research papers
High-purity X-ray polarimetry at high energies for Mössbauer spectroscopy
aHelmholtz Centre for Heavy Ion Research (GSI), Planckstr. 1, D-64291 Darmstadt, Germany, bHelmholtz Institute Jena, Fröbelstieg 3, D-07743 Jena, Germany, cInstitute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Max-Wien-Platz 1, D-07743 Jena, Germany, and dDESY Photon Science, Notkestr. 85, D-22607 Hamburg, Germany
*Correspondence e-mail: [email protected]
High-purity X-ray polarimetry has so far been established only in the low-energy range up to 14.4 keV and has therefore been applied exclusively to the Mössbauer isotope 57Fe. Here we extend high-purity X-ray polarimetry to photon energies between 15 and 30 keV. Using asymmetric channel-cut Si crystals operated close to the Brewster angle, we design and realize a polarimeter optimized for synchrotron-based Mössbauer spectroscopy in this range of transition energies. As a demonstration, we implement a four-bounce Si (5 7 11) polarimeter at a photon energy of 22.494 keV at PETRA III and achieve a polarization purity of (1.2 ± 0.5) × 10−8. This establishes the polarimeter performance required for synchrotron Mössbauer spectroscopy at this energy and shows, supported by dynamical-diffraction calculations, that the method can be extended to nuclear transitions up to about 30 keV—opening access to isotopes such as 151Eu, 149Sm, 119Sn, and 161Dy. A nuclear-resonant measurement on these isotopes is the natural next step at a dedicated high-brilliance beamline.
Keywords: high-purity X-ray polarimetry; synchrotron Mössbauer spectroscopy; Mössbauer isotopes151Eu,149Sm,161Dy,40K; X-ray diffraction at high energies; X-ray multiple wave diffraction at high energies.
1. Introduction
With the discovery of recoilless nuclear resonance absorption by Rudolf Mössbauer in 1958 (Mössbauer, 1958
), Mössbauer spectroscopy became an important research technique in all natural sciences, mostly in solid state physics, materials science, biophysics and chemistry. Recoilless nuclear resonance absorption/emission makes it possible to use the natural line width of nuclear transitions for spectroscopy, which typically lie in the range 10−7 to 10−11 eV for most Mössbauer isotopes. This enables high-precision measurements of hyperfine interactions and provides detailed information on charge densities as well as internal electric and magnetic fields in condensed matter.
Modern X-ray sources make it possible to excite nuclear levels from the ground state to perform classical Mössbauer spectroscopy without radioactive sources providing access to smaller samples and enabling shorter integration times (nuclear forward scattering) with unprecedented signal-to-noise ratio. In contrast to a Mössbauer source, synchrotron and X-ray free-electron laser radiation is emitted in short intense pulses which have an energy bandwidth in the eV range. This leads to the simultaneous excitation of the accessible nuclear levels of the nuclei in the sample. Accordingly, the nuclear resonant scattered radiation of the different energy levels interferes with each other, leading to a temporal beating pattern in the life-time of the excited states.
A key challenge for the detector systems in recording these time spectra is the handling of the large number of nonresonant, prompt photons. There are various techniques based on meV-monochromatization or temporal discrimination (Faigel et al., 1987
; Kishimoto, 1992
; Toellner, 2000
; Röhlsberger et al., 2001
; Toellner et al., 2011
), used individually or in combination, to discriminate the resonantly scattered photons from the energetically broadband synchrotron beam. One of these techniques is the polarization filtering method (Toellner et al., 1995
; Siddons et al., 1995
). This method uses the splitting of the energy levels of the atomic nucleus when an external magnetic field is applied, i.e. the nuclear A σ to π change in polarization of the resonantly scattered photons occurs for transitions with an angular momentum change of ΔI = ±1. Since no polarization change occurs for the non-resonantly scattered photons, it is possible to filter out the resonantly scattered photons with a linear polarization analyzer in crossed setting.
Due to the very strong rejection of the nonresonant `prompt' radiation, one obtains access to the early times after excitation, which are important, e.g. for the reconstruction of magnetic spin structures from the nuclear time spectra. To the best of our knowledge, Mössbauer spectroscopy combined with high-precision X-ray polarimetry has so far been restricted in practice to 57Fe (Siddons et al., 1995
; Toellner et al., 1995
; Röhlsberger et al., 1997
; Siddons et al., 1999
; Alp et al., 2000
; Heeg et al., 2013
; Heeg et al., 2015
; Marx-Glowna et al., 2021
), the most frequently used Mössbauer isotope. Polarization control for 57Fe Mössbauer radiation has also been demonstrated with a diamond phase plate (Mitsui et al., 2015
), which differs from the crossed high-purity polarizer technique discussed here. Extending high-purity polarimetry into the higher energy range above 14.4 keV would open the door to additional Mössbauer isotopes such as 151Eu, 149Sm, 119Sn and 161Dy, and thereby substantially broaden the range of materials and phenomena accessible to synchrotron Mössbauer spectroscopy.
In this work we address this challenge in the energy range 15–30 keV. We develop and implement an asymmetric channel-cut Si polarimeter optimized for operation near the Brewster angle at 22.494 keV, and we show that polarization purities at the 10−8 level can be achieved under realistic synchrotron beamline conditions. Supported by calculations, our results indicate that synchrotron Mössbauer spectroscopy can be extended to nuclear transitions up to approximately 30 keV, enabling new applications in condensed-matter physics and precision tests of fundamental interactions.
2. High-purity X-ray polarimetry
Typically, X-ray polarimeters based on Bragg reflections by crystals close to 45° (Hart, 1978
; Hrdý et al., 1979
), which is the Brewster angle for X-rays, are used for the polarization filter method. For diffraction at the Brewster angle, the polarization component parallel to the diffraction plane (π-component) is suppressed in accordance with the dynamical theory for X-rays, while the σ-component is reflected.
The degree of freedom for the energy variation of this method is the choice of the crystal material, the lattice planes therein and the diffraction order n. The wavelength λ is related to the lattice plane spacing d of the crystal via the Bragg equation,
The best polarization suppression is achieved at the Brewster angle. However, for applications, like nuclear resonance scattering, the energy is fixed, so that one has to look for Bragg reflections from standard single crystals (silicon, germanium, diamond) that come as close as possible to the X-ray Brewster angle of 45°.
To achieve a high polarization purity even in cases of deviations of the Bragg angle from the ideal 45°, one designs channel-cut crystals with more than two consecutive reflections as linear polarizers (Hart, 1978
; Hart & Rodrigues, 1979
), see Fig. 1
.
| | Figure 1 Schematic setup of a high-precision X-ray polarimeter. The radiation coming from the right is polarized by the first crystal. The second crystal in the extinction position almost completely suppresses the radiation. |
The degree of polarization purity is defined as the ratio of the transmission of the π-component to the transmission of the σ-component (Alp et al., 2000
),
The transmission is a function of the brilliance of the X-ray source and the reflectivity of the crystal around the Bragg reflection. On the one hand, the degree of polarization purity is determined by the divergence, energy and energy bandwidth of the source; on the other hand, the parameters of the polarimeter crystals, that influence the reflectivity (crystal material, crystal orientation, number of crystal reflections), play a crucial role.
Undulators at third-generation X-ray sources, like PETRA III in Hamburg, Germany, can deliver a natural linear polarization purity of δ0 ≃ 10−4 (Marx et al., 2014
). Polarization purity levels of ∼10−7 are possible with the very long undulators at X-ray free-electron lasers (Geloni et al., 2015
). For many experimental applications, the natural degree of polarization of synchrotrons and X-ray free-electron lasers is sufficient so that only a single analyzer crystal is required for a reasonable polarization analysis. For high-precision X-ray polarimetry, as also required for Mössbauer spectroscopy, a high-purity polarizer crystal is needed in addition to the analyzer crystal to achieve degrees of polarization purity equal to or better than 10−8.
Fig. 1
shows the typical setup of an X-ray polarimeter. The incident unpolarized or partially polarized beam is polarized by the first channel-cut crystal. The second channel-cut crystal serves as an analyzer. The analyzer can be rotated around the beam incident from the polarizer to measure polarization rotations or to vary the suppression of the π-component. In the energy range up to 13 keV, polarization purity levels of 1.4 × 10−11 could be achieved with such precision polarimeters (Marx-Glowna et al., 2022
).
2.1. Limitations at higher energies
High-purity X-ray polarimeters, which are based on diffraction in perfect crystals, are subject to limitations with regard to their performance at higher X-ray energies. In the following, the influence of the full width at half-maximum (FWHM) of the reflection curve and multiple-wave diffraction is considered. We will focus in the following discussion on the Bragg geometry in the energy range between 15 keV and 30 keV.
2.1.1. FWHM of the rocking curve
The angular FWHM of a perfect crystal reflection curve Δθ depends on the wavelength λ, the structure factor FH, the volume of the unit cell V, the polarization factor C and the θB,
For polarimetry, the Bragg angle is fixed and, besides the obvious quadratic wavelength proportionality, the energy dependence is also contained in the structure factor. The structure factor is the sum of the complex atomic form factors over the unit cell, weighted by their respective phase factors. The structure factor is typically dominated by its real part. The contribution of the imaginary part to the width is usually negligible.
A narrow rocking curve width implies a highly selective angular and spectral acceptance of the device. The experimentally achievable efficiency therefore depends not only on the intrinsic device characteristics but also on the overlap between the device acceptance and the photon phase space provided by the radiation source and upstream beamline optics. Polarimetry at high energies inherently requires radiation sources with high brilliance and low beam divergence, as the intrinsically narrow rocking curve widths impose stringent constraints on the accepted photon phase space.
The narrow rocking curve width at higher photon energies is also challenging for the adjustment of a precision X-ray polarimeter. On the one hand, a high spectral photon flux and, on the other, a mechanically and temperature-stable setup with precision goniometers are necessary. Standard one-circle goniometers with gearboxes achieve a full step resolution of 0.9′′, which can easily be reduced to 0.1′′ with microstepping. The angular resolution can be improved by a sine drive equipped with piezo actuator and encoder system on top of the goniometer.
The difficulty of narrow rocking curve widths in the higher energy range lies not only in positioning the rocking curve maximum but also in the stable mounting of the polarimeter crystals in the hundredths of an arcsecond range. In order to increase the angular acceptance of the crystal reflections, it is possible to cut them asymmetrically, i.e. the reflecting lattice planes are not parallel but tilted relative to the surface (see Fig. 2
). The asymmetry angle α describes the tilt angle of the lattice planes to the surface. Angle α is negative if the angle of incidence to the crystal surface is smaller than the and correspondingly positive if the angle of incidence is greater than the As a result of the asymmetric reflection, the rocking curve width on the input side of the crystal Δθ− changes to
The asymmetry parameter b contained therein quantifies the asymmetry,
The smaller the asymmetry parameter becomes, the larger the angular acceptance on the input-side of the reflection becomes.
| Figure 2 Asymmetrically cut crystal. The asymmetry angle α is the angle between the crystal surface and the diffracting lattice planes. For the grazing incidence case shown in the image, the angle is negative by definition. |
This is accompanied by a widening of the beam on the output side S+,
Table 1
shows the influence of the asymmetry angle on the rocking curve width and the degree of polarization purity for different numbers of crystal reflections i using Si (5 7 11) for 149Sm as an example.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
A smaller asymmetry angle increases the FWHM of the rocking curve and leads to a slight improvement in the degree of polarization purity. Simultaneously, the footprint of the beam in the crystal increases and the peak reflectivity decreases. However, the asymmetry angle in channel-cut crystals cannot be chosen arbitrarily large, as the of the X-rays into the crystal is reduced with smaller asymmetry angles and is therefore more sensitive to defects in the surface of the crystals. The footprint of the beam is also a limiting factor for the choice of asymmetry angle for materials such as diamond. The technically feasible crystal size for diamonds of high quality is in the 12 mm range (Freund et al., 2001
).
In addition to the FWHM values of the rocking curves presented in Table 1
, the effect of the rocking-curve width on the efficiency is of particular importance. For two relevant scenarios the corresponding efficiencies were calculated, assuming an upstream Si (111) monochromator and an incident beam divergence Δθsource of 2 µrad, which can be achieved at modern synchrotron beamlines using collimating optics (Sergueev et al., 2025
).
First the efficiency was calculated for the full spectral bandwidth provided by the Si (111) monochromator,
The reflecting plane spacing is denoted as dhkl. This efficiency is particularly relevant for the alignment and optimization of the instrument. If the transmitted intensity is too low, achieving and experimentally verifying high degrees of polarization purities becomes increasingly challenging due to insufficient photon statistics.
Second, the efficiency was calculated for the narrow energy bandwidth of the nuclear resonance representative of the intended application. In the case that the divergence of the source Δθsource is smaller than the FWHM of the reflection of the Si (111) monochromator, the efficiency for the bandwidth of the resonance can be determined as follows,
As evident from the values summarized in Table 1
, the efficiency within the narrow energy bandwidth of the nuclear resonance exceeds the efficiency corresponding to the full monochromator bandwidth by approximately two orders of magnitude. The reduction in efficiency by roughly one order of magnitude for the analyzer crystal alone, and by about two orders of magnitude for the combined polarizer–analyzer configuration, places stringent requirements on source brilliance and nuclear resonant absorption cross sections, thereby favoring the use of high-brilliance radiation sources for Mössbauer spectroscopy.
2.1.2. X-ray multiple-wave diffraction
The current range of application of precision X-ray polarimetry is in the energy range between 6.4 keV and 14.412 keV (Marx et al., 2013
; Heeg et al., 2015
; Schmitt et al., 2021
; Yu et al., 2023
). One of the contributing factors is that the number of possible Bragg reflections increases with increasing photon energy in a crystal, leading to a higher probability of satisfying additional Bragg conditions and thus to stronger multiple-wave diffraction effects. Since the rocking curves have very broad tails, the influence of multiple-wave diffraction on the degree of polarization purity increases and in general the polarization purity will be worse than the theoretical limit in the two-beam case. Multiple-wave diffraction, also referred to as n-beam diffraction, takes into account the simultaneous diffraction of multiple beams in an extension of the widely used two-beam case (Bragg condition) of the dynamical theory of X-ray diffraction.
In order to minimize the influence of multiple-wave diffraction, one can use the remaining degree of freedom, namely to rotate the polarimeter crystals azimuthally [see Fig. 3
(a)], i.e. around an axis that stands perpendicular to the diffracting lattice planes (Renninger, 1937
). Fig. 3
(b) illustrates the variation of the degree of polarization purity as a function of the azimuthal orientation using samarium as an example.
| | Figure 3 (a) Illustration of the azimuthal crystal orientation. (b) Variation of the degree of polarization purity as a function of the azimuthal orientation of the crystal for the 5 7 11 Bragg reflection of silicon at E = 22.494 keV. The simulation was carried out using the multiple-wave diffraction algorithm (Schulze, 2018 |
For the energy of 22.494 keV as chosen here, the best crystal orientation is at an azimuth angle of 21°. This is where the `funnel' in which the required purity is achieved is the largest such that the required orientation accuracy for the polarimeter crystals is the lowest.
The higher the photon energy, the more precisely the azimuthal orientation of the crystals has to be adjusted to achieve high degrees of polarization purity. Table 2
displays the achievable degree of polarization purity for selected nuclear resonances for the specified crystal orientation. In addition, the required accuracy of the azimuthal adjustment of the crystals for a degree of polarization purity of δ0 = 10−8 is indicated. Although the orientation requirements for the crystals increase, very good degrees of polarization purity can also be achieved in the higher energy ranges.
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Another possibility to reduce the influence of multiple-wave diffraction is to choose a crystal material with a low since the influence of multiple-wave diffraction scales with the fourth power of the of the element the channel-cut is made of (Tischler & Batterman, 1986
). Diamond with atomic number Z = 6 is therefore a very suitable polarimeter crystal material.
2.2. Application: Mössbauer spectroscopy at photon energies above 22 keV
As an application example, high-purity polarimetry at high photon energies for Mössbauer spectroscopy will be considered in the following section.
Numerous Mössbauer isotopes are in the energy range 15–30 keV. Table 3
shows a number of selected Mössbauer isotopes with corresponding resonance energy. To estimate the required polarization suppression for the polarization filtering method, the ratio between the nuclear resonance energy bandwidth Γ0 and the energy bandwidth of a Si(111) monochromator is considered in the third column. These monochromators are the standard at the third- and fourth-generation sources. The narrower the energy bandwidth of the resonance, the higher the requirements for the polarization purity of the polarimeter, as this increases the proportion of prompt photons to be filtered out. Secondly the ratio of the nuclear resonance absorption to the total electronic absorption is shown in the fourth column. The lower the value, the better the polarization suppression should be to achieve a good signal-to-noise ratio in the measurements. For most resonances, a polarization purity of the polarimeter of 10−8 is sufficient to keep detector afterpulsing under control during Mössbauer spectroscopy measurements.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The following columns in the table list the reflections closest to the Brewster angle for the chosen Mössbauer isotope with transition energy Eγ. The table indicates that many nuclear resonances can indeed be addressed with one of the standard single crystals. Germanium is not included in Table 3
. Above approximately 14 keV, the extinction length in germanium becomes comparable with the absorption length, reducing the peak reflectivity of the rocking curves. While certain reflections may still be suitable for two-reflection polarizers, the reduced reflectivity makes germanium less attractive for multi-reflection channel-cut designs due to the cumulative reflectivity losses.
Furthermore, Table 3
lists the FWHM values Δθσ for the σ-component of the given reflection. The values show that, for the energy range above 20 keV, the FWHM of the rocking curves is just a few 0.01′′. The considerably narrower acceptance of the polarimeter crystal results in a reduced phase-space overlap with the beam transmitted by the Si(111) monochromator, leading to a lower transmitted photon flux according to equation (7)
.
The last column in Table 3
shows the polarization purity δ0 that can be achieved with i = 2 symmetric reflections. It can be seen that the polarization purity deteriorates the further the deviates from the Brewster angle. This can be counteracted by increasing the number of successive Bragg reflections in channel-cut crystals (Hart, 1978
). Unfortunately, this goes with a reduction of the peak reflectivity and requires larger single crystals or greater technical effort like realizing an artificial channel-cut crystal (quasi-channel-cut) (Bernhardt et al., 2020
). For strongly asymmetrical reflections, only two reflections are technically practicable, as otherwise the beam path in the channel-cut crystal and the crystal size become too large.
3. Demonstration experiment
To demonstrate the feasibility of high-purity X-ray polarimetry at high photon energies, an X-ray polarimeter was developed for the samarium nuclear resonance at 22.494 keV and tested at beamline P24 at PETRA III (DESY, Hamburg, Germany). The beamline provides an energy bandwidth of 2.9 eV at 22.494 keV employing a water-cooled Si (111) monochromator with 50 µm copper absorber. The photon energy transmitted by the monochromator was measured using the Bond method (Bond, 1960
). The beam size was defined to 1 mm × 1 mm by a slit behind the monochromator.
Two four-reflection silicon (5 7 11) channel-cut crystals with an asymmetry angle of α1 = α3 = −28° and α2 = α4 = 28° were used for the polarimeter. The azimuthal orientation of the polarimeter crystals was chosen as 21.0° with respect to and 64.9° with respect to
and was aligned optically via back-reflection of a laser beam from the outer surfaces of the crystal. The alignment of the polarizer crystal was performed using a conventional full-circle goniometer with a full-step resolution of 0.9′′. To monitor the positioning of the polarizer during the measurements, an was installed between the two polarizer channel-cut crystals. In addition to the conventional goniometer, a piezo-driven sine drive (P 401, HUBER Diffraktionstechnik GmbH & Co. KG) with an angular resolution of 0.02′′ was used to align the analyzer crystal on the Bragg reflection.
The analyzer crystal can be rotated to the extinction position (η circle) using a third goniometer which also has a full step resolution of 0.9′′. During the measurement, the synchrotron was operating in the multibunch filling mode at a storage ring current of 100 mA. The detector used was an AdvaPIX TPX3 with a CdTe sensor of 1 mm thickness. Fig. 4
shows the result of the polarization purity measurement near the extinction position (η = 0°) of the polarimeter. The measurement duration per data point was 100 s. The count rate at η = 0° amounts to 0.43 counts s−1. The measurement duration for the required subtraction of the background in the extinction position was 1000 s. The vertical beam divergence at P24 was approximately 136 µrad (∼28′′), far larger than both the angular acceptance of the channel-cut crystals (∼0.06′′) and the 2 µrad divergence assumed for the efficiencies listed in Table 1
; the beamline used here therefore transmitted a substantially lower photon flux than an optimized high-brilliance beamline would. This reduced flux accounts for the low count rate of 0.43 counts s−1. A degree of polarization purity of (1.2 ± 0.5) × 10−8 was achieved, which is sufficient for the intended synchrotron Mössbauer spectroscopy (third column of Table 3
). Further optimization of the crystal azimuthal orientation, for example via beam divergence optimization and background suppression, could in principle improve the result toward the theoretical value.
| Figure 4 Measurement of the polarization purity for four-reflection Si (5 7 11) channel-cuts at a photon energy of 22.494 keV. The orange solid line corresponds to a fit with second-order polynomial. The vertical error bars represent the statistical uncertainties of the data points and the background measurement, assuming Poisson statistics with a 95% confidence level. |
4. Conclusion
This work has shown that high-purity X-ray polarimetry, previously demonstrated only up to photon energies of about 14.4 keV, can in principle be extended to at least 30 keV. In this energy regime two experimental challenges become particularly critical: the extremely narrow rocking-curve widths and the increased influence of multiple-wave diffraction. Here these limitations were addressed using established approaches from dynamical-diffraction theory—asymmetric reflections combined with piezo-driven goniometers for precise angular control, and optimized azimuthal crystal orientations to minimize multiple-wave effects. On this basis, a proof-of-principle polarimeter for 22.494 keV was realized at PETRA III, reaching a polarization purity of (1.2 ± 0.5) × 10−8 even without azimuthal fine tuning—already sufficient for synchrotron Mössbauer spectroscopy. A nuclear-resonant measurement on 149Sm, which requires a dedicated high-brilliance beamline, is the natural next step and was beyond the scope of the present optics development.
High-purity X-ray polarimetry at high energies offers promising applications in Mössbauer spectroscopy. In particular, the nuclear resonance of 149Sm enables precise studies of magnetic phenomena at phase transitions. Samarium-based pyrochlore structures are especially relevant, as geometric frustration gives rise to unconventional magnetic behavior (Singh et al., 2008
; Sain & Upadhyay, 2024
). More generally, our results pave the way for systematic synchrotron Mössbauer experiments on high-energy isotopes and for precision X-ray polarimetry applications such as tests of QED vacuum birefringence (Karbstein & Sundqvist, 2016
).
Acknowledgements
The authors sincerely thank H. Marschner and H. Schulz-Ritter for their technical support. We also wish to thank Yutaka Yoshida and Felix Sommer for assisting during the measurements. We acknowledge DESY (Hamburg, Germany), a member of the Helmholtz Association HGF, for the provision of experimental facilities. Parts of this research were carried out at PETRA III. Data were collected using photon beamline P24. Beam time was allocated for proposal II-20200793. Open access funding enabled and organized by Projekt DEAL. The publication is funded by the Open Access Publishing Fund of GSI Helmholtzzentrum für Schwerionenforschung.
Data availability
The data reported in the article are available upon request to the corresponding author.
References
Alp, E., Sturhahn, W. & Toellner, T. (2000). Hyperfine Interact. 125, 45–68. Web of Science CrossRef CAS Google Scholar
Bernhardt, H., Schmitt, A. T., Grabiger, B., Marx-Glowna, B., Loetzsch, R., Wille, H.-C., Bessas, D., Chumakov, A. I., Rüffer, R., Röhlsberger, R., Stöhlker, T., Uschmann, I., Paulus, G. G. & Schulze, K. S. (2020). Phys. Rev. Res. 2, 023365. CrossRef Google Scholar
Bond, W. L. (1960). Acta Cryst. 13, 814–818. CrossRef CAS IUCr Journals Web of Science Google Scholar
Faigel, G., Siddons, D., Hastings, J., Haustein, P., Grover, J., Remeika, J. & Cooper, A. (1987). Phys. Rev. Lett. 58, 2699–2701. CrossRef PubMed CAS Web of Science Google Scholar
Freund, A., Hoszowska, J., Sellschop, J., Burns, R. & Rebak, M. (2001). Nucl. Instrum. Methods Phys. Res. A 467–468, 384–387. CrossRef CAS Google Scholar
Geloni, G., Kocharyan, V. & Saldin, E. (2015). Opt. Commun. 356, 435–444. CrossRef CAS Google Scholar
Hart, M. (1978). Philos. Mag. B 38, 41–56. CrossRef CAS Google Scholar
Hart, M. & Rodrigues, A. R. D. (1979). Philos. Mag. B 40, 149–157. CrossRef CAS Google Scholar
Heeg, K. P., Haber, J., Schumacher, D., Bocklage, L., Wille, H.-C., Schulze, K. S., Loetzsch, R., Uschmann, I., Paulus, G. G., Rüffer, R., Röhlsberger, R. & Evers, J. (2015). Phys. Rev. Lett. 114, 203601. Web of Science CrossRef PubMed Google Scholar
Heeg, K. P., Wille, H.-C., Schlage, K., Guryeva, T., Schumacher, D., Uschmann, I., Schulze, K. S., Marx, B., Kämpfer, T., Paulus, G. G., Röhlsberger, R. & Evers, J. (2013). Phys. Rev. Lett. 111, 073601. Web of Science CrossRef PubMed Google Scholar
Hrdý, J., Krouský, E. & Renner, O. (1979). Phys. Status Solidi A 53, 143–146. Google Scholar
Karbstein, F. & Sundqvist, C. (2016). Phys. Rev. D. 94, 013004. CrossRef Google Scholar
Kishimoto, S. (1992). Rev. Sci. Instrum. 63, 824–827. CrossRef CAS Web of Science Google Scholar
Marx, B., Schulze, K., Uschmann, I., Kämpfer, T., Lötzsch, R., Wehrhan, O., Wagner, W., Detlefs, C., Roth, T., Härtwig, J., Förster, E., Stöhlker, T. & Paulus, G. G. (2013). Phys. Rev. Lett. 110, 254801. Web of Science CrossRef PubMed Google Scholar
Marx, B., Schulze, K. S., Uschmann, I., Kämpfer, T., Wehrhan, O., Wille, H. C., Schlage, K., Röhlsberger, R., Weckert, E., Förster, E., Stöhlker, T. & Paulus, G. G. (2014). Appl. Phys. Lett. 105, 024103. CrossRef Google Scholar
Marx-Glowna, B., Grabiger, B., Lötzsch, R., Uschmann, I., Schmitt, A., Schulze, K., Last, A., Roth, T., Antipov, S., Schlenvoigt, H., Sergueev, I., Leupold, O., Röhlsberger, R. & Paulus, G. G. (2022). New J. Phys. 24, 053051. Google Scholar
Marx-Glowna, B., Uschmann, I., Schulze, K. S., Marschner, H., Wille, H.-C., Schlage, K., Stöhlker, T., Röhlsberger, R. & Paulus, G. G. (2021). J. Synchrotron Rad. 28, 120–124. CrossRef CAS IUCr Journals Google Scholar
Mitsui, T., Imai, Y., Masuda, R., Seto, M. & Mibu, K. (2015). J. Synchrotron Rad. 22, 427–435. CrossRef CAS IUCr Journals Google Scholar
Mössbauer, R. L. (1958). Z. Phys. 151, 124–143. Google Scholar
Renninger, M. (1937). Z. Phys. 106, 141–176. CrossRef CAS Google Scholar
Röhlsberger, R. (2004). Nuclear Condensed Matter Physics with Synchrotron Radiation. Basic Prin- ciples, Methodology and Applications, No. 208 in Springer Tracts in Modern Physics. Springer-Verlag Berlin Heidelberg. Google Scholar
Röhlsberger, R., Gerdau, E., Rüffer, R., Sturhahn, W., Toellner, T., Chumakov, A. & Alp, E. (1997). Nucl. Instrum. Methods Phys. Res. A 394, 251–255. Google Scholar
Röhlsberger, R., Toellner, T., Quast, K., Sturhahn, W., Alp, E. & Burkel, E. (2001). Nucl. Instrum. Methods Phys. Res. A 467–468, 1473–1476. Google Scholar
Sain, R. & Upadhyay, C. (2024). IOP Conf. Ser. Mater. Sci. Eng. 1300, 012042. Google Scholar
Schmitt, A. T., Joly, Y., Schulze, K. S., Marx-Glowna, B., Uschmann, I., Grabiger, B., Bernhardt, H., Loetzsch, R., Juhin, A., Debray, J., Wille, H., Yavaş, H., Paulus, G. G. & Röhlsberger, R. (2021). Optica, 8, 56. CrossRef Google Scholar
Schulze, K. (2018). APL Photon. 3, 126106. Google Scholar
Sergueev, I., Leupold, O., Jafari, A., Dill, F.-U., Steinbrügge, R., Velten, S., Prajapat, D. & Rüffer, R. (2025). J. Phys. Conf. Ser. 3010, 012049. CrossRef Google Scholar
Siddons, D., Hastings, J., Bergmann, U., Sette, F. & Krisch, M. (1995). Nucl. Instrum. Methods Phys. Res. B 103, 371–375. CrossRef CAS Google Scholar
Siddons, D. P., Bergmann, U. & Hastings, J. B. (1999). Hyperfine Interact. 123–124, 681–719. CrossRef Google Scholar
Singh, S., Saha, S., Dhar, S. K., Suryanarayanan, R., Sood, A. K. & Revcolevschi, A. (2008). Phys. Rev. B 77, 054408. CrossRef Google Scholar
Tischler, J. Z. & Batterman, B. W. (1986). Acta Cryst. A42, 510–514. CrossRef CAS Web of Science IUCr Journals Google Scholar
Toellner, T., Alp, E., Sturhahn, W., Mooney, T., Zhang, X., Ando, M., Yoda, Y. & Kikuta, S. (1995). Appl. Phys. Lett. 67, 1993–1995. CrossRef Web of Science Google Scholar
Toellner, T. S. (2000). Hyperfine Interact. 125, 3–28. Web of Science CrossRef CAS Google Scholar
Toellner, T. S., Alp, E. E., Graber, T., Henning, R. W., Shastri, S. D., Shenoy, G. & Sturhahn, W. (2011). J. Synchrotron Rad. 18, 183–188. Web of Science CrossRef CAS IUCr Journals Google Scholar
Yu, Q., Xu, D., Shen, B., Cowan, T. E. & Schlenvoigt, H. (2023). High Power Laser Sci. Eng. 11, e71. CrossRef Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

menu
access