bioXAS and metallogenomics
A novel BioXAS technique with sub-millisecond time resolution to track
and structural changes at biological metal centersaFreie Universität Berlin, FB Physik, Arnimallee 14, D-14195 Berlin, Germany, and bESRF, BP 220, 38043 Grenoble CEDEX, France
*Correspondence e-mail: haumann@physik.fu-berlin.de, holger.dau@physik.fu-berlin.de
Oxidation-state and structural changes at the metal center are crucial for the catalytic reactions of most metalloenzymes. The characterization of reaction intermediates is a prerequisite for understanding the catalytic mechanism. Frequently, intermediates are formed on the microsecond to millisecond timescale. To follow these reactions in real time represents a major challenge in structural biology. Time-resolved BioXAS is a particularly promising tool for resolving such intermediates. A novel approach for BioXAS, termed `sampling-XAS', is presented. First room-temperature sampling-XAS results have been obtained for the manganese complex of oxygenic photosynthesis. Oxidation-state changes are monitored with a time resolution as good as 200 µs. The current prospects and limitations as well as future perspectives of time-resolved BioXAS are discussed.
Keywords: time-resolved BioXAS; EXAFS; XANES; metalloenzymes; photosystem II.
1. Abbreviations
extended X-ray absorption fine structure.
FT: Fourier transform.
PSII: Photosystem II.
Si: oxidation states of the Mn complex.
TyrZ: redox-active tyrosine residue (D1-Tyr-161) of PSII.
XANES: X-ray absorption near-edge structure.
XAS: X-ray absorption spectroscopy.
2. Introduction
Metalloenzymes play a prominent role in the metabolic pathways of all organisms because an estimated 25–50% of all proteins carry metal atoms at the active sites crucially involved in the catalytic reactions (Hill et al., 1999). Frequently, the catalytic reactions of metalloenzymes can be formulated as a sequence or cycle during which several intermediate states are formed which differ with respect to and structure of the metal center. A static picture of the metal center as, for example, determined by crystallography, is often insufficient to understand the mechanism of the catalytic reaction. Essential information on the is rather expected to result from the detection and characterization of intermediates (Dau & Haumann, 2003). Typically, transitions between such intermediates occur on the microsecond to millisecond time scale. This holds, for example, in the biologically highly important chains of photosynthesis and respiration where essentially all involved proteins are metalloenzymes.
Synchrotron radiation techniques have been developed to characterize the structure of reaction intermediates of metalloenzymes at the atomic level as briefly discussed in the following.
(i) Crystallographic methods allow for the determination of complete enzyme structures from X-ray diffraction patterns of protein crystals; information on the electronic structure (oxidation state) of the protein-bound metal center is hardly obtainable. Standard protein crystallography usually provides a static picture of the atomic structure of (metallo)enzymes, now mostly obtained at cryogenic temperatures (around 100 K). The structures of reaction intermediates are accessible, for example, by freeze-quench approaches involving initiation of the reaction sequence, trapping of intermediates, and ; Scott, 2002). A method which provides much higher temporal resolution is time-resolved crystallography (Moffat, 2003). This method relies on the observation of structural changes in crystals positioned in the X-ray beam by recording time-series of diffraction patterns using short X-ray pulses before and after the onset of a reaction. By employing sudden trigger events (e.g. laser-flash excitation) for initiation of the reaction and by variation of the delay time between trigger and X-ray pulse, the determination of individual structures which are separated by time intervals of only picoseconds becomes feasible. This experiment requires high-quality crystals and reactions which can not only be rapidly initiated (by laser-pulse excitation) but also repetitively initiated to limit the amount of required crystals. The requirement of rapid and complete relaxation limits the application range of this approach. Impressive results using time-resolved crystallography have been obtained from studies of photochemically inducible reactions occurring in the sub-nanosecond time domain (Ren et al., 2001; Schotte et al., 2003; Adachi et al., 2003).
by X-ray diffraction. Using state-of-the-art techniques, the study of intermediates which are separated by tens of milliseconds in time may become viable (Stoddard, 2001(ii) By using ; Yachandra, 1995; Scott, 2000; Dau et al., 2003; for a recent review, see the special issue on BioXAS [J. Synchrotron Rad. (2003). 10, 1–112]}. It represents a specific advantage of that experiments can be performed on proteins in solution. Structural and electronic changes during a catalytic reaction cycle have been addressed by the three alternative BioXAS methods (Ascone et al., 2003; Dau & Haumann, 2003) discussed below.
information on both the atomic structure and the of the metal center becomes available {Teo, 1986(a) Stopped-flow/freeze-quench approaches can be used to populate reaction intermediates of metalloenzymes at ambient temperatures; spectra are subsequently collected at cryogenic temperatures. Using this technique, XANES and spectra during a single substrate turnover of the zinc site of bacterial alcohol dehydrogenase, separated by only ∼3 ms in time, have been obtained (Kleifeld et al., 2003). We (Iuzzolino et al., 1998; Dau et al., 2001; Dau & Haumann, 2003; Dau et al., 2003) and others (Ono et al., 1992; Robblee et al., 2001) have extensively used a related technique: the flash-freeze approach (population of intermediates by flash excitation of samples at ambient temperatures followed by rapid freezing and data collection at cryogenic temperatures) to investigate the structural and changes of the manganese complex of photosynthesis during its catalytic cycle (see below).
(b) In dispersive-XAS, a `white' X-ray beam is resolved into a continuum of beams of different `colours' (or energies) by a dispersive crystal and refocused on the sample. Thereby, the incidence angle on the sample becomes energy-dependent so that, behind the sample, the individual energies of the transmitted X-rays can be monitored simultaneously by a (Pascarelli et al., 1999). In principle, this technique can provide high time resolution. Dispersive-XAS, however, requires large metal concentrations (>10 mM) in the sample which are rarely obtainable with biological material. Accordingly, only few examples of dispersive-XAS on metalloenzymes have been reported (Joo et al., 1990; Della Longa et al., 1994).
(c) Rapid-scan techniques are a promising tool for studying state transitions at biological metal centers under physiological conditions where catalysis can proceed (e.g. protein in solution, room temperature). spectra are collected by means of rapid and continuous scans of the monochromato r; if required, the undulator gap is synchronously scanned (Solé et al., 1999). Using piezo-electric control of the monochromator (piezo-quick-EXAFS), XANES spectra have been obtained within ∼50 ms on relatively dilute samples (<10 mM metal concentration) and in fluorescence mode (Lützenkirchen-Hecht et al., 2001; Richwin et al., 2001). Using the rapid-scan mode (synchronous scan of monochromator and undulator gap) of beamline ID26 at the ESRF (Grenoble) we have obtained room-temperature spectra of the manganese complex of photosynthesis within minimally 3 s of scan time (for a ∼600 eV scan) after the laser-flash excitation which induces a state transition (Haumann et al., 2001; Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002; Dau & Haumann, 2003; see below).
By the X-ray techniques discussed above, it has not been possible to follow changes in the electronic and atomic structure of biological metal centers of dilute non-crystalline protein samples (metal concentration ≲1 mM) in the microsecond time domain, a time range that comprises most of the electron and proton transfer reactions that are the basis for the function of many metalloenzymes.
Today, to counteract radiation damage, structural synchrotron studies often involve deeply frozen enzymes. Whether the cryo-structures deviate from the ones at physiological temperatures is often uncertain (see Shimizu et al., 2000). Temperature-dependent measurements revealed changes in the structural dynamics of metal sites above the so-called `glass-transition point' (∼200 K) of proteins (Scherk et al., 2001; Dau et al., 2004). Real-time BioXAS techniques should avoid such ambiguities and facilitate monitoring of the state transitions under physiological conditions (meaning at ambient temperatures and on proteins in an aqueous environment).
The tetra-manganese complex of PSII catalyses the light-driven production of dioxygen from two water molecules. This reaction is of outstanding biological importance because it provides most of the oxygen in the atmosphere [for a recent review see the special issue on photosynthetic water oxidation, Biochim. Biophys. Acta, (2001), 1503]. Despite the availability of a wealth of structural information from recent crystallographic data (Zouni et al., 2001; Kamiya & Shen, 2003; Ferreira et al., 2004) and from previous investigations (for review see Dau et al., 2001; Robblee et al., 2001; Dau et al., 2003), the mechanism of water oxidation is still insufficiently understood (Rutherford & Faller, 2001). The reaction cycle of water oxidation is specifically well suited for the development of time-resolved techniques as it comprises four intermediate states (S0, S1, S2, S3) of the Mn complex which can be populated by flash excitation of PSII samples and which are stable at room temperature on the seconds to minutes time scale. Starting from the dark-stable S1 state, two flashes of light, each causing the abstraction of an electron from the Mn complex thereby inducing a transition Si → Si+1, drive the system to the S3 state. Upon the third flash, transition S3 → S0 is initiated. This reaction involves the transient formation of a (hypothetical) intermediate state, S4, which spontaneously converts to S0 under release of dioxygen (Haumann & Junge, 1999). It has been shown by various spectroscopic techniques that the time course of electron abstraction depends on the number of oxidizing equivalents already stored on the Mn complex; half-rise times of about 30 µs, 100 µs, 300 µs and 1.2 ms have been reported for the transitions S0 → S1, S1 → S2, S2 → S3 and S3 → S0, respectively (Dekker et al., 1984; Renger & Hanssum, 1992; Haumann, Bögershausen et al., 1997; Haumann, Hundelt et al., 1997). The reaction cycle of water oxidation is schematically summarized in Fig. 1.
Previous μ-oxo-bridged Mn pairs in the S1 state (Yachandra et al., 1987; Dau et al., 2001; Pospisil et al., 2003; Dau et al., 2003). Investigations by our group (Iuzzolino et al., 1998; Dau et al., 2004; Haumann et al., 2004) revealed that Mn-centered oxidation is likely to occur on each oxidizing transition. [Different interpretations have been offered by others (Messinger et al., 2001); for a detailed discussion see Dau et al. (2003).] Furthermore, accompanying structural changes (e.g. changes in the bridging mode between the four Mn atoms on at least some of the S transitions) have been postulated on the basis of results (Liang et al., 2000; Dau et al., 2001; Robblee et al., 2002; Dau & Haumann, 2003; Magnuson et al., 2004).
investigations are suggestive that the Mn complex is organized in two pairs of di-In this work, a novel
technique for following changes in the electronic and atomic structure of biological metal centers is presented, allowing the study of state transitions in real time, at room temperature, and in water-containing samples. We have termed this approach `sampling-XAS'. The perspectives of time-resolved sampling-BioXAS are discussed.3. Materials and methods
Oxygen-evolving PSII-enriched membrane particles (∼1200–1400 µmol O2 mol−1 chlorophyll h−1, measured at 301 K) with the Mn complex in its S1 state were prepared with betaine as as described by Iuzzolino et al. (1998), Schiller et al. (1998) and Schiller & Dau (2000). The PSII samples were prepared by a novel drop-and-dry technique: the sample holders were strips of black polycarbonate (1 mm × 20 mm × 200 mm) with ten cavities (15 × 2 mm holes backed by Kapton tape of 20 µm thickness; 15 mm spacing between the cavities). The artificial PPBQ was added to a solution of PSII membrane particles (∼7–8 mg chlorophyll mL−1; 200 µM PPBQ). Then, the suspension was pipetted into the cavities of the sample holder. Loaded sample holders were partially dried in a desicator at ∼3 × 107 Pa air pressure for 2 h at 277 K over silica gel (in darkness). The PSII-filled sample holders were prepared at the synchrotron radiation source immediately before the start of the X-ray experiment. Each of the more-than-1000 samples used in the experiments contained about 200 µg of chlorophyll and Mn at a concentration of ∼1 mM.
X-ray absorption measurements at the Mn K edge were performed at the undulator beamline ID26 of the European Synchrotron Radiation Facility (ESRF) in Grenoble (France). A Si 220 crystal monochromator was used, detuned to 70% of maximal intensity. The was monitored by a photodiode (active area ∼4 cm2) shielded by thin Cr- and Al-foil filters against scattered X-rays and visible light. The PSII samples were surrounded by plain air (room temperature of 291 K; angle of 55° between sample normal and electric field vector of the X-ray beam). One scan per sample was performed on dark-adapted samples (X-ray spot size of 1 mm × 1 mm). For further details see Solé et al. (1999), Meinke et al. (2000), Haumann, Grabolle et al. (2002), Haumann, Pospisil et al. (2002) and Dau & Haumann (2003).
Rapid-scan et al., 2000; Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002). Energy calibration was facilitated by using the narrow pre-edge peak of a simultaneously measured KMnO4 as a standard (peak at 6543.3 eV). The Mn K-edge energy was determined using the `integral method' described by Dittmer et al. (1998) and Dau et al. (2003).
data evaluation was carried out as described elsewhere (MeinkeFlash excitation of the samples was performed at ID26 by a frequency-doubled Q-switched Nd-YAG laser (Quantel Brilliant, FWHM 5 ns, 532 nm, ∼150 mJ per flash). Guided by appropriate laser optics, the light flashes illuminated both sides of the samples simultaneously [see Fig. 7 of Dau & Haumann (2003)].
During the
experiments, the sample holders containing ten PSII samples were positioned with a precision of ∼4 µm in the X-ray beam by a home-built computer-controlled sample changer (linear stage with 15 cm driving range and stepping motor) which allows for sample exchange within ∼3 s. Only the sample exposed to the X-ray beam was accessible to the laser flashes; neighbouring samples were shielded against illumination.Two types of experiments were performed. (i) topen ≃ 10 ms) opened immediately before the start of data collection. All experiments were carried out at room temperature.
scans using the rapid-scan mode of ID26 (synchronous scan of undulator gap and monochromator) were performed within 3 s (scan range 6500–7100 eV). (ii) Time scans of fluorescence were carried out at a fixed X-ray energy and measuring the intensity as a function of time using either the beamline electronics for data acquisition (10 or 20 ms per data point) or a personal computer equipped with an A/D card (200 µs per data point, 10 kHz electrical bandwidth). A rapid beam shutter (4. Results and discussion
4.1. The sampling-XAS technique
The used method of sampling-XAS at room temperature involves the following experimental protocol (Fig. 2). (i) To yield a reference spectrum of the Mn complex in its S1 state, a rapid scan was performed within 3 s on a first spot of a PSII sample (not illuminated by laser flashes) (Fig. 2-i). (ii) Then, the sample was repositioned to expose a second spot to the X-ray beam. After repositioning, the time course of the intensity was monitored at a fixed for 60 s [time scan of fluorescence (Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002)] (Fig. 2-ii). During the first few seconds of the time scan, three nanosecond laser flashes illuminated the sample, causing the stepwise advancement of the Mn complex through the whole catalytic cycle (inset in Fig. 2-ii, arrows). (iii) Thereafter, on the same sample spot a rapid scan was performed (Fig. 2-iii). Then, a new sample was exposed to the beam and the whole sequence of measurements started again. Eventually, the used during the time scan was changed to a new value.
Each flash given to the PSII samples during the time scans caused a jump in the fluorescence intensity level (Fig. 2-ii, inset). These jumps are indicative of the stepping of the Mn complex through its catalytic cycle. They originate in the S-state dependence of the spectra of the Mn complex. Differences are most pronounced in the edge region (see Fig. 2-ii, inset) because of the different K-edge positions of the individual S states; in the region, the observable differences are smaller (not shown). The rise of the fluorescence intensity within 60 s (Fig. 2-ii) is attributable to the of the high-valent Mn4 complex to four Mn(II) ions resulting from the creation of numerous radicals in the sample by X-ray irradiation (Dau et al., 1997; Meinke et al., 2000; Haumann, Grabolle et al., 2002). The magnitude of this rise reflects the difference in the spectra taken before (S1 state, Fig. 2-i) and after the time scan [Mn(II) spectrum, Fig. 2-iii].
To construct
spectra at selected points in time from fluorescence time scans at a series of energies, the following procedure is used:(a) For the E, used in the time scan, the fluorescence offset, Foff(E), and the magnitude of the edge jump, Fnorm (independent of E), were determined from the scan measured on the same sample spot after the time scan (Fig. 2-iii).
(b) Using these parameters, the fluorescence time-scan trace (Fig. 2-ii) was normalized to yield the calibrated fluorescence Fcal(E, t) according to
(c) Plotting the values of Fcal at a certain point in time during the time scans against the respective excitation energies E should yield the spectrum.
The above-described method is precise enough to obtain sound sampling-XANES spectra (see below). In the i.e. a higher precision of the calibration is required. We find that Fnorm can be determined to a high precision whereas the determination of Foff by the above procedure introduces a significant error. Therefore, to obtain sampling-EXAFS spectra, we use the normalized S1-state reference spectrum (inset in Fig. 2-i) for calibration of time-scan data. For a perfectly precise value of Foff(E), the calibrated fluorescence levels, F0cal(E), attributable to the Mn complex in the S1 state [obtained from fluorescence levels F0(E) before flash excitation, see inset of Fig. 2-ii] and the fluorescence levels Fref(E) of the normalized S1-state reference spectrum (inset in Fig. 2-i) are identical; the S1-state sampling-XAS and rapid-scan spectra should be equal,
region, the fluorescence changes during the time scan are much smaller,To ensure validity of (2), we now replace the Foff(E) values in (1) by the following expression,
yielding (4) which is used to calculate the refined calibrated fluorescence values, Fcalr(E), at each energy point,
with
In the present study, the spectrum of the dark-stable S1 state is used as a reference spectrum. Equation (4) simply means that the changes induced by the laser-flash illumination are normalized and added to the reference spectrum. Plotting Fcalr against the respective excitation energies at each point in time should yield refined sampling-XAS spectra. In the following, complete sampling-XANES spectra derived according to (1) and sampling-EXAFS spectra calculated using (4) of the Mn complex of PSII are presented.
4.2. Time scans and sampling-XANES on the Mn complex of PSII to follow radiation damage
One problem of et al., 2000; Haumann, Grabolle et al., 2002; Grabolle et al., 2005). This problem is even more severe in the case of highly oxidized metal centers where rapid X-ray reduction of the metal may occur. An example of this effect is depicted in Fig. 3(a) where the rise in fluorescence to the constant level reached after about 60 s reflects the reduction of the majority of the highly oxidized Mn atoms (average of +3.5 in the S1 state) to the Mn(II) level. The rise shows a of ∼3 s duration. A similar lag has been previously observed with samples initially in the S1 state (Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002). Its length depends on the X-ray longer lag phases are obtained at lower X-ray intensities (Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002).
measurements on metalloenzymes at room temperature is that the rate of radiation damage is drastically increased compared with measurements at cryogenic temperatures (MeinkeFig. 3 shows sampling-XANES spectra (symbols) that were constructed from time scans measured on dark-adapted samples (Mn in the S1 state). The shown spectra correspond to X-ray irradiation intervals ranging from 0 to 60 s. These spectra have been obtained employing equation (1); no reference spectrum was involved. The sampling-XANES spectra closely resemble those that have been obtained by rapid-scan (lines in Fig. 2) before (Mn complex in its S1 state) and after [Mn(II) spectrum] the time scans (compare Figs. 2-i and 2-iii). The spectrum obtained after 3 s is still similar to that obtained immediately after the onset of X-ray irradiation (edge shift to lower energies of less than 0.1 eV). Thus, if the full length of the is used for rapid scans, the Mn complex remains essentially (>90%) in the S1 state. The sampling-XANES spectra obtained for longer X-ray irradiation clearly show changes in shape and edge energy owing to the formation of increasing amounts of Mn(II) in the samples upon the destruction of the two di-μ-oxo-bridged Mn pairs (Grabolle et al., 2005) by of Mn in the tens of seconds time range.
4.3. Sampling-XANES on the Mn complex in different S states
From time scans of the fluorescence intensity during a laser-flash illumination sequence (see Fig. 2), the stepping of the Mn complex through its catalytic cycle is monitored. When this technique is applied in the region of the Mn K edge, even small changes in the XANES spectra of the four intermediate states become directly visible. Such changes are less reliably observed by continuous-scan techniques (uncertainty in the normalization of the spectra by a few percent already may render the detection of small differences unreliable). This specific benefit of the time-scan technique is demonstrated by the data in Fig. 4. As a particularly interesting example we discuss the changes induced by flashes 1 and 2 populating the S2 and S3 states, respectively. At the various excitation energies very different relative changes of the fluorescence intensities are observed on flashes 1 and 2 (Fig. 4). As can be deduced from Fig. 4, the change in fluorescence is negative on flash 1 but positive on flash 2 in the region of the pre-edge peak (around 6545 eV, compare Fig. 5). Flashes 1 and 2 induce an approximately equal decrease in fluorescence at 6549.5 eV. At 6552.8 eV, the decrease is clearly larger on flash 1 than on flash 2. At 6559 eV, flash 1 induces a decrease whereas flash 2 results in an increase of fluorescence. Beyond the edge maximum (at 6571 eV) both flashes 1 and 2 induce an increase of the fluorescence intensity. A decrease of the fluorescence in the rising part of the edge is indicative of a shift of the edge position to higher energies. If only the edge energy increases but the edge shape remains unchanged, one expects a fluorescence decrease in the whole rising part of the edge upon a flash. Now, translating the fluorescence changes in Fig. 4 into changes of the XANES spectra, we note that the edge spectrum of the S3 state shifts to higher energies mostly in its part roughly below the half-height, whereas the S2-state edge is shifted to higher energies with respect to the S1 edge in its whole rising part. A crossover between the S3-state and S2-state spectra is observed at around 6556 eV. Above this energy, the S3 edge is higher. On the basis of simulations using modern full-multiple scattering code (Ankudinov et al., 1998), we have previously attributed the changes in the shape and energy position of the S3-state XANES to the formation of six-coordinated Mn(IV) from five-coordinated Mn(III) occurring upon the S2 → S3 transition (Dau et al., 2003). The time-scan data in Fig. 4 provide a first indication that similar changes in the XANES are observed in cryo- and room-temperature measurements [for low-temperature data see Iuzzolino et al. (1998), Messinger et al. (2001), Dau et al., 2003)].
Sampling-XANES spectra of the dark-stable S1 state and of the sample predominantly in the S2 state were constructed [according to (1)] from time scans using the average fluorescence intensities before and after the first flash given to PSII samples (F0 and F1 levels in the inset of Fig. 2-ii). The resulting spectra (Fig. 5, symbols) are significantly affected by noise contributions and represent a preliminary result. We note that these spectra correspond to data obtained within only 400 ms either before or after the laser flash. The thus obtained pre-flash sampling-XANES spectrum (solid circles) seems to be in agreement with the S1-state reference spectrum obtained by rapid-scan (Fig. 5, line). After the flash, the K edge is shifted to higher energies (most clearly seen in the inset of Fig. 5 which shows the difference of one-flash minus the zero-flash spectrum); an upshift in energy by ∼0.7 eV is estimated at half-height. This upshift reflects the oxidation of the Mn complex by one equivalent owing to electron abstraction in the S1 → S2 transition (Yachandra et al., 1987; Messinger et al., 2001; Iuzzolino et al., 1998; Haumann, Pospisil et al., 2002; Dau et al., 2003). The roughly derivative-like difference spectrum, which crosses the zero line at an energy of ∼6561 eV (inset in Fig. 5), suggests that the K-edge shape is similar in S1 and S2; the edge position, however, is shifted to higher energies in S2. These observations are compatible with the notion that no major structural changes are coupled to the single-electron oxidation of Mn on the S1 → S2 transition.
4.4. First sampling-EXAFS spectra to monitor structural changes in the Mn complex
From similar data as shown in Figs. 2 and 4, but extending over the region, first sampling-EXAFS spectra of the Mn complex in its S1 state (no flash illumination), after one laser flash (predominant population of the S2 state) and after two flashes (predominant S3 population) were constructed according to (4) using the continuous-scan S1-state spectrum (Fig. 2-i) as a reference. The resulting sampling-EXAFS oscillations are shown in the inset of Fig. 6. Two prominent peaks are obvious in the FTs of the oscillations (Fig. 6). Owing to noise level and limited k-range, only a tentative interpretation can be given. Peak I is attributed to a first sphere of mainly oxygen ligands to Mn whereas peak II mainly results from Mn → Mn interactions of ∼2.7 Å length, attributable to pairs of di-μ-oxo-bridged Mn atoms as discussed elsewhere (Penner-Hahn, 1999; Robblee et al., 2001; Dau et al., 2001). Peaks I and II behave differently when advancing in the S-state cycle. Peak I increases on the first and second flash. Peak II is about equal in the zero- and one-flash spectra but significantly increased in the two-flash spectrum. Qualitatively very similar changes in the Fourier-transformed spectra have been previously observed in spectra measured at 20 K (freeze-quench approach) (Dau et al., 1998, 2001; Haumann et al., 2001, 2004) and at room temperature (rapid-scan approach; laser-flash illumination of samples exposed to the X-ray beam) (Haumann et al., 2001, 2004; Haumann, Grabolle et al., 2002). The increase of the magnitude of FT peak II in the two-flash spectrum has been interpreted as indicating the formation of a new di-μ-oxo bridge between Mn ions in the S3 state (Dau et al., 2001; Haumann et al., 2004). Pure spectra of the S states can be obtained by deconvolution techniques. As shown elsewhere (Dau et al., 2001; Haumann et al., 2004), deconvolution leads to enhancement of the differences already visible in the raw spectra of Fig. 6.
4.5. First steps towards the tracking of state transitions with microsecond time resolution
In principle, the time resolution of the sampling-XAS technique can also be extended into the microsecond (or even nanosecond) range. Measuring time scans of fluorescence with microsecond resolution may allow monitoring of, in real time, the transitions of the metal center between the intermediate states of its catalytic cycle. Fig. 7 shows a time scan of fluorescence at 6553 eV (dots) with a resolution of 200 µs per point. The shown transition was initiated by the third laser flash which mainly induces the oxygen-evolving S3 → S0 step.
On the S3 → S0 transition, Mn is reduced by electrons from the bound water resulting in the formation of dioxygen. Consequently, the Mn K edge shifts to lower energies causing a fluorescence increase in the K-edge region upon flash 3 (see Fig. 2-ii, inset). The fluorescence transient on flash 3 (Fig. 6) clearly reveals several points in its rising part. A single-exponential fit of the data yields a rise time of t1/2 = 1.1 ms (line). Very similar rise-time values are typically observed by other techniques such as optical absorption spectroscopy and EPR which have been used to study the kinetics of Mn oxidation or TyrZox reduction (Rappaport et al., 1994; Haumann, Hundelt et al., 1997; Razeghifard & Pace, 1997). The rise time is found to be slower in preparations with less-intact PSII (Haumann, Hundelt et al., 1997; Razeghifard & Pace, 1997). The transient obtained upon flash 1 (Fig. 7, inset), where Mn oxidation occurs with t1/2 ≃ 100 µs, on the other hand, resembles a step function at the here-used resolution of 200 µs per point. For the first time, the S3 → S0 transition was followed in real time using That the rise time is close to 1 ms suggests that the Mn complex is in its most intact conformation (Haumann, Bögershausen et al., 1997; Haumann, Hundelt et al., 1997) in the here-used (partly dehydrated) samples.
Time scans of the fluorescence changes which are caused by the flash that induces the oxygen-evolving transition S3 → S0 (flash 3) were recorded with 200 µs per point at a series of excitation energies in the rising part of the Mn K edge. From these data, a time series of sampling-XANES spectra was constructed where the individual spectra are separated by only 500 µs in time (Fig. 8, symbols). The transient spectra obtained within 500 µs before flash 3 and at ∼3 ms after this flash are very similar to those obtained by averaging of data within 400 ms before and after flash 3 (from fluorescence levels F2 and F3, see Fig. 2-ii, inset), suggesting that the structural and changes closely follow the electron extraction by TyrZox. The mechanistically particularly important question as to whether intermediate states are formed within the first 500 µs remains open at the presently achieved time resolution of 200 µs. The transient XANES spectra reflect the changes in edge shape and energy owing to the reduction (by four electrons from water) and structural rearrangement at the Mn atoms [lengthening of Mn—ligand distances (see Dau et al., 2003), loss of one μ-oxo bridge and possibly protonation of another μ-oxo bridge] during the oxygen-evolving transition (Dau et al., 2001; Dau & Haumann, 2003).
5. Conclusions
By tracking the structural and electronic changes at biological metal centers in real time, valuable information can be gained. A novel fluorescence-mode BioXAS technique is presented, termed sampling-XAS, which allows for the monitoring of state transitions and for the resolution of intermediates with microsecond to second time resolution at room temperature using water-containing non-crystalline etc.) can be avoided.
samples. By monitoring the structural changes directly at (almost) physiological conditions, potential ambiguities (crystal packing effects, cryo-artifactsThe manganese complex of PSII, which catalyses the formation of the atmospheric dioxygen, was used as a specifically well suited model system to explore the prospects and current limitations of the sampling-XAS technique. Preliminary room-temperature XANES and et al., 1998; Meinke et al., 2000; Dau et al., 2001; Haumann, Grabolle et al., 2002; Haumann, Pospisil et al., 2002; Pospisil et al., 2003; Dau & Haumann, 2003; Dau et al., 2003; Magnuson et al., 2004). Specifically we conclude:
spectra were obtained which represent the structure of the Mn complex acquired within milliseconds after population of the respective S state by laser-flash illumination. Furthermore, the time course of the oxygen-evolving transition was followed in real time with 200 µs resolution. In the future, similar experiments may extend the results obtained from our previous investigations (Iuzzolino(i) Room-temperature
at a high-flux undulator beamline is feasible even if highly oxidized metal centers are used which are particularly susceptible to X-ray By the employment of well adapted measuring protocols, any significant radiation-damage influence can be avoided.(ii) The Mn complex is in its most intact conformation in our 3 → S0 transition determined by analysis of the time course of X-ray transients. The stepping of the Mn complex through the catalytic cycle can be achieved by laser-flash illumination at the beamline.
samples in the majority of centers as indicated by the short rise time of the S(iii) It has been demonstrated that the sampling-XAS approach can facilitate determination of XANES and
spectra for intermediates of the S-state cycle.(iv) The shown time-resolved 3 → S0 transition, where Mn becomes reduced, represent a first step towards characterization of putative intermediate states with lifetimes in the microsecond range. Such intermediates may be related to formation and decay of the S4 state during the process of oxygen evolution. By further improvement of these measurements and their extension into the region, the direct monitoring in real time of the changes in electronic structure and nuclear geometry at the Mn complex during all four S transitions may become feasible. These experiments are expected to provide new structural and electronic information of high importance for the understanding of the mechanism of photosynthetic oxygen-evolution.
data on the SAcknowledgements
Financial support by the German BMBF (grant 05KS1KEA/6) and by the Deutsche Forschungsgemeinschaft (SFB 498, projects C6 and C8) is gratefully acknowledged. We thank the staff members at ID26 and M. Fünning for excellent technical assistance.
References
Adachi, S., Park, S. Y., Tame, J. R., Shiro, Y. & Shibayama, N. (2003). Proc. Natl. Acad. Sci. USA, 100, 7039–7044. Web of Science CrossRef PubMed CAS Google Scholar
Ankudinov, A. L., Ravel, B., Rehr, J. J. & Conradson, S. D. (1998). Phys. Rev. B, 12, 7565–7576. Web of Science CrossRef Google Scholar
Ascone, I., Meyer-Klaucke, W. & Murphy, L. (2003). J. Synchrotron Rad. 10, 16–22. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dau, H., Dittmer, J., Iuzzolino, L., Schiller, H., Dörner, W., Heinze, L., Sole, V. A. & Nolting, H.-F. (1997). J. Phys. IV, 7, 607–610. CrossRef CAS Google Scholar
Dau, H. & Haumann, M. (2003). J. Synchrotron Rad. 10, 76–85. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dau, H., Iuzzolino, L. & Dittmer, J. (2001). Biochim. Biophys. Acta, 1503, 24–39. Web of Science CrossRef PubMed CAS Google Scholar
Dau, H., Iuzzolino, L., Dittmer, J., Dörner, W. & Meyer-Klaucke, W. (1998). Photosynthesis: Mechanism and Effects, Vol. II, edited by G. Garab, pp. 1327–1330. Dordrecht: Kluwer. Google Scholar
Dau, H., Liebisch, P. & Haumann, M. (2003). Anal. Bioanal. Chem. 376, 562–583. Web of Science CrossRef PubMed CAS Google Scholar
Dau, H., Liebisch, H. & Haumann, M. (2004). Phys. Chem. Chem. Phys. 6, 4781–4792. Web of Science CrossRef CAS Google Scholar
Dekker, J. P., Plijter, J. J., Ouwehand, L. & van Gorkom, H. J. (1984). Biochim. Biophys. Acta, 767, 176–179. CrossRef CAS Google Scholar
Della Longa, S. D., Ascone, I., Fontaine, A., Congiu Castellano, A. & Bianconi, A. (1994). Eur. Biophys. J. 23, 361–368. CrossRef CAS PubMed Google Scholar
Dittmer, J., Iuzzolino, L., Dörner, W., Nolting, H.-F., Meyer-Klaucke, W. & Dau, H. (1998). Photosynthesis: Mechanism and Effects, Vol. II, edited by G. Garab, pp. 1339–1342. Dordrecht: Kluwer. Google Scholar
Ferreira, K. N., Iverson, T. M., Maghlaoui, K., Barber, J. & Iwata, S. (2004). Science, 303, 1831–1838. Web of Science CrossRef PubMed CAS Google Scholar
Grabolle, M., Haumann, M., Liebisch, P., Müller, C., Neisius, T., Meyer-Klaucke, W. & Dau, H. (2005). In preparation. Google Scholar
Haumann, M., Bögershausen, O., Cherepanov, D. A., Ahlbrink, R. & Junge, W. (1997). Photosynth. Res. 51, 193–208. CrossRef CAS Web of Science Google Scholar
Haumann, M., Grabolle, M., Neisius, T. & Dau, H. (2002). FEBS Lett. 512, 116–120. Web of Science CrossRef PubMed CAS Google Scholar
Haumann, M., Grabolle, M., Werthammer, M., Iuzzolino, L., Dittmer, J., Meyer-Klaucke, W., Neisius, T. & Dau, H. (2001). PS2001 Proceedings, Contribution S10-013, pp. 1–5. Collingwood: CSIRO Publishing. Google Scholar
Haumann, M., Hundelt, M., Jahns, P., Chroni, S., Bögershausen, O., Ghanotakis, D. & Junge, W. (1997). FEBS Lett. 410, 243–248. CrossRef CAS PubMed Web of Science Google Scholar
Haumann, M. & Junge, W. (1999). Biochim. Biophys. Acta, 1411, 86–91. CrossRef PubMed CAS Google Scholar
Haumann, M., Müller, C., Liebisch, P., Iuzzolino, L., Dittmer, J., Grabolle, M., Neisius, T., Meyer-Klaucke, W. & Dau, H. (2004). Biochemistry. In the press. Google Scholar
Haumann, M., Pospisil, P., Grabolle, M., Müller, C., Liebisch, P., Solé, V. A., Neisius, T., Dittmer, J. & Dau, H. (2002). J. Synchrotron Rad. 9, 304–309. Web of Science CrossRef CAS IUCr Journals Google Scholar
Hill, H. A. O., Sadler, P. J. & Thomson, A. J. (1999). Metal Sites in Proteins and Models. Berlin: Springer. Google Scholar
Iuzzolino, L., Dittmer, J., Doerner, W., Meyer-Klaucke, W. & Dau, H. (1998). Biochemistry, 37, 17112–17119. Web of Science CrossRef CAS PubMed Google Scholar
Joo, M. S., Tourillon, G., Sayers, D. E. & Theil, E. C. (1990). Biol. Met. 3, 171–175. CrossRef CAS PubMed Google Scholar
Kamiya, N. & Shen, J. R. (2003). Proc. Natl. Acad. Sci. USA, 100, 98–103. Web of Science CrossRef PubMed CAS Google Scholar
Kleifeld, O., Frenkel, A., Martin, J. M. & Sagi, I. (2003). Nature Struct. Biol. 10, 75–77. Web of Science CrossRef PubMed Google Scholar
Liang, W., Roelofs, T., Cinco, R. M., Rompel, A., Latimer, M., Yu, W., Sauer, K., Klein, M. P. & Yachandra, V. K. (2000). J. Am. Chem. Soc. 122, 3399–3412. Web of Science CrossRef CAS PubMed Google Scholar
Lützenkirchen-Hecht, D., Grundmann, S. & Frahm, R. (2001). J. Synchrotron Rad. 8, 6–9. Web of Science CrossRef IUCr Journals Google Scholar
Magnuson, A., Liebisch, P., Haumann, M., Högblom, J. E. B., Anderlund, M. F., Lomoth, R., Meyer-Klaucke, W. & Dau, H. (2004). J. Bioinorg. Chem. Submitted for publication. Google Scholar
Meinke, C., Solé, V. A., Pospisil, P. & Dau, H. (2000). Biochemistry, 39, 7033–7040. Web of Science CrossRef PubMed CAS Google Scholar
Messinger, J., Robblee, J. H., Bergmann, U., Fernandez, C., Glatzel, P., Visser, H., Cinco, R. M., McFarlane, K. L., Bellacchio, E., Pizarro, S. A., Cramer, S. P., Sauer, K., Klein, M. P. & Yachandra, V. K. (2001). J. Am. Chem. Soc. 123, 7804–7820. Web of Science CrossRef PubMed CAS Google Scholar
Moffat, K. (2003). Faraday Discuss. 122, 65–77. Web of Science CrossRef PubMed CAS Google Scholar
Ono, T., Nogushi, T., Inoue, Y., Kusunoki, M., Matsushita, T. & Oyanagi, H. (1992). Science, 258, 1335–1337. CrossRef PubMed CAS Web of Science Google Scholar
Pascarelli, S., Neisius, T., De Panfilis, S., Bonfim, M., Pizzini, S., Mackay, K., David, S., Fontaine, A., San Miguel, A., Itie, J. P., Gauthier, M. & Polian, A. (1999). J. Synchrotron Rad. 6, 146–148. Web of Science CrossRef IUCr Journals Google Scholar
Penner-Hahn, J. E. (1999). Metal Sites in Proteins and Models: Redox Centres, edited by H. A. O. Hill, P. J. Sadler and A. J. Thomson, pp. 1–36. Berlin: Springer. Google Scholar
Pospisil, P., Haumann, M., Dittmer, J., Solé, A. V. & Dau, H. (2003). Biophys. J. 84, 1370–1386. Web of Science PubMed CAS Google Scholar
Rappaport, F., Blanchard-Desce, M. & Lavergne, J. (1994). Biochim. Biophys. Acta, 1184, 178–192. CrossRef CAS Google Scholar
Razeghifard, M. R. & Pace, R. J. (1997). Biochim. Biophys. Acta, 1322, 141–150. Google Scholar
Renger, G. & Hanssum, B. (1992). FEBS Lett. 299, 28–32. CrossRef PubMed CAS Web of Science Google Scholar
Ren, Z., Perman, B., Srajer, V., Teng, T. Y., Pradervand, C., Bourgeois, D., Schotte, F., Ursby, T., Kort, R., Wulff, M. & Moffat, K. (2001). Biochemistry, 40, 13788–13801. Web of Science CrossRef PubMed CAS Google Scholar
Richwin, M., Zaeper, R., Lützenkirchen-Hecht, D. & Frahm, R. (2001). J. Synchrotron Rad. 8, 354–356. Web of Science CrossRef CAS IUCr Journals Google Scholar
Robblee, J. H., Cinco, R. M. & Yachandra, V. K. (2001). Biochim. Biophys. Acta, 1503, 7–23. Web of Science CrossRef PubMed CAS Google Scholar
Robblee, J. H., Messinger, J., Cinco, R. M., McFarlane, K. L., Fernandez, C., Pizarro, S. A., Sauer, K. & Yachandra, V. K. (2002). J. Am. Chem. Soc. 124, 7459–7471. Web of Science CrossRef PubMed CAS Google Scholar
Rutherford, A. W. & Faller, P. (2001). Trends Biochem. Sci. 26, 341–344. Web of Science CrossRef PubMed CAS Google Scholar
Scherk, C. G., Ostermann, A., Achterhold, K., Iakovleva, O., Nazikkol, C., Krebs, B., Knapp, E. W., Meyer-Klaucke, W. & Parak, F. G. (2001). Eur. Biophys. J. 30, 393–403. CrossRef PubMed CAS Google Scholar
Schiller, H. & Dau, H. (2000). J. Photochem. Photobiol. B, 55, 138–144. Web of Science CrossRef PubMed CAS Google Scholar
Schiller, H., Dittmer, J., Iuzzolino, L., Doerner, W., Meyer-Klaucke, W., Sole, V. A., Nordstroem, T. & Dau, H. (1998). Biochemistry, 37, 7340–7350. Web of Science CrossRef CAS PubMed Google Scholar
Schotte, F., Lim, M., Jackson, T. A., Smirnov, A. V., Soman, J., Olson, J. S., Phillips, G. N. Jr, Wulff, M. & Anfinrud, P. A. (2003). Science, 300, 1944–1947. Web of Science CrossRef PubMed CAS Google Scholar
Scott, R. A. (2000). Physical Methods in Bioinorganic Chemistry – Spectroscopy and Magnetism, edited by L. Que Jr, pp. 465–504. Sausalito: University Science. Google Scholar
Scott, W. G. (2002). Methods, 28, 302–306. Web of Science CrossRef PubMed CAS Google Scholar
Shimizu, H., Park, S., Lee, D., Shoun, H. & Shiro, Y. (2000). J. Inorg. Biochem. 81, 191–205. Web of Science CrossRef PubMed CAS Google Scholar
Solé, V. A., Gauthier, C., Goulon, J. & Natali, F. (1999). J. Synchrotron Rad. 6, 174–175. Web of Science CrossRef IUCr Journals Google Scholar
Stoddard, B. L. (2001). Methods, 24, 125–138. Web of Science CrossRef PubMed CAS Google Scholar
Teo, B. K. (1986). EXAFS: Basic Principles and Data Analysis. Berlin: Springer. Google Scholar
Yachandra, V. K. (1995). Methods Enzymol. 246, 638–678. CrossRef CAS PubMed Web of Science Google Scholar
Yachandra, V. K., Guiles, R. D., McDermott, A. E., Cole, J. L., Britt, R. D., Dexheimer, S. L., Sauer, K. & Klein, M. P. (1987). Biochemistry, 26, 5974–5981. CrossRef CAS PubMed Web of Science Google Scholar
Zouni, A., Witt, H.-T., Kern, J., Fromme, P., Krauß, N., Saenger, W. & Orth, P. (2001). Nature (London), 409, 739–743. Web of Science CrossRef PubMed CAS Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.