, A., Van Aert, S., Gómez-Graña, S., Liz-Marzán, L. M., Van Tendeloo, G. & Bals, S. (2013). Nano Lett. 13, 4236–4241. Web of Science CrossRef CAS PubMed Google Scholar
Goris, B., Van den Broek, W., Batenburg, K. J., Heidari Mezerji, H. & Bals, S. (2012). Ultramicroscopy, 113, 120–130. Web of Science CrossRef CAS Google Scholar
Grieb, T., Müller, K., Fritz, R., Schowalter, M., Neugebohrn, N., Knaub, N., Volz, K. & Rosenauer, A. (2012). Ultramicroscopy, 117, 15–23. Web of Science CrossRef CAS PubMed Google Scholar
Haider, M., Uhlemann, S., Schwan, E., Rose, H., Kabius, B. & Urban, K. (1998). Nature, 392, 768–769. Web of Science CrossRef CAS Google Scholar
Haigh, S., Sawada, H. & Kirkland, A. I. (2009). Philos. Trans. R. Soc. A, 367, 3755–3771. Web of Science CrossRef CAS Google Scholar
Henderson, R. (1995). Q. Rev. Biophys. 28, 171–193. CrossRef CAS PubMed Web of Science Google Scholar
Henglein, A. (2000). J. Phys. Chem. B, 104, 2201–2203. Web of Science CrossRef CAS Google Scholar
Herrmann, K.-H. (1997). Image Recording in Microscopy. Handbook of Microscopy – Applications in Materials Science, Solid-State Physics and Chemistry, Methods II, pp. 885–921. Weinheim: VCH. Google Scholar
Hodak, J. H., Henglein, A. & Hartland, G. V. (2000). J. Phys. Chem. B, 104, 5053–5055. Web of Science CrossRef CAS Google Scholar
Hovden, R. & Muller, D. A. (2012). Ultramicroscopy, 123, 59–65. Web of Science CrossRef CAS PubMed Google Scholar
Isaacson, M., Kopf, D., Ohtsuki, M. & Utlaut, M. (1979). Ultramicroscopy, 4, 101–104. CrossRef CAS Web of Science Google Scholar
Jia, C. L., Houben, L., Thust, A. & Barthel, J. (2010). Ultramicroscopy, 110, 500–505. Web of Science CrossRef CAS Google Scholar
Jia, C. L., Lentzen, M. & Urban, K. (2003). Science, 299, 870–873. Web of Science CrossRef PubMed CAS Google Scholar
Jia, C. L., Mi, S. B., Faley, M., Poppe, U., Schubert, J. & Urban, K. (2009). Phys. Rev. B, 79, 081405. Web of Science CrossRef Google Scholar
Jia, C. L., Mi, S. B., Urban, K., Vrejoiu, I., Alexe, M. & Hesse, D. (2008). Nat. Mater. 7, 57–61. Web of Science CrossRef PubMed CAS Google Scholar
Jia, C. L., Mi, S. B., Urban, K., Vrejoiu, I., Alexe, M. & Hesse, D. (2009). Phys. Rev. Lett. 102, 117601. Web of Science CrossRef PubMed Google Scholar
Jia, C. L. & Thust, A. (1999). Phys. Rev. Lett. 82, 5052–5055. Web of Science CrossRef CAS Google Scholar
Jinschek, J. R., Batenburg, K. J., Calderon, H. A., Kilaas, R., Radmilovic, V. & Kisielowski, C. (2008). Ultramicroscopy, 108, 589–604. Web of Science CrossRef PubMed CAS Google Scholar
Kay, S. M. (2009). Fundamentals of Statistical Signal Processing, Vol. II, Detection Theory. New Jersey: Prentice–Hall, Inc. Google Scholar
Kirkland, A. I., Saxton, W. O., Chau, K. L., Tsuno, K. & Kawasaki, M. (1995). Ultramicroscopy, 57, 355–374. CrossRef CAS Web of Science Google Scholar
Kisielowski, C., Hetherington, C. J. D., Wang, Y. C., Kilaas, R., O'Keefe, M. A. & Thust, A. (2001). Ultramicroscopy, 89, 243–263. Web of Science CrossRef PubMed CAS Google Scholar
Kisielowski, C., Principe, E., Freitag, B. & Hubert, D. (2001). Phys. B Condens. Matter, 308–310, 1090–1096. Web of Science CrossRef CAS Google Scholar
Koster, A. J., van den Bos, A. & van der Mast, K. D. (1987). Ultramicroscopy, 21, 209–222. CrossRef Web of Science Google Scholar
Kundu, P., Turner, S., Van Aert, S., Ravishankar, N. & Van Tendeloo, G. (2014). ACS Nano, 8, 599–606. Web of Science CrossRef CAS PubMed Google Scholar
Leary, R., Saghi, Z., Midgley, P. A. & Holland, D. J. (2013). Ultramicroscopy, 131, 70–91. Web of Science CrossRef CAS PubMed Google Scholar
LeBeau, J. M., Findlay, S. D., Allen, L. J. & Stemmer, S. (2008). Phys. Rev. Lett. 100, 206101. Web of Science CrossRef PubMed Google Scholar
LeBeau, J. M., Findlay, S. D., Allen, L. J. & Stemmer, S. (2010). Nano Lett. 10, 4405–4408. Web of Science CrossRef CAS PubMed Google Scholar
Li, Z. Y., Young, N. P., Di Vece, M., Palomba, S., Palmer, R. E., Bleloch, A. L., Curley, B. C., Johnston, R. L., Jiang, J. & Yuan, J. (2007). Nature, 451, 46–48. Web of Science CrossRef Google Scholar
Lichte, H. (1986). Ultramicroscopy, 20, 293–304. CrossRef CAS Web of Science Google Scholar
Lobato, I. & Van Dyck, D. (2015). Ultramicroscopy, 156, 9–17. Web of Science CrossRef CAS PubMed Google Scholar
Locquet, J. P., Perret, J., Fompeyrine, J., Mächler, E., Seo, J. W. & Van Tendeloo, G. (1998). Nature, 394, 453–456. Web of Science CrossRef CAS Google Scholar
Lord Rayleigh (1902). Scientific Papers by John William Strutt, Baron Rayleigh, Vol. 3, pp. 47–189. Cambridge University Press. Google Scholar
Lubk, A., Röder, F., Niermann, T., Gatel, C., Joulie, S., Houdellier, F., Magén, C. & Hÿtch, M. J. (2012). Ultramicroscopy, 115, 78–87. Web of Science CrossRef CAS PubMed Google Scholar
MacArthur, K. E., D'Alfonso, A. J., Ozkaya, D., Allen, L. J. & Nellist, P. D. (2015). Ultramicroscopy, 156, 1–8. Web of Science CrossRef CAS PubMed Google Scholar
MacArthur, K. E., Pennycook, T. J., Okunishi, E., D'Alfonso, A. J., Lugg, N. R., Allen, L. J. & Nellist, P. D. (2013). Ultramicroscopy, 133, 109–119. Web of Science PubMed Google Scholar
Martinez, G. T., De Backer, A., Rosenauer, A., Verbeeck, J. & Van Aert, S. (2014). Micron, 63, 57–63. Web of Science CrossRef CAS PubMed Google Scholar
Martinez, G. T., Rosenauer, A., De Backer, A., Verbeeck, J. & Van Aert, S. (2014). Ultramicroscopy, 137, 12–19. Web of Science CrossRef CAS PubMed Google Scholar
McLachlan, G. & Peel, D. (2000). Finite Mixture Models. Wiley Series in Probability and Statistics. New York: John Wiley and Sons Inc. Google Scholar
Meyer, J. C., Kotakoski, J. & Mangler, C. (2014). Ultramicroscopy, 145, 13–21. Web of Science CrossRef CAS PubMed Google Scholar
Möbus, G., Schweinfest, R., Gemming, T., Wagner, T. & Rühle, M. (1998). J. Microsc. 190, 109–130. Google Scholar
Muller, D. A. (1999). Ultramicroscopy, 78, 163–174. Web of Science CrossRef CAS Google Scholar
Muller, D. A. & Mills, M. J. (1999). Mater. Sci. Eng. A, 260, 12–28. Web of Science CrossRef Google Scholar
Nellist, P. D. & Pennycook, S. J. (2000). The Principles and Interpretation of Annular Dark-Field Z-Contrast Imaging. Advances in Imaging and Electron Physics, Vol. 113, edited by P. W. Hawkes, pp. 147–203. San Diego: Academic Press. Google Scholar
Niermann, T., Lubk, A. & Röder, F. (2012). Ultramicroscopy, 115, 68–77. Web of Science CrossRef CAS PubMed Google Scholar
O'Keefe, M. A. (1992). Ultramicroscopy, 47, 282–297. Google Scholar
Olson, G. B. (1997). Science, 277, 1237–1242. CrossRef CAS Web of Science Google Scholar
Olson, G. B. (2000). Science, 288, 993–998. Web of Science CrossRef CAS Google Scholar
Papoulis, A. (1965). Editor. Probability, Random Variables, and Stochastic Processes. New York: McGraw–Hill. Google Scholar
Reed, M. A. & Tour, J. M. (2000). Sci. Am. 282, 68–75. CrossRef Google Scholar
Retsky, M. (1974). Optik, 41, 127. Google Scholar
Rosenauer, A., Gries, K., Müller, K., Pretorius, A., Schowalter, M., Avramescu, A., Engl, K. & Lutgen, S. (2009). Ultramicroscopy, 109, 1171–1182. Web of Science CrossRef PubMed CAS Google Scholar
Rosenauer, A., Mehrtens, T., Müller, K., Gries, K., Schowalter, M., Venkata Satyam, P., Bley, S., Tessarek, C., Hommel, D., Sebald, K., Seyfried, M., Gutowski, J., Avramescu, A., Engl, K. & Lutgen, S. (2011). Ultramicroscopy, 111, 1316–1327. Web of Science CrossRef CAS PubMed Google Scholar
Rosenauer, A. & Schowalter, M. (2008). Microscopy of Semiconducting Materials. Springer Proceedings in Physics, Vol. 120, edited by A. G. Cullis and P. A. Midgley, pp. 170–172. Dordrecht: Springer Netherlands. Google Scholar
Saghi, Z., Holland, D. J., Leary, R., Falqui, A., Bertoni, G., Sederman, A. J., Gladden, L. F. & Midgley, P. A. (2011). Nano Lett. 11, 4666–4673. Web of Science CrossRef CAS PubMed Google Scholar
Saghi, Z., Xu, X. & Möbus, G. (2009). J. Appl. Phys. 106, 024304. Web of Science CrossRef Google Scholar
Seber, G. A. F. & Wild, C. J. (1989). Nonlinear Regression. New York: John Wiley and Sons. Google Scholar
Shibata, N., Kohno, Y., Findlay, S. D., Sawada, H., Kondo, Y. & Ikuhara, Y. (2010). J. Electron Microsc. 59, 473–479. Web of Science CrossRef CAS Google Scholar
Singhal, A., Yang, J. C. & Gibson, J. M. (1997). Ultramicroscopy, 67, 191–206. CrossRef CAS Web of Science Google Scholar
Spence, J. C. H. (1999). Mater. Sci. Eng. R, 26, 1–49. Web of Science CrossRef Google Scholar
Springborg, M. (2000). Methods of Electronic Structure Calculations: From Molecules to Solids. Chichester: John Wiley and Sons. Google Scholar
Tedsree, K., Li, T., Jones, S., Chan, C. W. A., Yu, K. M. K., Bagot, P. A. J., Marquis, E. A., Smith, G. D. W. & Tsang, S. C. E. (2011). Nature Nanotechnol. 6, 302–307. Web of Science CrossRef CAS Google Scholar
Thomas, J. M., Leary, R., Midgley, P. A. & Holland, D. J. (2013). J. Colloid Interface Sci. 392, 7–14. Web of Science CrossRef CAS PubMed Google Scholar
Urban, K. (2008). Science, 321, 506–510. Web of Science CrossRef PubMed CAS Google Scholar
Van Aert, S., Batenburg, K. J., Rossell, M. D., Erni, R. & Van Tendeloo, G. (2011). Nature, 470, 374–377. Web of Science CrossRef CAS PubMed Google Scholar
Van Aert, S., De Backer, A., Martinez, G. T., Goris, B., Bals, S., Van Tendeloo, G. & Rosenauer, A. (2013). Phys. Rev. B, 87, 064107. Web of Science CrossRef Google Scholar
Van Aert, S., den Dekker, A. J., van den Bos, A. & Van Dyck, D. (2002). IEEE Trans. Instrum. Meas. 51, 611–615. Web of Science CrossRef Google Scholar
Van Aert, S., den Dekker, A. J., van den Bos, A. & Van Dyck, D. (2004). Statistical Experimental Design for Quantitative Atomic Resolution Transmission Electron Microscopy. Advances in Imaging and Electron Physics, Vol. 130, pp. 1–164. San Diego: Academic Press. Google Scholar
Van Aert, S., den Dekker, A. J., van den Bos, A., Van Dyck, D. & Chen, J. H. (2005). Ultramicroscopy, 104, 107–125. Web of Science CrossRef PubMed CAS Google Scholar
Van Aert, S., den Dekker, A. J. & Van Dyck, D. (2004). Micron, 35, 425–429. Web of Science CrossRef PubMed CAS Google Scholar
Van Aert, S., den Dekker, A. J., Van Dyck, D. & van den Bos, A. (2002a). Ultramicroscopy, 90, 273–289. Web of Science CrossRef PubMed CAS Google Scholar
Van Aert, S., den Dekker, A. J., Van Dyck, D. & van den Bos, A. (2002b). J. Struct. Biol. 138, 21–33. Web of Science CrossRef PubMed CAS Google Scholar
Van Aert, S., Turner, S., Delville, R., Schryvers, D., Van Tendeloo, G. & Salje, E. K. H. (2012). Adv. Mater. 24, 523–527. Web of Science CrossRef CAS PubMed Google Scholar
Van Aert, S., Van Dyck, D. & den Dekker, A. J. (2006). Opt. Express, 14, 3830–3839. Web of Science CrossRef PubMed Google Scholar
Van Aert, S., Verbeeck, J., Erni, R., Bals, S., Luysberg, M., Van Dyck, D. & Van Tendeloo, G. (2009). Ultramicroscopy, 109, 1236–1244. Web of Science CrossRef PubMed CAS Google Scholar
van den Bos, A. (1982). Handbook of Measurement Science, edited by P. H. Sydenham, Vol. 1, pp. 331–377. Chichester: Wiley. Google Scholar
van den Bos, A. (2007). Parameter Estimation for Scientists and Engineers. Hoboken, New Jersey: John Wiley and Sons Inc. Google Scholar
van den Bos, A. & den Dekker, A. J. (2001). Resolution Reconsidered – Conventional Approaches and an Alternative. Advances in Imaging and Electron Physics, Vol. 117, edited by P. W. Hawkes, pp. 241–360. San Diego: Academic Press. Google Scholar
Van Dyck, D. & Coene, W. (1987). Optik, 77, 125–128. CAS Google Scholar
Van Dyck, D., Op de Beeck, M. & Coene, W. (1993). Optik, 93, 103–107. Google Scholar
Van Dyck, D., Van Aert, S., den Dekker, A. J. & van den Bos, A. (2003). Ultramicroscopy, 98, 27–42. Web of Science CrossRef PubMed CAS Google Scholar
Wada, Y. (1996). Microelectron. Eng. 30, 375–382. CrossRef CAS Web of Science Google Scholar
Yang, H., Pennycook, T. J. & Nellist, P. D. (2015). Ultramicroscopy, 151, 232–239. Web of Science CrossRef CAS PubMed Google Scholar
Zanchet, D., Hall, B. D. & Ugarte, D. (2001). X-ray Characterization of Nanoparticles. Characterization of Nanophase Materials, pp. 13–36. Weinheim: Wiley-VCH. Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.