A compact von Hámos spectrometer for parallel X-ray Raman scattering and X-ray emission spectroscopy at ID20 of the European Synchrotron Radiation Facility

crossmark logo

aESRF – The European Synchrotron, 71 Avenue des Martyrs, CS40220, 38000 Grenoble, France, bHelmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Resource Ecology, PO Box 510119, 01314 Dresden, Germany, cThe Rossendorf Beamline at ESRF – The European Synchrotron, CS40220, 38043 Grenoble Cedex 9, France, and dDepartment of Earth Sciences, ETH Zürich, Zürich 8092, Switzerland
*Correspondence e-mail: sahle@esrf.fr

Edited by K. Kvashnina, ESRF – The European Synchrotron, France (Received 29 October 2022; accepted 21 November 2022)

A compact spectrometer for medium-resolution resonant and non-resonant X-ray emission spectroscopy in von Hámos geometry is described. The main motivation for the design and construction of the spectrometer is to allow for acquisition of non-resonant X-ray emission spectra while measuring non-resonant X-ray Raman scattering spectra at beamline ID20 of the European Synchrotron Radiation Facility. Technical details are provided and the performance and possible use of the spectrometer are demonstrated by presenting results of several X-ray spectroscopic methods on various compounds.

1. Introduction

The arrival of the first hard X-ray free-electron lasers has led to a renewed interest in energy-dispersive spectrometers. The extremely short pulse length as well as small, yet persistent, beam jitter (in time, position, intensity and energy) still renders the use of point-by-point scanning spectrometers difficult at these new sources, therefore explaining the regained attention toward dispersive spectrometers, which enable the recording of an entire spectrum from a single X-ray pulse (Alonso-Mori et al., 2012a[Alonso-Mori, R., Kern, J., Gildea, R. J., Sokaras, D., Weng, T.-C., Lassalle-Kaiser, B., Tran, R., Hattne, J., Laksmono, H., Hellmich, J., Glöckner, C., Echols, N., Sierra, R. G., Schafer, D. W., Sellberg, J., Kenney, C., Herbst, R., Pines, J., Hart, P., Herrmann, S., Grosse-Kunstleve, R. W., Latimer, M. J., Fry, A. R., Messerschmidt, M. M., Miahnahri, A., Seibert, M. M., Zwart, P. H., White, W. E., Adams, P. D., Bogan, M. J., Boutet, S., Williams, G. J., Zouni, A., Messinger, J., Glatzel, P., Sauter, N. K., Yachandra, V. K., Yano, J. & Bergmann, U. (2012a). Proc. Natl Acad. Sci. USA, 109, 19103-19107.],b[Alonso-Mori, R., Kern, J., Sokaras, D., Weng, T.-C., Nordlund, D., Tran, R., Montanez, P., Delor, J., Yachandra, V. K., Yano, J. & Bergmann, U. (2012b). Rev. Sci. Instrum. 83, 073114.]).

Naturally, the same instruments can be used at synchrotron beamlines for hard resonant and non-resonant X-ray spectroscopy experiments, including (resonant and non-resonant) X-ray emission spectroscopy [(R)XES] and (resonant and non-resonant) inelastic X-ray scattering spectroscopy [(R)IXS]. These type of X-ray spectroscopies have found their way into physics (Herrero-Martín et al., 2010[Herrero-Martín, J., Mirone, A., Fernández-Rodríguez, J., Glatzel, P., García, J., Blasco, J. & Geck, J. (2010). Phys. Rev. B, 82, 075112.]; Vankó et al., 2006a[Vankó, G., Rueff, J., Mattila, A., Németh, Z. & Shukla, A. (2006a). Phys. Rev. B, 73, 024424.]), chemistry (Vankó et al., 2010[Vankó, G., Glatzel, P., Pham, V., Abela, R., Grolimund, D., Borca, C., Johnson, S., Milne, C. & Bressler, C. (2010). Angew. Chem. 122, 6046-6048.], 2006b[Vankó, G., Neisius, T., Molnár, G., Renz, F., Kárpáti, S., Shukla, A. & de Groot, F. M. F. (2006b). J. Phys. Chem. B, 110, 11647-11653.]; Sá, 2014[Sá, J. (2014). High-Resolution XAS/XES: Analyzing Electronic Structures of Catalysts. CRC Press.]; Pollock & DeBeer, 2015[Pollock, C. J. & DeBeer, S. (2015). Acc. Chem. Res. 48, 2967-2975.]), the geo-sciences (Badro et al., 2003[Badro, J., Fiquet, G., Guyot, F., Rueff, J., Struzhkin, V. V., Vankó, G. & Monaco, G. (2003). Science, 300, 789-791.]; Lin et al., 2007[Lin, J.-F., Vankó, G., Jacobsen, S. D., Iota, V., Struzhkin, V. V., Prakapenka, V. B., Kuznetsov, A. & Yoo, C.-S. (2007). Science, 317, 1740-1743.]) and biology (Lancaster et al., 2011[Lancaster, K. M., Roemelt, M., Ettenhuber, P., Hu, Y., Ribbe, M. W., Neese, F., Bergmann, U. & DeBeer, S. (2011). Science, 334, 974-977.]).

In the context of non-resonant IXS of hard X-rays, or X-ray Raman scattering (XRS) spectroscopy, the incident energies used to study shallow absorption edges often lie well above the K-shell binding energies of 3d transition metal elements, such as iron, cobalt and nickel, and/or above the L- and M-shell binding energies of the lanthanides and actinides. The use of a dispersive spectrometer, therefore, would allow for the measurement of non-resonant core-to-core and valence-to-core emission lines simultaneously and fully independently of the XRS signal, yielding complementary information from the low-Z and, for example, 3d transition metal elements in the investigated sample (Weis et al., 2019[Weis, C., Spiekermann, G., Sternemann, C., Harder, M., Vankó, G., Cerantola, V., Sahle, C. J., Forov, Y., Sakrowski, R., Kupenko, I., Petitgirard, S., Yavaş, H., Bressler, C., Gawelda, W., Tolan, M. & Wilke, M. (2019). J. Anal. At. Spectrom. 34, 384-393.]). The most prominent geometry for dispersive X-ray spectroscopy is the von Hámos geometry (von Hámos, 1938[Hámos, L. V. (1938). J. Sci. Instrum. 15, 87-94.]) based on cylindrically bent analyzer crystals.

Dispersive X-ray spectrometers in von Hámos geometry exist in many shapes and sizes. Recent developments include specialized setups for multiple emission-line detection experiments (Hayashi et al., 2008[Hayashi, K., Nakajima, K., Fujiwara, K. & Nishikata, S. (2008). Rev. Sci. Instrum. 79, 033110.]; Kalinko et al., 2020[Kalinko, A., Caliebe, W. A., Schoch, R. & Bauer, M. (2020). J. Synchrotron Rad. 27, 31-36. ]), setups at free-electron lasers allowing high and ultrahigh time resolution (Szlachetko et al., 2012[Szlachetko, J., Nachtegaal, M., de Boni, E., Willimann, M., Safonova, O., Sa, J., Smolentsev, G., Szlachetko, M., van Bokhoven, J. A., Dousse, J.-C., Hoszowska, J., Kayser, Y., Jagodzinski, P., Bergamaschi, A., Schmitt, B., David, C. & Lücke, A. (2012). Rev. Sci. Instrum. 83, 103105.]; Alonso-Mori et al., 2012a[Alonso-Mori, R., Kern, J., Gildea, R. J., Sokaras, D., Weng, T.-C., Lassalle-Kaiser, B., Tran, R., Hattne, J., Laksmono, H., Hellmich, J., Glöckner, C., Echols, N., Sierra, R. G., Schafer, D. W., Sellberg, J., Kenney, C., Herbst, R., Pines, J., Hart, P., Herrmann, S., Grosse-Kunstleve, R. W., Latimer, M. J., Fry, A. R., Messerschmidt, M. M., Miahnahri, A., Seibert, M. M., Zwart, P. H., White, W. E., Adams, P. D., Bogan, M. J., Boutet, S., Williams, G. J., Zouni, A., Messinger, J., Glatzel, P., Sauter, N. K., Yachandra, V. K., Yano, J. & Bergmann, U. (2012a). Proc. Natl Acad. Sci. USA, 109, 19103-19107.],b[Alonso-Mori, R., Kern, J., Sokaras, D., Weng, T.-C., Nordlund, D., Tran, R., Montanez, P., Delor, J., Yachandra, V. K., Yano, J. & Bergmann, U. (2012b). Rev. Sci. Instrum. 83, 073114.]) as well as extreme conditions (Kaa et al., 2022[Kaa, J. M., Sternemann, C., Appel, K., Cerantola, V., Preston, T. R., Albers, C., Elbers, M., Libon, L., Makita, M., Pelka, A., Petitgirard, S., Plückthun, C., Roddatis, V., Sahle, C. J., Spiekermann, G., Schmidt, C., Schreiber, A., Sakrowski, R., Tolan, M., Wilke, M., Zastrau, U. & Konôpková, Z. (2022). Phys. Rev. Res. 4, 033042.]), and simple, yet effective, short-working-distance spectrometers (Mattern et al., 2012[Mattern, B. A., Seidler, G. T., Haave, M., Pacold, J. I., Gordon, R. A., Planillo, J., Quintana, J. & Rusthoven, B. (2012). Rev. Sci. Instrum. 83, 023901.]; Pacold et al., 2012[Pacold, J. I., Bradley, J. A., Mattern, B. A., Lipp, M. J., Seidler, G. T., Chow, P., Xiao, Y., Rod, E., Rusthoven, B. & Quintana, J. (2012). J. Synchrotron Rad. 19, 245-251.]). If requirements to the spectrometer energy resolution are slightly relaxed, high-quality non-resonant XES spectra can be obtained in the laboratory using cylindrically bent highly annealed pyrolitic graphite as analyzer crystals (Anklamm et al., 2014[Anklamm, L., Schlesiger, C., Malzer, W., Grötzsch, D., Neitzel, M. & Kanngießer, B. (2014). Rev. Sci. Instrum. 85, 053110.]; Malzer et al., 2018[Malzer, W., Grötzsch, D., Gnewkow, R., Schlesiger, C., Kowalewski, F., Van Kuiken, B., DeBeer, S. & Kanngießer, B. (2018). Rev. Sci. Instrum. 89, 113111.]; Zimmermann et al., 2020[Zimmermann, P., Peredkov, S., Abdala, P. M., DeBeer, S., Tromp, M., Müller, C. & van Bokhoven, J. A. (2020). Coord. Chem. Rev. 423, 213466.]). Furthermore, von Hámos spectrometers are important diagnostic tools at plasma sources (Shevelko et al., 2002[Shevelko, A. P., Kasyanov, Y. S., Yakushev, O. F. & Knight, L. V. (2002). Rev. Sci. Instrum. 73, 3458-3463.]; Notley et al., 2006[Notley, M. M., Weber, R. L., Fell, B., Jeffries, J., Freeman, R. R., Mackinnon, A. J., Dickson, R., Hey, D., Khattak, F., Saiz, E. G. & Gregori, G. (2006). Rev. Sci. Instrum. 77, 10F322.]).

Here, we present a new von Hámos spectrometer for beamline ID20 of the European Synchrotron Radiation Facility, optimized for non-resonant XES measurements during acquisition of XRS spectra. The new spectrometer is based on three cylindrically bent analyzer crystals with bending radius of R = 250 mm housed in a compact vacuum chamber for high signal-to-noise ratio and maximum ease of use and alignment.

The spectrometer, of course, also allows for other flavors of X-ray spectroscopy, such as RXES, including partial fluorescence yield or high-energy-resolution fluorescence-detected (HERFD) X-ray absorption spectroscopy (XAS) studies (Glatzel & Bergmann, 2005[Glatzel, P. & Bergmann, U. (2005). Coord. Chem. Rev. 249, 65-95.]; Arandia et al., 2023[Arandia, A., Yim, J., Warraich, H., Leppäkangas, E., Bes, R., Lempelto, A., Gell, L., Jiang, H., Meinander, K., Viinikainen, T., Huotari, S., Honkala, K. & Puurunen, R. L. (2023). Appl. Catal. Environ. 321, 122046.]) and RIXS [including X-ray magnetic circular dichroism (XMCD and RIXS–MCD) experiments (Sikora et al., 2012[Sikora, M., Juhin, A., Simon, G., Zając, M., Biernacka, K., Kapusta, C., Morellon, L., Ibarra, M. R. & Glatzel, P. (2012). J. Appl. Phys. 111, 07E301.])]. However, even though feasible in von Hámos geometry, Johann or Johansson spectrometers may be better suited for resonant techniques (RXES, RIXS) and partial-fluorescence-yield measurements (HERFD XAS).

Here, we present the design and performance of the spectrometer and show several examples of applications.

2. Technical details

Figs. 1[link](a) and 1[link](b) show 3D-rendered representations of technical drawings of the entire von Hámos spectrometer. We followed four principle ideas during the design of the spectrometer: compactness, portability, optimized signal-to-noise ratio, and maximum ease of spectrometer alignment and use.

[Figure 1]
Figure 1
(a, b) Three-dimensional renderings of technical drawings of the von Hámos spectrometer. (a) An orthographic view of the entire chamber including the used Maxipix pixel detector. (b) Same as (a) but with a transparent vacuum chamber. (c) A schematic drawing of the von Hámos geometry; for clarity only the central analyzer crystal is shown (S: source/sample; R: crystal-analyzer bending radius; D: detector; dz: detector position; A: analyzer; az: vertical analyzer position; ay: horizontal analyzer position; [\Theta_{{\rm B}}]: Bragg angle; H: analyzer height; w: analyzer width; δaz: vertical deviation from the ideal sample position; δay: horizontal deviation from the ideal sample position). (d)–(f) Sections of typical detector images showing the footprints of non-resonant XES from a germanium single-crystal sample. Possible regions of interest are indicated with thin dashed black lines. Images are shown on a logarithmic intensity scale.

The entire spectrometer consists of a single lightweight composite carbon-fiber vacuum chamber containing both the movable three-analyzer-crystal goniometer array as well as the motorized detector. The use of a vacuum chamber helps to minimize absorption and parasitic scattering from air (the typical used pressure is ∼10−2 mbar). The rigid chamber furthermore simplifies the alignment of the spectrometer at different spectrometer energies since both the analyzer and detector translations are motorized. This rigid design also simplifies the adjustment of the sample-to-analyzer direction such that it lies parallel to the polarization vector of the incident X-ray beam. Due to the finite size of the vacuum chamber, analyzer Bragg angles in the the range of ca. [\Theta_{{\rm B}}] = 45–85° are available.

As mentioned, the goniometer array allows for three cylindrically bent crystal analyzers with a meridional bending radius of R = 250 mm. Each analyzer crystal is 25 mm high and 110 mm wide. At present, Si(n,n,n), Si(n,n,0) and Si(n,0,0) analyzer crystals are available. The three analyzer crystals are mounted on a common translation axis parallel to the central analyzer's cylinder axis. The cylinder axes of the outer two crystals are tilted by ±5° with respect to that of the central analyzer to roughly allow the same range of Bragg angles as the central analyzer crystal for a common detector position (Alonso-Mori et al., 2012a[Alonso-Mori, R., Kern, J., Gildea, R. J., Sokaras, D., Weng, T.-C., Lassalle-Kaiser, B., Tran, R., Hattne, J., Laksmono, H., Hellmich, J., Glöckner, C., Echols, N., Sierra, R. G., Schafer, D. W., Sellberg, J., Kenney, C., Herbst, R., Pines, J., Hart, P., Herrmann, S., Grosse-Kunstleve, R. W., Latimer, M. J., Fry, A. R., Messerschmidt, M. M., Miahnahri, A., Seibert, M. M., Zwart, P. H., White, W. E., Adams, P. D., Bogan, M. J., Boutet, S., Williams, G. J., Zouni, A., Messinger, J., Glatzel, P., Sauter, N. K., Yachandra, V. K., Yano, J. & Bergmann, U. (2012a). Proc. Natl Acad. Sci. USA, 109, 19103-19107.]). This, however, results in the fact that only the central analyzer crystal produces a perfect focus across the entire dispersion footprint on the detector surface [compare Figs. 1[link](d)–1[link](f)]. The analyzer goniometer array allows for three individual degrees of motion for each analyzer crystal: [\Theta] and χ rotation, as well as translation along the focus direction.

The X-rays are detected by a 5 × 1 Maxipix hybrid pixel detector (500 µm sensor thickness) with 55 µm × 55 µm pixel size and 14 mm × 70 mm active surface area (Ponchut et al., 2011[Ponchut, C., Rigal, J. M., Clément, J., Papillon, E., Homs, A. & Petitdemange, S. (2011). J. Instrum. 6, C01069.]). Sections of typical detector images showing the X-ray emission spectrum of a germanium single-crystal sample as a footprint for each of three Si(6,6,0) analyzer crystals are shown in Figs. 1[link](d)–1[link](f). Possible regions of interest are shown as thin dashed black lines.

The solid angle covered by the spectrometer is given by

[{\Omega} = {n}_{\rm cryst}\int\limits_{\phi_1}^{\phi_2}\int\limits_{\Theta_2}^{\Theta_1} \sin \Theta\, {\rm d}\Theta\,{\rm d}\phi, \eqno (1)]

where ncryst is the number of analyzer crystals and the integral limits are defined by the extent of each of the analyzer crystals and their orientation inside the spectrometer chamber. For the presented spectrometer, the solid angle is of the order of 1% of 4π (energy integrated).

The energy dispersion and energy window simply follow from Bragg's law,

[E = {{hc}\over{2d\sin\Theta_{\rm B}}}, \eqno (2)]

and the spectrometer geometry,

[{{\delta{E}}\over{\delta{c_z}}} = {E} \cot\Theta_{\rm B} {{R}\over{R^2 + c_z^2}} \eqno (3)]

where R is the cylindrical curvature of the analyzer crystals, E is the central energy and cz is the vertical analyzer coordinate. The dispersion relation as well as the energy windows covered (shaded areas) for several reflections of the Si(n,n,n) and Si(n,n,0) lattice plane family over the available angular range of the spectrometer are shown in Fig. 2[link](a).

[Figure 2]
Figure 2
(a) DuMond diagram for bent R = 250 mm Si crystals for different (n,n,0) and (n,n,n) lattice planes. Shaded areas represent the energy window covered by the analyzer crystals. (b)–(i) Calculated (colored) and experimental (thin dashed) reflectivity curves between ca. 6 and 17 keV. All theoretical reflectivity curves were obtained by solving the 1D Tagaki–Taupin equations (Takagi, 1962[Takagi, S. (1962). Acta Cryst. 15, 1311-1312.], 1969[Takagi, S. (1969). J. Phys. Soc. Jpn, 26, 1239-1253.]; Taupin, 1964[Taupin, D. (1964). Bull. Minéral. 87, 469-511.]) using the pyTTE package by Honkanen & Huotari (2021[Honkanen, A.-P. & Huotari, S. (2021). IUCrJ, 8, 102-115.]).

3. Energy resolution

The overall energy resolution of the setup is determined by the bandwidth of the incident X-ray photon beam ΔEin, the bandwidth of the analyzer crystals ΔETT, and the source size contributions in the horizontal ΔEy and vertical ΔEz directions,

[\Delta{E} = \left(\Delta E_{\rm in}^{\,2} + \Delta E_{\rm TT}^{\,2} + \Delta E_{y,z}^{\,2}\right)^{1/2}. \eqno (4)]

Ideally, the overall beamline and spectrometer resolution should be comparable with the lifetime broadening induced by the created core hole. In the case of non-resonant XES, the requirements are further relaxed as the incident X-ray bandwidth does not contribute.

The contribution of the analyzer crystals is given by the width of their X-ray reflectivity curve for the used Bragg reflection. For cylindrically bent crystals these curves can be approximated by solving the Tagaki–Taupin equations (Takagi, 1962[Takagi, S. (1962). Acta Cryst. 15, 1311-1312.], 1969[Takagi, S. (1969). J. Phys. Soc. Jpn, 26, 1239-1253.]; Taupin, 1964[Taupin, D. (1964). Bull. Minéral. 87, 469-511.]). A comparison of these theoretical Tagaki–Taupin reflectivities and experimentally measured elastic lines for different analyzer crystals and reflections are shown in Figs. 2[link](b)–2[link](i). All experimental curves were measured using an Si(3,1,1) channel-cut post-monochromator providing a resolving power of ΔE/E ≃ 2.8 × 10−5 for the incident X-ray beam. The Tagaki–Taupin equations were solved using the pyTTE package by Honkanen & Huotari (2021[Honkanen, A.-P. & Huotari, S. (2021). IUCrJ, 8, 102-115.]). Compression stress, as discussed by Honkanen et al. (2014[Honkanen, A.-P., Verbeni, R., Simonelli, L., Moretti Sala, M., Monaco, G. & Huotari, S. (2014). J. Synchrotron Rad. 21, 104-110.], 2017[Honkanen, A.-P., Verbeni, R., Simonelli, L., Moretti Sala, M., Monaco, G. & Huotari, S. (2017). J. Synchrotron Rad. 24, 545-546.]) for cylindrically bent crystals, or finite analyzer size are not accounted for in the presented simulated reflectivity curves.

The source size contribution follows from the dispersion relation [equation (3[link])] and the variation of the Bragg angle [\Theta_{{\rm B}}] as a function of the horizontal and vertical deviation from a perfect point source,

[{{\delta{E}}\over{E}} = -\cot\Theta_{\rm B} {{\delta {a}_{y}}\over{(R^{2}/c_{z}) + c_z}}, \eqno (5)]

and

[{{\delta{E}}\over{E}} = \cot\Theta_{\rm B} {{R\delta {a}_{z}}\over{R^{2} + c_{z}^{2}}}.\eqno (6)]

The finite detector pixel size p contributes via a dispersion similar to equation (3[link]) if cz is replaced by dz = 2cz, the detector coordinate. This contribution is of the order of a few hundred meV at large [\Theta_{{\rm B}}]. Here, we have not explicitly considered this contribution as the pixelated area detector can be translated parallel to the analyzer cylinder axis, and several detector exposures at different vertical positions incommensurate with the detector pixel spacing can be combined to a virtual arbitrary pixel size along the dispersive direction. The translation along the dispersive direction furthermore enables the recording of smooth and continuous spectra even at emission energies that correspond to the detector-chip corners. The achievable overall energy resolution is well below the broadening resulting from the finite lifetime of deep core holes in intermediate-Z elements.

4. Examples

4.1. Non-resonant X-ray emission spectroscopy

Fig. 3[link] shows examples of non-resonant Kβ core-to-core and valence-to-core X-ray emission lines of different elements. The spectra were taken with incident energies 200 eV above the respective absorption edge and exposure times of 7 min per spectrum. The photon flux at the sample was 1 × 1013 photons s−1 within a 10 µm × 10 µm spot size. Fig. 3[link](a) shows the Y Kβ emission line from a 25 µm-thick yttrium foil measured using the Si(8,8,0) reflection at a mean Bragg angle of [\Theta_{\rm B}] = 50° [see Fig. 2[link](d)]. The signal from all three analyzer crystals was averaged over. Fig. 3[link](b) depicts a spectrum of the Kβ and valence-to-core emission line of Ge from a millimetre-sized Ge single-crystal sample using three Si(6,6,0) analyzer crystals with a central Bragg angle of [\Theta_{\rm B}] = 61° [resolution function shown in Fig. 2[link](f)]. Fig. 3[link](c) shows Kβ and valence-to-core emission lines of Zn from a 25 µm-thick Zn foil. Here, the spectra represent averaged signals from three Si(4,4,4) analyzer crystals at a mean Bragg angle of [\Theta_{\rm B}] = 55° [resolution function shown in Fig. 2[link](g)]. The Kβ and valence-to-core emission lines of Mn from a small pellet of polycrystalline MnO2 (grain size <10 µm) are shown in Fig. 3[link](d) [resolution function shown in Fig. 2[link](i)]. We used a single Si(3,3,3) analyzer crystal at a central Bragg angle of [\Theta_{\rm B}] = 65°.

[Figure 3]
Figure 3
Examples of non-resonant Kβ XES spectra. The insets show the valence-to-core (vtc) regions of the respective spectra. (a) An yttrium Kβ XES spectrum of an yttrium foil. (b) A Ge Kβ XES spectrum of a Ge foil. (c) A Zn Kβ XES spectrum of a polycrystalline ZnO powder sample. (d) A Mn Kβ XES spectrum of a polycrystalline MnO powder sample.

These examples show that high-quality non-resonant core-to-core and valence-to-core XES spectra over the entire energy range available at ID20 can be measured on a minute timescale, which renders this setup perfectly suitable for simultaneous measurements of XRS spectra of low- and intermediate-Z elements and non-resonant XES from, for example, 3d transition metals.

4.2. Combined XRS and XES

One of the main motivations driving the development of this compact and mobile von Hámos spectrometer is the prospect of studying non-resonant X-ray emission lines while measuring non-resonant IXS spectra of shallow bound electrons, so-called XRS spectroscopy. The hard X-rays used for XRS spectroscopy are often well above, for example, the K-shell binding energies of 3d transition metals or the L-shell binding energies of 5d and 4f elements. Among the first of such combined XES and XRS experiments, Weis et al. (2019[Weis, C., Spiekermann, G., Sternemann, C., Harder, M., Vankó, G., Cerantola, V., Sahle, C. J., Forov, Y., Sakrowski, R., Kupenko, I., Petitgirard, S., Yavaş, H., Bressler, C., Gawelda, W., Tolan, M. & Wilke, M. (2019). J. Anal. At. Spectrom. 34, 384-393.]) simultaneously measured the Fe Kβ1,3 and Fe valence-to-core-emission lines via non-resonant XES and the Fe M2,3-edge via XRS in order to study the pressure-induced spin transition in siderite (FeCO3).

Fig. 4[link] shows simultaneously measured XES and XRS spectra of a copper-exchanged zeolite with chabazite topology at ambient conditions. This zeolite and similar copper-exchanged molecular sieves are promising catalyst candidates for the direct conversion of methane to methanol (Borfecchia et al., 2018[Borfecchia, E., Beato, P., Svelle, S., Olsbye, U., Lamberti, C. & Bordiga, S. (2018). Chem. Soc. Rev. 47, 8097-8133.]). Despite recent advances, key research questions remain open about the chemical identity and electronic structure of Cu and/or participating oxygen species formed during thermal treatment in an oxidizing atmosphere. These investigations are challenging based on Cu K-edge XAS alone (Borfecchia et al., 2015[Borfecchia, E., Lomachenko, K. A., Giordanino, F., Falsig, H., Beato, P., Soldatov, A. V., Bordiga, S. & Lamberti, C. (2015). Chem. Sci. 6, 548-563.]; Martini et al., 2017[Martini, A., Borfecchia, E., Lomachenko, K. A., Pankin, I. A., Negri, C., Berlier, G., Beato, P., Falsig, H., Bordiga, S. & Lamberti, C. (2017). Chem. Sci. 8, 6836-6851.]; Pappas et al., 2017[Pappas, D. K., Borfecchia, E., Dyballa, M., Pankin, I. A., Lomachenko, K. A., Martini, A., Signorile, M., Teketel, S., Arstad, B., Berlier, G., Lamberti, C., Bordiga, S., Olsbye, U., Lillerud, K. P., Svelle, S. & Beato, P. (2017). J. Am. Chem. Soc. 139, 14961-14975.], 2018[Pappas, D. K., Martini, A., Dyballa, M., Kvande, K., Teketel, S., Lomachenko, K. A., Baran, R., Glatzel, P., Arstad, B., Berlier, G., Lamberti, C., Bordiga, S., Olsbye, U., Svelle, S., Beato, P. & Borfecchia, E. (2018). J. Am. Chem. Soc. 140, 15270-15278.]). Simultaneously measured XES and XRS offer the necessary bulk sensitivity to probe these intermediates dispersed in the whole microporous solid and, in addition, are a unique opportunity to access element-selective information on extra-framework O and C species evolving during the reaction. Fig. 4[link](a) shows the Cu Kβ emission line and the zoomed-in valence-to-core region in the inset. The Cu Kβ′′ line is clearly visible at ∼8.96 keV emission energy. Figs. 4[link](b) and 4[link](c) show the Si L2,3- and O K-edge of the zeolite, respectively. The measurement time for the data shown in Fig. 4[link] was 80 min and the overall resolution for the XES setup using a single cylindrically bent Si(5,5,5) analyzer crystal was 1.5 eV. For the XRS setup with 24 spherically bent Si(6,6,0) analyzer crystals, a resolution of 0.7 eV was achieved (Huotari et al., 2017[Huotari, S., Sahle, C. J., Henriquet, C., Al-Zein, A., Martel, K., Simonelli, L., Verbeni, R., Gonzalez, H., Lagier, M.-C., Ponchut, C., Moretti Sala, M., Krisch, M. & Monaco, G. (2017). J. Synchrotron Rad. 24, 521-530.]).

[Figure 4]
Figure 4
(a) A non-resonant X-ray emission spectrum of the Cu Kβ emission line, as well as the valence-to-core part of the same emission line of a copper-exchange zeolite. (b) An Si L2,3-edge excitation spectrum measured at high momentum transfer q and (c) an O K-edge spectrum at low momentum transfer of the same sample. The XES spectra were measured simultaneously to the two XRS spectra.

This example shows the great potential resulting from a combination of XRS with XES to study, at the same time, low-Z absorption edges via XRS and heavier elements, such as 3d transition metal elements, via non-resonant XES. Especially in the valence-to-core region of the emission spectra, XES and XRS provide complementary information on the electronic structure of the studied sample. The advantage of this approach is that both probes make use of hard X-ray photons, which are compatible with complex sample environments such as in situ and operando cells for the study of chemical processes and reactions and/or high-pressure diamond anvil cells for the study of samples under extreme pressure conditions (Petitgirard et al., 2017[Petitgirard, S., Spiekermann, G., Weis, C., Sahle, C., Sternemann, C. & Wilke, M. (2017). J. Synchrotron Rad. 24, 276-282.], 2019[Petitgirard, S., Jacobs, J., Cerantola, V., Collings, I. E., Tucoulou, R., Dubrovinsky, L. & Sahle, C. J. (2019). Rev. Sci. Instrum. 90, 095107.]).

4.3. Resonant X-ray emission spectroscopy

The ability to record an emission spectrum at electronvolt resolution over tens of electronvolts renders the von Hámos spectrometer well suited to record entire resonant X-ray emission maps by simply varying the incident photon energy across one of the system's resonances.

This type of spectroscopy is often also referred to as RIXS; however, here we do not show momentum-transfer resolved spectra and therefore refrain from using the term `scattering'.

As an example of such resonance maps, Fig. 5[link] shows data at the Fe K-edge resonance recorded with left- and right-circularly polarized incident X-rays, as first observed at resonance by Krisch et al. (1996[Krisch, M. H., Sette, F., Bergmann, U., Masciovecchio, C., Verbeni, R., Goulon, J., Caliebe, W. & Kao, C. C. (1996). Phys. Rev. B, 54, R12673-R12676.]) for gadolinium. Sikora et al. (2010[Sikora, M., Juhin, A., Weng, T. C., Sainctavit, P., Detlefs, C., de Groot, F. & Glatzel, P. (2010). Phys. Rev. Lett. 105, 037202.]) showed the increased XMCD in the vicinity of the Fe K-edge for magnetite using these types of resonance maps.

[Figure 5]
Figure 5
(a) An RXES map of an NdFeB permanent magnet measured at the Fe K-edge (resulting from the sum of two RXES maps measured with circular-left and circular-right polarized photons). (b) RXES–MCD shown as a difference map (in %) of the two RXES maps.

Fig. 5[link](a) shows the 1s2p RXES plane measured at the Fe K-edge of an NdFeB permanent magnet as a result of the sum of two resonance maps recorded with circularly left- and right-polarized X-rays. Fig. 5[link](b) shows the MCD map of the same data resulting from the difference between the two RXES maps.

Here, we used X-rays from three consecutive U32 undulators and an Si(1,1,1) high-heatload double-crystal monochromator. Circular left- and right-handed polarized X-ray beams were produced using a double phase-plate setup in quarter wave-plate mode [2 × 0.6 mm-thick diamond-〈110〉 phase plates using the (1,1,1) reflection in Laue geometry]. The setup provides high-purity polarization, but at the expense of only ∼18% transmission at the Fe K-edge (7.112 keV). The double phase-plate configuration compensates the vertical beam divergence and energy-dispersion contribution to the depolarization of the X-ray beam (Scagnoli et al., 2009[Scagnoli, V., Mazzoli, C., Detlefs, C., Bernard, P., Fondacaro, A., Paolasini, L., Fabrizi, F. & de Bergevin, F. (2009). J. Synchrotron Rad. 16, 778-787.]). The working point orientation of the retarder plates was calibrated prior to the experiment to follow the incident photon energy for each scan. To record the emission spectra for different incident energies, we used a single cylindrically bent Si(4,4,0) analyzer crystal at a mean Bragg angle of approximately [\Theta_{{\rm B}}] = 65°. In combination with the incident energy bandwidth from the monochromator, the overall energy resolution was 1.9 eV.

5. Summary and conclusions

A new compact and portable dispersive X-ray spectrometer in von Hámos geometry is available at ID20. The spectrometer is optimized for measurements of non-resonant X-ray emission spectra while acquiring X-ray Raman scattering spectra; however, it is also available for standalone resonant and non-resonant X-ray emission spectroscopy measurement. We have described the technical details of this low-noise spectrometer and have presented various examples of the use of this new spectrometer at the European Synchrotron Radiation Facility.

Acknowledgements

We acknowledge the European Synchrotron Radiation Facility for provision of synchrotron radiation facilities. Elisa Borfecchio, Andrea Martini, Gabriele Deplano and Mario Rivera Salazar are warmly thanked for providing experimental data on the copper-exchanged zeolite.

References

First citationAlonso-Mori, R., Kern, J., Gildea, R. J., Sokaras, D., Weng, T.-C., Lassalle-Kaiser, B., Tran, R., Hattne, J., Laksmono, H., Hellmich, J., Glöckner, C., Echols, N., Sierra, R. G., Schafer, D. W., Sellberg, J., Kenney, C., Herbst, R., Pines, J., Hart, P., Herrmann, S., Grosse-Kunstleve, R. W., Latimer, M. J., Fry, A. R., Messerschmidt, M. M., Miahnahri, A., Seibert, M. M., Zwart, P. H., White, W. E., Adams, P. D., Bogan, M. J., Boutet, S., Williams, G. J., Zouni, A., Messinger, J., Glatzel, P., Sauter, N. K., Yachandra, V. K., Yano, J. & Bergmann, U. (2012a). Proc. Natl Acad. Sci. USA, 109, 19103–19107.  Web of Science CAS PubMed Google Scholar
First citationAlonso-Mori, R., Kern, J., Sokaras, D., Weng, T.-C., Nordlund, D., Tran, R., Montanez, P., Delor, J., Yachandra, V. K., Yano, J. & Bergmann, U. (2012b). Rev. Sci. Instrum. 83, 073114.  Web of Science PubMed Google Scholar
First citationAnklamm, L., Schlesiger, C., Malzer, W., Grötzsch, D., Neitzel, M. & Kanngießer, B. (2014). Rev. Sci. Instrum. 85, 053110.  Web of Science CrossRef PubMed Google Scholar
First citationArandia, A., Yim, J., Warraich, H., Leppäkangas, E., Bes, R., Lempelto, A., Gell, L., Jiang, H., Meinander, K., Viinikainen, T., Huotari, S., Honkala, K. & Puurunen, R. L. (2023). Appl. Catal. Environ. 321, 122046.  Web of Science CrossRef Google Scholar
First citationBadro, J., Fiquet, G., Guyot, F., Rueff, J., Struzhkin, V. V., Vankó, G. & Monaco, G. (2003). Science, 300, 789–791.  Web of Science CrossRef PubMed CAS Google Scholar
First citationBorfecchia, E., Beato, P., Svelle, S., Olsbye, U., Lamberti, C. & Bordiga, S. (2018). Chem. Soc. Rev. 47, 8097–8133.  Web of Science CrossRef CAS PubMed Google Scholar
First citationBorfecchia, E., Lomachenko, K. A., Giordanino, F., Falsig, H., Beato, P., Soldatov, A. V., Bordiga, S. & Lamberti, C. (2015). Chem. Sci. 6, 548–563.  Web of Science CrossRef CAS PubMed Google Scholar
First citationGlatzel, P. & Bergmann, U. (2005). Coord. Chem. Rev. 249, 65–95.  Web of Science CrossRef CAS Google Scholar
First citationHámos, L. V. (1938). J. Sci. Instrum. 15, 87–94.  Google Scholar
First citationHayashi, K., Nakajima, K., Fujiwara, K. & Nishikata, S. (2008). Rev. Sci. Instrum. 79, 033110.  Web of Science CrossRef PubMed Google Scholar
First citationHerrero-Martín, J., Mirone, A., Fernández-Rodríguez, J., Glatzel, P., García, J., Blasco, J. & Geck, J. (2010). Phys. Rev. B, 82, 075112.  Google Scholar
First citationHonkanen, A.-P. & Huotari, S. (2021). IUCrJ, 8, 102–115.  Web of Science CrossRef CAS PubMed IUCr Journals Google Scholar
First citationHonkanen, A.-P., Verbeni, R., Simonelli, L., Moretti Sala, M., Monaco, G. & Huotari, S. (2014). J. Synchrotron Rad. 21, 104–110.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationHonkanen, A.-P., Verbeni, R., Simonelli, L., Moretti Sala, M., Monaco, G. & Huotari, S. (2017). J. Synchrotron Rad. 24, 545–546.  Web of Science CrossRef IUCr Journals Google Scholar
First citationHuotari, S., Sahle, C. J., Henriquet, C., Al-Zein, A., Martel, K., Simonelli, L., Verbeni, R., Gonzalez, H., Lagier, M.-C., Ponchut, C., Moretti Sala, M., Krisch, M. & Monaco, G. (2017). J. Synchrotron Rad. 24, 521–530.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationKaa, J. M., Sternemann, C., Appel, K., Cerantola, V., Preston, T. R., Albers, C., Elbers, M., Libon, L., Makita, M., Pelka, A., Petitgirard, S., Plückthun, C., Roddatis, V., Sahle, C. J., Spiekermann, G., Schmidt, C., Schreiber, A., Sakrowski, R., Tolan, M., Wilke, M., Zastrau, U. & Konôpková, Z. (2022). Phys. Rev. Res. 4, 033042.  Web of Science CrossRef Google Scholar
First citationKalinko, A., Caliebe, W. A., Schoch, R. & Bauer, M. (2020). J. Synchrotron Rad. 27, 31–36.   Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationKrisch, M. H., Sette, F., Bergmann, U., Masciovecchio, C., Verbeni, R., Goulon, J., Caliebe, W. & Kao, C. C. (1996). Phys. Rev. B, 54, R12673–R12676.  CrossRef CAS Web of Science Google Scholar
First citationLancaster, K. M., Roemelt, M., Ettenhuber, P., Hu, Y., Ribbe, M. W., Neese, F., Bergmann, U. & DeBeer, S. (2011). Science, 334, 974–977.  Web of Science CrossRef CAS PubMed Google Scholar
First citationLin, J.-F., Vankó, G., Jacobsen, S. D., Iota, V., Struzhkin, V. V., Prakapenka, V. B., Kuznetsov, A. & Yoo, C.-S. (2007). Science, 317, 1740–1743.  Web of Science CrossRef PubMed CAS Google Scholar
First citationMalzer, W., Grötzsch, D., Gnewkow, R., Schlesiger, C., Kowalewski, F., Van Kuiken, B., DeBeer, S. & Kanngießer, B. (2018). Rev. Sci. Instrum. 89, 113111.  Web of Science CrossRef PubMed Google Scholar
First citationMartini, A., Borfecchia, E., Lomachenko, K. A., Pankin, I. A., Negri, C., Berlier, G., Beato, P., Falsig, H., Bordiga, S. & Lamberti, C. (2017). Chem. Sci. 8, 6836–6851.  Web of Science CrossRef CAS PubMed Google Scholar
First citationMattern, B. A., Seidler, G. T., Haave, M., Pacold, J. I., Gordon, R. A., Planillo, J., Quintana, J. & Rusthoven, B. (2012). Rev. Sci. Instrum. 83, 023901.  Web of Science CrossRef PubMed Google Scholar
First citationNotley, M. M., Weber, R. L., Fell, B., Jeffries, J., Freeman, R. R., Mackinnon, A. J., Dickson, R., Hey, D., Khattak, F., Saiz, E. G. & Gregori, G. (2006). Rev. Sci. Instrum. 77, 10F322.  Web of Science CrossRef Google Scholar
First citationPacold, J. I., Bradley, J. A., Mattern, B. A., Lipp, M. J., Seidler, G. T., Chow, P., Xiao, Y., Rod, E., Rusthoven, B. & Quintana, J. (2012). J. Synchrotron Rad. 19, 245–251.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationPappas, D. K., Borfecchia, E., Dyballa, M., Pankin, I. A., Lomachenko, K. A., Martini, A., Signorile, M., Teketel, S., Arstad, B., Berlier, G., Lamberti, C., Bordiga, S., Olsbye, U., Lillerud, K. P., Svelle, S. & Beato, P. (2017). J. Am. Chem. Soc. 139, 14961–14975.  Web of Science CrossRef CAS PubMed Google Scholar
First citationPappas, D. K., Martini, A., Dyballa, M., Kvande, K., Teketel, S., Lomachenko, K. A., Baran, R., Glatzel, P., Arstad, B., Berlier, G., Lamberti, C., Bordiga, S., Olsbye, U., Svelle, S., Beato, P. & Borfecchia, E. (2018). J. Am. Chem. Soc. 140, 15270–15278.  Web of Science CrossRef CAS PubMed Google Scholar
First citationPetitgirard, S., Jacobs, J., Cerantola, V., Collings, I. E., Tucoulou, R., Dubrovinsky, L. & Sahle, C. J. (2019). Rev. Sci. Instrum. 90, 095107.  Web of Science CrossRef PubMed Google Scholar
First citationPetitgirard, S., Spiekermann, G., Weis, C., Sahle, C., Sternemann, C. & Wilke, M. (2017). J. Synchrotron Rad. 24, 276–282.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationPollock, C. J. & DeBeer, S. (2015). Acc. Chem. Res. 48, 2967–2975.  Web of Science CrossRef CAS PubMed Google Scholar
First citationPonchut, C., Rigal, J. M., Clément, J., Papillon, E., Homs, A. & Petitdemange, S. (2011). J. Instrum. 6, C01069.  Web of Science CrossRef Google Scholar
First citationSá, J. (2014). High-Resolution XAS/XES: Analyzing Electronic Structures of Catalysts. CRC Press.  Google Scholar
First citationScagnoli, V., Mazzoli, C., Detlefs, C., Bernard, P., Fondacaro, A., Paolasini, L., Fabrizi, F. & de Bergevin, F. (2009). J. Synchrotron Rad. 16, 778–787.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationShevelko, A. P., Kasyanov, Y. S., Yakushev, O. F. & Knight, L. V. (2002). Rev. Sci. Instrum. 73, 3458–3463.  Web of Science CrossRef CAS Google Scholar
First citationSikora, M., Juhin, A., Simon, G., Zając, M., Biernacka, K., Kapusta, C., Morellon, L., Ibarra, M. R. & Glatzel, P. (2012). J. Appl. Phys. 111, 07E301.  Web of Science CrossRef Google Scholar
First citationSikora, M., Juhin, A., Weng, T. C., Sainctavit, P., Detlefs, C., de Groot, F. & Glatzel, P. (2010). Phys. Rev. Lett. 105, 037202.  Web of Science CrossRef PubMed Google Scholar
First citationSzlachetko, J., Nachtegaal, M., de Boni, E., Willimann, M., Safonova, O., Sa, J., Smolentsev, G., Szlachetko, M., van Bokhoven, J. A., Dousse, J.-C., Hoszowska, J., Kayser, Y., Jagodzinski, P., Bergamaschi, A., Schmitt, B., David, C. & Lücke, A. (2012). Rev. Sci. Instrum. 83, 103105.  Web of Science CrossRef PubMed Google Scholar
First citationTakagi, S. (1962). Acta Cryst. 15, 1311–1312.  CrossRef CAS IUCr Journals Web of Science Google Scholar
First citationTakagi, S. (1969). J. Phys. Soc. Jpn, 26, 1239–1253.  CrossRef CAS Web of Science Google Scholar
First citationTaupin, D. (1964). Bull. Minéral. 87, 469–511.  CAS Google Scholar
First citationVankó, G., Glatzel, P., Pham, V., Abela, R., Grolimund, D., Borca, C., Johnson, S., Milne, C. & Bressler, C. (2010). Angew. Chem. 122, 6046–6048.  Google Scholar
First citationVankó, G., Neisius, T., Molnár, G., Renz, F., Kárpáti, S., Shukla, A. & de Groot, F. M. F. (2006b). J. Phys. Chem. B, 110, 11647–11653.  Web of Science PubMed Google Scholar
First citationVankó, G., Rueff, J., Mattila, A., Németh, Z. & Shukla, A. (2006a). Phys. Rev. B, 73, 024424.  Google Scholar
First citationWeis, C., Spiekermann, G., Sternemann, C., Harder, M., Vankó, G., Cerantola, V., Sahle, C. J., Forov, Y., Sakrowski, R., Kupenko, I., Petitgirard, S., Yavaş, H., Bressler, C., Gawelda, W., Tolan, M. & Wilke, M. (2019). J. Anal. At. Spectrom. 34, 384–393.  Web of Science CrossRef CAS Google Scholar
First citationZimmermann, P., Peredkov, S., Abdala, P. M., DeBeer, S., Tromp, M., Müller, C. & van Bokhoven, J. A. (2020). Coord. Chem. Rev. 423, 213466.  Web of Science CrossRef Google Scholar

This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds