checkCIF procedure
PLAT057
PLAT057 Type_3 Test for correction for absorption needed
You have indicated that an absorption correction has not been applied. ('_exptl_absorpt_correction_type' 'none'). However, the predicted values of Tmin & Tmax, based on the crystal dimensions given in the '.cif' file, are sufficiently unequal that absorption effects appear to be significant. Therefore, the application of a suitable absorption correction would appear to be required. Also check that the crystal dimensions given in the CIF do represent the actual crystal dimensions as closely as possible. Inaccuracies here can lead to a poor prediction of Tmin & Tmax and give rise to these alerts. It should normally be possible to estimate the crystal dimensions to 2 decimal places. Rough estimates to only 1 decimal place may be too inaccurate to provide reliable estimates of Tmin & Tmax.